Loading...
HomeMy WebLinkAboutEngineer's Framing LetterF= anthem structural engineers October 25, 2025 Re: Graber Wells Residence 1193 County Rd 102 Carbondale, CO 81623 Anthem Job Number 24-159 To whom it may concern. After Garfield County framing inspection on 10/24/2025 there were a few structural items that were incomplete or did not match the structural drawings. Below is a list of those items from Garfield County (Matt Provost) and the acceptable structural corrections. 1. Add clips and hangers per plan a. At garage eave connection, Simpson A34 or A35 clip is acceptable or approved equal b. Simpson LUS 210 hanger for deck joist 2. Add king studs per plan a. At the garage windows, 1 trimmer and 1 king stud is acceptable 3. Add missing nails, hangers and clips on deck a. Nails to be added to the hangers b. Hanger to be added to 1 remaining joist c. (3) Timber Lok screws were used in lieu of hangers at edge beam locations. This is structurally acceptable. 4. Add SIDS screws to ledger a. Ledger to be attached to house rim joist using (3) Y4"x4" wood screws @16" in between each deck joist. Inform Anthem of any other structural concerns prior to drywall installation. Sincerely, ANTHEM 000 Ur By: Skyler Fussner Grp Professional Engineer Flls;•;�r�+ Project Manager 10-26-2025�yS e'er 61029 Boulder Office 3800 Arapahoe Avenue, Suite 250 1 Boulder, CO 80302 1303.848.8497 Golden Office 112 N Rubey Dr. Suite 120 1 Golden, CO 80403 1303.848 8497 Steamboat Springs Office 24 5'1 st.I Steamboat Springs, CO 80487 1970.300.3338 anthernstructural.corn I maildanthernstructural corn