Loading...
HomeMy WebLinkAboutStructural Calcs-Update SnowloadT2 Structural JOB TITLE Cabondale SFR PO Box 487 Bozeman, MT 59771 JOB No. 23-165 SHEET NO. 206.200.4853 CALCULATED BY DATE CHECKED BY i DATE CS2021 Ver 2023-01-21 www.struware.com L(�(lw SItaWw Cap lCe- f-.VV aka STRUCTURAL CALCULATIONS eIeVG(�UIj FOR 7332 County Rd. 100 Carbondale, CO QL T2 Structural JOB TITLE Carbondale SFR PO Box 487 Bozeman, MT 59771 JOB No. 23-165 SHEET NO. 206.200.4853 CALCULATED BY DATE CHECKED BY DATE Wind Loads: ASCE 7- 16 Ultimate Wind Speed 115 mph Nominal Wind Speed 89.1 mph Risk Category II Exposure Category C Enclosure Classif. Enclosed Building Internal pressure +/-0.18 Directionality (Kd) 0.85 Kh case 1 0.937 Kh case 2 0.937 Type of roof Gable I Topographic Factor (Kzt) v{z) Topography Flat Speed-up Hill Height (H) 80.0 ft V(Z) Half Hill Length (Lh) 100.0 ft x(upwind] - x(downwind) w Actual H/Lh = 0.80 Hn Use H/Lh = 0.50 Lh H Modified Lh = 160.0 ft HI2 _ .r From top of crest: x = 50.0 ft Bldg up/down wind? downwind ESCARPMENT H/Lh= 0.50 K, = 0.000 x/Lh = 0.31 Kz = 0.792 V(Z) z/Lh = 0.15 K3 = 1.000 Z Speed-up At Mean Roof Ht: V(Z) x(upvvind) x(downwind) Kzt = (1+KlKzK3)^2 = 1.00 ' H/21 IH Gust Effect Factor h = 24.0 ft B = 43.0 ft /z (0.6h) = 15.0 ft Rigid Structure e = 0.20 £ = 500 ft Zmin = 15 ft c = 0.20 9Q, 9v = 3.4 LZ = 427.1 ft Q = 0.91 IZ = 0.23 G = 0.88 use G = 0.85 2D RIDGE or 3D AXISYMMETRICAL HILL Flexible structure if natural frequency < 1 Hz (T > 1 second). If building h/B>4 then may be flexible and should be investigated. h/B = 0.56 Rigid structure (low rise bldg) G = 0.85 Using rigid structure formula Flexible or Dvnarnically Sensitive Structure Natural Frequency (qj) = 0.0 Hz Damping ratio ((i) = 0 /b = 0.65 /a = 0.15 Vz = 97.1 N , = 0.00 Rn = 0.000 Rh = 28.282 rl = 0.000 RB = 28.282 n = 0.000 RL = 28.282 q = 0.000 9R = 0.000 R = 0.000 Gf = 0.000 h = 24.0 ft REV 1 - SHEET ADDED Garfield County 11/7/2025 BUILDING DEPARTMENT 108 Eighth Street, Suite 401, Glenwood Springs, CO 81601 Tel: (970) 945-8212 BUILDING REQUIREMENTS. RESIDENTIAL PROJECTS Effective: October 15, 2018 (and as updated on June 12, 2023) Reference Building Codes: 2015 IRC, IBC, IFC, IFGC, IMC, IPC 2018 IECC Setbacks: Check subdivision plat and/or Garfield Co. zone district regulations for setback requirements Snowload: (Measured at Roof, not Ground!) =PSF70010 ft. elevation 100 PSF 9001-10000 ft. elevation Roof Load (Wood): Load Duration = 1.0 Seismic Design Category: B or C — See IRC, Figure R301.2 (2) Weathering Probability for Concrete: Severe Termite Infestation Probability: None to slight Wind Speed: 115 mph (Ultimate Design) Wind Exposure: B or C — See Section R301.2.1.4) Frost Depth: 36 inches — Up to 8000 ft. elevation 42 inches — Over 8000 ft. elevation Winter Design Temperature: Minus 2 — Up to 7000 ft. elevation Minus 16 — Over 7000 ft. elevation Air Freezing Index: 2500° F Days —Up to 7000 ft. elevation 7000+ ft. elevation — As determined by Building Official Ice Barrier Underlayment: Required Mean Annual Temp: Variable Insulation: Minimum R-Values per 20181ECC, Table 402.1.2* • Ceilings/Roofs= R-49 • Exterior Walls = R-20 (or R-13 cavity+ R-5 sheathing) • Floors = R-30 (or enough to fill joist cavity w/R-19 min.) • Basement & Crawl Space Walls = R-15 cont./R-19 cavity • Heated Slab Perimeter = R-10 from top of slab and R-5 min. under entire slab. • Unheated Slab Perimeter = R-10 from top of slab to 24" below grade. *Insulation Notes: 1. R-Values shown above are for wood frame construction. See Table 402.2.6 for steel frame buildings. 2. Crawl Spaces — Floors over vented crawl spaces must be insulated with R-30 or enough to fill the entire cavity. Vents shall be located below the bottom of the floor joist per IRC, R-408.1. An alternative to insulating floors, crawl space walls are allowed to be insulated if crawl space is not vented to outdoors and meets the requirements of IRC, Sec. R408.3. 3. Windows/Doors: U = .30; Skylights: U = .55 T2 Structural PO Box 487 JOB TITLE Carbondale SFR Bozeman, MT 59771 JOB NO. 23-165 SHEET NO. 206.200.4853 CALCULATED BY DATE CHECKED BY DATE Seismic Loads: IBC 2021 Risk Category : II Importance Factor (le) : 1.00 Site Class: D - code default Ss (0.2 sec) = 48.20 %g S1 (1.0 sec) = 9.20 %g Strength Level Forces Site specific ground motion analysis performed: Fa = 1.414 Sms = 0.682 Sos = 0.454 Design Category = C Fv = 2.400 Sm1 = 0.221 Sol = 0.147 Design Category = C Seismic Design Category = C Redundancy Coefficient p = 1.30 Number of Stories: 1 Structure Type: All other building systems Horizontal Struct Irregularities: No plan Irregularity Vertical Structural Irregularities: 3) Vertical Geometric Irregularity Flexible Diaphragms: Yes Building System: Bearing Wall Systems Seismic resisting system: Light frame (wood) walls with structural wood shear panels System Structural Height Limit: Height not limited Actual Structural Height (hn) = 24.0 ft DESIGN COEFFICIENTS AND FACTORS Response Modification Coefficient (R) = 6.5 Over -Strength Factor (Do) = 2.5 Deflection Amplification Factor (Cd) = 4 Sos = 0,454 Sc1 = 0.147 Seismic Load Effect (E) = Eh +/-Ev = p QE +/- 0.2Scs D = 1.3Qe +/ 0.091 D QE = horizontal seismic force Special Seismic Load Effect (Em) = Emh +/- Ev = Do QE +/- 0.2Sps D = 2.5Qe +/ 0.091 D D = dead load PERMITTED ANALYTICAL PROCEDURES Simplified Analysis - Use Equivalent Lateral Force Analysis Equivalent Lateral -Force Analysis Building period coef. (CT) = Approx fundamental period (Ta) = User calculated fundamental period = Long Period Transition Period (TL) = Seismic response coef. (Cs) = need not exceed Cs = but not less than Cs = USE Cs = - Permitted 0.020 Cu = 1.61 CThr," = 0.217 sec x= 0.75 Tmax = CuTa = 0 348 sec T= 0217see Model & Seismic Response Analysis ASCE7 map = 6 sec Sdsl/R = 0.070 Sd1 IIRT= 0.104 0.044Sdsl = 0.020 0.070 Design Base Shear V = 0.070W - Permitted (see code for procedure) ALLOWABLE STORY DRIFT Structure Type: All other structures Allowable story drift Aa = 0.020hsx where hsx is the story height below level x T2 Structural PO Box 487 Bozeman, MT 59771 206 200.4853 JOB TITLE Carbondale SFR JOB No. 23-165 SHEET NO. CALCULATED BY DATE CHECKED BY DATE Wind Loads - MWFRS 11s60' (Low-rise Buildings) except for open buildings Kz = Kh (case 1) = 0.94 Base pressure (qh) = 27.0 psf GCpi = +/-0.18 Wind Pressure Coefficients Edge Strip (a) = 4 3 ft End Zone (2a) = 8.6 ft Zone 2 length = 21.5 ft CASE A CASE 9=95deg Surface GCpf w/-GCpi w/+GCpi GCpf w/-GCpi w/+GCpi 1 0.44 0.62 0.26 -0.45 - .27 -0.63 2 -0.69 -0.51 -0.87 -0.69 -0.51 -0.87 3 -0.40 -0 22 -0.58 -0.37 -0.19 -0.55 4 -0 33 -0.15 -0.51 -0.45 -0.27 -0.63 5 0.40 0.58 0.22 6 -0.29 -0.11 -0.47 1 E 0.67 0.85 0.49 7.48 -0.30 -0.66 2E -1.07 -0.89 -1.25 -1.07 -0.89 -1.25 3E -0.58 -0.40 -0.76 -0.53 -0,35 -0.71 4E -0.49 -0.31 -0.67 -0.48 -0.30 -0.66 5E 0.61 0.79 0.43 6E -0.43 -0.25 -0.61 Ultimate Wind Surface Pressures (psf) 1 16.7 7.0 -7.3 -1 .0 2 -13.8 -23.5 -13.8 -23.5 3 -6.0 -15.7 -5.1 -14.8 4 -4.1 -13.8 -7.3 -17.0 5 15.6 5.9 6 -3.0 -12.7 1 E 22.8 13.1 -8.1 -17.8 2E -24.0 -33.7 -24.0 -33.7 3E -10.7 -20.4 -9.4 -19.1 4E -8 4 -18.1 -8.1 -17.8 5E 21.3 11.6 6E -6.7 -16.5 Parapet Windward parapet = 0.0 psf (GCpn = +1.5) Leeward parapet = 0.0 psf (GCpn = -1.0) Horizontal MWFRS Simple Diaphragm Pressures (psf Transverse direction (normal to L) Interior Zone: Wall 20.8 psf Roof -7.7 psf End Zone: Wall 31.3 psf Roof -13.3 psf Longitudinal direction (parallel to L) Interior Zone: Wall 18.6 psf End Zone: Wall 28.0 psf * NOTE: Total horiz force shall not be less than that determined by neglecting roof forces (except for MWFRS moment frames). The code requires the MWFRS be designed for a min ultimate force of 16 psf multiplied by the wall area plus an 8 psf force applied to the vertical projection of the roof Windward roof overhangs = 18.9 psf (upward) add to windward roof pressure WINDWARD OVERHANG M WINDWARDROOF [.FELC A RL RCOF VERTICAL 8 F 4 3 TRANSVERSE ELEVATION wlNawa,Rn ROOF LEEtVARL ROt7F VERTICAL � a LONGTTIIDINAL ELEVATION 3 m n W N l0 LL tvl ''I Ol C e-1 Ol � � m > Y w � 3 N N y � 'o 100 n .may l0 1p U � m m 3 n � I� r; W •-I ti � c c v v¢ W w L v o¢¢ u( Q o 0 :1 z Y o ., a = m, ¢¢ o m W W A] N N U W w w m U N �Nj ti eNy ry ry O eNy N 01 a U O H L O O y � S2 In N N L W N o m O v t o^ o o o n ti ti o m o v 000 O O O O o U N Hoo O N II o u u II Y y li ° n u u n u u V is w E s a a � 5 y z 3 O m U I/J 6 w 0 V . 3 m o l0 '-I rl O Y l0 a -I ei c-I j o Y Y v > H C CO c N vt N Oo O O O n o � 3 o LL L J L L Y 3 m v m l0 N M N c W a U 00 m 1- W O O N Y Y !G H rn o m � C c N V1 N O O O ry a m a F- 0 u u a m o LL ° 72 :2 79 N L N Project: Carbondale ID: 25-113 Engineer: tt Date: 5/16/2024 Seismic Weight Calculations Roof A = 1060 W area of roof P = 125 ft perimeter of roof h = 8 ft story height to level below Pf = 44 psf flat roof snow load (include if exceeds 30 psf) Description Quantity Unit Weight Unit W (kips) Exterior walls 500 ft' 12 psf 6 20% Roof snow 1060 ftz 8.8 psf 9.328 Roof weight 1060 ftz 15 psf 15.9 Total Weight = 31.228 kips Low Roof + Second Floor A = 560 ft` area of floor P = 95 ft perimeter of level hl = 8 ft story height to level below Pf = 44 psf flat roof snow load Description Quantity Unit Weight Unit W (kips) Exterior walls 760 ft' 15 psf 11.4 2nd Floor Weight 560 ftZ 15 psf 8.4 20% Roof Snow 0 ftz 8.8 psf ftz 0 psf 2nd Floor A = 792 ft` area of floor P = 125 ft perimeter of level hl = 8 ft story height to level above Pf = 0 ft flat roof snowload Total Weight = 19.8 kips Description Quantity Unit Weight Unit W (kips) Exterior walls 500 ft' 15 psf 7.5 Floor Weight 792 ftZ 15 psf 11.88 Partions 792 ftZ 0 psf 20% Roof Snow 792 ftZ 0 psf Total Weight= 19.38 kips AL5EISM IC WEIGHT= 70.408 THERESATHOMAS Grid C Foundation Wa;; T2 CONSULTING, LLC Design Detail J � To �r 1� 067ft0.67ft .y Concrete fc = 3500 psi Rebar Fy = 60000 psi Unit Weight = 150 lb/ft' #4 @ 12 in (S&T) #4@12in 2ft - Check Summary Criteria - Ratio Check Provided Required Combination - Stability Checks -- Use basic criteria from common projec...Yes ,/ 0.983 Bearing Pressure 2100 psf 2065 psf 1.OD + 1.01-+ 1.OH Building Code IBC 2021 ,/ 0.749 Bearing Eccentricity 3 in 4 in 1.OD + 1.01-+ 1,OH Concrete Load Combs IBC 2021 (Strength) - Toe Checks - Masonry Load Combs ASCE 7-16 (ASD) v/ 0.057 Shear 4.54 k/ft 0.26 k/ft 12D + 1.61-+ 0.9H Stability Load Combs IBC Retaining Wall St.. ,/ 0.262 Moment 1.89 ft-k/ft 0.5 ft-k/ft 1.2D + 1.61-+ 1.6H Apply Sds Factor to Seismic Combinat.. No - Heel Checks -- Restrained Against Sliding Yes V a180 Shear 4.54 k/ft 0.82 k/ft 1 4D Neglect Bearing At Heel Yes ,/ 0.123 Moment 1.89 ft-k/ft 0.23 ft k/ft 1 2D + 0 5L + 0 9H Use Vert. Comp_ for OT No - Stem Checks --- Use Vert. Comp. for Sliding No L% 0.183 Moment 3.45 ft-k/ft 0.63 ft k/ft 0 9D + 1.6H Use Vert. Comp, for Bearing No 0.365 Shear 2.74 k/ft 1 k/ft 0 9D + 1.6H Use Surcharge for Sliding & OT Yes V 0.185 Max Steel 0.0273 0.0051 0.9D + 0.9H Use Surcharge for Bearing Yes .;/ 0.864 Min Steel 0.02 in'/in 0.01 in2/in 0.91D + 0.9H Neglect Soil Over Toe Neglect Backfll Wt for Coulomb No No f 0.857 Base Development 7 in 6 in 0.9D + 0.9H Factor Soil Weight As Dead Yes ,/ 0.864 Horz Bar Rho 0.0021 0.0018 0.9D + 0.9H Use Passive Force for OT Yes 0.667 Horz Bar Spacing 12 in 18 in 0,9D + 0.9H Assume Pressure To Top Yes Extend Backfill Pressure To Key Bottom No Use Toe Passive Pressure for Bearing No Required F.S. for OT 1.50 Required F.S. for Sliding 1.50 Has Different Safety Factors for Seismic No Allowable Bearing Pressure 2100 psf Req'd Bearing Location Middle third Wall Friction Angle 250 Friction Coefficent 0.35 Soil Reaction Modulus 172800 Ib/ft3 QuickRWall 5.0 (iesweb.com) C:\Users\thoma\0neDr1ve\T2 Consulting\2025 ...