Loading...
HomeMy WebLinkAboutSubsoils Report for Foundation DesignGrand Valley Consulting, LLC dba RESIDENTIAL SOIL INVESTIGATION 310 Eagle Ridge Drive Battlement Mesa, Colorado Prepared For: Stan Daily 970-404-5415 Sdaily2000 _yahoo.com Job No. 4,506 October 30, 2020 (970) 261-3415 • jwithers@geotechnicalgroup.net 3510 Ponderosa Way, Grand Junction, Colorado 81506 TABLE OF CONTENTS SCOPE............................................................................................................................1 SUMMARYOF CONCLUSIONS.................................................................................... 2 SITECONDITIONS.........................................................................................................3 SITEGEOLOGY.............................................................................................................3 SUBSURFACECONDITIONS........................................................................................4 RESIDENCEFOUNDATIONS........................................................................................5 FOOTINGFOUNDATION.................................................................................................... 6 FLOORSYSTEMS..........................................................................................................7 BELOW -GRADE CONSTRUCTION............................................................................... 9 CONCRETE..................................................................................................................10 SURFACEDRAINAGE.................................................................................................10 CONSTRUCTION MONITORING.................................................................................12 LIMITATIONS...............................................................................................................12 FIG. 1 - SITE VICINITY MAP FIG. 2 - LOCATIONS OF EXPLORATORY PITS FIGS. 3-4 - LOGS OF EXPLORATORY PITS FIG. 5 - SWELL/CONSOLIDATION TEST RESULTS FIG. 6 - MOISTURE -DENSITY RELATIONSHIP TEST REPORT FIG. 7 - INTERIOR WALL DRAIN CONCEPT FIG. 8 - EXTERIOR WALL DRAIN CONCEPT TABLE I - SUMMARY OF LABORATORY TEST RESULTS SCOPE This report presents the results of a residential soil investigation for the proposed single-family residence to be located at 310 Eagle Ridge Drive in Battlement Mesa, Colorado. Our investigation was conducted to explore subsurface conditions and provide foundation recommendations for the proposed structure. The report includes descriptions of subsoil and groundwater conditions found in two exploratory pits, recommended foundation and floor support systems, allowable design soil pressures, and design and construction criteria for details influenced by the subsurface conditions. This investigation was performed in general conformance with our proposal No. 20-0656 dated 9-16-2020. This investigation used test pits, made by others, as opposed to exploratory borings in order to reduce cost and time. Care should be taken to avoid locations of proposed and future structures with the test pits and to place backfill in a well compacted manner, as detailed in the "RESIDENCE FOUNDATIONS" section of this report. The report was prepared from data developed during our field exploration, laboratory testing, engineering analysis and experience with similar conditions. A brief summary of our conclusions and recommendations follows. Detailed criteria are presented within the report. 310 Eagle Ridge Drive: 10-30-2020 Battlement Mesa, Colorado GEG Job No. 4,506 SUMMARY OF CONCLUSIONS 1. Subsurface conditions encountered in the two exploratory pits consisted 2 to 3 feet of man-made fill underlain by clayey, gravelly sand with cobbles in TP-1 and sandy, gravelly clay with cobbles in TP-2 to the maximum depth explored of 8 feet and 5 feet respectively. Both pits encountered virtual backhoe refusal at the maximum depth excavated. Groundwater was not encountered at the time of investigation. 2. Construction should not bear on locations of the test pits noted on Fig. 2. Former test pits should be backfilled as described in the "RESIDENCE FOUNDATIONS" section of the report. 