HomeMy WebLinkAboutRescheck ReportC�J(Generated by REScheck-Web Software
Compliance Certificate
Project Lot 9 Gilead Gardens Marcelino Holguin ADU + Auto Barn
Energy Code:
2018 IECC
Location:
Garfield County, Colorado
Construction Type:
Single-family
Project Type:
New Construction
Project SubType:
None
Orientation:
Bldg. faces 270 deg. from North
Conditioned Floor Area:
1,150 ft2
Glazing Area
5%
Climate Zone:
5 (8499 HDD)
Permit Date:
Permit Number:
All Electric
false
Is Renewable
false
Has Charger
false
Has Battery:
false
Has Heat Pump:
false
Construction Site: Owner/Agent:
Lot 3 The Rapids on The Colorado
New Castle, CO 81647
Designer/Contractor:
Mic Baca
Studio M Engineers
970 366 8690
Compliance: 4.4% Better Than Code Maximum UA: 259 Your UA: 152
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home.
Slab -on -grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab -on -grade
assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements.
Envelope Assemblies
Upper Floor Ceiling: Flat Ceiling or Scissor Truss
286
49.0
Ceiling Over Clerestory: Flat Ceiling or Scissor Truss
396
49.0
2nd Level Back Wall: Wood Frame, 16" o.c.
160
20.0
Orientation: Back
2nd Level Back Wall Window: Vinyl Frame
20
Orientation: Back
2nd Level Right Wall: Wood Frame, 16" D.C.
322
20.0
Orientation: Right side
2nd Level Front Wall: Wood Frame, 16" o.c.
160
20.0
Orientation: Front
2nd Level Front Wall Window: Vinyl Frame
20
Orientation: Front
Project Title: Lot 9 Gilead Gardens Marcelino Holguin ADU + Auto Barn
Data filename:
0.0
0.026
0.026
7
7
0.0
0.026
0.026
10
10
0.0
0.059
0.060
8
8
0.300
0.300
6
6
0.0
0.059
0.060
19
19
0.0
0.059
0.060
8
8
0.300
0.300
6
6
Report date: 06/14/25
Page 1 of 2
2nd Level Left Wall: Wood Frame, 16" o.c.
Orientation: Left side 322 20.0 0.0 0.059 0.060 19
19
1st Level Back Wall: Wood Frame, 16" o.c.
Orientation: Back 157 20.0 0.0 0.059 0.060 8
8
1st Level Back Wall Window: Vinyl Frame
Orientation: Back 20 0.300 0.300 6
6
1st Level Right Wall: Wood Frame, 16" o.c.
Orientation: Right side 317 20.0 0.0 0.059 0.060 19
19
1st Level Front Wall: Wood Frame, 16" o.c.
Orientation: Front 147 20.0 0.0 0.059 0.060 7
7
1st Level Front Wall Window: Vinyl Frame
3
Orientation: Front 0 0.300 0.300 9
9
1st Level Left Walls: Wood Frame, 16" o.c.
Orientation: Left side 275 20.0 0.0 0.059 0.060 14
14
1st Level Left Doors: Solid Door (under 50% glazing)
Orientation: Left side 42 0.150 0.300 6
13
Main Level Slab ON Grade: Slab -On -Grade
(Unheated)
Insulation depth: 3.0' 109 10.0 0.660 0.700 0
0
Insulation position: Horizontal Insulation
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in
REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Name - Title
Signature
Project Title: Lot 9 Gilead Gardens Marcelino Holguin ADU + Auto Barn
Data filename:
Date
Report date: 06/14/25
Page 2 of 2
l�(2018 IECC Energy
j Efficiency Certificate
Above -Grade Wall 20.00
Below -Grade Wall 0.00
Floor 10.00
Ceiling / Roof 49.00
Ductwork (unconditioned spaces):
Window 0.30
Door 0.15
Heating System•
Cooling System•
Water Heater•
Name• Date•