Loading...
HomeMy WebLinkAboutEngineer's Framing DetailSCALE SHEET NO. drawn by date description 68 B a l d E a g l e W a y Ca r b o n d a l e , C O 8 1 6 2 3 El a i n e G e r s o n 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 101 ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 LEGEND N.T.S. PERSPECTIVE VIEW DV NOTE: Beams are continuously attached to Host Structure Elevation: At Grade ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 Please Note: A Structural Engineer, PE shall be employed prior to the construction of this pergola to verify that the design meets current applicable codes and is structually sound! SCALE SHEET NO. drawn by date description 68 B a l d E a g l e W a y Ca r b o n d a l e , C O 8 1 6 2 3 El a i n e G e r s o n 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 102 1/4" = 1'-0" TOP VIEW HOST STRUCTURE C B A 123454' 498.00" 63.00" 121.75" 244.25" beam (tbd on site)249.75" beam (tbd on site) 124.50"124.50"127.25" 247.00" beam 247.00" beam 12 0 . 0 0 " 60 . 0 0 " 11 6 . 0 0 " b e a m 60 . 0 0 " 11 6 . 0 0 " b e a m Perimeter Beam 2"x10" Perimeter Beam 2"x10" @ Host Structure Beam Chase 5.5" Perimeter Beam 2"x10" @ Host Structure Perimeter Beam 2"x10" Perimeter Beam 2"x10" @ Host Structure Perimeter Beam 2"x10"NOTE:See Sheet A300 "Louvers" detail A200 1-1 A200 1-1 A1 A200 A1 A200 183.25"251.75" DV ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 NOTE: Beams are continuously attached to Host Structure Elevation: At Grade Please Note: A Structural Engineer, PE shall be employed prior to the construction of this pergola to verify that the design meets current applicable codes and is structually sound! NOTE 1: See Sheet A306 "Typical Beam Chase to Beam Connection Pass Through Gutter" detail SCALE SHEET NO. drawn by date description 68 B a l d E a g l e W a y Ca r b o n d a l e , C O 8 1 6 2 3 El a i n e G e r s o n 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 103 1/4" = 1'-0" BEAMS & gutter PLAN HOST STRUCTURE C B A 123454' 498.00" 63.00" 121.75" 244.25.00" beam (tbd on site)249.75" beam (tbd on site) 124.50"124.50"127.25" 183.25"251.75" 247.00" beam 247.00" beam 12 0 . 0 0 " 60 . 0 0 " 11 6 . 0 0 " b e a m 60 . 0 0 " 11 6 . 0 0 " b e a m Perimeter Beam 2"x10" Perimeter Beam 2"x10" @ Host Structure Beam Chase 5.5" Perimeter Beam 2"x10" @ Host Structure Perimeter Beam 2"x10" Perimeter Beam 2"x10" @ Host Structure Perimeter Beam 2"x10" A200 1-1 A200 1-1 A1 A200 A1 A200 P3 - Aluminum Post 8"x8"P2 - Aluminum Post 8"x8" Aluminum Gutter 7.5" Aluminum Gutter 7.5" Aluminum Gutter 7.5" Aluminum Gutter 7.5" Interior Beam 2"x10" Interior Beam 2"x10" Interior Beam 2"x10" Interior Beam 2"x10" Interior Beam 2"x10" Interior Beam 2"x10"Beam Chase 5.5" Beam Chase 5.5" Beam Chase 5.5" 9.50"100.00"24.50"100.00"24.50"100.00"24.50"98.00"17.00" 9. 5 0 " 9. 5 0 " 10 1 . 0 0 " NOTE 1NOTE 1NOTE 1 NOTE 1NOTE 1NOTE 1 NOTE:See Sheet A303 "Beam Splice - 2x10 Beam" detail NOTE:See Sheet A304 "Beam Splice - 2x10 Beam at Post" detail Exact location TBD on site. 11 6 . 0 0 " b e a m 11 6 . 0 0 " b e a m 11 6 . 0 0 " b e a m 11 6 . 0 0 " b e a m 11 6 . 0 0 " b e a m 11 6 . 0 0 " b e a m NOTE: Pergola to be fastened into the house with LedgerLok Ledger to House Connections (By Others) 59.00" 60.00" 3.00" DV ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 Please Note: A Structural Engineer, PE shall be employed prior to the construction of this pergola to verify that the design meets current applicable codes and is structually sound! SCALE SHEET NO. drawn by date description 68 B a l d E a g l e W a y Ca r b o n d a l e , C O 8 1 6 2 3 El a i n e G e r s o n 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 200 1/4" = 1'-0" SECTION PLANs A1 SIDE SECTION A200 1-1 FRONT SECTION A200 1 2 3 4 4'5 HO S T S T R U C T U R E 9.50" Beam Chase 5.5" Perimeter Beam 2"x10" @ Host Structure Gutter Perimeter Beam 2"x10" P2 - Aluminum Post 8"x8" P3 - Aluminum Post 8"x8" 113.00"9.50"115.00"9.50"115.00"9.50"115.00"2.00" 498.00" 127.25"124.50"124.50"121.75" 251.75"183.25"63.00" Interior Beam 2"x10" Interior Beam 2"x10" Interior Beam 2"x10" Interior Beam 2"x10" Interior Beam 2"x10" Interior Beam 2"x10" Gutter Beam Chase 5.5"Beam Chase 5.5"Beam Chase 5.5" Gutter Gutter Gutter Gutter Gutter GutterLouversLouversLouvers Louvers 12 0 . 0 0 " NOTE:See Sheet A309 "Beam Chase to Host Structure Connection" detail A 120.00" 60.00"60.00" B C HO S T S T R U C T U R E Perimeter Beam 2"x10" @ Host Structure Gutter 2.00" Perimeter Beam 2"x10" Gutter Louvers NOTE:See Sheet A309 "Beam to Host Structure Connection" detail P1 - Aluminum Post 8"x8" 12 0 . 0 0 " 116.00"2.00" NOTE:See Sheet A310 "Functional Post Bracket to Footer Connection" detail NOTE:See Sheet A310 "Functional Post Bracket to Footer Connection" detail NOTE:See Sheet A310 "Functional Post Bracket to Footer Connection" detail NOTE: Pergola to be fastened into the house with LedgerLok Ledger to House Connections (By Others) 59.00" DV PIVOT BAR CAP TRACK BAR BEAM PIVOT BAR PIVOT PIN LOUVER BEAM LOUVER TRACK BAR PIN PUSH NUT TRACK BAR BEAM TRACK PIN 5/16" DIA. S.S. W/ 1/2" ENGAGEMENT MIN. PIVOT BAR LOUVER PUSH NUT TRACK BAR PIN TRACK BAR #10 SS TEK SCREW @ 6" O.C PIVOT BAR CAP LOUVERS TO BEAM CONNECTION (2X10 BEAM) 1 1 2" = 1'-0" SIDE VIEW 1 1 2" = 1'-0" ISOMETRIC OUT-SIDE VIEW 1 1 2" = 1'-0" ISOMETRIC IN-SIDE VIEW 1 1 2" = 1'-0" LOUVERS DETAIL 1 1 2" = 1'-0" 6" o.c.6" o.c.6" o.c.6" o.c.6" o.c.6" o.c.6" o.c.6" o.c.6" o.c. 12"12"12"12" 6" 1. 8 6 6 " 0. 0 6 5 " BEAM, 2"x10" PIVOT TRACK PIVOT CAP PIVOT PIN LOUVER PROFILE FOR COMPARISON #10 SS TEK SCREW @ 6" O.C SCALE SHEET NO. drawn by date description 68 B a l d E a g l e W a y Ca r b o n d a l e , C O 8 1 6 2 3 El a i n e G e r s o n 10/06/22 dk 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 300 1 1/2" = 1'-0" DETAILS ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 INTERIOR BEAMPERIMETER BEAM 9" U-PROFLE CORNER BEAM CONNECTION (5) #14 DIA. TEK SCREWS PERIMETER BEAM (5) #14 DIA. TEK SCREWS (5) #14 DIA. TEK SCREWS 5.5" GUTTER 11.5" COVER SHEET 10 . 0 0 " BEAM 2" X 10"COVER SHEET BEAM 2" X 10" 2" X 1 3/4" X 0.125" BEAM INSERT, 9" IN LENGTH (5) #14 TEK SCREWS THROUGH BEAM INTO INSERT EACH SIDE (5) #14 TEK SCREWS THROUGH INSERT INTO PERIMETER BEAM, EACH SIDE #14 TEK SCREWS THROUGH GUTTER INTO BEAM EACH SIDE, SPACED 14" - 16" O.C. (BASED ON OVERALL BEAM CHASE LENGTH), EACH SIDE GUTTER (10) #14 TEK SCREWS THROUGH BEAM INTO CORNER BEAM CONNECTION EACH SIDE BEAM 2" X 10"BEAM 2" X 10" 5.5" GUTTER CORNER BEAM CONNECTION - EXTRUDED WITH CAPS 2.00"5.50"2.00" 2. 