Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Manual J Report
Dexter Diagnostics at D Summary Project 1 •7 Date: 9/8125 FAU1 Main By m For: Tate Fairbanks 960107 County Rd., Carbondale, CO 81623 Email: tate@tateavil.com Notes: -Design• • Weather: Rifle Garfield CountyAP, CO, US Winter Design Conditions Summer Design Conditions Outside db -2 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 72 °F Design TD 18 °F Daily range H Relative humidity 50 % Ventilation Method ASHRAE 62.2-2010 Moisture difference 43 gdlb Heating Summary Structure 51205 Btuh Ducts 0 Btuh Central vent (46 cfm) 2853 Btuh Outside air Humidification Piping Equipment load Infiltration Method Shielding / stories Pressure /AVF 0 Btuh 54058 Btuh Blower door 3 (partial) / 2 50 Pa 13064 cfm Heatingg Coolin�gg Area (ftx) 2372 2372 Volume (ft3) 48430 48430 Air changes/hour 0.27 0.14 Equiv.AVF (cfm) 221 110 Heating Equipment Summary Make Generic Trade Model SEER214.0, HSPF2 8.1 AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point= 34 " F 8.1 HSPF2 23881 Btuh @ 47-F 0 1733 cfm 0.034 cfm/Btuh 0 in H2O Sensible Cooling Equipment Load Sizing Structure 18864 Btuh Duds 0 Btuh Central vent (46 dm) 697 Btuh Outside air Blower 0 Btuh Use manufacturer's data n Rate/swingg multiplier 0.98 Equipment sensible load 19092 Btuh Latent Cooling Equipment Load Sizing Structure -1933 Btuh Duds 0 Btuh Central vent (46 cfm) -1064 Btuh Outside air Equipment latent load 0 Btuh Equipment Total Load (Sen+Lat) 19092 Bluh Req. total capacity at 0.80 SHR 2.0 ton Cooling Equipment Summary Make Generic Trade Cond SEER214.0, HSPF2 8.1 Coil AHRI ref Efficiency Sensibte cooling Latent coal i ng Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 12.2 EER2,14 SEER2 19200 Btuh 4800 Btuh 24000 Btuh 1733 cfm 0.092 cfm/Btuh 0 in H2O 1.00 BddWk values have been manually overrftbn Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 2025-Sep-2611.46:01 -;W 2025 25.0.03 RSU56566 Page t -_7 [Tale Fairbarks}Wppfegale—Mama I J f utt np Calc= KA Frort Door iaaes N Dexter Diagnastics Project Summary FAU2 Upper Project Information For. Tate Fairbanks 960107 County Rd., Carbondale, CO 81623 Email: tate@tatecivil.com Notes: Desian Information Weather. Winter Design Conditions Outside db -2 OF Inside db 70 OF Design TD 72 OF Ventilation Method MJ8 Heating Summary Structure 17035 Btuh Ducts 0 Btuh Central vent (50 cfm) 3109 Btuh Outside air Humidification 0 Btuh Piping 0 Btuh Equipment load 20143 Btuh Infiltration Method Shielding / stories Pressure /AVF Rifle Garfield CountyAP, CO, US Blower door 3(partial)/2 50 Pa 3064 cfm He Cooling Area 1h'ng 3444 Uafume fo) 15434564 15456 c Jrhangeslhour 0.31 0.15 Equiv. AVF (cfm) 80 40 Heating Equipment Summary Make Generic Trade Model SEER214.0, HSPF2 8.1 AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capacity balance point = 33 °F 8.1 HSPF2 8955 Btuh @ 47°F 35 0 300 cfm 0.018 cfm/Btuh 0 in H2O Job: Dabs: 9/8/25 By: Summer Design Conditions Outside db 93 OF Inside db 75 OF Design TD 18 OF Daily range H Relative humidity 50 % Moisture difference -43 gr/lb Sensible Cooling Equipment Load Sizing Structure 5069 Btuh Ducts 0 Btuh Central vent (50 cim) 760 Btuh Outside air Blower 0 Btuh Use manufacturer's data n Rate/swingg multiplier 0.98 Equipment sensible load 5689 Btuh Latent Cooling Equipment Load Sizing