\fnd wall.rwd Page 1 of 2 Tuesday 09/23/25 10:14 AM THERESA THOMAS Grid C Foundation Wa;; T2 CONSULTING, LLC Loads DL=0 3 klft, LL=0.5 k/ft Loading OptionslAssumptions 4 Passive pressure neglects top 0 ft of soil. y= 100lb/ft' YEFP = 50 Ib/ft � M � M M ? r y =100 Ib/ft YEFP = 200 lb/ft' Strength Check Results Summary Load Combination Stem stem M-applied M-allow (ft-klft) (ft-klft) 0.9D + 0.9H 0.35 3.45 0.91D + 1.61-1 0.63 3.45 1.21D+0.51-+0.91-1 0.35 3.45 1.21D+0.51-+1.61-1 0.63 3.45 1.21D+1.61-+0.9H 0.35 3.45 1.21D+1.61-+1.6H 0.63 3.45 1.21D + 0.91-1 0.35 3.45 1.21D+1.61H 0.63 3.45 1.4D 0 0 Load Combination Heel Heel Mallow V-applied (ft-klft) (klft) 0.91D + 0.91-1 1.89 0.53 0.91D + 1.61-1 1-89 0.53 1.21D+0.51-+0.91-1 1-89 0.7 1.21D+0.51-+1.61-1 1.89 0.7 1.21D+1.61-+0.91-1 1.89 0.7 1.21D + 1.6L+ 1.61-1 1.89 0.7 1.21D + 0.91H 1.89 0.7 1.21D + 1.61-1 1-89 0.7 1.41D 1-89 0.82 Stability Check Results Summa Load Combination SWIM Resisting Sliding Force Force F.S. (Iblin) (Iblin) 1 OD + 1 OL + 1 OH 144.7 142-2 0-983 1 OD + 1 OH 144.7 127.7 0 882 Load Combinations IBC 2021 (Strength) 0.9D + 0.91-1 0.91D + 1.61-1 1.21D + 0.51- + 0.91-1 1.21D + 0.51- + 1.61-1 1.21D+1.61-+0.91-1 1.21D+1.61-+1.61-1 1.21D + 0.91-1 1.21D + 1.61-1 1.4D Stem Stem SW Stem V-applied V-allow Min.ld Actual Id (klft) (klft) (in) (in) 0.56 2.74 6 7 1 2.74 6 7 0.56 2-74 6 7 1 2,74 6 7 0.56 2.74 6 7 1 2.74 6 7 0.56 2.74 6 7 1 2.74 6 7 0 0 6 7 Heel Toe Toe Toe V-allow M-applied Wallow V-applied (klft) (ft•klft) (ft•klft) (klft) 4.54 0.27 1.89 0.14 4.54 0.27 1.89 014 4.54 0.4 1.89 0.21 4.54 0.4 1.89 0.21 4.54 0.5 1.89 0.26 4.54 0.5 1-89 0.26 4.54 0.36 1.89 0.19 4.54 0.36 1.89 0.19 4.54 0.41 1.89 0.22 M-applied (ft•kift) 0.18 0.18 0.23 0.23 0.23 0.23 0.23 0.23 0.27 Toe V-allow (klft) 4.54 4.54 4.54 4.54 4.54 4.54 4.54 4.54 4.54 Sliding Sliding Bearing Pressure Bearing Pressurearing Eccenlricillparing Eccentricity F.S. Req'd F.S. Req'd Seis... Actual Allowable Actual Allowable (psi) (psi) (in) (in) 1-500 1500 2065 2100 3 4 1 500 1 500 1627 2100 3 4 QuickRWall 5.0 (iesweb.com) C:\Users\thoma\OWDrive\T2 Consulting\2025 ...\fnd wall.rwd Page 2 of 2 Tuesday 09/23/25 10:14 AM Wall Footing (version 10) goL Client: Holding Ground Architecture Author: Theresa Thomas Project: Carbondale SFR Address: 7332 County Road 100, Carbondale, CO, USA References: ACI318-19 Summary qgo� Allowable Gross Soil Bearing Stress 5% Factored Moment Capacity 0% Factored One -Way Shear Capacity Stability Footing Properties Created with Calcs,con, Fate: Sep 9.2025 job R: 25.113 Subject: F1 Footing Width B = 1.33 ft Footing Thickness H = 8 in qa = 2000 pnt Wall Type Concrete OM = 10651b • RIR Wall Width b = 8 in OVn = 3408 plf Concrete Strength f,' = 3500 psi Volume of Concrete V = 0.0329 yd3/ft Status = Footing In Total Soil Properties Compression Allowable Soil Gross Bearing qa = 2000 psf Capacity Lateral Sliding Coefficient of = 0.3 Friction µ Bottom Reinforcement Concrete Cover cover = 3in Reinforcement Yield Strength fa = 60 000 psi Design Criteria International Design Code for Load Building Code (IBC) Combinations 2021 Sliding and Overturning FSnin = 1.5 Minimum Factor of Safety Comments Spread Footing (version 23) Created with Calcscom Client: Holding Ground Architecture Author: Theresa Thomas Project: Carbondale SFR Address: 7332 County Road 100, Carbondale, CO, USA References: ACI318-19 Summary gg% Allowable Gross Soil Bearing Stress 38% Factored Moment Capacity about X-Axis 38% Factored Moment Capacity about Y-Axis 13% Factored One -Way Shear Strength 16% Two -Way Shear Capacity 7% Concrete Bearing Capacity Development Length for X-Axis Reinforcement Design Passes as Plain Concrete (X-Axis)? Development Length for Y-Axis Reinforcement Design Passes as Plain Concrete (Y-Axis)? Uplift Safety Factor Stability 131- d4 X Bars 131-p Y-ears b=5.5 in B=24 in Footing Properties qa = 2000 psf OM_ = 3786 lb- £t OM y = 3786 lb- £t ¢V = 9087lb Ov, = 94.7 psi ¢S = 136 792 lb edx = 12 in Insufficient PCz development length but passes as plain concrete edy = 12 in Insufficient development length PCy but passes as plain concrete FS.. = Uplift has not been found Status = Footing in Total Compression Date: Sep 9, 2025 job #: 25-113 Subject: F2 IT bb=0� N Concrete Strength f,' = 3500 psi Volume of Concrete V = 0.123 yd3 Soil Properties Allowable Soil Gross Bearing 4a = 2000psf Capacity Lateral Sliding Coefficient of = 0.3 Friction jL Bottom Reinforcement Concrete Cover cover = 3in Reinforcement Yield Strength fy= 60000psi Ends of Reinforcement - X-Axis Straight Ends of Reinforcement - Y-Axis Straight Bottom Reinforcement Depth & Spacing Steel Area - X-Axis Bending Asp = 0.6 in' Steel Area - Y-Axis Bending A, = 0.6 in' Bearing Dowels Dowel Size #4 Number of Dowels nd = 4 Dowel Yield Strength fyd = 60000 psi Applied Loads Biaxial Moments Applied Separately Axial, Shear, & Moment Loads V, P, M = about X-axis Label J Location z(fi) �•=�amtrKq!Mtm1.. l wOMYJllI •p4l Dead + Occupancy 0 ff n, L S Design Criteria International Design Code for Load Building Code (IBC) Combinations 2021 Negative Bending Flexural Capacity - X-Axis (ACI 318-19, Cl 22.2) p% Factored Negative Moment ¢M,� = 3786 lb • ft Capacity Negative Bending Flexural Capacity -Y-Axis (ACI318-19, Cl 22.2) 0°� Factored Negative Moment OMny = 3786lb•ft Capacity Column -Footing Interface Capacity (ACI 318-19, Cl 22,8) a` E m A o h m m r ti m L N w E in y 3 « N d —_ c c E tl y c S � E � ° g a =cc oo 0 c000c 0 0 0 0 o d 0 0 •o 0 v n n n o 0 0 0 0 •o 0 0 0 Q o 0 0 0 0 0 c x o o 0 0 m m n s n h � a =.00 a y o 0 0 00 0 0 0 00 oc 0 c 0 � 0 0 0 0 0 n m m m m m rci rci m n m m o 0 o d 0 o 0 0 0 0 0 0 0 0 0 0 0 0 O O m m � c ° C y t H O O d o o r m N p1 u 'a e a 1D n m in a —�m„ a a M n �R m m vLl a a a a mco � o 'o rlry N N a m N iOfl w m o o w eo N o m o oo ao c o i° m e Io ao of � m IN a 3 `v a J m4 vi �n 4m c rvno a oti � m — 0 r o 0 •a :^ C1 pp N qE 1,4 N NQ O .N O N o N ~-I ei O N °1 N OI •m N a m 0 n m m m m o 0 0 0 0 N 0 0 N x o •o 0 0 0 o W �++ ,o m m m C � ino oC O m 00 vi oG o �n O 00 m m •o m m m e o a m❑ a m o °o z G N w 3 L 0 Z x o w 3 � x 30 O O O p 0 0 03; O�; 3; .p d Z Z Z O Z O o :L # # # ` rr�no M000 > > -a- �oN�O W ❑00 E n O O o 0 o o r a O 0 o 0 0 0 'K a W l00 00 0 IY o W �n �yo ug Coo a M 0 .000 M N 0 O 0 O O O O .00. N N m 0 0 d o o �- O � 0 0 0 M co) u) Eo# (n F n ### Q N n 0 0❑ >> > 0 0❑ 7 d O n N m O N> Or1»> m O 0 0 0 0 Q Y # # # # 0 a 0000 O O O J a 0 Q � yamy_ 7 0 O O O O 0000 O F LL L � >U > O O O O O 0000 O _ ir F S W W W O .000 3v m m N o N O J O w N o a r W O m 0 0 W O O o W = T V r W O .0 0 00 IA N 0 0 0 0 0 0 0 --coo - N C D O �C7 L7 ON L o 1- o ei ai E m mp din Z o d E E r c o o d N d E�€ a <<a N m 3 E m v •3gq c o$p�� - d 'm -E Z F � E Ol 3� } w Vl A d N L L a N O =3m i a c v H � S— % C 10 0 t ni J v E E L _ N O 4$ O IL C rL n a u Ov �� II go G ixxLc LL Ac 'n SNry d v2 v2 LL O w �wy N U n n d d 10 N 6 o u O m 0 a � a ��c mOC II II $gym E..° ❑o o p Z d _ C1 U O jC =5 t 1 J O yN d K yy a` d FAN C 3� p 9 o_o__o O > > > 00 N d >_ >_ 0000 O >_ >_ >_ > p d Z 0 0 0 }} Z 0 0 0❑ k 0 0 0 O) �e n o > > > m > > o > > > > n- O O cl❑ W m 0 0 0 0 0 # # # # # # E n 0 0 0 0 0 0 0 0 0 0 0 0 0 zCoco 0000 00000 � a x IY a -.0. C) 0 0 0 1.00 C 1 C J O O .0000 O O O o y 0 0 0 0 0 0 0 0 IH 0 0 0 0 o m 0 0 o m o o 0 0 jy N 0 0 0 N CJ O O N Coco m . > � 0 0 0 0 rn000 rn to 0� y0000 - n ft Ilk p C pl N O O O > >> N N E,O M O O O O m> >>> 3 of � C6 Qd� L N # # # N N # # # # # # m > > > N p 00 >_ >_ m rn 0 0 rn 0 0 00 C 7 # # # N N # d 0 a 0 0 o 7 > > > W O 0 0 O O > > m o 0 o 0 10 S > > 1 M o # # # # � a J O O O O O O O O O O O O O 0 L a F � O! 00 O 00 00 O 00 00 a O C LL L S r 7 O 0000 O O m m m m m m M m V O O O O O a al� � � � c2 a- 2 - X 0000 Ol W O) O .0000 C 0 0 0 0 o O O O m 0 0 0 0 m 0 0 0 0 00000 O O O O ,r d 1000N W m 0 0 �2 O O O O W 6 N �O O O O -w W 0 0 0 w o m o 0 - V W O O A I� O O O O CCI CO 0 0 0 0 v I N 0 0 0 M N 0 0 0 NNOCCO Nm � rNMv rNov aln � p a L7 L7 L7 3 n o 0 0 0 0_ 0 0 N a Q N>>> 1 > Z= > Z mo _ 0000 m0oo g000 00 n� v### NUU❑ �UU❑ NCO❑ va w L) 7 ### ### E E.r _ - m y E a c S N O O 0000 0000 ESE b - - a`9 Y _ o T .00. coo. m 0 0 0 0- p LL. p n 0 0 0 N O O m -000 a0000 ui000 -oE � m CO •R O. H p O O O 0000 o 0 0 No 00 00. a Z F O j y .000 M 0 0 0 O) 0 0 0 - � i • � o 0 0 � o 0 0 � o 0 0 >> >> > >> } O y # # # # # # # m c F # # w= O N t L N O O O p O_ OCi N O O O 0 N i a v N O O O O N 0 0 0 `y»> a 0 0 0 fO»> aM a m p p ro � •7 3 w �. T 0 0 M O O D y n$ a J p 0 M > % > O '0 0 > > > r > > > 10 o3 OO 6 5 E 5 OooIn ry �2 J a :o p 0000 O O O O 0000 7 n N c � O � .>O O O O O O O O O O O O O n O ` LL Fo J@J @J � D m 0 > M 0 0 0 N O O O M O O D O a 0 LL im In `nL I� m000 m000 m000 U n n ai I; wof 0 0 0 o O O O O O 00000 , O O O D 0 0 0 0 0 0 0 u � c O �a C m c0000�0 �000� �000� eom N U _ — O J J O D - x V 0 0 0 ..coo V 0 0 0 mmm w W O_ ip Y 0 0 0 --coo c — 0 0 0 ___ 1 J O y •- N M� �N dlv �-N M 7 m R a �yy u O O LL C 3 0 0 O N N N N L E 0000 coo 00 n O 6 0 0 0 0 0 0 0 0 0 m M M n n 'y a v o o O N O O m N (V m M 0 0 O0 M N 0 0 0 0 m m r r m N 7 w (A) V7 (4 fn CO •n C --cc m m 4 >> rn rn rn M N N a--cc -- m m V] C >> m m m m M [3 M M N N o o m Mm M O O tmp 0� W O w m ri�pp o�� Sri egm n v� 0000 000 q q J O t `O 0000 N O O cc � o Y LL V r 0 0 N N N N A O m m O O m m m c0 m L C_ 000.0 n N 0 0 0 O O O O 0 0 0 IO O m N O N m N 0 o O m b b N M N N o� m In O Nmm W n lV 0— 0 0 V (V 0 0 O •- IN v a tee r9 ei Cf SUMMARY REPORT ii�I F R T E Vlr' E B OB 13 Carbondale SFR & ADU 08/25 SFR Member Name Results (Max UTIL %) Current Solution Comments R11 - Low Roof Passed (65% R) 1 piece(s) 14" TJIO 560 @ 24" OC RJ2 - Upper Roof Passed (70% R) 1 piece(s) 11 7/8" TJIO 560 @ 24" OC H1 - Upper Windows Grid 4 Passed (69% AT) 2 piece(s) 1 3/4" x 5 1/2" 2.0E Microllam0 LVL F31 -Grid B - D Passed (72% AL) 1 piece(s) 11 7/8" TJIO 560 @ 16" OC H2 - 6-6 U.L. hdr Passed (92% M) 2 piece(s) 2 x 10 DF N0.2 H3 - 3' U.L. hdr Passed (51% M) 2 piece(s) 2 x 6 DF No.2 H4 - 6-6 U.L. hdr GABLE Passed (38% M) 2 piece(s) 2 x 8 DF N0.2 FB2 - Stairway Floor Header Passed (14% R) 2 piece(s) 1 3/4" x 11 7/8" 2.0E Microllam0 LVL H5 - LL 6' kitchen Passed (79% M) 2 piece(s) 2 x 10 DF N0.2 H6 - LL 3' kitchen Passed (51% M) 2 piece(s) 2 x 6 DF No.2 FB3 - Grid D Passed (31% R) 1 piece(s) 5 1/8" x 12" 24F-V4 DF Glulam FB4 - Grid 2 UL Passed (73% AL) 1 piece(s) 5 1/8" x 18" 24F-V4 DF Glulam H7 - Grid 3 Slider Passed (80% AT) 2 piece(s) 1 3/4" x 7 1/4" 2.0E Microllam0 LVL H8 - Grid B doorway Passed (54% M) 2 piece(s) 2 x 6 DF No.2 H9 - Grid 4 window Passed (65% M) 2 piece(s) 2 x 6 DF No.2 F32 - Grid 2-4 Passed (58% AL) 1 piece(s) 11 7/8" TJIO 360 @ 16" OC RJ3 - Entryway Passed (56% M) 1 piece(s) 2 x 8 DF No.1 @ 24" OC H10 - Garage Door Passed (33% AT) 2 piece(s) 1 3/4" x 9 1/2" 2.0E Microllam0 LVL F33 - LL Joists Passed (51% R) 1 piece(s) 11 7/8" TJIO 560 @ 16" OC FB5 - Grid 3 LL Passed (35% R) 1 piece(s) 5 1/8" x 12" 24F-V4 DF Glulam F34 - Deck Joist Passed (51% M) 1 piece(s) 2 x 8 DF No.2 @ 16" OC FB6 - Grid B+ Passed (93% OL) 1 piece(s) 3 1/8" x 7 1/2" 24F-V4 DF Glulam DECK FLUSH BEAM Passed (93% M) 2 piece(s) 2 x 8 DF No.2 Outlooker Passed (80% M) 1 piece(s) 2 x 4 DF No.2 @ 24" OC Outlooker Support Bm Passed (52% R) 1 piece(s) 11 7/8" TJIO 560 ForteWEB Software Operator Job Notes Tracy Thomas T2 Consulting, LLC (206) 200-4853 thomasa nn tacy@g mai I.co m 9/23/2025 3:51:34 PM UTC ForteWEB v3.9 Weyerhaeuser File Name: 25-113 Carbondale SFR & ADU Page 1 / 31 -J F O R T E W E B Trus Joist® Construction Detail Report 25-113 Carbondale SFR & ADU Toe nail, (0.131" x 3") at 6" on -cent When sheathing thickness exceeds?B", trim sheathing tongue at rim board t Plate nail, (0:131" x 3") at 12" on -center' (4" on -center for braced walls) Floor panel nail - �- 8d (0.131" x 2 )i") at 6" on -center' Web Stiffeners required each side at A3. W f --1 ?'8" TJ" Rim Board (with depths <_ 16"), (A3.1/A3.1W only) 1 �,4" or 1 Y' TimberStrand" LSL. Tm nail - (0.131" x 3") at 6" ` on -center' f All I""l Attach blocking per Rim Board Details and Installation in Weyerhaeuser 1 A3 1 CA3�1] A3.2 CA-3:1)3Installation Guide for Floor and Roof Framing, TJ-9001. \/ �� ^ '' For A3.1-A3.3 installation specifications see Rim Board �3,11 A3.2 rA3.3 Details and Installation in Weyerhaeuser Installation A3Wf I W) Guide for Floor and Roof Framing, TJ-9001. W \\ Plate nail, (0.131" x 3") at 12" on-centerK' on -center for braced walls) eking panel: 1 1/6" TJ" Rim Board i depths15 16"), ' or 1 ?iz" TimberStrand° LSL JI" joist Web stiffeners required on both sides at Al W ONLY Shear blocking: 1 !