HomeMy WebLinkAboutRescheck ReportGenerated by REScheck-Web Software Compliance certificate Project RifleSperry Energy Code: 2018 IECC Location: Rifle, Colorado Construction Type: Single-family Project Type: New Construction Project SubType: None Conditioned Floor Area 3,328 ft2 Glazing Area 25% Climate Zone: 5 (6881 MD) Permit Date: Permit Number: All Electric true Is Renewable true Has Charger true Has Battery: true Has Heat Pump: true Construction Site: Owner/Agent: Designer/Contractor: Sperry New Construction Architectural Plans Rifle, CO Compliance: 0.7% Better Than Code Maximum UA: 292 Your UA: 290 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Slab -on -grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab -on -grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Envelope Assem lied Ceiling area of home forming top of insulation 1,368 49.0 0.0 0.026 0.026 36 36 envelope: Flat Ceiling or Scissor Truss Wall area of home forming sides of insulation 1,377 0.0 0.0 0.087 0.082 90 85 envelope: Log Energy efficient door unit: Glass Door (over 50% 42 0.300 0.300 13 13 glazing) Energy efficient door unit: Glass Door (over 50% 42 0.300 0.300 13 13 glazing) Energy efficient door unit: Glass Door (over 50% 21 0.300 0.300 6 6 glazing) Energy efficient door unit: Glass Door (over 50% 21 0.300 0.300 6 6 glazing) Window area of home using energy efficient units: 220 0.260 0.300 57 66 Vinyl Frame Project Title: RifleSperry Report date: 06/04/25 Data filename: Page 1 of10 Basement wall area of home forming bottom of insulation envelope: Solid Concrete or Masonry Wall height: 9.0' 1,334 0.0 10.0 0.052 0.050 69 67 Depth below grade: 9.0' Insulation depth: 9.0' Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Jobe Leonard 6/4/25 Name - Title Signature Date Project Title: RifleSperry Report date: 06/04/25 Data filename: Page 2 of10 REScheck Software Version : REScheck-Web qr(] Inspection checklist 9Y Ener Code: 20181ECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Pre-Inspection/Plan Review Plans Verified Field Verified Complies? & Req.ID I Value Value 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the ❑Not Observable building envelope. Thermal ❑Not Applicable envelope represented on construction documents. 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for I❑Not Observable [PR3]1 lighting and mechanical systems. ❑Not Applicable `L Systems serving multiple dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: LICompiies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable Manual J or other methods Btu/hr Btu/hr El Not Applicable approved by the code official. Additional Comments/Assumptions: Comments/Assumptions 111 High Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3) Project Title: RifleSperry Report date: 06/04/25 Data filename: Page 3 of10 Section Plans Verified Field Verified # Foundation Inspection Value Value & Fie .1 D 402.1.1 :Conditioned basement wall R- [F04]1 insulation R-value. Where interior R- insulation is used, verification - may need to occur during Insulation Inspection. Not required In warm -humid locations in Climate Zone 3. 303.2 Conditioned basement wall [FO5]1 insulation installed per manufacturer's instructions. 402.2.9 :Conditioned basement wall ft [FO6]1 insulation depth of burial or distance from top of wall. J 303.2.1 A protective covering is installed [FO11]2 to protect exposed exterior J insulation and extends a minimum of 6 in. below grade. 403.9 Snow- and ice -melting system [FO12]2 controls installed. Additional Comments/Assumptions: R- R- Complies? Comments/Assumptions ❑Complies See the Envelope Assemblies ❑Does Not table for values. ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not I❑Not Observable ❑Not Applicable ft ❑Complies See the Envelope Assemblies ❑Does Not table for values. ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable [❑Complies ❑Does Not I❑Not Observable ;❑Not Applicable 1 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: RifleSperry Report date: 06/04/25 Data filename: Page 4 of10 :tion I Plans Verified # Framing / Rough -In Inspection Value & Be .I D ` 1 402.1.1, Glazing U-factor (area -weighted U- 402.3.1, average). 402.3.3, 402.5 [FR2]1 303.1.3 U-factors of fenestration products [FR4]1 are determined in accordance with the NFRC test procedure or taken from the default table. 402.4.1.1 Air barrier and thermal barrier [FR23]1 installed per manufacturer's instructions. 402.4.3 Fenestration that is not site built [FR20]1 is listed and labeled as meeting AAMA /WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC 400 that do not exceed code limits. 402.4.5 IC -rated recessed lighting fixtures [FR16]2 sealed at housing/interior finish and labeled to indicate 152.0 cfm leakage at 75 Pa. 403.3.1 Supply and return ducts in attics [FR12]1 insulated >= R-8 where duct is >= 3 inches in diameter and >_ R-6 where < 3 inches. Supply and return ducts in other portions of the building insulated >= R-6 for diameter >= 3 inches and R-4.2 for < 3 inches in diameter. 403.3.2 Ducts, air handlers and filter [FR13]1 boxes are sealed with joints/seams compliant with International Mechanical Code or International Residential Code, as applicable. 403.3.5 Building cavities are not used as [FR15]3 ducts or plenums. 403.4 HVAC piping conveying fluids R-_ [FR17]2 above 105 °F or chilled fluids below 55 °F are insulated to >_R- - . 3. 403.4.1 Protection of insulation on HVAC [FR24]1 piping. Field Verified Complies? Comments/Assumptions Value U- ❑Compiles See the Envelope Assemblies ❑Does Not table for values. ❑Not Observable ❑Not Applicable M 403.5.3 Hot water pipes are insulated to R- R-, [FR18]2 >_R-3. 403.6 'Automatic or gravity dampers are [FR19]z installed on all outdoor air intakes and exhausts. ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable _ ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable (❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable LJComplies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable El Not Applicable 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: RifleSperry Report date: 06/04/25 Data filename: Page 5 of10 Additional Comments/Assumptions: 111 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: RifleSperry Data filename: Report date: 06/04/25 Page 6 of10 Insulation Inspection I Plans Verified Field Verified Value Value 303.1 All installed insulation is labeled [IN13]2 or the installed R-values provided. 402.1.1, Wall insulation R-value. If this is a R- R- 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass [IN3]1 exterior, the exterior insulation ❑Steel ❑Steel requirement applies (FR10). 303.2 Wall insulation is installed per [IN4]1 manufacturer's instructions. Additional Comments/Assumptions: Complies? Comments/Assumptions ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies See the Envelope Assemblies ❑Does Not table for values. ❑Not Observable ❑Not Applicable ucompues ❑Does Not ;❑Not Observable ❑Not Applicable L.ILHigh Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: RifleSperry Report date: 06/04/25 Data filename: Page 7 of10 sections # Final Inspection Provisions Plans Verified Value Field Verified Value Complies? & Re .10 402.1.1, Ceiling insulation R-value. R- R- ❑Complies 402.2.1, ❑ Wood ❑ Wood ❑Does Not 402.2.2, ❑ Steel ❑ Steel ❑Not Observable 402.2.E ❑ Not Applicable [FI1]1 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [FI2]1 Blown insulation marked every ❑Not Observable 300 ft2. ❑Not Applicable Vented attics with air permeable ❑Complies �402.2.3 [FI22]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that ❑Not Observable extends over insulation. ❑Not Applicable 402.2.4 Attic access hatch and door R- R- v❑Complies [FI3]1 insulation >_R-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = [FI17]1 ach in Climate Zones 1-2, and <=3 ach in Climate Zones 3-8. 403.3.3 [FI27]1 403.3.4 [FI4]1 403.3.2.1 [FI24]1 Ducts are pressure tested to cfm/100 determine air leakage with ft2 either: Rough -in test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. Duct tightness test result of <=4 cfm/100 cfm/100 ft2 across the system or ftz <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough -in tests, verification may need to occur during Framing Inspection. Air handler leakage designated by manufacturer at <=2% of design air flow. ACH 50 = ❑Does Not ❑Not Observable ❑Not Applicable cfm/100 ❑Complies ft2 ❑Does Not ❑Not Observable ❑Not Applicable cfm/100 ft2 403.1.1 Programmable thermostats [FI9]2 installed for control of primary heating and cooling systems and initially set by manufacturer to code specifications. 403.1.2 Heat pump thermostat installed [FI10]2 on heat pumps. 403.5.1 Circulating service hot water [F[11]2 systems have automatic or accessible manual controls. ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable DCornplies ❑Does Not ❑Not Observable ❑Not Applicable Comments/Assumptions See the Envelope Assemblies table for values. 1 I High Impact (Tier 1) 2 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3) Project Title: RifleSperry Report date: 06/04/25 Data filename: Page 8 of10 Sectlon 1 Plans Verified Field Verified Complies? # Final Inspection Provisions Value & Rey.ID Value 403.6.1 All mechanical ventilation system ❑Complies [FI25]2 fans not part of tested and listed []Does Not HVAC equipment meet efficacy []Not Observable and air flow limits per Table ❑Not Applicable R403.6.1. 403.2 Hot water boilers supplying heat ❑Complies [FI26]2 through one- or two -pipe heating ❑Does Not systems have outdoor setback ❑Not Observable control to lower boiler water ❑Not Applicable temperature based on outdoor temperature. 403.5.1.1 Heated water circulation systems ❑Complies ❑Does [FI28]2 have a circulation pump. The Not system return pipe is a dedicated ❑Not Observable return pipe or a cold water supply ❑Not Applicable pipe. Gravity and thermos- syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set -point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems _ ❑Complies [FI29]2 'comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically ❑Not Observable adjust the energy input to the ❑Not Applicable heat tracing to maintain the desired water temperature in the piping. 403.5.2 Demand recirculation water ❑Complies [F130]2 systems have controls that ❑Does Not manage operation of the pump ❑Not Observable and limit the temperature of the ❑Not Applicable water entering the cold water piping to <= 104°F. 403.5.4 Drain water heat recovery units ❑Complies [FI31]2 tested in accordance with CSA ❑Does Not B55.1. Potable water -side ❑Not Observable pressure loss of drain water heat ❑Not Applicable recovery units < 3 psi for individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 90% or more of permanent ❑Complies [F16]1 fixtures have high efficacy lamps. ❑Does Not ❑Not Observable ❑Not Applicable 404.1.1 Fuel gas lighting systems have [FI23]3 no continuous pilot light. 401.3 Compliance certificate posted. [FI7]2 ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable UComplies ❑Does Not ❑Not Observable ❑Not Applicable Comments/Assumptions 111 High Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: RifleSperry Report date: 06/04/25 Data filename: Page 9 of10 Final Inspection Provisions Plans Verified Value 303.3 Manufacturer manuals for IFI1813 mechanical and vaster heating systems have been provided. Additional Comments/Assumptions: Field Verified Compiles? Value ❑Complies Does Not ❑Not observable ❑Not Applicable Comments/Assumptlons 111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3) Project Title: RifleSperry Report date: 06/04/25 Data filename: Page 10 of10 l�(018 iECC Energy , Efficiency Certificate Insulation Rating R-Value Above -Grade Wall 0.00 Below -Grade Wall 10.00 Floor 0.00 Ceiling / Roof 49.00 Ductwork (unconditioned spaces): Glass & Door Rating • Window 0.26 0.25 Door 0.30 CoolingHeating & Heating System: Cooling System: Water Heater; Name: _ Date: Comments