3. Recommendations for footing foundations placed on well compacted soil subgrade and at least 2 feet of well compacted structural fill are presented herein. A discussion, including detailed design and construction criteria are included in the text of the report. 4. We believe slab -on -grade construction supported by the soils encountered will have some potential for movement. Finished living areas should be structurally supported floors. Additional discussion, including design and construction criteria, is included in the text of the report. 5. Surface drainage should be designed for rapid runoff of surface water away from the proposed structure in each direction. It is very important to control water sources and provide proper drainage as these are common causes of distress. 310 Eagle Ridge Drive: 10-30-2020 2 Battlement Mesa, Colorado GEG Job No. 4,506 SITE CONDITIONS The subject site was located at 310 Eagle Ridge Drive in Battlement, Colorado. A vicinity map showing the site location is included as Fig. 1. The subject site was barren with scattered cobbles and weeds. We observed existing single family residences to the north and east of the site. We observed a vacant lot to the southwest of the subject site. A paved street was located toward the north and east. The subject site slopes down towards the southwest at 6-7 percent as measured by hand level and pacing. SITE GEOLOGY Near site geology was identified on the Geologic Map of the Grand Valley Quadrangle, Garfield County, Colorado by John R. Donnell, Warren E. Yeend, and Marjorie C. Smith, 1986 as alluvial terrace and fan gravel deposits (Pleistocene pre -Bull Lake age). We did not find the underlying overconsolidated strata, to the depths investigated, at time of investigation. PROPOSED CONSTRUCTION Proposed construction includes an approximate 1,830 square foot residence with 3 Y2 car attached garage. It will be one story, wood framed and have no below grade or 310 Eagle Ridge Drive: 10-30-2020 3 Battlement Mesa, Colorado GEG Job No. 4,506 basement areas. Foundations are anticipated to be a footing with grade beam with a structurally supported wood floor. We are requested to use test pits as opposed to exploratory borings in order to reduce costs and to reduce timing. Care should be taken to avoid locations of all future structures with the test pits and to place backfill in a well compacted manner, after this investigation. This is to help mitigate potential of damage caused by settlement of test pit backfill. If proposed construction is different than what is described above, we should be notified so that we can re-evaluate the recommendations given. SUBSURFACE CONDITIONS Subsurface conditions at the site were investigated by observing and sampling the soils encountered in two test pits as excavated by others. Location of the exploratory test pits are shown on Fig. 2. A summary log of the soils found in the exploratory test pits and field penetration resistance tests are presented on Figs. 3 and 4. Subsurface conditions encountered in the two exploratory pits consisted 2 to 3 feet of man-made fill underlain by clayey, gravelly sand with cobbles in TP-1 and sandy, gravelly clay with cobbles in TP-2 to the maximum depth explored of 8 feet and 5 feet respectively. Both pits encountered virtual backhoe refusal at the maximum depth excavated. The man-made fill was sandy to clayey, loose, dry and tan. The clayey, gravelly sand with cobbles was medium dense, dry and tan. The sandy, gravelly clay with cobbles was very stiff, dry and brown. Hoe 310 Eagle Ridge Drive: 10-30-2020 4 Battlement Mesa, Colorado GEG Job No. 4,506 refusal was encountered in both TPs in stacked cobbles/gravels/boulders. The Groundwater was not encountered at time of investigation. One clayey sand sample from TP-1 at 3-6 feet depth was tested for one dimensional swell/consolidation characteristics. The sample tested had a moisture content of 12.3 percent, a dry density of 87 pcf and exhibited 0.6 percent consolidation when wetted under a confining pressure of 500 psf. One sandy clay sample from TP-2 at 3-5 feet depth tested had a moisture content of 7.6 percent, a liquid limit of 44, a plasticity