Structure -511 Btuh Ducts 0 Btuh Central vent (50 cfm) -1160 Btuh Outside air Equipment latent load 0 Btuh Equipment Total Load (Sen+Lat) 5689 Btuh Req. total capacity at 0.70 SHR 0.7 ton Cooling Equipment Summary Make Generic Trade Cond SEER214.0, HSPF2 8.1 Coil AHRI ref Efficiency 122 EER2, 14 SEER2 Sensible cooling 6300 Btuh Latent cooling 2700 Btuh Total cooling 9000 Btuh Actual air flow 300 cfm Airflowfactor 0.059 dm/Btuh Static pressure 0 in H2O Load sensible heat ratio 1.00 BdditAc values have been manually ovenidden Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -FW wri�gFatsoit- 2025-Sep-2611.46U1 •-^•� « -,�mP� Nght-Sdte@ Uriversal 2025 25.0.03 RSU56586 Page 3 7(Tate Fairbarks)Wpplegate_MarnslJfixednp Calc=MJ8 FroRDoor faces'. N Dexter Diagnostics Load Short Form Job: Date: 918125 la"oFAU1 Main By: Project Information For. Tate Fairbanks 960107 County Rd., Carbondale, CO 81623 Email: tate@tatecivil.com Desigg Information Htg cig InfiHrabon Outside db (°F) -2 93 Method Blower door Inside db (°F) 70 75 Shielding / stories 3 (partial) / 2 Design TD (°F) 72 18 Pressure /AVF 50 Pa / 3064 cfm Daily range - H Inside humidity (%) 30 50 Moisture difference (grAb) 37 -43 HEATING EQUIPMENT Make Generic Trade Model SEER214.0, HSPF2 8.1 AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point = 34 °F 8.1 HSPF2 23881 Btuh @ 47°F 16 °F 1733 cfrm 0.034 cfm/Btuh 0 in H2O COOLING EQUIPMENT Make Generic Trade Cond SEER214.0, HSPF2 8.1 Cal AHRI ref Efficiency 12.2 EER2,14 SEER2 Sensible cooling 19200 Btuh Latentcooling 4800 Btuh Total cooling 24000 Btuh Actual airflow 1733 cfnl Airflowfactor 0.092 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 1.00 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) HtgAVF (cf) CIgAVF (Cfm) Primary - Bed 256 7348 2853 249 262 Primary - Bath 200 1 10448 3753 354 345 Primary - Closet 144 0 0 0 0 Guest Bed 181 3700 1567 125 144 Bathroom 81 0 0 0 0 Living / IGtchen 1118 22511 8856 762 814 Pantry 117 3914 619 132 57 Laundry 138 3283 1216 111 112 Stairs 60 0 0 0 0 IN n n n BokiNalic values have been manualy overtldden Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - wrightsof#- ,,'� MgMSiite®U iversal202525.0.03 FZSU56586 ACCN ...7(TateFairbarks)Wpplegate ManjaIJfxed.np Calc=MJ8 FrortWoriaoes: N 2025-Sep-2611:46:00 Page 2 FAW Main 2372 51205 18864 1733 1733 Other equip loads 2853 697 Equip. @ 0.98 RSM 19092 Latent cooling 0 T^ AI e� noon eeneo 4nnnn 9744 4744 I V 1/"LL��J LVI L ar�Vvv IvvvL .. vv .. vv BoOitalic values have been manuals ovenidden Calculations approved byACCA to meet all requirements of Manual J 8th Ed. W1'IQht%soitT 2025-Sep-2611:46U0 M1•••-.••» Right-SUte8Uri%ersal202525.0.03RSU56586 Page ACCA ...7(Tate Fairbarics)Wpplegate_MannlJSxednp Calc=MJ8 Frorttborfaces: N Dexter Diagnostics Load Short Form Job` Date: 918125 00,040 FAU2 Upper Br. Project Information For. Tate Fairbanks 960107 County Rd., Carbondale, CO 81623 Email: tate@tatecivil.00m Design Information Htg Clg Infiltration Outside db (OF) -2 93 Method Blower door Inside db (OF) 70 75 Shielding / stories 3 (partial) / 2 Design TD (OF) 72 18 Pressure /AVF 50 Pa / 3064 dm Daily range - H Inside humidity (%) 30 50 Moisture difference (grAb) 37 -43 HEATING EQUIPMENT Make Generic Trade Model SEER214.0, HSPF2 8.1 AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point = 33 OF 8.1 HSPF2 8955 Btuh @ 47-F 35 OF 300 cfm 0.018 cf n/Bluh 0 in H2O COOLING EQUIPMENT Make Generic Trade Cond SEER214.0, HSPF2 8.1 Coil AHRI ref Efficiency 12.2 EER2, Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 14 SEER2 6300 Btuh 2700 Btuh 9000 Btuh 300 cfm 0.059 cfm/Btuh 0 in H2O 1.00 ROOM NAME Area Htg load Clg load HtgAVF ClgAVF OF) (Btuh) (Btuh) (m) (cfirn) Storage 439 6325 2121 111 126 Hall 233 1249 287 22 17 Bath 126 1220 232 21 14 Bedroom - Upper2 273 4486 1265 79 75 Bedroom - Upper1 273 3755 1164 66 69 FAU2 Upper 1344 17035 5069 300 300 Other equip loads 3109 760 Equip. @ 0.98 RSM 5689 Latent cooling 0 Ir^ Al C 49AA 'If%4A-1 i.L240 Rnn inn V IP1LJ IN9'7 LW 1"J -- - - Bdd/lfalls values have been mammy ovenlditl Calculations approved byACCAto meet all requirements of Manual J 8th Ed. + wrightsci t' ,.�� �...-,�...w.•w•....,,a�.•••. PoghFStibe@lkiversa1202525.0.03RSU56566 �+...7(rate Fairbarks)Wpplegate_ManelJtadnp Calc=MJ8 FrordDoor boes N 2025-Sep-2611:46:00 Page 4 Dexter Diagnostics at Component Constructions Date: abe: 9/8/25 Entire House By: For. Tate Fairbanks 960107 County Rd., Carbondale, CO 81623 Email: tat%Otatecivil.com Location: Rifle Garfield County AP, CC, US Elevation: 6740 ftvr- Latitude: 40 'N Outdoor. Heating Cooling Dry bulb (T) -2 ,qe-, 9934 (H ) Daily range (T) - Wet bulb ('F) - 58 Wind speed (mph) 15.0 7.5 Indoor. Heating Cooling Indoor temperature (T) 70 75 Design TD (T) 72 18 Relative humidity (%) 30 50 Moisture difference (gdlb) 36.9 -43.4 Infiltration: Method Blower door Shielding / stories 3 (partial) / 2 Pressure /AVF 50 Pa / 3064 cfm Construction descriptions or Area uvalue Insul R Htg HTM Loss Clg HTM Gain fl? BUff-T ff ABbh BU ff Bbh BUM Bbh Walls AGW R20 - Frm wall, wd ext, 1/2" wood shth, r-20 cav ins, 5/8" gypsum n 1265 0.065 20.0 4.68 5922 0.71 901 board mt fish, 2'k6" wood frm, 16" o.c. stud a 747 0.065 20.0 4.68 3496 0.71 532 Bg wall, light dry soil, concrete war, r-15 ins, 8" thk Partitions Garage Common - Frm wall, 5/8" gyp.bd ext, 1/2" wood shth, r-19 cav ins, 5/8" gypsum board int fnsh, 2"x6" wood frm, 16" OC Windows 0.30 u-value, 0.35 SHGC: 0.30 u-value, 0.35 SHGC; NFRC rated n (SHGC=0.35); 9.5 ft overhang (4.5 ft window ht, 2 ft sep.); 6.67 ft head ht 0.30 u-value, 0.35 SHGC: 0.30 u-value, 0.35 SHGC; NFRC rated n (SHGC=0.35); 1 ft overhang (6.3 ft window ht, 5.5 ft sep.); 6.67 ft head ht 0.30 u-value, 0.35 SHGC: 0.30 u value, 0.35 SHGC; NFRC rated n (SHGC=0.35); 9.5 ft overhang (8.5 ft window ht, 1 ft sep.); 6.67 ft head ht n all 0.30 u-value, 0.35 SHGC: 0.30 uvalue, 0.35 SHGC; NFRC rated n (SHGC=0.35); 9.5 ft overhang (10 ft window ht, 1 it sep.); 6.67 it head ht n all French Doors: French Doors; NFRC rated (SHGC=0.40); 9.5 ft overhang n (10 it window ht, 1 ft sep.); 6.67 ft head ht Milgard 0.30 - 2 glazing, dr outr, air gas, wd frm mat, dr innr, 1/4" gap, 1/4" n thk: Milgard 0.30 - 2 glazing, dr outr, air gas, wd frm mat, dr innr, 114" gap, 1/4" thk; NFRC rated (SHGC=0.35); 6.67 ft head ht s 1337 0.065 20.0 4.68 6259 0.71 952 w 644 0.065 20.0 4.68 3014 0.71 458 all 3994 0.065 20.0 4.68 18690 0.71 2842 n 312 0.028 15.0 3.64 1135 0.26 81 e 162 0.028 15.0 3.62 586 0.26 42 s 312 0.028 15.0 3.63 1133 0.26 81 w 162 0.028 15.0 3.62 586 0.26 42 all 948 0.028 15.0 3.63 3439 0.26 246 488 0.068 19.0 2.58 1261 0.68 332 22 0.300 0 21.6 470 12.1 262 33 0.300 0 21.6 703 12.1 393 69 0.300 0 21.6 1484 12.1 829 69 0.300 0 21.6 1499 12.1 838 138 0.300 0 21.6 2984 12.1 1667 19 0.300 0 21.6 414 12.1 231 20 0.300 0 21.6 432 12.1 241 39 0.300 0 21.6 846 12.1 473 41 0.300 0 21.6 882 13.0 532 63 0.300 0 21.6 1366 12.1 763 W rightsaft - 2025-Sep-2611:46:00 i .M".. , ... Right -Suite@ llriversa12025 25.0.03 RSU56586 Page 1 .