/8' TJ® Rim Board (with depths <_ 16"), 1 !/4'or 1 1T TimberStrand® LSL or TJI® joist i I Web Stiffener required on both sides at R1 W ONLY Beveled bearing plate required I ?'3 member length or?'z backspan maximum DRI R 01�W WEB STIFFENER ATTACHMENT a minimum 1„ 23h" maximum (1 2"for TJI. Nailing: 560, 560D) • See table below. T. 'i Web stiffener both sides - See table below. ' With point load from above, and no support j below, install web stiffener tight to tap flange t Tiaht fit' rewn ar noaoman�s Depth Minimum Web Nailing Requirements _ Number Type End ] Na Is - Intermediate TJI® Joist Series (in.) Stiffener Size 110 AN se" x 2 s'is"", 8d 210 230 & 360 AN 3Q" x 2 5i6""' All ?-e" x 2 siic' " 0.113" x 2 ?Z") ( 3 16d I 3 560 AS 2x4 p1 0.135" x 3 18" 4 4 S60D 20" y 22„. 2x4 16d 5 (0, 135"x3?z') 6 5 11 24"M 6 13 `- (1) PS1 or PS2 sheathing, face grain vertical W J (2) Construction grade or better y (3) Web stiffeners are always required for 22" and 24" TJI0 560D Joists ForteWEB Software Operator Job Notes Tracy Thomas T2 Consulting, LLC (206) 200-4853 thomasanntracy@gmail.com 9/23/2025 3:51:34 PM UTC ForteWEB v3.9 Weyerhaeuser File Name: 25-113 Carbondale SFR & ADU Page 2 / 31 oa FORTE W E B MEMBER REPORT PASSED 08125 SFR, RJ2 - Upper Roof REV 1 - SHEET REVISED i piece(s) 11 7/8" TJI@ 560 @ 24" OC 11 /7/2025 Sloped Length: 18' 3" 12 2F E! � 18' .0 Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1119 @ IT 6 1/2" 1455 (1.75") Passed (77%) 1.15 1.0 D + 1.0 S (All Spans) Shear (Ibs) 1119 @ 17 6 1/2" 2358 Passed (47%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 4804 @ 8' 11 1/2" 10925 Passed (44%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.372 @ 8' 11 1/2" 0.580 Passed (L/561) -- 1.0 D + 1.0 S (All Spans) Total Load Defl.(in) 0.486 @ 8' 11 1/2" 1 0.870 Passed (L/430) - 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. Supports Bearing Length Loads to Supports (Ibs) Accessories Details Total Available Required Dead Snow Factored 1 - Beveled Plate - DF 5.50" 5.50" 1.75" 272 896 1168 Blocking R1 2 - Hanger on 11 7/8" DF beam 5.50" Hangers 1.75" / - z 275 904 1179 See note s • Blocking Panels are a5sulro to carry no loads applied directly above them and the full Wad Is apPlted to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • s See Connector grid below for additional information and/or requirements. • Required Bearing Length / Required Bearing Length with Web Stiffeners Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 8' 1" o/c Bottom Edge (Lu) 179" o/c •TJI joists are only analyzed using Maximum Allowable bracing solutions. -Maximum allowable bracing intervals based on applied load. -Dimensions for lateral bracing intervals are measured along the length of the member for sloped conditions. Member Length : 17' 11 3/8" System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Member Pitch : 2/12 Connector: Simpson Strong -Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Top Mount Hanger BA3.56/11.88X SLD9 3.00" 6-10dx1.5 I4-10dx1.5 2-10dx1.5 • Refer to manufacturer notes and instructions for proper installation and use of all connectors. Vertical Load Location Spacing Dead (0.90) Snow L mments 1 - Uniform (PSF) 0 to 18' 24" 15.0 50.0 A Default Load We erhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document -library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Tracy Thomas T2 Consulting, LLC (206)200-4853 thomasanntracy@gmail.com 11/7/2025 8:49:53 PM UTC ForteWEB 0.9, Engine: V8.4.3.94, Data: V8.1.7.3 Weyerhaeuser File Name: 25-113 Carbondale SFR & ADU Page 4 / 12 4 FORTE W E B MEMBER REPORT PASSED REV 1 -SHEET REVISED 11 /7/2025 12 21 08125 SFR, R13 - Entryway 1 piece(s) 2 x 8 DF No.1 @ 24" OC Sloped Length: 8' 7 7/16" MAWMMW 8' 6" Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 554 @ 2 1/2" 2231 (3.50") Passed (25%) - 1.0 D + 1.0 S (All Spans) Shear (Ibs) 439 @ 10 5/8" 1501 Passed (29%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 1065 @ 4' 3" 1738 Passed (61%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.122 @ 4' 3" 0.410 Passed (L/807) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.159 @ 4' 3" 0.546 Passed (L/618) - 1.0 D + 1.0 S (All Spans) • Deflection criteria: ILL (L/240) and TL (L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. • A 15% increase in the moment capacity has been added to account for repetitive member usage. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total I Available Required Dead Snow Factored 1 - Beveled Plate - SPF 3.50" 3.50" 1.50" 129 425 554 Blocking 2 - Beveled Plate - SPF 3.50" 3.50" 1.50" 129 425 554 Blocking • Blocking Parcels are assumed to carry no loads applied directly above them and me tuli load is applied to the member being dmigrim. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 8' 7" o/c Bottom Edge (Lu) 8' 7" o/c -Maximum allowable bracing intervals based on applied load. -Dimensions for lateral bracing intervals are measured along the length of the member for sloped conditions. _WN Vertical Load Location (Side) Spacing Dead 1 (0.90) Snow Comments 1 - Uniform (PSF) 0 to 8' 6" 24" 15.0 50.0 Default Load Member Length : 8' 8 5/8" System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Member Pitch : 2/12 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and puhlished design values, Weyerhaeuser expressly disclalms arty other warranties related to the software. Use of this software Is not Intended to circumvent the need for a design profess"I as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation Is rompabble with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR 1153 and ESR4387 and/or tested in accordance with applkable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details rerer to www.v&Whaeusercom/wdodproductsl document -library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Tracy Thomas T2 Consulting, LLC (206)200-4853 thomasanntracy@gmail.com 11/7/2025 8:49:53 PM UTC ForteWEB v3.9, Engine: V8.4.3.94, Data: V8.1.7.3 Weyerhaeuser File Name: 25-113 Carbondale SFR & ADU Page 8 / 12 ea FORTEW EB MEMBER REPORT PASSED REV 1 -SHEET REVISED 11 /7/2025 08125 SFR, RJl - Low Roof 1 piece(s) 14" TJI® 560 @ 24" OC Sloped Length: 21' 3 112" OAW 12 2� 21' in ❑2 Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1369 @ 5 1/2" 1984 (3.50") Passed (69%) 1.15 1.0 D + 1.0 S (All Spans) Shear (Ibs) 1299 @ 6 1/2" 2749 Passed (47%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 6575 @ 10' 6" 12966 Passed (51%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.472 @ 10' 6" 1.018 Passed (L/518) - 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.616 @ 10' 6" 1 1.357 Passed (L/397) - 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. Supports Bearing Length Loads to Supports (Ibs) Accessories Details Total Available Required Dead Snow Factored 1 - Beveled Plate - DF 6.50" 6.50" 1,75" 319 1050 1369 Blocking R1 2 - Beveled Plate - DF 6.50" 6.50" 1.75" 319 1050 1369 Blocking R1 • Blocking Panels are assumed to carry no loads applied directly a0eve them and the run ioaa is appima to the memoer oemy uesiyiieu. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 7' 6" o/c Bottom Edge (Lu) 21' 3" o/c •TJI joists are only analyzed using Maximum Allowable bracing solutions. -Maximum allowable bracing intervals based on applied load. -Dimensions for lateral bracing intervals are measured along the length of the member for sloped conditions. Vertical Load Location Spacing Dead (0.90) Snow [ 15) Comments 1 - Uniform (PSF) 0 to 21' 24" 15.0 50.0 Default Load Member Length : 21' 5 13/16" System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Member Pitch : 2/12 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be In accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software Is not Intended to circumvent the need for a design profes0orwl as determined by the authority having judsdiction. The designer of record, builder or framer is responsible to assure that this calculation Is compadble with the overall project. Accessories (Rim Board, Blocking Panels and Squash Slacks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are thlyd•party certified to sustalnahie forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by 1CC-ES under evaluation reports ESR 1153 and MR-1387 and/or tested In accordance with applicable ISTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation detalls refer to www.weyerhaeuserwm/woodproducts/ document -library. product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Tracy Thomas T2 Consulting, LLC (206) 200-4853 thomasanntracy@gmail.com Job Notes I 11/7/2025 8:49:53 PM UTC ForteWEB v3.9, Engine: V8.4.3.94, Data: V8.1.7.3 Weyerhaeuser File Name: 25-113 Carbondale SFR & ADU Page 3 / 12 l FO RTE W E B MEMBER REPORT PASSED REV 1 - SHEET REVISED 11 /7/2025 08125 SFR, H2 - 6-6 U.L. hdr 2 piece(s) 2 x 10 DF No.2 Overall Length: 7' 61' 0 Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 2527 @ 1 1/2" 5625 (3.00") Passed (45%) -- 1.0 D + 1.0 S (All Spans) Shear (Ibs) 1790 @ 1' 1/4" 3830 Passed (47%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 4112 @ 3' 6" 4059 Passed (101%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.081 @ 3' 6" 0.225 Passed (L/998) - 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.107 @ 3' 6" 0.338 1 Passed (L/760) 1.0 D + 1.0 S (All Spans) • Deflection criteria: ILL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Snow Factored 1 - Trimmer - SPF 3.00" 3.00" 1.50' 602 1925 2527 None 2 - Trimmer - DF 3.00" 3.00" 1.50" 602 1925 2527 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 6" o/c Bottom Edge (Lu) 7' o/c -Maximum allowable bracing intervals based on applied load. Dead Snow Vertical Loads Location (0.90) (1.1S) Carom Width Width 0 - Self Weight (PLF) 0 to 7' N/A 7.0 1 - Uniform (PSF) 0 to 7' 11' 15.0 50.0 ult Load El Member Length : 7' System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes `" `-- - Weyerhaeuser warrants that the sizing of Its products will be in aceordaiue with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not interlded to circumvent the need for a design professional as determined by the authority having jurisdlctfon. The designer of record, builder or framer Is responsible to assure that this calculation Is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manvfaaumd