0 0 " BEAM 2" X 10" TYPICAL CORNER ASSEMBLY BEAM CHASE TO SINGLE BEAM - 2" X 10" BEAM / 5.5 GUTTER 1 1 2" = 1'-0" ISOMETRIC VIEWSIDE VIEW TOP VIEW SCALE SHEET NO. drawn by date description 68 B a l d E a g l e W a y Ca r b o n d a l e , C O 8 1 6 2 3 El a i n e G e r s o n 10/06/22 dk 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 301 1 1/2" = 1'-0" DETAILS ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 CORNER BEAM CONNECTION PERIMETER BEAM (8) OR (10) #14 TEK SCREWS CORNER BEAM CONNECTION (8) OR (10) #14 TEK SCREWS (DEPENDING ON THE BEAM SIZE) THROUGH BEAM INTO CORNER BEAM CONNECTION EACH SIDE BEAM TOP VIEW (8) OR (10) #14 TEK SCREWS (DEPENDING ON THE BEAM SIZE) THROUGH BEAM INTO CORNER BEAM CONNECTION EACH SIDE BEAM BEAM SIDE VIEW CORNER BEAM CONNECTION - EXTRUDED WITH CAPS BEAM TYPICAL CORNER ASSEMBLY 3" = 1'-0" ISOMETRIC VIEW SCALE SHEET NO. drawn by date description 68 B a l d E a g l e W a y Ca r b o n d a l e , C O 8 1 6 2 3 El a i n e G e r s o n 10/06/22 dk 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 302 3" = 1'-0" DETAILS ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 14" U CHANNEL INSIDE PERIMETER BEAM 2" X 10" PERIMETER BEAM 1 3/4" X 3 3/4" X 0.125" SPLICE U-CHANNEL 2" X 10" BEAM(6) #14 TEK SCREWS PER BEAM #14 TEK SCREW [12] #14 TEK SCREWS [12] #14 TEK SCREWS PERIMETER BEAM U-CHANNEL 3/4"X2"X.125 14" PIECES - 7 - INCHES INSIDE OF PERIMETER BEAM SCREWED TOGETHER USING 12 TEK SCREWS 1" O.C. IN THE TOP OF PERIMETER BEAM SPLICE ARE PLACED AT POST POSITIONS2" LENGTH 1"1"1"1"1"1"1"1"1"1"1" BEAM SPLICE - 2X10 BEAM 1 1 2" = 1'-0" ISOMETRIC VIEW SIDE VIEW TOP VIEW 3" = 1'-0" 10 . 0 0 " SCALE SHEET NO. drawn by date description 68 B a l d E a g l e W a y Ca r b o n d a l e , C O 8 1 6 2 3 El a i n e G e r s o n 10/06/22 dk 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 303 1 1/2" = 1'-0" DETAILS ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 TEK SCREWS POST BEAM CHANNEL POST [12] #14 TEK SCREWS 1 3/4" X 3 3/4" X 0.125" SPLICE U-CHANNEL 2" X 10" BEAM(6) #14 TEK SCREWS PER BEAM #14 TEK SCREWS BEAM TO POST BRACKET CONNECTION 2" LENGTH 1"1"1"1"1"1"1"1"1"1"1" BEAM SPLICE - 2X10 BEAM AT POST 1 1 2" = 1'-0" 14" U CHANNEL INSIDE PERIMETER BEAM #14 TEK SCREW [12] #14 TEK SCREWS PERIMETER BEAM U-CHANNEL 3/4"X2"X.125 14" PIECES - 7 - INCHES INSIDE OF PERIMETER BEAM SCREWED TOGETHER USING 12 TEK SCREWS 1" O.C. IN THE TOP OF PERIMETER BEAM SPLICE ARE PLACED AT POST POSITIONS ISOMETRIC VIEW SIDE VIEW TOP VIEW 3" = 1'-0" 2" X 10" PERIMETER BEAM [12] #14 TEK SCREWS 10 . 0 0 " SCALE SHEET NO. drawn by date description 68 B a l d E a g l e W a y Ca r b o n d a l e , C O 8 1 6 2 3 El a i n e G e r s o n 10/06/22 dk 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 304 1 1/2" = 1'-0" DETAILS ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 BEAM 2" X 10" 7.5" COVER SHEET 5.5" GUTTER BEAM 2" X 10" 10 " 2"5 1/2"2" 9 1/2" #14 TEK SCREWS SPACED 16" O.C. #14 TEK SCREWS SPACED 16" O.C. #14 TEK SCREWS THROUGH GUTTER INTO BEAM EACH SIDE, SPACED 14" - 16" O.C. (BASED ON OVERALL BEAM CHASE LENGTH) 7.5" COVER SHEET BEAM 2" X 10" BEAM 2" X 10" 5.5" GUTTER TYPICAL BEAM CHASE 2" x 10" BEAMS, 5.5" GUTTER 3" = 1'-0" ISOMETRIC VIEW 1 1 2" = 1'-0" #14 TEK SCREWS THROUGH GUTTER INTO BEAM EACH SIDE, SPACED 14" - 16" O.C. (BASED ON OVERALL BEAM CHASE LENGTH) SCALE SHEET NO. drawn by date description 68 B a l d E a g l e W a y Ca r b o n d a l e , C O 8 1 6 2 3 El a i n e G e r s o n 10/06/22 dk 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 305 varies DETAILS ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 GUTTER ASSEMBLY 7.5" 1 1 2" = 1'-0" TOP VIEW BEAM BEAM 7.5" GUTTER GUTTER CORNER CORNER BEAM CONNECTION 7.5" GUTTER #14 TEK SCREW (2-PLACES) (4) #14 TEK SCREWS SIDE VIEW CORNER BEAM CONNECTION GUTTER CORNER BEAM BEAM 7.5" 3" 12.00" 1" #14 TEK SCREW 1" DOWN FROM TOP OF GUTTER EVERY 12" 7.5" GUTTER BEAM ISOMETRIC VIEW CORNER BEAM CONNECTION BEAM BEAM 7.5" GUTTER 7.5" GUTTER GUTTER CORNER (2) #14 TEK SCREWS (2) #14 TEK SCREWS BEAM 2" X 10"BEAM 2" X 10" 3" INSERT / U CHANNEL BEAM 2" X 10" NOTCHED BEAMS 5.125" X 3.125" CUT PASS THROUGH GUTTER COVER PASS THROUGH GUTTER (4) #14 TEK SCREWS TYPICAL BEAM CHASE TO BEAM CONNECTION PASS THROUGH GUTTER 5.5" 1 1 2" = 1'-0" ISOMETRIC VIEW TOP VIEW SIDE VIEW 10 . 0 0 " BEAM 2" X 10"COVER SHEET BEAM 2" X 10" 2" X 1 3/4" X 0.125" BEAM INSERT, 3" IN LENGTH, EACH SIDE (2) #14 TEK SCREWS THROUGH BEAM INTO INSERT EACH SIDE (2) #14 TEK SCREWS THROUGH INSERT INTO PERIMETER BEAM, EACH SIDE #14 TEK SCREWS THROUGH GUTTER INTO BEAM EACH SIDE, SPACED 14" - 16" O.C. (BASED ON OVERALL BEAM CHASE LENGTH), EACH SIDE GUTTER 3" BEAM INSERT 3" BEAM INSERT BEAM 2" X 10"BEAM 2" X 10" 2.00"5.50" OR 7.50"2.00" #14 TEK SCREWS THROUGH BEAM INTO INSERT EACH SIDE #14 TEK SCREWS THROUGH INSERT INTO BEAM #14 TEK SCREWS THROUGH INSERT INTO BEAM SCALE SHEET NO. drawn by date description 68 B a l d E a g l e W a y Ca r b o n d a l e , C O 8 1 6 2 3 El a i n e G e r s o n 10/06/22 dk 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 306 1 1/2" = 1'-0" DETAILS ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 BEAM GUTTER U-CHANNEL 2”x1 ¾”x2”x0.125” 7" IN LENGTH (4) #14 X 1" TEK SCREWS THRU U-CHANNEL INTO GUTTER (4) #14 X 1" TEK SCREWS THRU FAN BEAM INTO INSERT EA. SIDE FAN BEAM U CHANNEL 2”x1 ¾”x2”x0.125” 7" IN LENGTH BEAM GUTTER FAN BEAM CONNECTION 3" = 1'-0" (4) #14 X 1" TEK SCREWS THRU INSERT INTO GUTTER (4) #14 X 1" TEK SCREWS THRU FAN BEAM INTO INSERT EA. SIDE SCALE SHEET NO. drawn by date description 68 B a l d E a g l e W a y Ca r b o n d a l e , C O 8 1 6 2 3 El a i n e G e r s o n 10/06/22 dk 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 307 3" = 1'-0" DETAILS ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 #14 TEK SCREWS POST CHANNEL #14 TEK SCREWS BOTH SIDE PERIMETER BEAM 2"x10" PERIMETER BEAM 2"x10" [6] #14 x 1" TEK SCREWS THRU CHANNEL INTO BEAM 7 3/4" x 2" x 0.125 x 7 3/4" CHANNEL LOWER BEAM AND CHANNEL INTO POST [3] #14 x 1" TEK SCREWS THRU POST INTO CHANNEL EA. SIDE 8" x 8" x 0.1875" POST SINGLE 2X10 BEAM TO 8X8 POST CONNECTION 3" = 1'-0" SCALE SHEET NO. drawn by date description 68 B a l d E a g l e W a y Ca r b o n d a l e , C O 8 1 6 2 3 El a i n e G e r s o n 10/06/22 dk 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 308 3" = 1'-0" DETAILS ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 ALUMINUM BEAM PER PLAN 9/16" HOLE DRILLED FOR SCREW INSTALLATION 1" 1" 16" 32" O.C.32" O.C. 9/16" HOLE DRILLED FOR SCREW INSTALLATION TYPICAL 16" O.C. STUDS 1" 1" 32" O.C.32" O.C. 16"16"16" EXISTING HOST STRUCTURE SHALL BE EITHER 3000 PSI POURED CONCRETE, OR ASTM90 HOLLOW / GROUT-FILLED CMU OR #2 SYP WOOD (G=0.55) AS VERIFIED BY OTHERS 3" M I N . EMBED. TYPICAL ANCHOR PATTERN (TO WOOD STUDS SHOWN) HOST STRUCTURE GUTTER