index of 24 and had 66 percent passing the No. 200 sieve (silt and clay sized particles). One sandy clay combined sample from TP-1 and TP-2 at 0-3 feet depth tested had a moisture content of 7.8 percent, a liquid limit of 49, a plasticity index of 18, had 65 percent passing the No. 200 sieve, had 1,700 ppm water soluble sulfates and when tested for standard Proctor values was found to have a maximum dry density of 90 pcf and an optimum moisture content of 28.0 percent. Results of laboratory testing are shown on Figs. 5 and 6 and summarized on Table I. RESIDENCE FOUNDATIONS This investigation indicates subsurface conditions at foundation levels consists of man-made fill (dry and relatively loose) underlain by sandy gravel and cobble. Areas of previous construction and test pits should be avoided. If any existing fill is found in the 310 Eagle Ridge Drive: 10-30-2020 5 Battlement Mesa, Colorado GEG Job No. 4,506 excavation, it should be completely removed and replaced with well compacted and tested structural fill. These soils exhibited some consolidation potential in laboratory tests. Recommendations for footings placed on well compacted native subgrade soil and at least 2 feet well compacted structural fill are presented herein. These criteria were developed from analysis of field and laboratory data and our experience. Combined foundation systems (such as slab) should be avoided. The additional requirements of the structural engineer and structural warrantor (as applicable) should also be considered. Footing Foundation 1. Footing foundations bearing on scarified, moisture conditioned and well compacted native soil subgrade and at least 2 feet of well compacted granular structural fill can be designed for a maximum allowable soil bearin ressure of 3,000 pounds er square foot (psf). If soft or yielding soils are found in excavation, conditions may require stabilization such as alternating layers of a geogrid product and crushed/angular rock. Actual stabilization will be dependent on actual conditions encountered. 2. Grade beams should be well reinforced, both bottom and top, to resist a simple span of at least 12 feet. Reinforcing should be designed by a licensed structural engineer. We recommend a minimum continuous footing width of 18-inches and minimum isolated pad of 30 inches square. 3. The completed excavation, within 2 feet horizontally of foundation, should be scarified a depth of 10-inches, moisture conditioned to within 2 percent of optimum moisture content and compacted to at least 95 percent of standard Proctor maximum dry density (ASTM D698) and tested prior to placing structural fill. If loose or yielding conditions are encountered in the open excavation, they should be removed and replaced with well compacted structural fill. Structural fill should consist of a crushed granular material or soil with a maximum particle site of 2 inches, a maximum liquid 310 Eagle Ridge Drive: 1030-2020 6 Battlement Mesa, Colorado GEG Job No. 4,506 limit of 30 and a maximum of 15 percent passing the No. 200 sieve. The existing site soils less than 6-inches diameter are suitable for reuse. After excavation bottom proof roll using a heavy pneumatic tired vehicle such as a front end loader with full bucket and compaction testing show suitable subgrade preparation. Structural fill should be placed in 10-inch maximum loose lifts and compacted as stated above (imported granular fill compacted to at least 95% maximum modified Proctor dry density ASTM D1557). Our representative should be called to test compaction of subgrade (or provide stabilization recommendations and observations, as applicable) and test compaction of each foot of the structural fill, prior to forming. 4. Exterior walls must be protected from frost action. We understand there is a 36-inch minimum frost depth in the Garfield County area. We recommen re ing code for frost protection requirements. 