at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and 5R-1387 and/or tested in accordance with applicable A5TM standards. For current code evaluation reports, Weyerhaeuser product literature and RmItallation details refer to www.weyedoeiiser.com/woodproducw document -library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Tracy Thomas T2 Consulting, LLC (206)200-4853 thomasanntracy@gmail.com 11/7/2025 8:49:53 PM UTC ForteWEB v3.9, Engine: V8.4.3.94, Data: V8.1.7.3 Weyerhaeuser File Name: 25-113 Carbondale SFR & ADU Page 5 / 12 IFORTEWER PASSED REV 1 - SHEET REVISED 11 /7/2025 MEMBER REPORT 08125 SFR, H3 - 3' U.L. hdr 2 piece(s) 2 x 6 DF No-2 Overall Length: 3' 3" + 0 3' ] Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1169 @ 0 2813 (1.50") Passed (42%) -- 1.0 D + 1.0 S (All Spans) Shear (Ibs) 749 @ 7" 2277 Passed (33%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 950 @ 1' 7 1/2" 1696 Passed (56%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.021 @ 1' 7 1/2" 0.108 Passed (L/999+) -- 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.027 @ 1' 7 1/2" 0.162 1 Passed (L/999+) - 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Snow Factored 1 - Trimmer - OF 1.50" 1.50" 1.50" 275 1 894 1169 None 2 - Trimmer - OF 1.50" 1.50" 1.50" 275 894 1169 (None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) T 3" o/c Bottom Edge (Lu) T 3" o/c -Maximum allowable bracing intervals based on applied load. Dead Snow Vertical Loads Location Tributary (0.90) (1.1s) Comm Width 0 - Self Weight (PLF) 0 to 3' 3" N/A +2 1 - Uniform (PSF) 0 to 3' 3" 11' 15.0 50.0 Default Load ME] 0 Member Length : 3' 3" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to clrcumyent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document -library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Tracy Thomas T2 Consulting, LLC (206)200-4853 thomasanntracy@gmail.com 11/7/2025 8:49:53 PM UTC ForteWEB v3.9, Engine: V8.4.3.94, Data: V8.1.7.3 Weyerhaeuser File Name: 25-113 Carbondale SFR & ADU Page 6 / 12 f FORTE W E B MEMBER REPORT PASSED 08/25 SFR, R11 - Low Roof w/ drift SL 1 piece(s) 14" TJI@ 560 @ 24" OC 12 2F 0 Sloped Length- 21' 3 1.2" em ❑2 Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 2062 @ 5 1/2" 2530 (3.50") Passed (82%) 1.15 1.0 D + 1.0 S (All Spans) Shear (Ibs) 1956 @ 6 1/2" 2749 Passed (71%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 9903 @ 10' 6" 12966 Passed (76%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl.(in) 0.784 @ 10' 6" 1.018 Passed (L/312) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.927 @ 10' 6" 1.357 Passed (L/263) 1.0 D + 1.0 S (All Spans) • Deflection criteria: ILL (L/240) and TL (L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. Supports Bearing Length Loads to Supports (Ibs) Accessories Details Total Available Required Dead Snow Factored 1 - Beveled Plate - DF 6.50" 6.50" 1.96" 319 1743 2062 Blocking, Web Stiffeners R1W 2 - Beveled Plate - DF 6.50" 6.50" 1.96" 319 1743 2062 Blocking, Web Stiffeners R1W • Blocking Parcels are assumed to carry no loads applied directly above them and the full load is applied to the member being oeagrma. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 511" o/c Bottom Edge (Lu) 21' 3" o/c •TJI joists are only analyzed using Maximum Allowable bracing solutions. -Maximum allowable bracing intervals based on applied load. -Dimensions for lateral bracing intervals are measured along the length of the member for sloped conditions. Vertical Load Location Spacing Dead (0,90) Snow (1.15) Comments 1 - Uniform (PSF) 0 to 21' 24" 15.0 83.0 Default Load Member Length : 21' 5 13/16" System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Member Pitch : 2/12 Weyerhaeuser warrants that the sizing of its products will be In accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly dlsxdalms any other warranties related to the software. Use of this software Is not Intended to circumvent the need for a design professional as determined by the authority having Jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software- Products manufactured at Weyerhaeuser facilities are third -party ceftiW to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by [OC-M under evaluation reports FSR 1153 and ESP-1397 and/or tested in accordance with applicable AST M standards. For current code evaluation reports, Weyerhaeuser product literature and Installation detal6 refer to www.wey8rhaeusercom/woodprodticw document -library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Tracy Thomas T2 Consulting, LLC (206) 200-4853 thomasanntracy@gmail.com 11/7/2025 8:49:53 PM UTC ForteWEB v3.9, Engine: V8.4.3.94, Data: V8.1.7.3 Weyerhaeuser File Name: 25-113 Carbondale SFR & ADU Page 11 / 12 l FO RTE W E B MEMBER REPORT PASSED 08125 SFR, HI - Upper Windows Grid 4 2 piece(s) 1 3/4" x 5 1/2" 2.0E Microllam@ LVL L 7 y 0 0 Overall Length: 25' 1/2" g� o 0 ❑3 0 ❑a Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 4491 @ 7' 6" 7613 (3.00") Passed (59%) — 1.0 D + 1.0 S (Adj Spans) Shear (Ibs) 2053 @ 6' 11" 4206 Passed (49%) 1.15 1.0 D + 1.0 S (Adj Spans) Moment (Ft-Ibs) -3074 @ 76" 4889 Passed (63%) 1.15 1.0 D + 1.0 S (Adj Spans) Live Load Defl. (in) 0.166 @ 3' 7 1/8" 0.242 Passed (L/524) — 1.0 D + 1.0 S (Alt Spans) Total Load Defl. (in) 0.217 @ 3' 6 3/4" 0.313 Passed (L/402) - 1.0 D + 1.0 S (Alt Spans) • Deflection criteria: LL (L/360) and TL (5/16"). • Allowed moment does not reflect the adjustment for the beam stability factor. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Roof Live Snow Factored 1 - Trimmer - DF 4.50" 4.50" 1.50" 439 583 1284 17Z3 None 2 - Trimmer - SPF 3.00" 3.00" 1.77" 1173 1507 3317 1 4491 None 3 - Trimmer - SPF 3.00" 3.00" 1.50" 799 1140 2508 3308 None 4 - Trimmer - SPF 3.00" 3.00" 1.50" 821 1112 2448 3268 None 5 - Trimmer - DF 3.00" 1 3.00" 1 1.50" 1 309 1 419 922 1231 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 25' 1" o/c Bottom Edge (Lu) 21' 6" o/c -Maximum allowable bracing intervals based on applied load. Dead Roof Live Snow Vertical Loads Location Tributary (0.90) (1.25) (1.15) Comments Width 0 - Self Weight (PLF) 0 to 25' 1/2" N/A 5.6 — Linked from: RJ2 - 1 - Uniform (PLF) 0 to 25' N/A 136.0 179.0 394.0 Upper Roof, Support 1 Member Length : 25' 1/2" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document -library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Tracy Thomas T2 Consulting, LLC (206)200-4853 thomasanntracy@gmail.com 9/23/2025 3:51:34 PM UTC ForteWEB v3.9, Engine: V8.4.3.94, Data: V8.1.7.3 Weyerhaeuser File Name: 25-113 Carbondale SFR & ADU Page 5 / 31 1FORTEWEB MEMBER REPORT 08125 SFR, F84 - Grid 2 UL 1 piece(s) 5 1/8" x 18" 24F-V4 DF Glulam PASSED 0 0 Overall Length: 22' 2Z + 0 0 Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 6242 @ 6 1/2" 22486 (6.75") Passed (28%) — 1.0 D + 1.0 S (All Spans) Shear (Ibs) 5061 @ 2' 2" 18742 Passed (27%) 1.15 1.0 D + 1.0 S (All Spans) Pos Moment (Ft-Ibs) 31332 @ 11' 61148 Passed (51%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.382 @ 11' 0.523 Passed (L/657) -- 1.0 D + 1.0 5 (All Spans) Total Load Defl. (in) 0.550 @ 11' 1.046 Passed (L/456) — 1 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/480) and TL (1-/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Volume factor of 0.96 was calculated for positive bending using length L = 20' 11". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. Member Length : 21' 9 1/2" System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Supports Bearing Length Loads to Supports (Ibs) Accessories Total I Available Required Dead Floor Live Roof Live Snow Factored 1 - Column Cap - steel 8.00" 6.75" 1.87" 1922 440 1991 4378 6300 1 1/4" Rim Board 2 - Column Cap - steel 8.00" 1 6.75" 1.87" 1922 440 1991 4378 6300 1 1/4" Rim Board • ram WHIM is assumed to carry au iodo5 aPPueu u"euiy duuve a, uyPd» l iy u U nIU+Auei ucwy u�y� ieu. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 21' 10" o/c Bottom Edge (Lu) 21' 10" o/c -Maximum allowable bracing intervals based on applied load. Dead Floor Live Roof Live Snow Vertical Loads Location (Side) Tributary (0.90) (1.00) (1.25) (1.15) Comments Width 0 - Self Weight (PLF) 1 1/4" to 21' 10 3/4" N/A 22.4 — — 1 - Uniform (PSF) 0 to 22' (Front) 1' 15.0 40.0 — Default Load Linked from: RJ2 - 2 - Uniform (PLF) 0 to 22' (Top) N/A 137.5 — 181.0 398.0 Upper Roof , Support 2 • 5itie Ioaa are assumed to not induce cross -grain tension. We erhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document -library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Tracy Thomas T2 Consulting, LLC (206) 200-4853 thomasanntracy@gmail.com 9/23/2025 3:51:34 PM UTC ForteWEB v3.9, Engine: V8.4.3.94, Data: V8.1.7.3 Weyerhaeuser File Name: 25-113 Carbondale SFR & ADU Page 15 / 31 4FORTEWEB 0 MEMBER REPORT 08125 SFR, FB2 - Stairway Floor Header 2 piece(s) 1 3/4" x 11 7/8" 2.0E Microllam® LVL Overall Length: 4' 1" 3. 6" Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 551 @ 3 1/2" 3938 (1.50") Passed (14%) — 1.0 D + 1.0 L (All Spans) Shear (Ibs) 239 @ 1' 3 3/8" 7897 Passed (3%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 482 @ 2' 1/2" 17848 Passed (3%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.002 @ 2' 1/2" 0.087 Passed (L/999+) — 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 0.002 @ 2' 1/2" 0.175 1 Passed (L/999+) - 1.0 D + 1.0 L (All Spans) • Deflection criteria: LL (L/480) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Factored 1 - Hanger on 11 7/8" SPF beam 3.50" Hangers 1.50" 190 449 639 See note s 2 - Hanger on 11 7/8" SPF beam 3,50" Hangers 1.50" 190 449 639 See note' • At hanger supports, the Total Bearing dlmenslon Is equal to the width of the material that is supporting the hanger • s See Connector grid below for additional information and/or requirements. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 3' 6" o/c Bottom Edge (Lu) 3' 6" o/c -Maximum allowable bracing intervals based on applied load. PASSED Member Length : 3' 6" System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Connector: Simpson Strong -Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 1 - Face Mount Hanger LUS410 2.00" N/A 8-10dx1.5 6-10d 2 - Face Mount Hanger LUS410 2.00" N/A 8-10dx1.5 6-10d • Refer to manufacturer notes and instructions for proper installation and use of all connectors. Dead Floor Live Vertical Loads Location (Side) Tributary Width (0.90) (1.00) Comments 0 - Self Weight (PLF) 3 1/2" to 3' 9 1/2" N/A 12.1 — 1 - Uniform (PSF) 0 to 4' 1" (Front) 5' 6" 15.0 40.0 Default Load • Side loads are assumed to not induce rross-grain tension. Weyerhaeuser warrants that the sizing of its, products will be in accordarice with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeusercom/woodproducts/ document -library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Tracy Thomas T2 Consulting, LLC (206) 200-4853 thomasanntracy@gmail.com 9/23/2025 3:51:34 PM UTC ForteWEB v3.9, Engine: V8.4.3.94, Data: V8.1.7.3 Weyerhaeuser File Name: 25-113 Carbondale SFR & ADU Page 10 / 31 �;i FORTEWER MEMBER REPORT PASSED 08125 SFR, FB3 - Grid D 1 piece(s) 5 1/8" x 12" 24F-V4 DF Glulam Overall Length: 17' 10" 0 R 1 b 6' L 7' Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result iLDF Load: Combination (Pattern) Member Reaction (Ibs) 5775 @ 6' 8 1/4" 18322 (5.50") Passed (32%) — 1.0 D + 0.75 L + 0.75 S (Adj Spans) Shear (Ibs) 1896 @ 7' 11" 10865 Passed (17%) 1.00 1.0 D + 1.0 L (Adj Spans) Pos Moment (Ft-Ibs) 2386 @ 2' 11 3/4" 24600 Passed (10%) 1.00 1.0 D + 1.0 L (Alt Spans) Neg Moment Ft-Ibs) -3567 @ 6' 8 1/4" 18963 Passed (19%) 1.00 1.0 D + 1.0 L (Adj Spans) Live Load Defl. (in) 0.009 @ T 3 9/16" 0.159 1 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (Alt Spans) Total Load Defl. (in) 0.011 @ T 2 5/8" 0.318 1 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (Alt Spans) • Deflection criteria: LL (L/480) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Volume factor of 1.00 was calculated for positive bending using length L = 5' 3 7/16". • Volume factor of 1.00 was calculated for negative bending using length L = 3' 3 7/16". • -229 Ibs uplift at support located at 17' 6". Strapping or other restraint may be required. • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Snow Factored 1 - Column - DF 5.50" 4.25" 1.50" 649 1382/-143 583 2122 1 1/4" Rim Board 2 - Column - DF 5.50" 5.50" 1.73" 1911 3553 1598 5775 None 3 - Column - DF 5.50" 5.50" 1.50" 1495 3064 1315 4780 None 4 - Column - DF 5.50" 4.25" 1.50" 234 941/-463 311/-7 1175/-229 1 1/4" Rim Board • Rim Board is assumed to carry all loads applied directly above It, bypassing the member being designea. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 17' 8" o/c Bottom Edge (Lu) 17' 8" o/c -Maximum allowable bracing intervals based on applied load. Dead Floor Live Snow Vertical Loads Location (Side) Tributary (0.90) (1.00) (1.15) Comments Width 0 - Self Weight (PLF) 1 1/4" to 17' 8 3/4" N/A 14.9 1 - Uniform (PSF) 0 to 17' 10" (Front) 4' 15.0 50.0 2 - Uniform (PLF) 0 to 17' 10" (Front) N/A 165.8 441.8 Linked from: Floor: Joist, Support 1 • Side loads are assumed to not induce cross -grain tension. ForteWEB Software Operator Weyerhaeuser Job Notes Tracy Thomas T2 Consulting, LLC (206) 200-4853 thomasanntracy@gmail.com Member Length : 17' 7 1/2' System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD 11/7/2025 9:04:54 PM UTC ForteWEB v3.9, Engine: V8.4.3.94, Data: V8.1.7.3 File Name: 25-113 Carbondale SFR & ADU Page 1 / 2 4 FO RT E W E B MEMBER REPORT PASSED 08125 SFR, H4 - 6-6 U. L. hdr GABLE 2 piece(s) 2 x 8 DF No.2 Overall Length: 7' 5161, Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 702 @ 1 1/2" 5625 (3.00") Passed (12%) — 1.0 D + 1.0 S (All Spans) Shear (Ibs) 531 @ 10 1/4" 3002 Passed (18%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 1142 @ 3' 6" 2720 Passed (42%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.046 @ 3' 6" 0.225 Passed (L/999+) -- 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.061 @ 3' 6" 0.313 Passed (L/999+) - 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (5/16"). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total I Available Required Dead Snow Factored 1 - Trimmer - SPF 3.00" 3.00" 1.50" 177 525 702 (None 2 - Trimmer - DF 3.00" 3.00" 1.50" 177 525 702 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 7' o/c Bottom Edge (Lu) 7' o/c -Maximum allowable bracing intervals based on applied load. Dead Snow Vertical Loads Location Tributary (0.90) (1.15) Comments Width 0 - Self Weight (PLF) 0 to 7' N/A 5.5 1 - Uniform (PSF) 0 to 7' 3' 15.0 50.0 Default Load Member Length : 7' System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the siring or Its products will be In accordance with Weyerhaeuser product design criteria and published design values, Weyerhaeuser expressly disclalms any Other warranties related to the saftware. Use of this softvuare Is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation Is compatible watt the overall pro)ect. Accessories (Rim Board, Bipcking Panels and Squash Blocks) are not designed by this software. Products manufattured at Weyerhaeuser facilities are thlyd-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by 1CC-ES under evaluation reports ESR 1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards, i=or current code evaluation reports, Weyerhaeuser product literature and installation detalls refer to www.weyerhaeusercnm/woodproductsl document -library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Tracy Thomas T2 Consulting, LLC (206) 200-4853 thomasanntracy@gmail.com 11/7/2025 8:49:53 PM UTC ForteWEB v3.9, Engine: V8.4.3.94, Data: V8.1.7.3 Weyerhaeuser File Name: 25-113 Carbondale SFR & ADU Page 7 / 12 ;-.�iI FORTE W E B MEMBER REPORT PASSED 08125 SFR, RB GRID B 2 piece(s) 1 3/4" x 11 7/8" 2.0E Microllam@ LVL Overall Length: 9' 5" fil Q Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 4802 @ 4" 6322 (4.25") Passed (76%) -- 1.0 D + 1.0 5 (All Spans) Shear (Ibs) 3401 @ 7' 11 5/8" 9081 Passed (37%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 9981 @ 4' 8 1/2" 20525 Passed (49%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.141 @ 4' 8 1/2" 0.438 Passed (L/746) — 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.168 @ 4' 8 1/2" 0.583 Passed (LJ623) - 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Snow Factored 1 - Stud wall - SPF 5.50" 4.25" 3.23" 807 4103 4910 1 1/4" Rim Board 2 - Stud wall - SPF 5.50" 4.25" 3.01" 740 3741 4481 1 1/4" Rim Board Rim Board isassumed to carry all Ioadsappiled directly above it, bypassing the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 9' 3" o/c Bottom Edge (Lu) 9' 3" o/c -Maximum allowable bracing intervals based on applied load. Dead Snow Vertical Loads Location (Side) Tributary Width (0.90) (1.1S) Comments 0 - Self Weight (PLF) 1 1/4" to 9' 3 3/4" N/A 12.1 Linked from: R11 - 1 - Uniform (PLF) 0 to 9' (Front) N/A 159.5 871.5 Low Roof w/ drift SL, Support 1 • Side loads are assumed tO not induce cross-graln tension. Member Length : 9' 2 1/2" System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Member Pitch : 0/12 Weyerhaeuser warrants that the siring of its products will be In accordance wRh Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having Jurisdiction. The designer of record, builder at framer Is responsible to assure that this calculation is compatible with the overall prolect. Accessories (Rim Board, Blocking Panels and Squash blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports FSR-IIS3 and FSR-1387 and/or tested In accordance with applicable ASTM standards. For current code evaluation regarts. Weyerhaeuser product literature and Installation details refer to wwwmeyemaeusecWm/woddproducts/ document -library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator lob Notes Tracy Thomas T2 Consulting, LLC (206) 200-4853 thomasa nntracy@g mail.com 11/7/2025 8:49:53 PM UTC ForteWEB v3.9, Engine: V8.4.3.94, Data: V8.1.7.3 Weyerhaeuser File Name: 25-113 Carbondale SFR & ADU Page 12 / 12 ;�il FORTEW E B MEMBER REPORT PASSED 08125 SFR, Outlooker 1 piece(s) 2 x 4 DF No.2 @ 24" OC Overall Length: 4' 11" r 2' 4." r Fill o Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results I Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 648 @ 2' 5 3/4" 2231 (3.50") Passed (29%) -- 1.0 D + 1.0 S (All Spans) Shear (Ibs) 269 @ 2' 11" 725 Passed (37%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) -399 @ 2' 5 3/4" 456 Passed (88%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.195 @ 0 0.248 Passed (2L/306) -- 1.0 D + 1.0 S (Alt Spans) Total Load Defl. (in) 0.250 @ 0 0.331 Passed (2L/238) - 1.0 D + 1.0 S (Alt Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Overhang deflection criteria: LL (2L/240) and TL (2L/180). • Left cantilever length exceeds 1/3 member length or 1/2 back span length. Additional bracing should be considered. • Allowed moment does not reflect the adjustment for the beam stability factor. • A 15% increase in the moment capacity has been added to account for repetitive member usage. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Roof Live Snow Factored 1 - Stud wall - SPF 3.50" 3.50" 1.50" 150 199 498 648 Blocking 2 - Hanger on 3 1/2" SPF beam 3.50" Hangers 1.50" -2 26/-24 65/-60 1 63/-62 See note s • Blocking Panels are assumed to carry no loads applied directly above Wem and the rull load is appoen to the memaer berg designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • r See Connector grid below for additional information and/or requirements. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 4' 7" o/c Bottom Edge (Lu) 4' 7" o/c -Maximum allowable bracing intervals based on applied load. Member Length : 4' 7 1/2" System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Member Pitch : 0/12 Connector: Simpson Strong -Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger LU24 1.50" N/A 4-10dx1.5 2-lOdx1.5 • Refer to manufacturer notes and instructions for proper installation and use of all connectors. Vertical Load Location (Side) Spacing Dead (0.90) Roof Live (1.2S) Snow 1.1 comments 1 - Uniform (PSF) 0 to 4' 11" 24" 15.0 20.0 50.0 fault Load Weyerhaeuser warrants that the sizing of Its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims arty other warranties related to the software. Use of this software Is not Intended to circumvent the need for a design professional as determined by the authority having Jurisdiction. The designer of record, builder or framer is responsible to assure that this cakulation Is Compatible with the overall project. Accessories (Rim Soard, Blocking Panels and Squash 9lodcs) are not designed by this software- Products manufactured at Weyerhaeuser fablitles are third party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under evaluation reports ESR•1153 and ESR-1367 and/or tested In accordance with applicable ASTM standards. For current rode evaluation reports, Weyerhaeuser product Ilterature and Irrstaliation details refer to wvm.weyerhaeusmcom/woodprodLicW document -library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Tracy Thomas T2 Consulting, LLC (206) 200-4853 thomasanntracy@gmail.com 11/7/2025 8:49:53 PM UTC ForteWEB v3.9, Engine: V8.4.3.94, Data: V8.1.7.3 Weyerhaeuser File Name: 25-113 Carbondale SFR & ADU Page 9 / 12 ll FO RTE W E B MEMBER REPORT PASSED 08125 SFR, Outlooker Support Bm 1 piece(s) 11 7/8" TJI@ 560 Overall Length: 18' 7" 18' 0 Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) [Group] Member Reaction (Ibs) 923 @ 2" 1606 (2.25") Passed (57%) 1.15 1.0 D + 1.0 S (All Spans) [1] Shear (Ibs) 905 @ 3 1/2" 2358 Passed (38%) 1.15 1.0 D + 1.0 S (All Spans) [1] Moment (Ft-Ibs) 4184 @ 9' 3 1/2" 10925 Passed (38%) 1.15 1.0 D + 1.0 S (All Spans) [1] Live Load Defl. (in) 0.377 @ 9' 3 1/2" 0.913 Passed (L/581) — 1.0 D + 1.0 S (All Spans) [1] Total Load Defl. (in) 0.459 @ 9' 3 1/2" 1.217 1 Passed (L/477) I -- 1.0 D + 1.0 S (All Spans) [1] • Deflection criteria: LL (L/240) and TL (L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. Supports Bearing Length Loads to Supports (Ibs) Accessories Total I Available Required Dead Roof Live Snow I Factored 1 - Stud wall - SPF 3.50" 2.25" 1.75" 167 307 767 933 1 1/4" Rim Board 2 - Stud wall - SPF 3.50" 2.25" 1 1.75" 167 307 767 933 1 1/4" Rim Board • Rim Board Is assigned to carry all loads applied directly above it, bypassing the member being de<agtieo. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 8' 8" o/c Bottom Edge (Lu) 18' S" o/c •TJI joists are only analyzed using Maximum Allowable bracing solutions. -Maximum allowable bracing intervals based on applied load. Dead Roof Live Snow Vertical Loads Location Tributary (0.90) (1.25) (1.15) Comments Width 0 - Self Weight (PLF) 1 1/4" to 18' 5 3/4" N/A 4.0 1 - Uniform (PSF) 0 to 18' 7" (Front) 1' 15.0 20.0 50.0 Default Load Linked from: 2 - Uniform (PLF) 0 to 18' 7" (Front) N/A -1.0 13.0/-12.0 1 0 Outlooker, Support 2 Member Length : 18' 4 1/2" System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Member Pitch : 0/12 We eriaaeuser Notes Weyerhaeuser warrants that the suing of its products will be In accordance wb Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclalms any other warranties related to the software. Use of this software Is not Intended to arcurn ent the need fora design professional as determined by the authority having Jurisdiction. The designer or record, builder or framer is responsible to assure that this Calculation is compatible with the overall project Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to 5u5tamatAe forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICOES under evaluation reports ESR-I IS3 and ESR-1387 and/or tested In accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyertsaeusercom/wuodproducW document -library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Tracy Thomas T2 Consulting, LLC (206) 200-4853 thomasanntracy@gmail.com Weyerhaeuser 11/7/2025 8:58:45 PM UTC ForteWEB v3.9, Engine: V8.4.3.94, Data: V8.1.7.3 File Name: 25-113 Carbondale SFR & ADU Page 1 / 1 4 FORTE W E B MEMBER REPORT PASSED 08125 SFR, H5 - LL 6' kitchen 2 piece(s) 2 x 10 DF N0.2 Overall Length: 6' 3" 6' Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 2049 @ 0 2813 (1.50") Passed (73%) •- 1.0 D + 1.0 S (All Spans) Shear (Ibs) 1461 @ 10 3/4" 3830 Passed (38%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 3201 @ 3' 1 1/2" 4059 Passed (79%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.052 @ 3' 1 1/2" 0.208 Passed (L/999+) -- 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.071 @ 3' 1 1/2" 0.313 Passed (L/999+) — 1 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total I Available Required Dead Roof Live Snow Factored 1 - Trimmer - SPF 1.50" 1.50" 1.50" 542 684 1506 2049 None 2 - Trimmer - SPF 1.50" 1.50" 1.50" 542 684 1506 2049 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 63" o/c Bottom Edge (Lu) 6' 3" o/c -Maximum allowable bracing intervals based on applied load. Dead Roof Live Snow Vertical Loads Location Tributary (0.90) (1.25) (1.15) Comments Width 0 - Self Weight (PLF) 0 to 6' 3" N/A 7.0 — Linked from: R11 - 1 - Uniform (PLF) 0 to 6' 3" N/A 166.5 219.0 482.0 Low Roof, Support 2 Member Length : 6' 3" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software- Use of this software Is not Intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or flamer Is responsible to assure that this mkulatlon Is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Socks) are not designed by this software. Products manubctured at Weyerhaeuser facilities are thlyd-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC•ES under evaluation reports E5R 1153 and ESP, 1367 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and InstalWtIon details refer to www.we"rnaeLwcom/woodprQductY document -library. product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Tracy Thomas T2 Consulting, LLC (206) 200-4853 thomasanntracy@gmail.com 9/23/2025 3:51:34 PM UTC ForteWEB v3.9, Engine: V8.4.3.94, Data: V8.1.7.3 Weyerhaeuser File Name: 25-113 Carbondale SFR & ADU Page 11 / 31 2FORTEWEB MEMBER REPORT 08125 SFR, H6 - LL 3' kitchen 2 piece(s) 2 x 6 DF No.2 PASSED + 0 0 Overall Length: 3' 3" A 2 Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1061 @ 0 2813 (1.50") Passed (38%) — 1.0 D + 1.0 S (All Spans) Shear (Ibs) 680 @ 7" 2277 Passed (30%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 862 @ V 7 1/2" 1696 Passed (51%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.018 @ V 7 1/2" 0.108 Passed (L/999+) -- 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.025 @ 1' 7 1/2" 0.162 Passed (L/999+) -- 1.0 D + 1.0 S (All Spans) • Deflection criteria: ILL (L/36U) and I L (L/24U). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Roof Live Snow Factored 1 - Trimmer - SPF 1.50" 1.50" 1.50' 277 356 783 1061 None 2 - Trimmer - SPF 1.50" 1.50" 1.50" 277 356 783 1061 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 3' 3" o/c Bottom Edge (Lu) 3' 3" o/c -Maximum allowable bracing intervals based on applied load. Dead Roof Live Snow Vertical Loads Location Tributary (0.90) (1.25) (1.15) Comments Width 0 - Self Weight (PLF) 0 to 3' 3" N/A 4.2 — - - Linked from: R11 - 1 - Uniform (PLF) 0 to 3' 3" N/A 166.5 219.0 482.0 Low Roof, Support 2 0 Member Length : 3' 3" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD W rhaeuser Notes Weyerhaeuser warrants that the siring of Its products wlii be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disdaims any other warranties related to the software. use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdicZan. The designer of record, builder or framer is responsible to assure that this calculation Is compatible with the overall project. Accessories (Rim Hoar(, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICOES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evalualltxl reports, Weyerhaeuser product literatureand in5tellatlpn details refer to www.weyerhaetrer.corruwoodproduct5/ document -library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Tracy Thomas T2 Consulting, LLC (206) 200-4853 thomasanntracy@gmail.com Weyerhaeuser 9/23/2025 3:51:34 PM UTC ForteWEB v3.9, Engine: V8.4.3.94, Data: V8.1.7.3 File Name: 25-113 Carbondale SFR & ADU Page 12 / 31 :IFORTEWER + 0 a MEMBER REPORT 08125 SFR, H7 - Grid 3 Slider 2 piece(s) 1 3/4" x 7 1/4" 2.0E Microllam® LVL Overall Length: 11' 11" Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed 1 Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 700 @ 0 3806 (1.50") Passed (18%) -- 1.0 D + 1.0 L (All Spans) Shear (Ibs) 614 @ 8 3/4" 4821 Passed (13%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 2084 @ 5' 11 1/2" 7115 Passed (29%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.170 @ 5' 11 1/2" 0.397 Passed (L/842) 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 0.249 @ T 11 1/2" 0.313 Passed (L/574) 1.0 D + 1.0 L (All Spans) • Deflection criteria: LL (L/360) and TL (5/16"). • Allowed moment does not reflect the adjustment for the beam stability factor. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live I Factored 1 - Trimmer - SPF 1.50" 1.50" 1.50" 223 477 700 None 2 - Trimmer - SPF 1.50" 1.50" 1.50" 223 477 700 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 11' 11" o/c Bottom Edge (Lu) 11' 11" o/c -Maximum allowable bracing intervals based on applied load. Dead Floor Live Vertical Loads Location Tributary (0.90) (1.00) Comments Width 0 - Self Weight (PLF) 0 to 11' 11" N/A 7.4 1 - Uniform (PSF) 0 to 11' 11" 2' 15.0 40.0 Default Load PASSED 0 Member Length : 11' 11" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction, The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser Facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document -library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Tracy Thomas T2 Consulting, LLC (206) 200-4853 thomasanntracy@gmail.com 9/23/2025 3:51:34 PM UTC ForteWEB v3.9, Engine: V8.4.3.94, Data: V8.1.7.3 Weyerhaeuser File Name: 25-113 Carbondale SFR & ADU Page 16 / 31 i�iFORTE W E B MEMBER REPORT 08125 SFR, F11 - Grid 8 - D 1 piece(s) 11 7/8" T3I@ 560 @ 16" OC PASSED Overall Length: 22' 0 0 22 0 ❑2 Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 776 @ 5 1/2" 1265 (1.75") Passed (61%) 1.00 1.0 D + 1.0 L (All Spans) Shear (Ibs) 776 @ 5 1/2" 2050 Passed (38%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 4107 @ 11' 1/2" 9500 Passed (43%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl.(in) 0.380 @ 11' 1/2" 0.529 Passed (L/669) -- 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 0.522 @ 11' 1/2" 1.058 Passed (L/486) 1-- 1.0 D + 1.0 L (All Spans) T3-Pro"" Rating 44 40 Passed I- • Deflection criteria: LL (L/480) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • A structural analysis of the deck has not been performed. • Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser EdgeT" Panel (24" Span Rating) that is glued and nailed down. • Additional considerations for the TJ-ProT" Rating include: 5/8" Gypsum ceiling. Member Length : 21' 5 1/4" System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Supports Bearing Length Loads to Supports (Ibs) Accessories Details Total Available Required Dead Floor Live Factored 1 - Hanger on 11 7/8" DF beam 5.50" Hanger' 1.75" / - z 221 589 810 See note' 2 - Beam - DF 5.50" 4.25" 1.75" 219 584 804 1 1/4" Rim Board A3 • Rim Board is assumed to carry all bads applied directly, above it, bypassing the memoer oeing aesignea. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ' See Connector grid below for additional information and/or requirements. • z Required Bearing Length / Required Bearing Length with Web Stiffeners Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 8' 9" o/c Bottom Edge (Lu) 21' 5" o/c •TJI joists are only analyzed using Maximum Allowable bracing solutions. -Maximum allowable bracing intervals based on applied load. Connector: Simpson Strong -Tie Support Model Seat Length Top Fasteners Face Fasteners I Member Fasteners 1,Accessories 1 - Face Mount Hanger IIUS3.56/11.88 2.00" N/A 12-10dx1.5 2-Strong-Grip • Refer to manufacturer notes and instructions for proper installation and use of all connectors. Vertical Load Location Spacing Dead (0.90) Floor Live (1.00) Comments 1 - Uniform (PSF) 0 to 22' 16" 15.0 40.0 Default Load Weyerhaeuser Notes Weyerhaeuser warrants that the siring of Its products wlll be In accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a desigri professional as determined by the auttiority having jurisdiction. The designer of retard, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Sloeking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser fatilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under eyaluation reports MR 1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards, For current code evaluation reports, Weyerhaeuser product literature and InaMlatlon details refer to www.weyerhaererwmjwoWpmducW document -library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator lob Notes 9/23/2025 3:51:34 PM UTC Tracy Thomas T2 Consulting, LLC ForteWEB v3.9, Engine: V8.4.3.94, Data: V8.1.7.3 (206) 200-4853 File Name: 25-113 Carbondale SFR & ADU thomasanntracy@gmail.com Weyerhaeuser Page 6/31 a FO RTE W E B MEMBER REPORT PASSED 08125 SFR, H8 - Grid 8 doorway 2 piece(s) 2 x 6 DF No.2 Overall Length: 3' 3" 3' 11 Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 985 @ 0 2813 (1.50") Passed (35%) -- 1.0 D + 1.0 L (All Spans) Shear (Ibs) 632 @ 7" 1980 Passed (321/o) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 801 @ 1' 7 1/2" 1475 Passed (54%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.017 @ 1' 7 1/2" 0.108 Passed (L/999+) -- 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 0.023 @ 1' 7 1/2" 0.162 Passed (L/999+) — 1 1.0 D + 1.0 L (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total I Available Required Dead Floor Live Factored 1 - Trimmer - SPF 1.S0" 1.50" 1.50" 274 712 985 None 2 - Trimmer - SPF 1.50"' 1.50" 1.50" 274 712 985 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 3' 3" o/c Bottom Edge (Lu) 3' 3" o/c -Maximum allowable bracing intervals based on applied load. Dead Floor Live Vertical Loads Location Tributary (0.90) (1.00) Comments Width 0 - Self Weight (PLF) 0 to 3' 3" N/A 4.2 -- 1 - Uniform (PLF) 0 to 3' 3" N/A 164.3 438.0 Linked from: Floor: Joist, Support 2 Member Length : 3' 3" System : Wall Member Type: Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser productdes[gn criteria and published design values. Weyerhaeuser expressdy disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessorles (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilltles are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable A57M standards. For current code evaluation reports,. Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document -library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Tracy Thomas T2 Consulting, LLC (206) 200-4653 thomasanntracy@gmall.com 9/23/2025 3:51:34 PM LTC ForteWEB v3.9, Engine: V8.4.3.94, Data: V8.1.7.3 Weyerhaeuser File Name: 25-113 Carbondale SFR & ADU Page 17 / 31 I FORTEWER MEMBER REPORT PASSED 08125 SFR, H9 - Grid 4 window 2 piece(s) 2 x 6 DF No.2 0 Overall Length: T 3" 3' 0 Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1366 @ 0 2813 (1.50") Passed (49%) 1.0 D + 0.75 L + 0.75 S (All Spans) Shear (Ibs) 876 @ 7" 2277 Passed (38%) 1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Moment (Ft-Ibs) 1110 @ 1' 7 1/2" 1696 Passed (65%) 1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in) 0,021 @ 1' 7 1/2" 0.108 Passed (L/999+) — 1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in) 0.032 @ 1' 7 1/2" 0.162 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. 0 Member Length : 3' 3" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Roof Live Snow Factored 1 - Trimmer - SPF 1.50" 1.50" 1.50" 447 585 291 640 1366 None 2 - Trimmer - SPF 1.50" 1.50" 1.50" 447 585 291 1 640 1366 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 3' 3" o/c Bottom Edge (Lu) 3' 3" o/c -Maximum allowable bracing intervals based on applied load. Dead Floor Live Roof Live Snow Vertical Loads Location Tributary (0.90) (1,00) (1.25) (1.15) Comments Width 0 - Self Weight (PLF) 0 to 3' 3" N/A 4.2 Linked from: 92 - 1 - Uniform (PLF) 0 to 3' 3" N/A 135.0 360.0 — — Grid 2 - 4, Support 1 Linked from: RJ2 - 2 - Uniform (PLF) 0 to 3' 3" N/A 136.0 ^- 179.0 394.0 Upper Roof, Support 1 Weyerhaeuser warrants that the sizing of Its products will be in bpo**fICE with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended todrtt7 m"t the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at NfeoeMeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser EngirmWed Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 aridlor tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhmeuser product literature arrd installation di Wls refer to W rw.weyerhaeu�ercom/woodproducts/ document -library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Tracy Thomas T2 Consulting, LLC (206) 200-4853 thomasanntracy@gmail.com 9/23/2025 3:51:34 PM UTC ForteWEB v3.9, Engine: V8.4.3.94, Data: V8.1.7.3 Weyerhaeuser File Name: 25-113 Carbondale SFR & ADU Page 18 / 31 l FO RTE W E B MEMBER REPORT PASSED 08125 SFR, F12 - Grid 2 - 4 1 piece(s) 11 7/8" TJI® 360 @ 16" OC Overall Length: 18' 18, u Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 660 @ 4 1/2" 1505 (3.50") Passed (44%) 1.00 1.0 D + 1.0 L (All Spans) Shear Ibs) 626 @ 5 1/2" 1705 Passed (37%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 2728 @ 9' 6180 Passed (44%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl.(in) 0.250 @ 9' 0.431 Passed (L/830) -- 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 0.343 @ 9' 0.863 Passed (L/603) 1.0 D + 1.0 L (All Spans) TJ-ProTM Rating 44 40 Passed - • Deflection criteria: LL (L/480) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • A structural analysis of the deck has not been performed. • Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser Edge"' Panel (24" Span Rating) that is glued and nailed down. • Additional considerations for the TJ-Pro" Rating include: None. Member Length : 17' 10 3/4" System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Supports Bearing Length Loads to Supports (Ibs) Accessories Details Total Available Required Dead Floor Live Factored 1 - Beam - DF 5.50" 5.50" 1.75" 180 480 660 Blocking Al 2 - Beam - DF 5.50" 4.25" 1.75" 180 480 660 1 1/4" Rim Board A3 • Rfm Board is assumed to carry all loads applied directly above it, bypassing the member tieing designed. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 5' 8" o/c Bottom Edge (Lu) 17' 11" o/c •TJI joists are only analyzed using Maximum Allowable bracing solutions. -Maximum allowable bracing intervals based on applied load. Vertical Load Location Spacing Dead (0.90) Floor Live (1.00) Comments 1 - Uniform (PSF) 0 to 18' 16" 15.0 40.0 Default Load Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims arty other warranties related to the software. Use of this software Is not Intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of retard, builder or frarner is responsible to assure that this calculation is compatible with the overall Project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Produm have been evaluated by [CC -ES under evaluation reports ESR-1153 and M-1387 and(or tested In accordance with applicable ASTM standards. For current code evdlua[iDn reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document -library. product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Tracy Thomas T2 Consulting, LLC (206) 200-4853 thomasanntracy@gmail.com 9/23/2025 3:51:34 PM UTC ForteWEB v3.9, Engine: V8.4.3.94, Data: V8.1.7.3 Weyerhaeuser File Name: 25-113 Carbondale SFR & ADU Page 19 / 31 4FORTEWER MEMBER REPORT PASSED 08125 SFR, FJ3 - LL Joists 1 piece(s) 11 7/8" TJI@ 560 @ 16" OC 0 Overall Length: 35' 4 1./2" 1 13' a n 21' Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 651 @ 34' 11" 1265 (1.75") Passed (51%) 1.00 1.0 D + 1.0 L (Alt Spans) Shear (Ibs) 878 @ 13' 11" 2255 Passed (39%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) -3161 @ 13' 8 1/4" 9500 Passed (33%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.261 @ 25' 7/8" 0.531 Passed (L/978) -- 1.0 D + 1.0 L (Alt Spans) Total Load Defl. (in) 0.347 @ 25' 1 3/4" 1.061 1 Passed (L/734) - 1.0 D + 1.0 L (Alt Spans) TJ-Pro"" Rating 41 40 1 Passed - • Deflection criteria: LL (L/480) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • A structural analysis of the deck has not been performed. • Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser Edge" Panel (24" Span Rating) that is glued and nailed down. • Additional considerations for the TJ-Pro'"' Rating include: None. + 0 Member Length : 34' 5 1/2" System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Supports Bearing Length Loads to Supports (Ibs) Accessories Details Total Available Required Dead Floor Live Factored 1 - Hanger on 11 7/8" DF beam 5.50" Hanger' 1.75" / - 1 76 343/-115 420/-39 See note W 2 - Stud wall - DF 5.50" 5.50" 3.50" 450 1201 1651 None 3 - Hanger on 11 7/8" DF beam 5.50" Hanger' 1.75" / - z 181 503 684 See note 1 • At hanger supports, me iorai nearing ulmenslun Ls equao ru Lrre wiuui ui we awtur ni mink o s pjl ,furry k.rc rr­ycr • ' See Connector grid below for additional information and/or requirements. • z Required Bearing Length / Required Bearing Length with Web Stiffeners Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 10' 6" o/c Bottom Edge (Lu) 10' o/c •TJI joists are only analyzed using Maximum Allowable nracing solutions. -Maximum allowable bracing intervals based on applied load. Connector: Simpson Strong -Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 1 - Face Mount Hanger IUS3.56/9.5 2.00" N/A 10-10dx1.5 2-10dx1.5 Web Stiffeners 3 - Top Mount Hanger ITS3.56/11.88 2.00" 4-SOdx1.5 2-10dx1.5 2-Strong-Grip • Refer to manufacturer notes and instructions for proper installation ano use or ail connectors. Vertical Load Location Spacing Dead (0.90) Floor Live (1.00) Comments 1 - Uniform (PSF) 0 to 35' 4 1/2" 16" 15.0 40.0 Default Load ForteWEB Software Operator Job Notes Tracy Thomas T2 Consulting, LLC (206) 200-4853 thomasanntracy@gmaii.com 9/23/2025 3:51:34 PM UTC ForteWEB v3.9, Engine: V8.4.3.94, Data: V8.1.7.3 Weyerhaeuser File Name: 25-113 Carbondale SFR & ADU Page 22 / 31 .I FORTE W E B MEMBER REPORT PASSED 08125 SFR, FB5 - Grid 3 LL 1 piece(s) 5 1/8" x 12" 24F-V4 DF Glulam Overall Length: 20' 6 1/2" 9' 6" 1❑ n 0 Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) [Group] Member Reaction (Ibs) 1738 @ 20' 1" 4997 (1.50") Passed (35%) 1.0 D + 1.0 L (Alt Spans) [1] Shear (Ibs) 2105 @ 11' 5" 10865 Passed (19%) 1.00 1.0 D + 1.0 L (All Spans) [1] Pos Moment (Ft-Ibs) 3550 @ 15' 11 15/16" 24600 Passed (14%) 1.00 1.0 D + 1.0 L (Alt Spans) [1] Neg Moment (Ft-Ibs) -5183 @ 10' 2 1/4" 18963 Passed (27%) 1.00 1.0 D + 1.0 L (All Spans) [1] Live Load Defl. (in) 0.029 @ 15' 4 15/16" 1 0.247 Passed (L/999+) -- 1.0 D + 1.0 L (Alt Spans) [1] Total Load Defl. (in) 0.041 @ 15' 6 3/4" 1 0.495 1 Passed (L/999+) 1.0 D + 1.0 L (Alt Spans) [1] • Deflection criteria: LL (L/480) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Volume factor of 1.00 was calculated for positive bending using length L = 8' 2 1/16". • Volume factor of 1.00 was calculated for negative bending using length L = 4' 11 1/4". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total I Available Required Dead I Floor Live Factored 1 - Column - SPF 5.50" 4.25" 1.50" 674 1195/-401 1869 1 1/4" Rim Board 2 - Column - SPF 5.50" 5.50" 1.58" 2073 3175/-1065 5249 None 3 - Hanger on 12" DF Ledger 5.50" Hangerr 1.50" 692 1221/-409 1912 See note ' • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • � See Connector grid below for additional information and/or requirements. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 20' o/c Bottom Edge (Lu) 20' o/c •Maximum allowable bracing intervals based on applied load. Member Length : 19' 11 3/4" System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Connector: Simpson Strong -Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 3 - Face Mount Hanger Connector not found N/A N/A N/A N/A • Refer to manufacturer notes and instructions for proper installation and use of all connectors. Dead Floor Live Vertical Loads Location (Side) Tributary Width (0.90) (1.00) Comments 0 - Self Weight (PLF) 1 1/4" to 20' 1" N/A 14.9 — 1 - Uniform (PSF) 0 to 20' 6 1/2" (Front) 9 12.0 — WALL LOAD Linked from: F33 - 2 - Uniform (PLF) 0 to 20' 6" (Front) N/A 57.0 257.3/-86.3 LL Joists, Support 1 - Side loads are assumed to not induce cross -grain tension. ForteWEB Software Operator Job Notes Tracy Thomas T2 Consulting, LLC (206) 200-4853 thomasanntracy@gmail.com 9/23/2025 3:51:34 PM UTC ForteWEB v3.9, Engine: V8.4.3.94, Data: V8.1.7.3 Weyerhaeuser File Name: 25-113 Carbondale SFR & ADU Page 24 / 31 2 FORTE W E R MEMBER REPORT 08125 SFR, F14 - Deck Joist 1 piece(s) 2 x 8 DF No.2 @ 16" OC PASSED Overall Length: 9' 10 14" 1 + + 0 0 L__ 9' V. 0 Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 311 @ 5 1/2" 1406 (1.50") Passed (22%) 1.0 D + 1.0 L (All Spans) Shear (Ibs) 269 @ 1' 3/4" 1305 Passed (21%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 699 @ 4' 11 3/8" 1360 Passed (51%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.102 @ 4' 11 3/8" 0.224 Passed (L/999+) - 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 0.133 @ 4' 11 3/8" 0.449 1 Passed (L/810) - 1.0 D + 1.0 L (All Spans) T3-Pro"" Rating N/A N/A I N/A I — N/A • Deflection criteria: LL (L/480) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • A 15% increase in the moment capacity has been added to account for repetitive member usage. • Applicable calculations are based on NDS. • No composite action between deck and joist was considered in analysis. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Factored 1 - Hanger on 7 1/4" DF beam 5.50" Hanger- 1.50" 79 264 343 See note 2 - Hanger on 7 1/4" DF beam 5.50" Hanger' 1.50" 79 264 343 See note - • At hanger sVpporM the Total Bearing dimension is equal to the width OF the material that 4s supporting the nanger • - See Connector grid below for additional information and/or requirements. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 9' o/c Bottom Edge (Lu) 9' o/c -Maximum allowable bracing intervals based on applied load. Member Length : 8' 11 3/4" System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Connector: Simpson Strong -Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 1 - Face Mount Hanger LU26 1.50" N/A 6-lOdx1.5 4-10dxl.5 2 - Face Mount Hanger LU26 1.50" N/A 6-lOdx1.5 4-10dxl.5 • Refer to manufacturer notes and instructions for proper installation and use of all connectors. Vertical Load Location (Side) Spacing Dead (0.90) Floor Live (1.00) Comments 1 - Uniform (PSF) 0 to 9' 10 3/4" 16" 12.0 40.0 Default Load Weyerhaeuser warrants that the sizing of Its products will be In accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software Is not Intended to circumvent the need for a design professional as determined by the authority having Jurisdiction. The designer of retard, builder or framer Is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Pands and Squash Blacks) are not designed bN this software. Products manufactured at Weyerhaeuser f iblities are third -party certlfled to sustainable forestry standards. Weyerhaeuser Englneered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR•1153 and ESR-1387 and/or tested In accordance with applicable A5n4 standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document -library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Tracy Thomas T2 Consulting, LLC (206) 200-4853 thomasanntracy@gmaii.com 9/23/2025 3:51:34 PM UTC ForteWEB 0.9, Engine: V8.4.3.94, Data: V8.1.7.3 Weyerhaeuser File Name: 25-113 Carbondale SFR & ADU Page 26 / 31 a FORTEWEB MEMBER REPORT 08125 SFR, F66 - Grid B+ 1 piece(s) 3 1/8" x 7 1/2" 24F-V4 DF Glulam PASSED 0 Overall Length: 8' 7" 8' 2 Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 2061 @ 2" 2988 (2.25") Passed (69%) -- 1.0 D + 1.0 L (All Spans) Shear (Ibs) 1718 @ 78" 4141 Passed (41%) 1.00 1.0 D + 1.0 L (All Spans) Pos Moment (Ft-Ibs) 4123 @ 4' 2 3/4" 5859 Passed (70%) 1.00 1.0 D + 1.0 L (All Spans) Live Load DeFl. (in) 0.188 @ 4' 2 3/4" 0.203 Passed (L/517) - 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 0.248 @ 4' 2 3/4" 1 0.406 1 Passed (L/394) -- 1.0 D + 1.0 L (All Spans) • Deflection criteria: LL (L/480) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Volume factor of 1.00 was calculated for positive bending using length L = 8' 1 1/2". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Factored 1 - Stud wall - SPF 3.50" 2.25" 1.55" 506 1607 2113 1 1/4" Rim Board 2 - Hanger on 7 1/2" SPF beam 3.50" Hanger 1.50" 520 1655 2174 See note r • KIM UoarQ IS assumes to carrya9 I0005apPMU Uireury duuve a, uypdnsi ny L­ II r I , ueury uoyueu- • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ' See Connector grid below for additional information and/or requirements. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 8' 2" o/c Bottom Edge (Lu) 8' 2" o/c -Maximum allowable bracing intervals based on applied load. 0 Member Length : 8' 2 1/4" System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Connector: Simpson Strong -Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger HHUS28-2 3.00" N/A 22-10d 4-10d • Rerer to manutacturer notes ano mstrucnons Tor proper InstallanOn anu use ui au c.unneuurs. Dead Floor Live Vertical Loads Location (Side) Tributary Width (0.90) (1.00) Comments 0 - Self Weight (PLF) 1 1/4" to 8' 3 1/2" N/A 5.7 1 - Uniform (PSF) 0 to 8' 7" (Top) H' 6" 12.0 40.0 Default Load • Sloe ;oao5 are a5sumea to nut m¢uce cross-yrdui renswn. ForteWEB Software Operator Job Notes Tracy Thomas T2 Consulting, LLC (206)200-4853 thomasanntracy@gmail.com 9/23/2025 3:51:34 PM UTC ForteWEB v3.9, Engine: V8.4.3.94, Data: V8.1.7.3 Weyerhaeuser File Name: 25-113 Carbondale SFR & ADU Page 27 / 31 .i FO R TE W E B MEMBER REPORT PASSED 08125 SFR, DECK FLUSH BEAM 2 piece(s) 2 x 8 DF No.2 Overall Length: 8' 11" + + 0 - 0 I �- 0 Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1079 @ 8' 5 1/2" 2813 (1.50") Passed (38%) -- 1.0 D + 1.0 L (All Spans) Shear (Ibs) 918 @ 7' 10 1/4" 2610 Passed (35%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 2191 @ 4' 4 3/4" 2365 Passed (93%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.129 @ 4' 4 3/4" 0.203 Passed (L/758) - 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 0.171 @ 4' 4 3/4" 0.406 Passed (L/571) -- 1.0 D + 1.0 L (All Spans) • Deflection criteria: LL (L/480) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Factored 1 - Column - DF 5.50" 4.25" 1.50" 287 879 1167 1 1/4" Rim Board 2 - Hanger on DF studWall 5.50" Hangerr 1.50" 294 904 1198 See note ' • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • r See Connector grid below for additional information and/or requirements. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 8' 4" o/c Bottom Edge (Lu) 8' 4" o/c -Maximum allowable bracing intervals based on applied load, Member Length : 8' 4 1/4" System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Connector: Simpson Strong -Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Top Mount Hanger BA28-2 3.00" 6-10d 8-10d 2-10dxl.5 • Refer to manufacturer notes and instructions for proper installation and use of all connectors. Dead Floor Live Vertical Loads Location (Side) Tributary Width (0.90) (1.00) Comments 0 - Self Weight (PLF) 1 1/4" to 8' 5 1/2" N/A 5.5 •- 1 - Uniform (PSF) 0 to 8' 11" (Front) 5' 12.0 40.0 Default Load • Side loads are assumed to not induce cross -grain tension. Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having )udsdiction. The designer of record, buitder or framer is responsible to assure that this cakulation Is Compatible with the Overall project. Accessories (Rim Board, Blocking Panels arid Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and FSR-1387 and/or tested In accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and Installation details refer to www.weyerhaeusercom/woodproductsl document -library. product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Tracy Thomas T2 Consulting, LLC (206) 200-4853 thomasanntracy@gmail.com 9/23/2025 3:51:34 PM UTC ForteWEB v3.9, Engine: V8.4.3.94, Data: V8.1.7.3 Weyerhaeuser File Name: 25-113 Carbondale SFR & ADU Page 29 / 31 Holding Ground Architects Ilc PO Box 273 Bozeman, MT 59715 406.570.2683 HOLDING GROUND A R C H I T E C T S MEMO TO: Colleen Wirth (Plans Examiner, Garfield County Community Development) FROM: Tripp Lewton CC: Rebecca Hengemuhle; Thaddeus Eshelman DATE: 11 /7/2025 SUBJECT: BLRE-10-25-9518 Hengemuhle - PERMITAEUlEWCCRRECT10NS1 FSPONSE Hi Colleen, Please see our responses (below) to the corrections and clarifications you have requested in your 11/3/2025 email to me, concerning the BLRE-10-25-9518HengemuhieSFDpermit application. For the sake of clarity, I am copy -pasting the full contents of your email, with our responses inserted, italicized in GREEN. CORRECTIONS: 1. The'/2 page MANUAL J BLOCK LOAD REPORT has no identifying information from what program the report is generated or who authored the load report (i.e. Wrightsoft or other?). Block Load report-- while a brief summary -- offers minimal depth of detail. Report further references 7,000 ft ASL, while A0.2 dated 9/24/2025 indicates a modestly higher site elevation at 7097.5 ft ASL. REQUESTED ACTION: Resubmit complete Manual J Report for 7332 CR 100 House. Other mechanical colleagues generating reports for similar work scopes, are sharing a printed copy of a Manual J report of typically 10-15 pages (and upwards to 30-40 pages) in length along with actual site location elevation data referenced. I trust there is a more detailed report copy available. I'd like to read the full report and staple copy to the issued FIELD PLANS. Thank you. HGA RESPONSE.- Please see the attached full length complete Manual'I Report for 7332 CR 100 House. File name: `251107 7332CR 100 - 004 MANUAL J REPORT -REVISION 1. pdf" Page 1 (of 3) Holding Ground Architects Ilc PO Box 273 Bozeman, MT 59715 406.570.2683 MEMO HOLDING GROUND A R C H I T E C T S TO: Colleen Wirth (Plans Examiner, Garfield County Community Development) FROM: Tripp Lewton CC: Rebecca Hengemuhle; Thaddeus Eshelman DATE: 11 /7/2025 SUBJECT: BLRE-10-25-9518 Hengemuhle - PERMIT -REVIEW CORRECTIONS RESPONSE 2. T2 Structural job 23-165 Structural Calculations and Tripp's (Holding Ground Architects) stamped sheet S0.1 are showing different proposed Ground and Roof Snowload values. The Building permit application form we received is leaving blanks for contact information on Engineer of Record. The S sheets are stamped by Tripp, Architect of Record. Unclear who is T2 Structural on the structural calculations? For engineer's awareness, sheet A1.3 is showing installation of snow guards to retain snow on the metal roof. A0.2 site plan is showing proposed house at 7,097.5 ft elevation. With competing information, it is unclear if the designed Pf = roof snowload will be adequate for this location at 7,097.5 ft elevation. Below is screen view of Garfield County's local amendment for snowload: REQUESTED ACTION STEP: PROVIDE A STATEMENT AFFIRMING WHO SHALL SERVE AS THE STRUCTURAL ENGINEER OF RECORD. SUPPLY THE INDIVIDUAL'S CONTACT NAME AND PHONE / EMAIL INFORMATION. PLEASE HAVE YOUR ENGINEER OF RECORD SUPPLY A WET STAMPED LETTER CLARIFYING THE DESIGN ROOF SNOWLOAD (Pf = measured at roof, not ground) for the Rebecca Hengemuhle residence located at 7332 CR 100, outside Carbondale. Wherever T2 Structural's Structural Calculations and/or Structural Sheet(s) need to updated or altered, then do prepare (2) full size paper copies of any REVISED SHEETS, clearly dated and clouded with REVISIONS along with a paper copy of an UPDATED MANUAL J REPORT to the Garfield County Community Development Department front desk, located in downtown Glenwood Springs, Colorado. HGA RESPONSE.- This project does not have, nor require, an Engineer of Record. Holding Ground Architects is the Architect of Record under Tripp's Page 2 (of 3) Holding Ground Architects Ilc PO Box 273 Bozeman, MT 59715 406.570,2683 HOLDING GROUND A R C H I T E C T S MEMO TO: Colleen Wirth (Plans Examiner, Garfield County Community Development) FROM: Tripp Lewton CC: Rebecca Hengemuhle; Thaddeus Eshelman DATE: 11 /7/2025 SUBJECT: BLRE-10-25-9518 Hengemuhle — PERMITREVIEWCOR4'ECTIONSRESPONSE License to practice in the State of Colorado. (T2 Structural is a professional engineering entity performing structural design services as a subcontractor to Holding Ground Architects.) As such, all structural questions, comments and clarifications should be directed to Holding Ground Architects. The design roof snowload discrepancy, discussed above, has been corrected in the structural drawings and calculations. Revised documents are attached, and as follows.: '251107 7332CR 100 DRA WINGS - SO 1 REVISION 1. pdf" '251107 7332CR IOO - 006 STRUCTURAL CALCULA TIONS - REVISION 1. pdf" Revisions to these documents are as follows: DRAWINGS, SO 1 General Notes -See 'Structural General Notes'section STRUCTURAL CALCS: Revised pages: page 17-page 21 New pages: page 3 All revised documents listed above will be submitted in hard copy (2 full-size copies of each) to Garfield County Community Development as soon as we are able. Please feel free to contact me with any additional questions or concerns. Many thanks, Colleen! Kind regards, Tripp Lewton Attachments: 251107 7332CR100 - 004 MANUAL J REPORT -REVISION 1.pdf 251107 7332CR100 DRAWINGS - SO-1 REVISION 1.pdf 251107 7332CR100 - 006 STRUCTURAL CALCULATIONS — REVISION 1.pdf Page 3 (of 3)