PERIMETER BEAM BEAM TO HOST STRUCTURE CONNECTION 1 1 2" = 1'-0" NOTE: PERGOLA TO BE FASTENED INTO THE HOUSE WITH LEDGERLOK LEDGER TO HOUSE CONNECTIONS (BY OTHERS) FOR CONCRETE ATTACHMENT: [2] 1/4" DIAM. ITW STAINLESS STEEL TAPCON INTO WALL W/ 3" EMBEDMENT AND 3" EDGE DISTANCE, SPACED 12" O.C. STAGGERED FOR WOOD ATTACHMENT: [2] 1/4" DIAM. S.S. WOOD LAG SCREWS INTO WALL W/ 3" THREAD ENGAGEMENT AND 3/4" MINIMUM EDGE DISTANCE, SPACED 16" O.C. STAGGERED FOR HOLLOW CMU ATTACHMENT: [2] 1/4" DIAM. S.S. HILTI KWIK-CON II+ INTO BLOCK FACE W/ 1-3/4" EMBEDMENT AND 3" MINIMUM EDGE DISTANCE, SPACED 12" O.C. STAGGERED ALUMINUM BEAM PER PLAN 9/16" HOLE DRILLED FOR SCREW INSTALLATION 1" 1" 16" 32" O.C.32" O.C. 9/16" HOLE DRILLED FOR SCREW INSTALLATION TYPICAL 16" O.C. STUDS 1" 1" 32" O.C.32" O.C. 16"16"16" EXISTING HOST STRUCTURE SHALL BE EITHER 3000 PSI POURED CONCRETE, OR ASTM90 HOLLOW / GROUT-FILLED CMU OR #2 SYP WOOD (G=0.55) AS VERIFIED BY OTHERS 3" M I N . EMBED. TYPICAL ANCHOR PATTERN (TO WOOD STUDS SHOWN) STANDARD GUTTER LOUVERS MUST RUN PARALLEL TO HOST FOR THIS DETAIL HOST STRUCTURE GUTTER PERIMETER BEAM BEAM CHASE TO HOST STRUCTURE CONNECTION 1 1 2" = 1'-0" SCALE SHEET NO. drawn by date description 68 B a l d E a g l e W a y Ca r b o n d a l e , C O 8 1 6 2 3 El a i n e G e r s o n 10/06/22 dk 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 309 1 1/2" = 1'-0" DETAILS ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 FUNCTIONAL POST BRACKET TO FOOTER CONNECTION 8"x8" 1 1 2" = 1'-0" 8" x 8" POST 8" x 8" X 0.1875" FUNCTIONAL POST BASE 12" TALL #14 TEK SCREWS EACH SIDE CONCRETE ANCHORS 1 2" Ø RAMSET/ RED HEAD LDT, 4 1 2" EMBEDMENT, 6" MIN EDGE DISTANCE, 5" SPACING CONCRETE ANCHORS 1.00" 1.00" 1.00" 0.50" 1.00" 1.00" 1.00" 0.50" 7. 1 2 5 " 7.625" 1. 0 0 " 5. 0 0 " 1. 0 0 " 12 . 0 0 " 36 . 0 0 " FOOTER 3000 PSI CONCRETE MIN. 36.00" SQUARE 8" x 8" POST 8" x 8" X 0.1875" FUNCTIONAL POST BASE 12" TALL #14 TEK SCREWS EACH SIDE SCALE SHEET NO. drawn by date description 68 B a l d E a g l e W a y Ca r b o n d a l e , C O 8 1 6 2 3 El a i n e G e r s o n 10/06/22 dk 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 310 1 1/2" = 1'-0" DETAILS ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 SCALE SHEET NO. drawn by date description 68 B a l d E a g l e W a y Ca r b o n d a l e , C O 8 1 6 2 3 El a i n e G e r s o n 10/06/22 dk 154 ETHAN ALLEN DR. DAHLONEGA, GA 30533 (800) 303-5248 A 400 N.T.S. MOTOR SPECIFICATIONS ALUMINUM TYPE: LOUVERS 6063-T5 ALL OTHER COMPONENTS 6063-T6 VALID ONLY FOR ZIP CODE: 81601 VALID ONLY FOR: CARBON CUSTOMS FOR PERMIT USE WITHIN 14 DAYS OF DIGITAL SEAL PE0053085 VALID ONLY FOR ZIP CODE: 81601 VALID ONLY FOR: CARBON CUSTOMS FOR PERMIT USE WITHIN 14 DAYS OF DIGITAL SEAL PE0053085 VALID ONLY FOR ZIP CODE: 81601 VALID ONLY FOR: CARBON CUSTOMS FOR PERMIT USE WITHIN 14 DAYS OF DIGITAL SEAL PE0053085 SIGNED: 04/11/2023 Š Š Š Š Š Š ŠŠ VALID FOR 1 PERMIT ONLY U.N.O. RE M A R K S DR W N CH K D DA T E SCALE: COPYRIGHT ENGINEERING EXPRESSŠ C: \ U s e r s \ c o l b y \ E n g i n e e r i n g E x p r e s s \ P r o d u c t i o n - D o c u m e n t s \ P r o j e c t s \ 2 1 - 4 0 4 6 0 P I V O T 6 X L M A S T E R P L A N S H E E T \ W o r k \ D r a w i n g s & C A D \ 2 1 - 4 0 4 6 0 d P I V O T 6 X L M P S . d w g 07 / 2 3 / 2 0 2 1 - 4 : 1 6 p m co l b y IN I T I S S U E CC B AE M 7/ 2 3 / 2 1 - - - - - - - - - - - - - - - - UNLOADED OUTER BEAM, TYP. HOST STRUCTURE, BY OTHERS LEDGER BEAM MID POST, TYP. MAIN BEAM, TYP. BEAM TO MID POST, TYP. 1 12 LEDGER TO HOST MA X H E I G H T P E R CO L U M N S C H E D U L E PAN SPAN (SEE SCHEDULES) MAIN BEAM (OR UNLOADED OUTER BEAM) BEAM TO CORNER POST, TYP. GRADE MAIN BEAM SPAN (SEE SCHEDULES) MAIN BEAM (OR UNLOADED OUTER BEAM) MAIN BEAM SPAN (SEE SCHEDULES) N.T.S.SIDE ELEVATIONN.T.S. FREESTANDING & HOST ATTACHED (MULTI-BAY) FRONT ELEVATION DIAGONAL BRACING OPTION, SEE SEPARATE DETAIL FOR ATTACHMENT, TYP. CORNER POST, TYP. MID POST, TYP. -- 4 HOST ATTACHED (MULTI-BAY) BEAM TO CORNER POST, TYP. PAN SPAN (SEE SCHEDULES) MAIN BEAM, TYP. -- 10 DIAGONAL BRACING OPTION, SEE SEPARATE DETAIL FOR ATTACHMENT, TYP. CORNER POST, TYP. MAIN BEAM SPAN (SEE SCHEDULES) RO O F P A N S P A N (S E E S C H E D U L E S ) MAIN BEAM MAIN BEAM SPAN (SEE SCHEDULES) MAIN BEAM 3 3 BEAM TO CORNER POST N.T.S. HOST ATTACHED (MULTI-BAY) PLAN RO O F P A N S P A N (S E E S C H E D U L E S ) HOST STRUCTURE, BY OTHERSLEDGER BEAM, TYP. 4 3 MAIN BEAM SPAN (SEE SCHEDULES) RO O F P A N S P A N (S E E S C H E D U L E S ) UNLOADED OUTER BEAM, TYP. MAIN BEAM ROOF PANS, TYP. MAIN BEAM SPAN (SEE SCHEDULES) MAIN BEAM CORNER POST, TYP. 3 3 BEAM TO CORNER POST, TYP. N.T.S. FREESTANDING (MULTI-BAY) PLAN RO O F P A N S P A N (S E E S C H E D U L E S ) MAIN BEAM, TYP. 3 3 BEAM TO MID POST, TYP. MULTI-BAY DEFINITION A BAY IS DEFINED IN THIS DOCUMENT AS THE RECTANGULAR REGION BETWEEN (4) NEIGHBORING POSTS OR (2) POSTS AND A SIDE SUPPORTED BY THE HOST STRUCTURE (BY OTHERS). SEE CIRCLED REGIONS BELOW. THE DETAILS ON THE PREVIOUS PAGES DEPICT SINGLE-BAY AND DOUBLE-BAY SCENARIOS. THE DETAILS ON THIS PAGE DEPICT MULTI-BAY SCENARIOS ORGANIZED INTO A 2 x 2 MATRIX. OTHER MULTI-BAY SCENARIOS ARE ALLOWED UP TO A MAXIMUM OF (4) BAYS, SUBJECT TO ALL LIMITATIONS AND SPECIFICATIONS STATED HEREIN. PLEASE CONTACT THIS OFFICE FOR ADDITIONAL CLARIFICATIONS AND/OR CONFIGURATIONS. MA X H E I G H T P E R CO L U M N S C H E D U L E -- 7 POST BASE ATTACHMENT, TYP. -- 8 SEE NOTE 1 THIS PAGE BEAM TO MID POST, TYP. MULTI-BAY LAYOUT SECTIONS & PLANS (3+ BAYS) 6 11 7 11 -- 7 POST BASE ATTACHMENT, TYP. -- 8 6 11 7 11 UNLOADED OUTER BEAM, TYP. ROOF PANS, TYP. CORNER POST, TYP. BEAM TO MID POST, TYP. PHOTOCOPIES NOT TO BE USED Š Š Š Š Š Š ŠŠ VALID FOR 1 PERMIT ONLY U.N.O. RE M A R K S DR W N CH K D DA T E SCALE: COPYRIGHT ENGINEERING EXPRESSŠ C: \ U s e r s \ c o l b y \ E n g i n e e r i n g E x p r e s s \ P r o d u c t i o n - D o c u m e n t s \ P r o j e c t s \ 2 1 - 4 0 4 6 0 P I V O T 6 X L M A S T E R P L A N S H E E T \ W o r k \ D r a w i n g s & C A D \ 2 1 - 4 0 4 6 0 d P I V O T 6 X L M P S . d w g 07 / 2 3 / 2 0 2 1 - 4 : 1 6 p m co l b y IN I T I S S U E CC B AE M 7/ 2 3 / 2 1 - - - - - - - - - - - - - - - - UNLOADED OUTER BEAM, TYP. HOST STRUCTURE, BY OTHERS LEDGER BEAM MID POST, TYP. MAIN BEAM, TYP. BEAM TO MID POST, TYP. 1 12 LEDGER TO HOST MA X H E I G H T P E R CO L U M N S C H E D U L E PAN SPAN (SEE SCHEDULES) MAIN BEAM (OR UNLOADED OUTER BEAM) BEAM TO CORNER POST, TYP. GRADE MAIN BEAM SPAN (SEE SCHEDULES) MAIN BEAM (OR UNLOADED OUTER BEAM) MAIN BEAM SPAN (SEE SCHEDULES) N.T.S.SIDE ELEVATIONN.T.S. FREESTANDING & HOST ATTACHED (MULTI-BAY) FRONT ELEVATION DIAGONAL BRACING OPTION, SEE SEPARATE