5. Completed excavations should be inspected by a representative of our firm, prior to forming, to confirm that the soils are as anticipated from the exploratory test borings and to test compaction. FLOOR SYSTEMS We anticipate soils in the zone supporting shallow slabs may have low potential to cause slab movement and related damages. Some movement must be assumed from an increase in moisture by site and adjacent area development and associated landscaping and irrigation. To our knowledge, the only reliable solution to control floor movement is the construction of a structurally supported floor with at least a 12-inch (likely 24 or 36- inch) air space between the floor and subgrade. In our opinion, structural floors should be used in all areas. Floating slabs move. Slabs -on -grade can be used in the driveway, and 310 Eagle Ridge Drive: 10-30-2020 Battlement Mesa, Colorado GEG Job No. 4,506 flatwork areas provided the builder and owner are aware of and accepts risk of potential movement and associated damage. A reinforced slab type integral foundation/floor system is proposed. We recommend the following precautions for construction of slabs -on -grade at this site. These precautions will not prevent movement in the event the underlying soils become wetted; they only tend to reduce or mask damage if movement occurs. The owner and future owners must accept the risk of further maintenance, including possible replacement, of concrete slabs on grade. 1. Concrete slabs on grade should be supported on at least well compacted native soil subgrade. All existing fill should be removed in its entirety and replaced as a well compacted fill. The structural fill should consist of imported crushed granular fill, or native soils less than 6" diameter, as described above in the RESIDENCE FOUNDATIONS section of the report. Prior to fill placement, the resulting subgrade soil should be scarified a depth of 10-inches, moisture conditioned to within 2 percent of optimum moisture content and compacted to at least 95 percent of standard Proctor maximum dry density (ASTM D698). Additional fill, if any, should be placed in thin lifts and compacted as described in the RESIDENCE FOUNDATIONS section, above. Each foot placed should be tested, as stated above, before placing the next lift. The subgrade should also be prepared by scarifying at least 10-inches depth and compacted as stated above. Our representative should be onsite prior to forming to verify soil types and proper subgrade preparation. 2. Slab -on -grade construction should be limited to areas such as exterior flatwork. 3. Slabs should be separated from exterior walls and interior bearing members with a slip joint, which allows free vertical movement of slabs. 4. The use of slab -bearing partitions should be avoided. Where such 310 Eagle Ridge Drive: 10-30-2020 8 Battlement Mesa, Colorado GEG Job No. 4,506 partitions are necessary, a slip joint allowing at least 2 inches of free vertical slab movement should be used. The owner should be advised of potential movement and re-establish this void if it closes. Doorways and stairwells should also be designed for this movement. Sheetrock should not extend to slab -on -grade floors. 5. Underslab plumbing should be eliminated where feasible. Where such plumbing is unavoidable, it should be thoroughly pressure tested during construction for leaks and should be provided with flexible couplings. Gas and water lines leading to slab -supported appliances should be constructed with flexibility. 6. Plumbing and utilities, which pass through slabs, should be isolated from the slabs. Heating and air conditioning systems supported by the slabs should be provided with flexible connections capable of at least 8 inches of vertical movement so that slab movement is not transmitted to the ductwork. 7. Frequent control joints should be provided to reduce problems associated with shrinkage and curling. The American Concrete Institute (ACI) and Portland Cement Association (PCA) recommend a maximum panel size of 8 to 15 feet depending upon concrete thickness and slump, and the maximum aggregate size. We advocate additional control joints 3 feet off and parallel to grade beams and foundation walls. 