Loading...
HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT BLRE-06-25-9289 SPERRY FAMILY TRUST New Single-family dwelling 5811 CR 320, Rifle Sec 27, Twns 06, R94 - 217527100128 1) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.) AND 2018 INTERNATIONAL ENERGY CONSERVATION CODE (I.E.C.C.) 2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED "GARFIELD COUNTY BUILDING REQUIREMENTS". NUMBER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRICAL PERMITTING AND INSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH -IN APPROVAL IS REQUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REQUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY. 4) ALL EXTERIOR LIGHTING TO BE DOWNCAST AND SHIELDED. 5) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. PLEASE REFER TO THE GARFIELD COUNTY COMMUNITY DEVELOPMENT WEBSITE FOR ADDITIONAL INFORMATION. 6) OPEN HOLE SOILS REPORT IS REQUIRED AT FOOTING INSPECTION AND PRIOR TO ANY CONCRETE POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR. 2,000 PSF soil bearing. 7) LOG STRUCTURES - ALL STRUCTURAL LOGS SHALL BE DESIGNED BY A COLORADO LICENSED ARCHITECT OR ENGINEER, AND THE ARCHITECT OR ENGINEER SHALL INSPECT LOGS AFTER COMPLETION OF FRAMING TO CERTIFY THE SIZE, QUALITY AND SPECIES OF LOGS COMPLY WITH ORIGINAL DESIGN REQUIREMENTS. PROVIDE COPY OF REPORT FOR INSPECTOR REVIEW AT FRAME INSPECTION. 8) SEPTIC SYSTEM REVIEW / APPROVALS: PRIOR TO BUILDING INSPECTION & CERTIFICATE OF OCCUPANCY PROVIDE FINAL APPROVAL/SIGN-OFF FROM GARFIELD COUNTY'S PUBLIC HEALTH DEPT. 9) A LOT IMPROVEMENT CERTIFICATE, SEALED BY A COLORADO LICENSED SURVEYOR, IS REQUIRED AT FOUNDATION INSPECTION TO VERIFY STRUCTURE IS IN COMPLIANCE WITH MINIMUM SETBACK REQUIREMENTS / BUILDING ENVELOPE. 10) BLOWER DOOR TEST IS REQUIRED. MUST SUBMIT BLOWER DOOR TEST REPORT TO GARFIELD COUNTY COMMUNITY DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING INSPECTION / C.O. FINAL. 11) PRESCRIPTIVE PATH USING ATTACHED RESCHECK REPORT HAS BEEN CHOSEN FOR ENERGY COMPLIANCE OF THIS HOME DESIGN. MANUAL J REPORT ALSO ATTACHED FOR REFERENCE. ALL NEW HOMES TO HAVE WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM INSTALLED (2015 IRC TABLE ml507.3.3(1) AND (2) SHOWN ON COVER SHEET. INSTALL STORMWATER CONTROLS PRIOR TO ANY DIRT WORK. LOCATE ALL UTILITIES PRIOR TO ANY WORK. 811 IS THE STATE UTILITY LOCATE NUMBER CONTROL NOXIOUS WEEDS. TREAT EXISTING WEEDS PRIOR TO RELOCATING PLANTS AND SEEDS. REVEGITATE ALL DISTURBED AREAS THAT ARE NOT PART OF A ROAD OR NON -SEEDED AREA. PROVIDE EROSION CONTROLS UNTIL SEEDED AREAS CAN BE ESTABLISHED. PROVIDE DUST CONTROL AS REQUIRED DURING CONSTRUCTION. MAINTAIN ALL DRAINAGE ON THE SUBJECT PROPERTY, DRAINAGE SHALL NOT ENTER NEIGHBORING PROPERTIES OTHER THAN HISTORIC DRAINAGE. FOLLOW ENGINEERED PLANS. VERIFY ANY CHANGES WITH THE ENGINEER.