DETAIL FOR ATTACHMENT, TYP. CORNER POST, TYP. MID POST, TYP. -- 4 HOST ATTACHED (MULTI-BAY) BEAM TO CORNER POST, TYP. PAN SPAN (SEE SCHEDULES) MAIN BEAM, TYP. -- 10 DIAGONAL BRACING OPTION, SEE SEPARATE DETAIL FOR ATTACHMENT, TYP. CORNER POST, TYP. MAIN BEAM SPAN (SEE SCHEDULES) RO O F P A N S P A N (S E E S C H E D U L E S ) MAIN BEAM MAIN BEAM SPAN (SEE SCHEDULES) MAIN BEAM 3 3 BEAM TO CORNER POST N.T.S. HOST ATTACHED (MULTI-BAY) PLAN RO O F P A N S P A N (S E E S C H E D U L E S ) HOST STRUCTURE, BY OTHERSLEDGER BEAM, TYP. 4 3 MAIN BEAM SPAN (SEE SCHEDULES) RO O F P A N S P A N (S E E S C H E D U L E S ) UNLOADED OUTER BEAM, TYP. MAIN BEAM ROOF PANS, TYP. MAIN BEAM SPAN (SEE SCHEDULES) MAIN BEAM CORNER POST, TYP. 3 3 BEAM TO CORNER POST, TYP. N.T.S. FREESTANDING (MULTI-BAY) PLAN RO O F P A N S P A N (S E E S C H E D U L E S ) MAIN BEAM, TYP. 3 3 BEAM TO MID POST, TYP. MULTI-BAY DEFINITION A BAY IS DEFINED IN THIS DOCUMENT AS THE RECTANGULAR REGION BETWEEN (4) NEIGHBORING POSTS OR (2) POSTS AND A SIDE SUPPORTED BY THE HOST STRUCTURE (BY OTHERS). SEE CIRCLED REGIONS BELOW. THE DETAILS ON THE PREVIOUS PAGES DEPICT SINGLE-BAY AND DOUBLE-BAY SCENARIOS. THE DETAILS ON THIS PAGE DEPICT MULTI-BAY SCENARIOS ORGANIZED INTO A 2 x 2 MATRIX. OTHER MULTI-BAY SCENARIOS ARE ALLOWED UP TO A MAXIMUM OF (4) BAYS, SUBJECT TO ALL LIMITATIONS AND SPECIFICATIONS STATED HEREIN. PLEASE CONTACT THIS OFFICE FOR ADDITIONAL CLARIFICATIONS AND/OR CONFIGURATIONS. MA X H E I G H T P E R CO L U M N S C H E D U L E -- 7 POST BASE ATTACHMENT, TYP. -- 8 SEE NOTE 1 THIS PAGE BEAM TO MID POST, TYP. MULTI-BAY LAYOUT SECTIONS & PLANS (3+ BAYS) 6 11 7 11 -- 7 POST BASE ATTACHMENT, TYP. -- 8 6 11 7 11 UNLOADED OUTER BEAM, TYP. ROOF PANS, TYP. CORNER POST, TYP. BEAM TO MID POST, TYP. PHOTOCOPIES NOT TO BE USED Š Š Š Š Š Š ŠŠ VALID FOR 1 PERMIT ONLY U.N.O. RE M A R K S DR W N CH K D DA T E SCALE: COPYRIGHT ENGINEERING EXPRESSŠ C: \ U s e r s \ c o l b y \ E n g i n e e r i n g E x p r e s s \ P r o d u c t i o n - D o c u m e n t s \ P r o j e c t s \ 2 1 - 4 0 4 6 0 P I V O T 6 X L M A S T E R P L A N S H E E T \ W o r k \ D r a w i n g s & C A D \ 2 1 - 4 0 4 6 0 d P I V O T 6 X L M P S . d w g 07 / 2 3 / 2 0 2 1 - 4 : 1 6 p m co l b y IN I T I S S U E CC B AE M 7/ 2 3 / 2 1 - - - - - - - - - - - - - - - - PHOTOCOPIES NOT TO BE USED OR SCAN THIS CODE ABBREVIATIONS: HOST ATTACHED CANOPY/PATIO COVER ISOMETRIC (TABLE 3-ROOF, OPEN WALL) MAIN RESIDENCE FLAT OR LOW ROOF SLOPE He Hc FOR TABLE 3 WIND SPEED TO PRESSURE LOAD COMBINATION CONVERSION TABLES FOR CANOPIES & PERGOLAS WITH 50% ROOF POROSITY ASD DESIGN LOAD COMBINATION PRESSURES CONSIDER DL= 3 PSF, LR = 20 PSF, S = 20 PSF, AND WIND LOAD, W AS CALCULATED FOR THE SELECTED STRUCTURE USING ASCE 7-16 Vult WIND SPEED & ASD PRESSURE METHOD & CALCULATED AT MEAN SEA LEVEL FOR OPEN-WALLED CANOPY STRUCTURES WITH AT LEAST 50% ROOF POROSITY DESIGN NOTES 1.PRESSURES HEREIN ARE CALCULATED IN CONFORMANCE WITH (ASD) "ALLOWABLE STRESS DESIGN METHODOLOGY" PER IBC (2018) / FBC (2020) SECTION 1605 & ASCE 7-16 SECTION 2.4.1, WITH WIND PRESSURES PER ASCE CHAPTER 30, AND LOADING CONDITIONS USING THE CODES & CRITERIA AS OUTLINED. 2.'WORST CASE' CRITICAL CONDITIONS SHALL BE ASSUMED FOR SAFE PRESSURE RATINGS. 3.TOPOGRAPHIC FACTOR Kzt=1.0 FOR FLAT TERRAIN USE ONLY. NO HILLS SHALL BE NEARBY AREA. 4.VERIFY USE OF Kd (DIRECTIONALITY FACTOR) WITH LOCAL BUILDING DEPARTMENT, Kd=0.85 USED HEREIN. PRESSURES SHALL BE ADJUSTED AS REQUIRED BY USE OF ALTERNATE Kd VALUES. GENERAL NOTES 5.THIS DOCUMENT IS NOT A SITE-SPECIFIC DOCUMENT & DOES NOT PERTAIN TO ANY SPECIFIC RESIDENCE. 6.THIS DOCUMENT IS ONLY VALID WITH AN ORIGINAL SIGNATURE & RAISED SEAL OR DIGITALLY SEALED. 7.THIS DOCUMENT ILLUSTRATES ALLOWABLE DESIGN WIND PRESSURES (ASD) AS LISTED. APPLICATION OF THESE TABLES AND CORRESPONDING WIND VELOCITY (SPEED), EXPOSURE, & OTHER COEFFICIENTS LISTED HEREIN SHALL BE DICTATED AND VERIFIED BY THE GOVERNING BUILDING DEPARTMENT AND PERMIT HOLDER. 8.NO WARRANTY FOR APPLICABILITY OF THE USE OF THESE TABLES IS OFFERED HEREIN. 9.THIS SPECIFICATION DOES NOT OFFER ANY PRODUCT APPROVED CERTIFICATION. REFER TO ANY SEPARATELY SUBMITTED TEST CRITERIA AND OTHER APPROVALS FOR DESIGN & INSTALLATION INFORMATION AND APPLICABILITY OF THESE TABLE VALUES WHICH IS TO BE VERIFIED BY OTHERS IN ACCORDANCE WITH GOVERNING CODES. 10.CONTRACTOR SHALL INVESTIGATE AND CONFORM TO ALL LOCAL BUILDING CODE AMENDMENTS WHICH MAY APPLY. 11.IT IS RECOMMENDED THAT A LICENSED ENGINEER OR REGISTERED ARCHITECT PREPARE SITE SPECIFIC DOCUMENTS FOR USE IN CONJUNCTION WITH THIS DOCUMENT. SEPARATE 'SITE-SPECIFIC' SEALED ENGINEERING IS REQUIRED IN ORDER TO DEVIATE FROM LOADS OR CONFIGURATIONS CONTAINED HEREIN. CONTACT THIS ENGINEER OR A LICENSED PROFESSIONAL FOR ALTERNATE CONFIGURATION CALCULATIONS AS MAY BE REQUIRED. 12.THE CONTRACTOR SHALL CAREFULLY CONSIDER POSSIBLE IMPOSING LOADS ON ROOF, INCLUDING BUT NOT LIMITED TO ANY CONCENTRATED LOADS WHICH MAY JUSTIFY GREATER DESIGN CRITERIA. ADDITIONAL ROOF LOAD CRITERIA SHALL BE PROPERLY ANALYZED BY A PROFESSIONAL ENGINEER. RESULTS ARE WIND ONLY. 13.EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. 14.ALTERATIONS, ADDITIONS OR OTHER MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. DESIGN LOAD COMBINATION CONDITIONS PRESSURES PROVIDED IN THE TABLES HEREIN ARE ALLOWABLE STRESS DESIGN FACTORED LOAD COMBINATIONS PER ASCE 7-16 CHAPTER 2.4 & CORRESPONDING WIND PRESSURE DESIGN CHAPTERS. THE WIND PRESSURES UTILIZED IN THESE CALCULATIONS ASSUME A CANOPY OF HEIGHT = 12FT AND AN AREA OF 100 SQFT. ASD LOAD COMBINATIONS HEREIN ASSUME A CONSTANT DEAD LOAD OF 2 PSF, ROOF LIVE LOAD, LR = 20 PSF, SNOW LOAD, S = 20 PSF, AND WIND LOAD, W AS CALCULATED FOR THE SELECTED STRUCTURE & SITE SPECIFIC CONDITIONS. PRESSURES LISTED ARE VALID FOR DESIGN CONDITIONS EQUAL TO OR LESS THAN THE LOAD COMBINATION CONSIDERED. FOR LOADING CONDITIONS EXCEEDING THE CONSTANTS STATED ABOVE (SUCH AS A ROOF OR SNOW LOADING EXCEEDING 20 PSF, OR THE CONSIDERATION OF SEISMIC LOADING), USE THE ONLINE LOAD COMBINATION TOOLS FOUND AT THE QR CODE PROVIDED. INSTRUCTIONS FOR TABLE USE: 1.IDENTIFY THE LOCAL VULT WIND VELOCITY BASED ON 3 SECOND GUST FACTOR FROM BUILDING DEPT OR PUBLISHED DATA. REFERENCED STANDARD WIND INFORMATION CAN BE FOUND AT HAZARDS.ATCOUNCIL.ORG AND AT THE QR CODE BELOW 2.CONFIRM THAT THE SITE-SPECIFIC & LOCAL MUNICIPALITY DESIGN CONDITIONS ARE WITHIN THE LIMITATIONS OF THIS MASTER PLAN AS STATED ABOVE. CONFIRM THAT THESE CONDITIONS ALSO COMPLY WITH LOCAL CODE REQUIREMENTS 3.IDENTIFY THAT THE STRUCTURE TO BE USED CONFORMS TO THE LIMITATIONS NOTED HEREIN. THIS DOCUMENT PROVIDES INFORMATION FOR OPEN-WALLED STRUCTURES THAT ARE EITHER FREESTANDING OR HOST-ATTACHED, AND HAVE A ROOF THAT IS AT LEAST 50% POROUS. 