8. Exterior patio, porch and sidewalk slabs should be designed to function as independent units. Movement of slabs -on -grade should not be transmitted directly to the foundations. Stucco finish (if any) should terminate at least 8 inches above any flatwork. BELOW -GRADE CONSTRUCTION Below -grade construction is not anticipated at this site. Therefore and especially with positive exterior grading, a foundation drain may not be necessary. If desired, a foundation drain may be placed around the exterior of the foundation at a depth of at least 310 Eagle Ridge Drive: 10-30-2020 9 Battlement Mesa, Colorado GEG Job No. 4,506 6 inches below the bottom of the grade beam. The drain system should consist of a minimum 4 inch diameter perforated pipe surrounded by a free draining aggregate and wrapped by an appropriate geotechnical filter fabric. The foundation drain concept is shown on Figs. 7 and 8. A foundation drain may help reduce potential for water but may not relieve all potential sources of water. CONCRETE One combined soil sample from TP-1 and TP-2 at 0-3 feet depth was tested for water-soluble sulfates. This sample had a sulfate concentration of 1,700 ppm, a severe exposure level. We recommend following the American Concrete Institute (ACI) guidelines for sulfate resistant cement. ACI recommends a Type V cement be used for concrete that comes into contact with soils that have a severe exposure on concrete. In addition, concrete should have a maximum water -cement ratio of 0.45 and minimum compressive strength of 4,250 psi. SURFACE DRAINAGE Performance of foundations and concrete flatwork is influenced by surface moisture conditions. Risk of wetting foundation soils can be reduced by carefully planned and maintained surface drainage. Surface drainage should be designed to provide rapid 310 Eagle Ridge Drive: 10-30-2020 10 Battlement Mesa, Colorado GEG Job No. 4,506 runoff of surface water away from the proposed residence. We recommend the following precautions be observed during construction and maintained at all times after the construction is completed. 1. The ground surface surrounding the exterior of the building should be sloped to drain away from the building in all directions. We recommend a slope of at least 12 inches in the first 10 feet around the structure, where possible. In no case should the slope be less than 6 inches in the first 5 feet. The ground surface should be sloped so that water will not pond adjacent to the structure. 2. Backfill around foundation walls should be moistened and compacted. Clayey backfill soils are suitable for reuse in the upper 24 inches of exterior wall backfill. 3. Roof downspouts and drains should discharge well beyond the limits of all backfill. Splash blocks and downspout extenders should be provided at all discharge points. 4. Landscaping should be carefully designed to minimize irrigation. Plants used close to foundation walls should be limited to those with low moisture requirements; irrigated grass and/or plants should not be located within 5 feet of the foundation. Sprinklers should not discharge within 5 feet of foundations. Irrigation should be limited to the minimum amount sufficient to maintain vegetation; application of more water will increase likelihood of slab and foundation movements. 5. Impervious plastic membranes should not be used to cover the ground surface immediately surrounding the structure. These membranes tend to trap moisture and prevent normal evaporation from occurring. Geotextile fabrics can be used to limit the weed growth and allow for evaporation. 310 Eagle Ridge Drive: 1030-2020 11 Battlement Mesa, Colorado GEG Job No. 4,506 CONSTRUCTION MONITORING Geotechnical Engineering Group should be retained to provide general review of construction plans for compliance with our recommendations. Geotechnical Engineering Group should be retained to provide construction testing services during earthwork and foundation construction phases of the work. This is to observe the construction with respect to the geotechnical recommendations, to enable design changes in the event that subsurface conditions differ from those anticipated prior to start of construction and to give the owner a greater degree of confidence that the structure is constructed in accordance with the geotechnical recommendations. LIMITATIONS The scope of services for this study does not include either specifically or by implication any