HomeMy WebLinkAboutBlower Door Test Reporto.e.aeroseal-
ENVELOPE
Battlement Mesa Golfcourse , James Martinez
53 Hogan Cir
Parachute, CO 81635
DATE: BUILDING TYPE:
9/25/2025 Single Family Detached
L'----- SERVICE
1155.3 CFM of Leakage, equivalent to a
139.1 Square Inch Hole, or
3.65 Air Changes per Hour
(for your 1405-ft= structure
enclosing a volume of 18967 cubic feet)
AFTER SERVICE
377.5 CFM of Leakage, equivalent to a
45.4 Square Inch Hole, or
1.19 Air Changes per Hour
This corresponds to a
67.3% Reduction
in Envelope Leakage
NOTE: Envelope leakage and air -change results are
calculated at a standard pressure of 50 Pa.
Sealing time elapsed. 1:28.58
Sealant dispensed: 10506cm3 (2.78 gallons)
ENVELOPE
SEALING REPORT
AEROBARRIER CASE ID: 8279
HARDWARE: AeroBarrier Connect
TECHNICIAN: Coltan
19
a
0
rn
CM
cc
Ll
CD
L)
0 10 20 30 40 50 60 70 80 90
Sealing Time in Mir ---Les
Western Colorado AirBarrier
218 Easter Hill Drive
Grand Junction, CO 81507
Phone:9706237687
NOTES: a) A certified HVAC contractor or rater should be used to assess the need for enhanced/balanced mechanical equipment as the desired IeaKage is
reduced. b) This certificate provides results based on an enclosure test, using positive pressure. A final blower door test may still be required.
SmartSeal 5.0.8.27 (8279 239-239-239) 1 of 2
STATE OF STRUCTURE AT TIME OF SEALING:
• Construction phase: Post Drywall
Number of stories: 1 with basement
Insulation type: Batt
• Attic construction: Vented
• Window count: 6
Door count: 3
• Bathroom vent count: 3
Range hood count: 0
• Fireplace count: 0
• Supply & return register count: 18
LEAKAGE TESTING DETAILS:
Preseal test:
• Test type: SINGLE —POINT
• Elapsed test time: 97s
• Result: [SUCCESS]
• Leakage: 1155.3 CFM50
Postseal test:
• Test type: SINGLE _POINT
• Elapsed test time: 10s
• Result: [SUCCESS]
• Leakage: 377.5 CFM50
SmartSeal 5.0.8.27 (8279-239-239-239) 2 of 2