4.READ OFF POSITIVE (DOWNWARD), NEGATIVE (UPLIFT), AND LATERAL PRESSURES AS ASD DESIGN LOAD COMBINATIONS FOR DIRECT USE WITH CORRESPONDING PRESSURE-DESIGNED SYSTEMS ADDITIONAL ENGINEERING IS REQUIRED FOR DESIGN CONDITIONS THAT EXCEED THE CONSIDERATIONS OF THIS MASTER PLAN. CALCULATION NOTES: 1.INTERPOLATION OF THESE RESULTS ARE NOT PERMITTED WITHOUT SIGNED AND SEALED RESULTS. 2.PRESSURES HEREIN ARE VALID FOR CONDITIONS EQUAL OR LESS THAN THE DESIGN CONDITIONS LISTED. FOR CONDITIONS EXCEEDING THOSE LISTED, VISIT ECALC.IO/WIND TO CALCULATE A SITE SPECIFIC PRESSURE 3.TABLES USE ASCE ZONE 2 PRESSURES FOR A ROOF $5($ )7ð$1'&$123<+(,*+7+C = 12FT, C&C METHOD, FLAT TERRAIN. FOR MORE EXACT ANSWERS USE THE MATCHING ONLINE CALCULATOR AT ECALC.IO/WIND. DESIGN WIND PRESSURE (PSF) 110 MPH 120 MPH 130 MPH 140 MPH 150 MPH 160 MPH B 23 C -10 B -10 C B C B C B C B C OPEN-FREESTANDING PERGOLA FOR TABLE 2 NOTE: ROOF DESIGN LOADS SHOWN HEREIN INCLUDE A 50% REDUCTION IN TOTAL WIND PRESSURE TO ACCOUNT FOR A POROUS ROOF SURFACE AREA EXPOSED TO WIND AND SNOW (SUCH AS A TRELLIS OR OPERABLE LOUVERED ROOF WHEN IN THE FULLY OPENED POSITION). TO UTILIZE THESE VALUES, ROOF STRUCTURE SHOULD BE CLEAR OF OBSTRUCTION, AND ANY LOUVERS SHALL BE FULLY OPENED BEFORE ANY NAMED STORM OR SIMILAR HIGH-WIND EVENT. IF NOT, THE DESIGN PRESSURES SHOWN ABOVE SHALL BE DOUBLED BEFORE INSTALLATION & USE.VISIT ECALC.IO/WIND TO ORDER ENGINEER-CERTIFIED ORIGINALS FOR PERMIT USE OUR ONLINE CALCULATIONS WITH BETTER ANSWERS HELPFUL EXPLANATIONS & MORE WIND RESOURCES TABLE 3 - ATTACHED CANOPY: TABLE 1: LATERAL PRESSURES TABLE 2: ROOF PRESSURES (WIND PRESSURE AGAINST SIDE OF FREESTANDING OR HOST ATTACHED STRUCTURES WITH OPEN WALLS) (WIND, AND LISTED GRAVITY LOADING AGAINST ROOF OF FREESTANDING STRUCTURE (+ = GRAVITY; - = UPLIFT) B C B C B C B C B C B C B C B C B C B C B C B C -10 -10 -10 -10 -10 -10 -10 -10 -10 -10 -10 -10 -10 -10 -10 -10 -10 -11 -10 -13 -10 -14 23 23 23 23 23 23 23 23 24 23 25 23 23 23 23 23 23 23 23 23 24 23 25 Š Š Š Š Š Š ŠŠ VALID FOR 1 PERMIT ONLY U.N.O. RE M A R K S DR W N CH K D DA T E SCALE: COPYRIGHT ENGINEERING EXPRESSŠ C: \ U s e r s \ c o l b y \ E n g i n e e r i n g E x p r e s s \ P r o d u c t i o n - D o c u m e n t s \ P r o j e c t s \ 2 1 - 4 0 4 6 0 P I V O T 6 X L M A S T E R P L A N S H E E T \ W o r k \ D r a w i n g s & C A D \ 2 1 - 4 0 4 6 0 d P I V O T 6 X L M P S . d w g 07 / 2 3 / 2 0 2 1 - 4 : 1 6 p m co l b y IN I T I S S U E CC B AE M 7/ 2 3 / 2 1 - - - - - - - - - - - - - - - - PHOTOCOPIES NOT TO BE USED OR SCAN THIS CODE ABBREVIATIONS: ɽс^>KW͕'Z^ (+) = POSITIVE (DOWNW-IN) PRESSURE (-) = NEGATIVE (UP-OUT) PRESSURE Hc = CANOPY HEIGHT He = EAVE HEIGHT PSF = POUNDS PER SQUARE FOOT (ASD) MPH = MILES PER HOUR (Vult) HOST ATTACHED CANOPY/PATIO COVER ISOMETRIC (TABLE 3-ROOF, OPEN WALL) MAIN RESIDENCE FLAT OR LOW ROOF SLOPE He Hc FOR TABLE 3 WIND SPEED TO PRESSURE LOAD COMBINATION CONVERSION TABLES FOR CANOPIES & PERGOLAS WITH 50% ROOF POROSITY ASD DESIGN LOAD COMBINATION PRESSURES CONSIDER DL= 3 PSF, LR = 20 PSF, S = 20 PSF, AND WIND LOAD, W AS CALCULATED FOR THE SELECTED STRUCTURE USING ASCE 7-16 Vult WIND SPEED & ASD PRESSURE METHOD & CALCULATED AT MEAN SEA LEVEL FOR OPEN-WALLED CANOPY STRUCTURES WITH AT LEAST 50% ROOF POROSITY DESIGN NOTES 1.PRESSURES HEREIN ARE CALCULATED IN CONFORMANCE WITH (ASD) "ALLOWABLE STRESS DESIGN METHODOLOGY" PER IBC (2018) / FBC (2020) SECTION 1605 & ASCE 7-16 SECTION 2.4.1, WITH WIND PRESSURES PER ASCE CHAPTER 30, AND LOADING CONDITIONS USING THE CODES & CRITERIA AS OUTLINED. 2.'WORST CASE' CRITICAL CONDITIONS SHALL BE ASSUMED FOR SAFE PRESSURE RATINGS. 3.TOPOGRAPHIC FACTOR Kzt=1.0 FOR FLAT TERRAIN USE ONLY. NO HILLS SHALL BE NEARBY AREA. 4.VERIFY USE OF Kd (DIRECTIONALITY FACTOR) WITH LOCAL BUILDING DEPARTMENT, Kd=0.85 USED HEREIN. PRESSURES SHALL BE ADJUSTED AS REQUIRED BY USE OF ALTERNATE Kd VALUES. GENERAL NOTES 5.THIS DOCUMENT IS NOT A SITE-SPECIFIC DOCUMENT & DOES NOT PERTAIN TO ANY SPECIFIC RESIDENCE. 6.THIS DOCUMENT IS ONLY VALID WITH AN ORIGINAL SIGNATURE & RAISED SEAL OR DIGITALLY SEALED. 7.THIS DOCUMENT ILLUSTRATES ALLOWABLE DESIGN WIND PRESSURES (ASD) AS LISTED. APPLICATION OF THESE TABLES AND CORRESPONDING WIND VELOCITY (SPEED), EXPOSURE, & OTHER COEFFICIENTS LISTED HEREIN SHALL BE DICTATED AND VERIFIED BY THE GOVERNING BUILDING DEPARTMENT AND PERMIT HOLDER. 8.NO WARRANTY FOR APPLICABILITY OF THE USE OF THESE TABLES IS OFFERED HEREIN. 9.THIS SPECIFICATION DOES NOT OFFER ANY PRODUCT APPROVED CERTIFICATION. REFER TO ANY SEPARATELY SUBMITTED TEST CRITERIA AND OTHER APPROVALS FOR DESIGN & INSTALLATION INFORMATION AND APPLICABILITY OF THESE TABLE VALUES WHICH IS TO BE VERIFIED BY OTHERS IN ACCORDANCE WITH GOVERNING CODES. 10.CONTRACTOR SHALL INVESTIGATE AND CONFORM TO ALL LOCAL BUILDING CODE AMENDMENTS WHICH MAY APPLY. 11.IT IS RECOMMENDED THAT A LICENSED ENGINEER OR REGISTERED ARCHITECT PREPARE SITE SPECIFIC DOCUMENTS FOR USE IN CONJUNCTION WITH THIS DOCUMENT. SEPARATE 'SITE-SPECIFIC' SEALED ENGINEERING IS REQUIRED IN ORDER TO DEVIATE FROM LOADS OR CONFIGURATIONS CONTAINED HEREIN. CONTACT THIS ENGINEER OR A LICENSED PROFESSIONAL FOR ALTERNATE CONFIGURATION CALCULATIONS AS MAY BE REQUIRED. 12.THE CONTRACTOR SHALL CAREFULLY CONSIDER POSSIBLE IMPOSING LOADS ON ROOF, INCLUDING BUT NOT LIMITED TO ANY CONCENTRATED LOADS WHICH MAY JUSTIFY GREATER DESIGN CRITERIA. ADDITIONAL ROOF LOAD CRITERIA SHALL BE PROPERLY ANALYZED BY A PROFESSIONAL ENGINEER. RESULTS ARE WIND ONLY. 13.EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. 14.ALTERATIONS, ADDITIONS OR OTHER MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. DESIGN LOAD COMBINATION CONDITIONS PRESSURES PROVIDED IN THE TABLES HEREIN ARE ALLOWABLE STRESS DESIGN FACTORED LOAD COMBINATIONS PER ASCE 7-16 CHAPTER 2.4 & CORRESPONDING WIND PRESSURE DESIGN CHAPTERS. THE WIND PRESSURES UTILIZED IN THESE CALCULATIONS ASSUME A CANOPY OF HEIGHT = 12FT AND AN AREA OF 100 SQFT. ASD LOAD COMBINATIONS HEREIN ASSUME A CONSTANT DEAD LOAD OF 2 PSF, ROOF LIVE LOAD, LR = 20 PSF, SNOW LOAD, S = 20 PSF, AND WIND LOAD, W AS CALCULATED FOR THE SELECTED STRUCTURE & SITE SPECIFIC CONDITIONS. PRESSURES LISTED ARE VALID FOR DESIGN CONDITIONS EQUAL TO OR LESS THAN THE LOAD COMBINATION CONSIDERED. FOR LOADING CONDITIONS EXCEEDING THE CONSTANTS STATED ABOVE (SUCH AS A ROOF OR SNOW LOADING EXCEEDING 20 PSF, OR THE CONSIDERATION OF SEISMIC LOADING), USE THE ONLINE LOAD COMBINATION TOOLS FOUND AT THE QR CODE PROVIDED. INSTRUCTIONS FOR TABLE USE: 1.IDENTIFY THE LOCAL VULT WIND VELOCITY BASED ON 3 SECOND GUST FACTOR FROM BUILDING DEPT OR PUBLISHED DATA. REFERENCED STANDARD WIND INFORMATION CAN BE FOUND AT HAZARDS.ATCOUNCIL.ORG AND AT THE QR CODE BELOW 2.CONFIRM THAT THE SITE-SPECIFIC & LOCAL MUNICIPALITY DESIGN CONDITIONS ARE WITHIN THE LIMITATIONS OF THIS MASTER PLAN AS STATED ABOVE. CONFIRM THAT THESE CONDITIONS ALSO COMPLY WITH LOCAL CODE REQUIREMENTS 3.IDENTIFY THAT THE STRUCTURE TO BE USED CONFORMS TO THE LIMITATIONS NOTED HEREIN. THIS DOCUMENT PROVIDES INFORMATION FOR OPEN-WALLED STRUCTURES THAT ARE EITHER FREESTANDING OR HOST-ATTACHED, AND HAVE A ROOF THAT IS AT LEAST 50% POROUS. 