� ✓:'•. .7 (Tate FairbarfiCs)V4pplegate_Manual J fid.rtp Calc= M 18 Front Door faces: N 0.30 u-value, 0.35 SHGC: 0.30 uaralue, 0.35 SHGC; NFRC rated e (SHGC=0.35); 6.67 ft head ht 0.30 u-value, 0.35 SHGC: 0.30 u-value, 0.35 SHGC; NFRC rated s (SHGC=0.35); 14 ft overhang (6.5 ft window ht, 1.5 ft sep.); 6.67 ft head ht 0.30 u-value, 0.35 SHGC: 0.30 uwalue, 0.35 SHGC; NFRC rated s (SHGC=0.35); 14 ft overhang (10 ft window ht, 1.5 ft sep.); 6.67 ft head ht s all French Doors: French Doors; NFRC rated (SHGC=0.40); 14 ft overhang s (10 ft window ht, 1.5 ft sep.); 6.67 ft head ht s s an French Doors: French Doors; NFRC rated (SHGC=0.40); 14 ft overhang s (10 ft window ht, 5.5 ft sep.); 6.67 ft head ht s an Milgard 0.30 - 2 glazng, dr outr, air gas, cod frm mat, dr innr, 1/4" gap, 1/4" s thk: Milgard 0.30 - 2 glazing, dr outr, air gas, cod frm mat, dr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.35); 1.25 ft overhang (5.75 ft Wndow ht, 6 it sep.); 6.67 ft head ht Doors 11 DO: Door, wd sc type n 11 NO: Door, mtl eps core type n Ceilings 15F3. 3Oacr Attic ceiling, asphalt shingles roof mat, r-20 roof ins, r30 veil ins Rf/dg ceiling, mtl roof mat, frm cons, 5/8" gypsum board int fish, 10" thkns, r349 can ins Rf/dg ceiling, mtl roof mat, frm cons, 5/8" gypsum board int fish, 12" thkns, r-49 ceil ins Floors 21 B-28t: Bg floor, light dry soil, prm int ins cov, 6.5' depth, r-10 ins Bg floor, light dry soil, prm int ins cov, 6.5' depth, r3 ins Fir floor, frm fir, 10" thkns, r30 cav ins, gar ovr wrightseft" MgWSute® U tersal 2025 25.0A3 RSU56586 'L...7(TateFairbanks)Wpplegat_ManelJffxedn4 Calc=MJ8 FrortDwrfaces:N 59 0.300 0 21.6 1274 38.3 2262 53 0.300 0 21.6 1147 12.1 641 18 0.300 0 21.6 396 12.1 221 19 0.300 0 21.6 414 12.1 231 38 0.300 0 21.6 810 12.1 453 31 0.300 0 21.6 666 13.0 402 32 0.300 0 21.6 702 13.0 424 78 0.300 0 21.6 1692 13.0 1021 142 0.300 0 21.6 3060 13.0 1847 39 0.300 0 21.6 846 13.0 511 41 0.300 0 21.6 882 13.0 532 80 0.300 0 21.6 1728 13.0 1043 47 0.300 0 21.6 1025 19.5 923 21 0.390 0 14.8 311 3.90 82 43 0.350 8.7 13.3 574 3.50 151 200 0.032 30.0 2.30 460 1.46 292 2324 0.024 49.0 1.71 3977 0.73 1693 1032 0.023 49.0 1.64 1689 0.70 719 200 0.015 3.0 1.08 216 0 0 2372 0.009 3.0 0.62 1478 0 0 984 0.036 30.0 1.30 1276 0.20 200 2025-Sep-26 11 :46.00 Page 2 WON Job #: Performed for: Tate Fairbanks 960 107 County Rd. Carbondale, CO 81623 Crawlsapce Scale: 1 : 167 Page 1 Right -Suite® Universal 2025 25.0.03 RSU56586 2025-Sep-26 11:46:09 ...ks)Wpplegate_Manual J fixed.rup Job M Performed for: Tate Fairbanks 960 107 County Rd. Carbondale, CO 81623 Scale: 1 : 167 Page 2 Right -Suite® Universal 2025 25.0.03 RSU56586 2025-Sep-26 11:46:09 ..ks)VWpplegate_Manual J fixed.rup ninn oLE Job #: Performed for: Tate Fairbanks 960 107 County Rd. Carbondale, CO 81623 Upper Floor Scale: 1 : 167 Page 3 Right -Suite® Universal 2025 25.0.03 RSU56586 2025-Sep-26 11:46:09 ..ks)1Applegate_Manual J fixed.rup