HomeMy WebLinkAboutBlower Door Test Reporto.e.aeroseal- ENVELOPE Battlement Mesa Golfcourse , James Martinez 53 Hogan Cir Parachute, CO 81635 DATE: BUILDING TYPE: 9/25/2025 Single Family Detached L'----- SERVICE 1155.3 CFM of Leakage, equivalent to a 139.1 Square Inch Hole, or 3.65 Air Changes per Hour (for your 1405-ft= structure enclosing a volume of 18967 cubic feet) AFTER SERVICE 377.5 CFM of Leakage, equivalent to a 45.4 Square Inch Hole, or 1.19 Air Changes per Hour This corresponds to a 67.3% Reduction in Envelope Leakage NOTE: Envelope leakage and air -change results are calculated at a standard pressure of 50 Pa. Sealing time elapsed. 1:28.58 Sealant dispensed: 10506cm3 (2.78 gallons) ENVELOPE SEALING REPORT AEROBARRIER CASE ID: 8279 HARDWARE: AeroBarrier Connect TECHNICIAN: Coltan 19 a 0 rn CM cc Ll CD L) 0 10 20 30 40 50 60 70 80 90 Sealing Time in Mir ---Les Western Colorado AirBarrier 218 Easter Hill Drive Grand Junction, CO 81507 Phone:9706237687 NOTES: a) A certified HVAC contractor or rater should be used to assess the need for enhanced/balanced mechanical equipment as the desired IeaKage is reduced. b) This certificate provides results based on an enclosure test, using positive pressure. A final blower door test may still be required. SmartSeal 5.0.8.27 (8279 239-239-239) 1 of 2 STATE OF STRUCTURE AT TIME OF SEALING: • Construction phase: Post Drywall Number of stories: 1 with basement Insulation type: Batt • Attic construction: Vented • Window count: 6 Door count: 3 • Bathroom vent count: 3 Range hood count: 0 • Fireplace count: 0 • Supply & return register count: 18 LEAKAGE TESTING DETAILS: Preseal test: • Test type: SINGLE —POINT • Elapsed test time: 97s • Result: [SUCCESS] • Leakage: 1155.3 CFM50 Postseal test: • Test type: SINGLE _POINT • Elapsed test time: 10s • Result: [SUCCESS] • Leakage: 377.5 CFM50 SmartSeal 5.0.8.27 (8279-239-239-239) 2 of 2