4.READ OFF POSITIVE (DOWNWARD), NEGATIVE (UPLIFT), AND LATERAL PRESSURES AS ASD DESIGN LOAD COMBINATIONS FOR DIRECT USE WITH CORRESPONDING PRESSURE-DESIGNED SYSTEMS ADDITIONAL ENGINEERING IS REQUIRED FOR DESIGN CONDITIONS THAT EXCEED THE CONSIDERATIONS OF THIS MASTER PLAN. CALCULATION NOTES: 1.INTERPOLATION OF THESE RESULTS ARE NOT PERMITTED WITHOUT SIGNED AND SEALED RESULTS. 2.PRESSURES HEREIN ARE VALID FOR CONDITIONS EQUAL OR LESS THAN THE DESIGN CONDITIONS LISTED. FOR CONDITIONS EXCEEDING THOSE LISTED, VISIT ECALC.IO/WIND TO CALCULATE A SITE SPECIFIC PRESSURE 3.TABLES USE ASCE ZONE 2 PRESSURES FOR A ROOF $5($ )7ð$1'&$123<+(,*+7+C = 12FT, C&C METHOD, FLAT TERRAIN. FOR MORE EXACT ANSWERS USE THE MATCHING ONLINE CALCULATOR AT ECALC.IO/WIND. DESIGN ROOF PRESSURES FOR HOST ATTACHED CANOPY ULTIMATE WIND SPEED ASCE EXPOSURE CATEGORY CANOPY ATTACHED 1FT OR MORE BELOW EAVE (hc/he)<0.9) CANOPY ATTACHED 1FT OR LESS BELOW EAVE ;Ϭ͘ϵч;ŚĐͬŚĞͿчϭͿ DESIGN WIND PRESSURE (PSF) 110 MPH 120 MPH 130 MPH 140 MPH 150 MPH 160 MPH B 23 C -10 B -10 C B C B C B C B C OPEN-FREESTANDING PERGOLA MONOSLOPE ROOF ONLY WITH 50% POROSITY (MIN) (SUCH AS TRELLIS OR LOUVERED ROOF) FOR TABLE 2 NOTE: ROOF DESIGN LOADS SHOWN HEREIN INCLUDE A 50% REDUCTION IN TOTAL WIND PRESSURE TO ACCOUNT FOR A POROUS ROOF SURFACE AREA EXPOSED TO WIND AND SNOW (SUCH AS A TRELLIS OR OPERABLE LOUVERED ROOF WHEN IN THE FULLY OPENED POSITION). TO UTILIZE THESE VALUES, ROOF STRUCTURE SHOULD BE CLEAR OF OBSTRUCTION, AND ANY LOUVERS SHALL BE FULLY OPENED BEFORE ANY NAMED STORM OR SIMILAR HIGH-WIND EVENT. IF NOT, THE DESIGN PRESSURES SHOWN ABOVE SHALL BE DOUBLED BEFORE INSTALLATION & USE. ULT WIND SPEED (MPH) ASCE EXPOSURE CATEGORY ɽфϳ͘ϱΣ (+) (-) 110 MPH 24 -10 28 -10 120 MPH 25 -10 28 -10 130 MPH 26 -10 29 -11 140 MPH 27 -10 31 -14 150 MPH 28 -10 33 -16 160 MPH 30 -12 36 -20 MONOSLOPE (PSF) DESIGN ROOF PRESSURE WITH OPEN WALLS ULT WIND SPEED (MPH) ASCE EXPOSURE CATEGORY 110 MPH 30 36 120 MPH 14 17 130 MPH 17 20 140 MPH 20 24 150 MPH 23 27 160 MPH 26 31 LATERAL PRESSURE (PSF) DESIGN LATERAL PRESSURE VISIT ECALC.IO/WIND TO ORDER ENGINEER-CERTIFIED ORIGINALS FOR PERMIT USE OUR ONLINE CALCULATIONS WITH BETTER ANSWERS HELPFUL EXPLANATIONS & MORE WIND RESOURCES TABLE 3 - ATTACHED CANOPY: TABLE 1: LATERAL PRESSURES TABLE 2: ROOF PRESSURES (WIND PRESSURE AGAINST SIDE OF FREESTANDING OR HOST ATTACHED STRUCTURES WITH OPEN WALLS) (WIND, AND LISTED GRAVITY LOADING AGAINST ROOF OF FREESTANDING STRUCTURE (+ = GRAVITY; - = UPLIFT) B C B C B C B C B C B C B C B C B C B C B C B C -10 -10 -10 -10 -10 -10 -10 -10 -10 -10 -10 -10 -10 -10 -10 -10 -10 -11 -10 -13 -10 -14 23 23 23 23 23 23 23 23 24 23 25 23 23 23 23 23 23 23 23 23 24 23 25 Š Š Š Š Š Š ŠŠ VALID FOR 1 PERMIT ONLY U.N.O. RE M A R K S DR W N CH K D DA T E SCALE: COPYRIGHT ENGINEERING EXPRESSŠ C: \ U s e r s \ c o l b y \ E n g i n e e r i n g E x p r e s s \ P r o d u c t i o n - D o c u m e n t s \ P r o j e c t s \ 2 1 - 4 0 4 6 0 P I V O T 6 X L M A S T E R P L A N S H E E T \ W o r k \ D r a w i n g s & C A D \ 2 1 - 4 0 4 6 0 d P I V O T 6 X L M P S . d w g 07 / 2 3 / 2 0 2 1 - 4 : 1 6 p m co l b y IN I T I S S U E CC B AE M 7/ 2 3 / 2 1 - - - - - - - - - - - - - - - - PHOTOCOPIES NOT TO BE USED MAIN BEAM SPAN SCHEDULE NOTES: 1.A MAIN BEAM SHALL BE CONSIDERED AN INTERIOR BEAM IF THERE ARE ROOF PANS ON BOTH SIDES OF THE BEAM (BEYOND THE ALLOWED OVERHANG ON SHEET 8). OTHERWISE, THE BEAM IS CONSIDERED AN END BEAM. 2.DEFLECTION LIMIT OF L/80 USED FOR DETERMINATION OF ALLOWABLE BEAM SPANS PER THE INTERNATIONAL BUILDING CODE. 3.LARGER SPANS AND ALTERNATE CONFIGURATIONS ARE POSSIBLE AND MAY BE SUBSTITUTED FOR THE ABOVE WITH ADDITIONAL, CERTIFIED, SITE-SPECIFIC ENGINEERING. MAIN BEAM SPAN SCHEDULE (END BEAM)MAIN BEAM SPAN SCHEDULE (INTERIOR BEAM) BEAM TYPE ROOF PAN SPAN 8 FT 10 FT 12 FT 14 FT FACTORED ASD LOAD COMBO PRESSURE (PSF) ALLOWABLE BEAM SPAN (FT-IN) BEAM TYPE ROOF PAN SPAN 8 FT 10 FT 12 FT 14 FT FACTORED ASD LOAD COMBO PRESSURE (PSF) ALLOWABLE BEAM SPAN (FT-IN) SINGLE 2" X 10" 20 20' - 0"20' - 0"20' - 0"20' - 0" 25 20' - 0"20' - 0"20' - 0"19' - 0" 30 20' - 0"20' - 0"18' - 8"17' - 3" 35 20' - 0"18' - 10"17' - 3"N/A 40 19' - 8"17' - 8"16' - 2"N/A 45 18' - 7"16' - 8"N/A N/A 50 17' - 7"15' - 9"N/A N/A 55 16' - 10"15' - 1"N/A N/A 60 16' - 1"N/A N/A N/A DOUBLE 2" X 10" 20 24' - 0"24' - 0"24' - 0"24' - 0" 25 24' - 0"24' - 0"24' - 0"24' - 0" 30 24' - 0"24' - 0"24' - 0"24' - 0" 35 24' - 0"24' - 0"24' - 0"N/A 40 24' - 0"24' - 0"22' - 10"N/A 45 24' - 0"23' - 7"N/A N/A 50 24' - 0"22' - 5"N/A N/A 55 23' - 10"21' - 4"N/A N/A 60 22' - 9"N/A N/A N/A SINGLE 2" X 10" 20 20' - 0"17' - 9"16' - 3"15' - 0" 25 17' - 9"15' - 11"14' - 6"13' - 5" 30 16' - 3"14' - 6"13' - 3"12' - 3" 35 15' - 0"13' - 5"12' - 3"N/A 40 14' - 0"12' - 6"11' - 5"N/A 45 13' - 3"11' - 9"N/A N/A 50 12' - 6"11' - 2"N/A N/A 55 11' - 11"10' - 7"N/A N/A 60 11' - 5"N/A N/A N/A DOUBLE 2" X 10" 20 24' - 0"24' - 0"22' - 2"20' - 6" 25 24' - 0"21' - 9"20' - 2"18' - 7" 30 22' - 2"20' - 0"18' - 5"17' - 2" 35 20' - 8"18' - 6"17' - 2"N/A 40 19' - 5"17' - 6"16' - 1"N/A 45 18' - 5"16' - 7"N/A N/A 50 17' - 6"15' - 10"N/A N/A 55 16' - 9"15' - 1"N/A N/A 60 16' - 2"N/A N/A N/A 1/8" 10" 2" N.T.S. 2" X 10" BEAM 6063-T6 ALUM LOUVER SPAN SCHEDULE LOUVER SPAN SCHEDULE NOTES: 1.DEFLECTION REQUIREMENT SHALL BE DETERMINED BASED ON THE INTERNATIONAL BUILDING CODE ALONG WITH ANY LOCAL JURISDICTION REQUIREMENTS. 