environmental or biological (such as radon, mold, fungi, bacteria, etc.) assessment of the site or identification or prevention of pollutants, biological hazards, hazardous materials or conditions. If the owner is concerned about the potential for such contamination or pollution, other studies should be performed. Two exploratory test pits were observed and sampled as excavated and backfilled by the others. Test pit backfill should be avoided with foundations and slabs. The 310 Eagle Ridge Drive: 10-30-2020 12 Battlement Mesa, Colorado GEG Job No. 4,506 exploratory test pits are representative of conditions encountered only at the exact test pit locations. Variations in the subsoil conditions not indicated by the test pit is always possible. Our representative should observe open foundation excavations to confirm subsurface conditions are as anticipated from the exploratory test pits and foundation are prepared as recommended herein. We should be called to test subgrade soils and structural fill materials and compaction. The scope of work performed is specific to the proposed construction and the client identified by this report. Any other use of the data, recommendations and design parameters (as applicable) provided within this report are not appropriate applications. Other proposed construction and/or reliance by other clients will require project specific review by this firm. Changes in site conditions can occur with time. Changes in standard of practice also occur with time. This report should not be relied upon after a period of three years from the date of this report and is subject to review by this firm in light of new information which may periodically become known. 310 Eagle Ridge Drive: 1030-2020 13 Battlement Mesa, Colorado GEG Job No. 4,506 We believe this investigation was conducted in a manner consistent with that level of care and skill ordinarily used by geotechnical engineers practicing in this area at this time. No other warranty, express or implied, is made. If we can be of further service in discussing the contents of this report or the analysis of the influence of the subsurface conditions on the design of the residence, please call. Sincerely, Grand Valley Consulting, LLC dba GEOTECHNICAL ENGINEERING GROUP Chris Hill, E.I.T. Staff Engineer Reviewed by: John Withers, P.E. Engineer (1 copy emailed) 310 Eagle Ridge Drive: 10-30-2020 14 Battlement Mesa, Colorado GEG Job No. 4,506 *ALA. r� _ �► TP-1 s r f r + P-2 Approximate Location of Proposed Residence ;Ole '• . �■ i NOTE: THIS FIGURE WAS PREPARED BASED ON AN IMAGE FROM BING MAPS DIAGRAM IS FOR GENERAL LOCATION ONLY, AND IS NOT INTENDED FOR CONSTRUCTION PURPOSES u - Indicates location of exploratory pits. Project Manager: Project No. LOCATIONS OF EXPLORATORY PITS FIG No. JPW 4.506 Drawn by: CDH Scale: N.T.S - .■ 310 Eagle Ridge Drive File Name: 2 BPLAN Grand Junction Date: 35m Ponaeroe, way Grand Junction, Color,tla 91506 1 Colorado 0/27/2020 PH (970) 261-3415 1wilh-@geolechni,e19 up net LOCATION: See Figure 2 DRILLER: Owner DEPTH TO WATER> INITIAL: s NATD DATE:.. 10-2-20 DIAMETER 7' x 15' Description J ELEVATION: LOGGED BY: JW AFTER 24 HOURS: s backfill DEPTH TO CAVING: TOTAL DEPTH 8 Ft Man-made fill, sand, clayey, gravelly, cobbles, loose, dry and tan (SC) Sand, clayey, gravelly, cobbles, medium dense, dry and tan (SC) 5 Hoe refusal in stacked cobbles/gravels at 8 feet 10 This information Project No.: 4,506 Client: Stan Daily 3510 Ponderosa Way, Grand Junction, Colorado 51506 Date: 1013012020 (970) 261-3415 not be ? ! " -• Lo�'E_ z N L ? `�' 6 S Notes 0 .. ,n� m� Bulk sample from 0-3' Bulk sample from 3-6' indicitive of the site. LOG OF EXPLORATORY TEST PIT TP-1 310 Eagle Ridge Drive Battlement Mesa, Colorado Fig 3 LOCATION: See Figure 2 DRILLER: Owner _ DEPTH TO WATERS INITIAL: s _NATD DATE: 10-2-20 DIAMETER Tx 15' Description 0 ELEVATION: LOGGED BY: JW AFTER 24 HOURS: i backfill DEPTH TO CAVING: TOTAL DEPTH 5 Ft Man-made fill, clay, sandy, loose, dry and tan (CL) clay, sandy, gravelly, cobbles, very stiff, dry and brown (CL) 5 Hoe refusal in stacked cobbles/boulder at 5 feet 10 This information Project No.: 4,506 Client: Stan Daily 3510 Ponderosa Way, Grand Junction, Colorado 81506 Date: 10130/2020 (970) 261-3415 be t a = Notes M n~ m0 Bulk sample from 0-3' indicitive of the site. LOG OF EXPLORATORY TEST PIT TP-2 310 Eagle Ridge Drive Battlement Mesa, Colorado Fig 1111111111 I I I I I I I I I !i11111111IIIIIIIIII� IIIIIliiil:!!1111111' Illlllllll lllllllii: 11111111111111111111 11111111111111111111 Illlllllll lllllllll. 