HomeMy WebLinkAboutBlower Door TestResidential Air Infiltration Test Report
Test date:12/5/2025
Project name:287 Hunt Ranch Road
Address:287 Hunt Ranch Road, Carbondale
Garfield
Code:2018 IECC
Conditioned volume:71,201 Cubic Feet
Attic:non-vented
Crawlspace:0
Garage:excluded
Measured airflow:2,272 CFM50 Cubic Feet per Minute at 50 Pascal
Temperature; Inside:65
Temperature; Outside:35
Elevation:7,076
Corrected airflow:2,237 CFM50*Cubic Feet per Minute at 50 Pascal
2018 IECC maximum allowed leakage rate:3.0 ACH50 Air Changes Per Hour at 50 Pascal
Tested air leakage rate:1.9 ACH50 Air Changes Per Hour at 50 Pascal
Test code compliance:PASS
Test notes:
Tests were performed by Chris Taylor; Rated Field Inspector, RFIIN #CY5MPL
* Test results have been corrected for elevation and air density temperature differential.
final blower door test.