2.LARGER SPANS AND ALTERNATE CONFIGURATIONS ARE POSSIBLE AND MAY BE SUBSTITUTED FOR THE ABOVE WITH ADDITIONAL, CERTIFIED, SITE-SPECIFIC ENGINEERING. DESIGN PRESSURE ALLOWABLE LOUVER SPAN (FT-IN) L/180 DEFLECTION CRITERIA 20 PSF 12' - 0" 30 PSF 12' - 0" 40 PSF 11' - 1" 50 PSF 10' - 4" 60 PSF 9' - 4" L/80 DEFLECTION CRITERIA 12' - 0" 12' - 0" 12' - 0" 12' - 0" 11' - 0" 25 PSF 35 PSF 45 PSF 55 PSF 12' - 0" 12' - 0" 12' - 0" 11' - 6"10' - 0" 10' - 8" 11' - 8" 12' - 0" 6" TYP. 6" TYP. N.T.S. LOUVER SECTION DETAIL Š Š Š Š Š Š ŠŠ VALID FOR 1 PERMIT ONLY U.N.O. RE M A R K S DR W N CH K D DA T E SCALE: COPYRIGHT ENGINEERING EXPRESSŠ C: \ U s e r s \ c o l b y \ E n g i n e e r i n g E x p r e s s \ P r o d u c t i o n - D o c u m e n t s \ P r o j e c t s \ 2 1 - 4 0 4 6 0 P I V O T 6 X L M A S T E R P L A N S H E E T \ W o r k \ D r a w i n g s & C A D \ 2 1 - 4 0 4 6 0 d P I V O T 6 X L M P S . d w g 07 / 2 3 / 2 0 2 1 - 4 : 1 6 p m co l b y IN I T I S S U E CC B AE M 7/ 2 3 / 2 1 - - - - - - - - - - - - - - - - PHOTOCOPIES NOT TO BE USED MAIN BEAM SPAN SCHEDULE NOTES: 1.A MAIN BEAM SHALL BE CONSIDERED AN INTERIOR BEAM IF THERE ARE ROOF PANS ON BOTH SIDES OF THE BEAM (BEYOND THE ALLOWED OVERHANG ON SHEET 8). OTHERWISE, THE BEAM IS CONSIDERED AN END BEAM. 2.DEFLECTION LIMIT OF L/80 USED FOR DETERMINATION OF ALLOWABLE BEAM SPANS PER THE INTERNATIONAL BUILDING CODE. 3.LARGER SPANS AND ALTERNATE CONFIGURATIONS ARE POSSIBLE AND MAY BE SUBSTITUTED FOR THE ABOVE WITH ADDITIONAL, CERTIFIED, SITE-SPECIFIC ENGINEERING. MAIN BEAM SPAN SCHEDULE (END BEAM)MAIN BEAM SPAN SCHEDULE (INTERIOR BEAM) BEAM TYPE ROOF PAN SPAN 8 FT 10 FT 12 FT 14 FT FACTORED ASD LOAD COMBO PRESSURE (PSF) ALLOWABLE BEAM SPAN (FT-IN) BEAM TYPE ROOF PAN SPAN 8 FT 10 FT 12 FT 14 FT FACTORED ASD LOAD COMBO PRESSURE (PSF) ALLOWABLE BEAM SPAN (FT-IN) SINGLE 2" X 10" 20 20' - 0"20' - 0"20' - 0"20' - 0" 25 20' - 0"20' - 0"20' - 0"19' - 0" 30 20' - 0"20' - 0"18' - 8"17' - 3" 35 20' - 0"18' - 10"17' - 3"N/A 40 19' - 8"17' - 8"16' - 2"N/A 45 18' - 7"16' - 8"N/A N/A 50 17' - 7"15' - 9"N/A N/A 55 16' - 10"15' - 1"N/A N/A 60 16' - 1"N/A N/A N/A DOUBLE 2" X 10" 20 24' - 0"24' - 0"24' - 0"24' - 0" 25 24' - 0"24' - 0"24' - 0"24' - 0" 30 24' - 0"24' - 0"24' - 0"24' - 0" 35 24' - 0"24' - 0"24' - 0"N/A 40 24' - 0"24' - 0"22' - 10"N/A 45 24' - 0"23' - 7"N/A N/A 50 24' - 0"22' - 5"N/A N/A 55 23' - 10"21' - 4"N/A N/A 60 22' - 9"N/A N/A N/A SINGLE 2" X 10" 20 20' - 0"17' - 9"16' - 3"15' - 0" 25 17' - 9"15' - 11"14' - 6"13' - 5" 30 16' - 3"14' - 6"13' - 3"12' - 3" 35 15' - 0"13' - 5"12' - 3"N/A 40 14' - 0"12' - 6"11' - 5"N/A 45 13' - 3"11' - 9"N/A N/A 50 12' - 6"11' - 2"N/A N/A 55 11' - 11"10' - 7"N/A N/A 60 11' - 5"N/A N/A N/A DOUBLE 2" X 10" 20 24' - 0"24' - 0"22' - 2"20' - 6" 25 24' - 0"21' - 9"20' - 2"18' - 7" 30 22' - 2"20' - 0"18' - 5"17' - 2" 35 20' - 8"18' - 6"17' - 2"N/A 40 19' - 5"17' - 6"16' - 1"N/A 45 18' - 5"16' - 7"N/A N/A 50 17' - 6"15' - 10"N/A N/A 55 16' - 9"15' - 1"N/A N/A 60 16' - 2"N/A N/A N/A 1/8" 10" 2" N.T.S. 2" X 10" BEAM 6063-T6 ALUM LOUVER SPAN SCHEDULE LOUVER SPAN SCHEDULE NOTES: 1.DEFLECTION REQUIREMENT SHALL BE DETERMINED BASED ON THE INTERNATIONAL BUILDING CODE ALONG WITH ANY LOCAL JURISDICTION REQUIREMENTS. 2.LARGER SPANS AND ALTERNATE CONFIGURATIONS ARE POSSIBLE AND MAY BE SUBSTITUTED FOR THE ABOVE WITH ADDITIONAL, CERTIFIED, SITE-SPECIFIC ENGINEERING. DESIGN PRESSURE ALLOWABLE LOUVER SPAN (FT-IN) L/180 DEFLECTION CRITERIA 20 PSF 12' - 0" 30 PSF 12' - 0" 40 PSF 11' - 1" 50 PSF 10' - 4" 60 PSF 9' - 4" L/80 DEFLECTION CRITERIA 12' - 0" 12' - 0" 12' - 0" 12' - 0" 11' - 0" 25 PSF 35 PSF 45 PSF 55 PSF 12' - 0" 12' - 0" 12' - 0" 11' - 6"10' - 0" 10' - 8" 11' - 8" 12' - 0" 6" TYP. 6" TYP. N.T.S. LOUVER SECTION DETAIL Š Š Š Š Š Š ŠŠ VALID FOR 1 PERMIT ONLY U.N.O. RE M A R K S DR W N CH K D DA T E SCALE: COPYRIGHT ENGINEERING EXPRESSŠ C: \ U s e r s \ c o l b y \ E n g i n e e r i n g E x p r e s s \ P r o d u c t i o n - D o c u m e n t s \ P r o j e c t s \ 2 1 - 4 0 4 6 0 P I V O T 6 X L M A S T E R P L A N S H E E T \ W o r k \ D r a w i n g s & C A D \ 2 1 - 4 0 4 6 0 d P I V O T 6 X L M P S . d w g 07 / 2 3 / 2 0 2 1 - 4 : 1 6 p m co l b y IN I T I S S U E CC B AE M 7/ 2 3 / 2 1 - - - - - - - - - - - - - - - - L = 1 / 2 R O O F P A N S P A N + PA N O V E R H A N G CORNER POST SUPPORT AREA = W X L W = 1/2 BEAM SPAN + BEAM OVERHANG CORNER POST L = R O O F P A N S P A N INTERNAL POST SUPPORT AREA = W X L W = BEAM SPAN INTERNAL POST EDGE POST SUPPORT AREA = W X L W = 1/2 BEAM SPAN + BEAM OVERHANG EDGE POST LOUVER OVERHANG 3' - 0" MAX BEAM OVERHANG 3'-0" MAX (SINGLE BEAM) 4'-0" MAX (DOUBLE BEAM) POST SUPPORT AREA CALCULATION NOT TO SCALE PLAN ALL ROOF PANS NOT SHOWN FOR CLARITY NOTE: POST SUPPORT AREA MAY BE CALCULATED SEPARATELY FOR EACH POST. EACH POST MAY UTILIZE DIFFERENT POST AND FOOTER SELECTIONS FROM THE TABLES HEREIN BASED ON THE SITE DESIGN CONDITIONS & ITS SUPPORT AREA APPLICABLE FOR HOST ATTACHED OR FREESTANDING COLUMN NAME AREA SUPPORTED BY COLUMN (SQ. FT) MAX LATERAL WIND PRESSURE (PSF) 10 PSF 20 PSF 30 PSF 40 PSF 50 PSF ALLOWABLE COLUMN HEIGHT (FT-IN): 6 x 6 x 1/8 (6063-T6) )7ð 14' - 0"14' - 0"12' - 6"10' - 6"N/A )7ð 14' - 0''14' - 0''12' - 0"10' - 0"N/A )7ð 14' - 0''12' - 6"10' - 0"N/A N/A )7ð 14' - 0''10' - 0"N/A N/A N/A )7ð 13' - 0"10' - 0"N/A N/A N/A )7ð 13' - 0"10' - 0"N/A N/A N/A )7ð 12' - 0"N/A N/A N/A N/A )7ð 11' - 0"N/A N/A N/A N/A 8 x 8 x 3/16 (6063-T6) )7ð 14' - 0"14' - 0"14' - 0"14' - 0"14' - 0" )7ð 14' - 0"14' - 0"14' - 0"14' - 0"14' - 0" )7ð 14' - 0"14' - 0"14' - 0"14' - 0"14' - 0" )7ð 14' - 0"14' - 0"14' - 0"14' - 0"14' - 0" )7ð 14' - 0"14' - 0"14' - 0"14' - 0"14' - 0" )7ð 14' - 0"14' - 0"14' - 0"14' - 0"12' - 0" )7ð 14' - 0"14' - 0"14' - 0"14' - 0"12' - 0" )7ð 14' - 0"14' - 0"14' - 0"13' - 6"11' - 6" ALLOWABLE POST HEIGHT SCHEDULE Š Š Š Š Š Š ŠŠ VALID FOR 1 PERMIT ONLY U.N.O. RE M A R K S DR W N CH K D DA T E SCALE: COPYRIGHT ENGINEERING EXPRESSŠ C: \ U s e r s \ c o l b y \ E n g i n e e r i n g E x p r e s s \ P r o d u c t i o n - D o c u m e n t s \ P r o j e c t s \ 2 1 - 4 0 4 6 0 P I V O T 6 X L M A S T E R P L A N S H E E T \ W o r k \ D r a w i n g s & C A D \ 2 1 - 4 0 4 6 0 d P I V O T 6 X L M P S . d w g 07 / 2 3 / 2 0 2 1 - 4 : 1 6 p m co l b y IN I T I S S U E CC B AE M 7/ 2 3 / 2 1 - - - - - - - - - - - - - - - - L = 1 / 2 R O O F P A N S P A N + PA N O V E R H A N G CORNER POST SUPPORT AREA = W X L W = 1/2 BEAM SPAN + BEAM OVERHANG CORNER POST L = R O O F P A N S P A N INTERNAL POST SUPPORT AREA = W X L W = BEAM SPAN INTERNAL POST EDGE POST SUPPORT AREA = W X L W = 1/2 BEAM SPAN + BEAM OVERHANG EDGE POST LOUVER OVERHANG 3' - 0" MAX BEAM OVERHANG 3'-0" MAX (SINGLE BEAM) 4'-0" MAX (DOUBLE BEAM) POST SUPPORT AREA CALCULATION NOT TO SCALE PLAN ALL ROOF PANS NOT SHOWN FOR CLARITY NOTE: POST SUPPORT AREA MAY BE CALCULATED SEPARATELY FOR EACH POST. EACH POST MAY UTILIZE DIFFERENT POST AND FOOTER SELECTIONS FROM THE TABLES HEREIN BASED ON THE SITE DESIGN CONDITIONS & ITS SUPPORT AREA APPLICABLE FOR HOST ATTACHED OR FREESTANDING COLUMN NAME AREA SUPPORTED BY COLUMN (SQ. FT) MAX LATERAL WIND PRESSURE (PSF) 10 PSF 20 PSF 30 PSF 40 PSF 50 PSF ALLOWABLE COLUMN HEIGHT (FT-IN): 6 x 6 x 1/8 (6063-T6) )7ð 14' - 0"14' - 0"12' - 6"10' - 6"N/A )7ð 14' - 0''14' - 0''12' - 0"10' - 0"N/A )7ð 14' - 0''12' - 6"10' - 0"N/A N/A )7ð 14' - 0''10' - 0"N/A N/A N/A )7ð 13' - 0"10' - 0"N/A N/A N/A )7ð 13' - 0"10' - 0"N/A N/A N/A )7ð 