11111111111111111111 11111111t1 lllIIIIIII 1111111111 I I f l l IIIII 11111111/1 IIIIIIIIII 1111111111 Illlllllll 11111111lI Illlllllll IIIIIIIIII IIIIIIIIII 11111111111111111111 11111111111111111111 1111111111IIIIIIIIII 1111111111 IIIIIIIIII 11111111111111111111 1111111111 I I I I I I I I I Illllll111 IIIIIIIIII Illlllllll IIIIIIIIII Illlllllll IIIIIIIIII I1u111111IIIIIIIIII ilulllltl IIIIIIIIII GEOTECHNICAL ENGINEERING GROUP m1111111111f111111 1111111111111110111 111111 ! I 1 11111111111 IIIII lull lull lull 111111u11 ttllllflll f111111111IIIIIAIII lull IIIH lull 11111 I111111111IIIIIAIII 11111111111111111111 Illil IIIII IIIII IIIII 1111111111 IIIII IIIII 11111111111111111111 1181111111111111111 1111111 C 111111111111 1111111110111111111 IIIIIIIIIIIh1111111 11111111111111� IIIII 1111111111111114111 11111111111111111111 11111111111111111111 111111111111111111��I IIIII IIIII1111111111 111111111111111 I11 V 1111111111 I l l l l l l l l� 111111111111111 I l l l i 111111111111111 I I I I 111111111111111 I I I I 11111111111111111111 11111111111111111111 MOISTUPE- DEI�iSITY RELATIONSHIP TEST REPORT Pro Iect No 4,SOb Prolert 310 Eagle Ridge Drive Elev /Depth 0-3' Source TP-1 and TP-2 at 0-3' Pemarks P1ATERIAL DESCRIPTION De SL fnpt1on Clay, sandy (CL) ClassifICat!on = at MoIsf = 18 Liquid Limit = 49 M 130 120 110 100 9n 80 Date 10-2-2020 Sample No 1 USCS (CL) AASH T 0 SP G = Plasticity Index - 18 ,o No 200 = 55% MATERIAL DESCRIPTION Maximum Dry Density = 90 pcf Optimum Moisture = 280. AL TO 200 15 20 25 LO Water Cortent, Fig. 6 Slope per OSHA L\ Slope per report I 1 Backfill —, Below grade wall Reinforcing steel per structural drawings. :.. Footing or pad --I or deep foundation bottom of grade beam Encase pipe in washed concrete aggregate (ASTM C33, No. 57 or No. 67). Extend gravel at least halfway up continuous footings and void if pads or interrupted footings are used. Note: Drain Should be at least 4 inches below bottom of footing or alternative deep foundation bottom of grade beam at the highest point and slope downward to a positive gravity outlet or to a sump where water can be removed by pumping. Provide positive slip joint between slab and wall. Cover gravel with filter fabric or roofing felt. Bottom of • `. Excavation SFOPWt� oddW, 1 4" Minimum 6 8" Minimum or beyond 1:1 slope from bottom of footing_ (Whichever is greater). 4-inch diameter perforated drain pipe. The pipe should be placed in a trench with a slope ranging between 1/8-inch and 1/4-inch drop per foot of drain. Interior Foundation Wall Drain Concept Job No. 4,506 Fig. 7 Slope per report \— Backfill —\ Below grade wall Slope per Reinforcing steel _ OSHA per structural drawings. Cover gravel with filter fabric or roofing felt. 6" Minimum �I Encase pipe in washed concrete - aggregate (ASTM C33, No. 57 or No. 67). Extend gravel laterally to void and as high as possible up the side of void (1 to 2 inches). Provide PVC sheeting glued to foundation wall to reduce moisture penetration. n Note: Drain should be at least 4 inches below bottom of footing or alternative deep foundation bottom of grade beam at the highest point and slope downward to a positive gravity outlet or to a sump where water can be removed by pumping. Footing, pad or J deep foundation bottom of grade beam 4-inch diameter perforated drain pipe. The pipe should be placed in a trench with a slope ranging between 1/8-inch and 1/4-inch drop per foot of drain. Exterior Foundation Wall Drain Concept Job No. 4,506 Fig. 8 d �L d R d W O M O LO O Z m 0 W m Q H U J J U) U U C a T � ~ m p U Cl) U) CO >, >, C co m ns U U E o o so�wa �0 CM Z N N c C d CO co Cn Cfl aZm Im E az Z Cn ` W 0. 0 �o o °n c_ O C y O U C y a to v a` 3 rn m a 3� CO o rn x N 00 E yc ME — FL Im d a YY J J pr- c. d �. OD _7 h o m CO CO CV r,- C W ay CO U? M v M M C7 y r N 06 2 a d H a_