12' - 0"N/A N/A N/A N/A )7ð 11' - 0"N/A N/A N/A N/A 8 x 8 x 3/16 (6063-T6) )7ð 14' - 0"14' - 0"14' - 0"14' - 0"14' - 0" )7ð 14' - 0"14' - 0"14' - 0"14' - 0"14' - 0" )7ð 14' - 0"14' - 0"14' - 0"14' - 0"14' - 0" )7ð 14' - 0"14' - 0"14' - 0"14' - 0"14' - 0" )7ð 14' - 0"14' - 0"14' - 0"14' - 0"14' - 0" )7ð 14' - 0"14' - 0"14' - 0"14' - 0"12' - 0" )7ð 14' - 0"14' - 0"14' - 0"14' - 0"12' - 0" )7ð 14' - 0"14' - 0"14' - 0"13' - 6"11' - 6" ALLOWABLE POST HEIGHT SCHEDULE Š Š Š Š Š Š ŠŠ VALID FOR 1 PERMIT ONLY U.N.O. RE M A R K S DR W N CH K D DA T E SCALE: COPYRIGHT ENGINEERING EXPRESSŠ C: \ U s e r s \ c o l b y \ E n g i n e e r i n g E x p r e s s \ P r o d u c t i o n - D o c u m e n t s \ P r o j e c t s \ 2 1 - 4 0 4 6 0 P I V O T 6 X L M A S T E R P L A N S H E E T \ W o r k \ D r a w i n g s & C A D \ 2 1 - 4 0 4 6 0 d P I V O T 6 X L M P S . d w g 07 / 2 3 / 2 0 2 1 - 4 : 1 7 p m co l b y IN I T I S S U E CC B AE M 7/ 2 3 / 2 1 - - - - - - - - - - - - - - - - (4) ANCHORS W/ 5" SPACING (SEE ANCHOR SCHEDULE) SEE FOOTING SCHEDULE N.T.S. 6"X6" POST BRACKET DETAIL 157.500 33.750 90.000 33.750 16.875 61.875 61.875 16.875 15 7 . 5 0 0 33 . 7 5 0 90 . 0 0 0 33 . 7 5 0 16 . 8 7 5 61 . 8 7 5 61 . 8 7 5 16 . 8 7 5 (8) ANCHORS W/ 5.5" SPACING (SEE ANCHOR SCHEDULE) [8] 1/4" THICK GUSSETS 3/8" THICK ALUM. BASE FLANGE 1/4" TYP. 8" X 8" POST 8" X 8" POST N.T.S. 8"X8" WELDED FLANGE BASE DETAIL 6" X 6" POST 135.000 33.750 67.500 33.750 16.875 50.625 50.625 16.875 13 5 . 0 0 0 33 . 7 5 0 67 . 5 0 0 33 . 7 5 0 16 . 8 7 5 50 . 6 2 5 50 . 6 2 5 16 . 8 7 5 GUSSET BASE FLANGE 8X ‘ 0.563 THRU 6" X 6" POST (8) ANCHORS W/ 4.5" SPACING SEE ANCHOR SCHEDULE) [8] 1/4" THICK GUSSETS N.T.S. 3/8" THICK ALUM. BASE FLANGE FULL WELD 1/4" TYP. WELDED FLANGE BASE COVER BASE COVER N.T.S. 6"X6" WELDED FLANGE BASE DETAIL CONCRETE ANCHOR COLUMN NAME AREA SUPPORTED BY COLUMN (SQ. FT) MAX LATERAL WIND PRESSURE (PSF) 10 PSF 20 PSF 30 PSF 40 PSF 50 PSF ALLOWABLE COLUMN HEIGHT (FT-IN): 6 x 6 x 1/8 (6063-T6) )7ð (A) (1)(B) (1)(B) (1)(B) (2)N/A )7ð (B) (1)(B) (1)(B) (1)(B) (2)N/A )7ð (B) (1)(B) (1)(B) (2)N/A N/A )7ð (B) (1)(B) (1)N/A N/A N/A )7ð (B) (1)(B) (2)N/A N/A N/A )7ð (B) (1)(B) (2)N/A N/A N/A )7ð (B) (2)N/A N/A N/A N/A )7ð (B) (2)N/A N/A N/A N/A 8 x 8 x 3/16 (6063-T6) )7ð (A) (1)(A) (2)(B) (1)(B) (1)(B) (2) )7ð (A) (1)(A) (2)(B) (1)(B) (2)(B) (3) )7ð (A) (2)(B) (1)(B) (2)X X )7ð (A) (2)(B) (1)(B) (2)X X )7ð (B) (1)(B) (1)(B) (2)X X )7ð (B) (1)(B) (2)X X X )7ð (B) (1)(B) (3)X X X )7ð (B) (1)X X X X N.T.S. 8"X8" POST BRACKET DETAIL 6.0" 6. 0 " 1/8" 8.0" 8. 0 " 3/16" N.T.S. 6063-T6 ALUM BASEPLATE AND ANCHOR SCHEDULE NOTES: 1.8-BOLT FLANGE BASEPLATE MAY BE USED WHERE 4-BOLT POST BRACKET IS PERMITTED 2.ALL ANCHOR CONNECTIONS ARE TO MIN. 3000 PSI CONCRETE 3.SEE PG. 5 FOR CALCULATING AREA SUPPORTED BY COLUMNS 4.SEE TABLE 1-12 FOR LATERAL WIND PRESSURES 5. ADDITIONAL ENGINEERING IS REQUIRED FOR VALUES OUTSIDE OF THIS SCHEDULE LEGEND: (A): 4-BOLT POST BRACKET (B): 8-BOLT FLANGE BASEPLATE X: POST EMBEDMENT REQUIRED (SEE DETAIL 1/12)  $77$&+86,1*‘6632:(5678'6': EMBEDMENT AND 7 1/2" MINIMUM EDGE DISTANCE. (SPACING VARIES WITH COLUMN SIZE)  $77$&+86,1*‘6632:(5678'6': EMBEDMENT AND 9 1/2" MINIMUM EDGE DISTANCE. (SPACING VARIES WITH COLUMN SIZE)  $77$&+86,1*‘6632:(5678'6': EMBEDMENT AND 11" MINIMUM EDGE DISTANCE. (SPACING VARIES WITH COLUMN SIZE) BASEPLATE AND ANCHOR SCHEDULE 6" x 6" POST STAMPED ALUMINUM POST BRACKET W/2" LEGS (3) #14 TEK SCREWS EACH SIDE 8" x 8" POST 8" x 8" x 0.1875" STAMPED ALUMINUM POST BRACKET W/2" LEGS (4) #14 TEK SCREWS EACH SIDE SEE FOOTING SCHEDULE (4) ANCHORS W/ 5" SPACING (SEE ANCHOR SCHEDULE) CONCRETE ANCHOR GUSSET BASE FLANGE 8X ‘ 0.563 THRU FULL WELD BASE COVER WELDED FLANGE BASE COVER 8" SQ POST DETAIL N.T.S. 6063-T6 ALUM 6" SQ POST DETAIL Š Š Š Š Š Š ŠŠ VALID FOR 1 PERMIT ONLY U.N.O. RE M A R K S DR W N CH K D DA T E SCALE: COPYRIGHT ENGINEERING EXPRESSŠ C: \ U s e r s \ c o l b y \ E n g i n e e r i n g E x p r e s s \ P r o d u c t i o n - D o c u m e n t s \ P r o j e c t s \ 2 1 - 4 0 4 6 0 P I V O T 6 X L M A S T E R P L A N S H E E T \ W o r k \ D r a w i n g s & C A D \ 2 1 - 4 0 4 6 0 d P I V O T 6 X L M P S . d w g 07 / 2 3 / 2 0 2 1 - 4 : 1 7 p m co l b y IN I T I S S U E CC B AE M 7/ 2 3 / 2 1 - - - - - - - - - - - - - - - - PHOTOCOPIES NOT TO BE USED (4) ANCHORS W/ 5" SPACING (SEE ANCHOR SCHEDULE) SEE FOOTING SCHEDULE N.T.S. 6"X6" POST BRACKET DETAIL 157.500 33.750 90.000 33.750 16.875 61.875 61.875 16.875 15 7 . 5 0 0 33 . 7 5 0 90 . 0 0 0 33 . 7 5 0 16 . 8 7 5 61 . 8 7 5 61 . 8 7 5 16 . 8 7 5 (8) ANCHORS W/ 5.5" SPACING (SEE ANCHOR SCHEDULE) [8] 1/4" THICK GUSSETS 3/8" THICK ALUM. BASE FLANGE 1/4" TYP. 8" X 8" POST 8" X 8" POST N.T.S. 8"X8" WELDED FLANGE BASE DETAIL 6" X 6" POST 135.000 33.750 67.500 33.750 16.875 50.625 50.625 16.875 13 5 . 0 0 0 33 . 7 5 0 67 . 5 0 0 33 . 7 5 0 16 . 8 7 5 50 . 6 2 5 50 . 6 2 5 16 . 8 7 5 GUSSET BASE FLANGE 8X ‘ 0.563 THRU 6" X 6" POST (8) ANCHORS W/ 4.5" SPACING SEE ANCHOR SCHEDULE) [8] 1/4" THICK GUSSETS N.T.S. 3/8" THICK ALUM. BASE FLANGE FULL WELD 1/4" TYP. WELDED FLANGE BASE COVER BASE COVER N.T.S. 6"X6" WELDED FLANGE BASE DETAIL CONCRETE ANCHOR COLUMN NAME AREA SUPPORTED BY COLUMN (SQ. FT) MAX LATERAL WIND PRESSURE (PSF) 10 PSF 20 PSF 30 PSF 40 PSF 50 PSF ALLOWABLE COLUMN HEIGHT (FT-IN): 6 x 6 x 1/8 (6063-T6) )7ð (A) (1)(B) (1)(B) (1)(B) (2)N/A )7ð (B) (1)(B) (1)(B) (1)(B) (2)N/A )7ð (B) (1)(B) (1)(B) (2)N/A N/A )7ð (B) (1)(B) (1)N/A N/A N/A )7ð (B) (1)(B) (2)N/A N/A N/A )7ð (B) (1)(B) (2)N/A N/A N/A )7ð (B) (2)N/A N/A N/A N/A )7ð (B) (2)N/A N/A N/A N/A 8 x 8 x 3/16 (6063-T6) )7ð (A) (1)(A) (2)(B) (1)(B) (1)(B) (2) )7ð (A) (1)(A) (2)(B) (1)(B) (2)(B) (3) )7ð (A) (2)(B) (1)(B) (2)X X )7ð (A) (2)(B) (1)(B) (2)X X )7ð (B) (1)(B) (1)(B) (2)X X )7ð (B) (1)(B) (2)X X X )7ð (B) (1)(B) (3)X X X )7ð (B) (1)X X X X N.T.S. 8"X8" POST BRACKET DETAIL 6.0" 6. 0 " 1/8" 8.0" 8. 0 " 3/16" N.T.S. 6063-T6 ALUM BASEPLATE AND ANCHOR SCHEDULE NOTES: 1.8-BOLT FLANGE BASEPLATE MAY BE USED WHERE 4-BOLT POST BRACKET IS PERMITTED 2.ALL ANCHOR CONNECTIONS ARE TO MIN. 3000 PSI CONCRETE 3.SEE PG. 5 FOR CALCULATING AREA SUPPORTED BY COLUMNS 4.SEE TABLE 1-12 FOR LATERAL WIND PRESSURES 5. ADDITIONAL ENGINEERING IS REQUIRED FOR VALUES OUTSIDE OF THIS SCHEDULE LEGEND: (A): 4-BOLT POST BRACKET (B): 8-BOLT FLANGE BASEPLATE X: POST EMBEDMENT REQUIRED (SEE DETAIL 1/12)  $77$&+86,1*‘6632:(5678'6': EMBEDMENT AND 7 1/2" MINIMUM EDGE DISTANCE. (SPACING VARIES WITH COLUMN SIZE)  $77$&+86,1*‘6632:(5678'6': EMBEDMENT AND 9 1/2" MINIMUM EDGE DISTANCE. (SPACING VARIES WITH COLUMN SIZE)  $77$&+86,1*‘6632:(5678'6': EMBEDMENT AND 11" MINIMUM EDGE DISTANCE. (SPACING VARIES WITH COLUMN SIZE) BASEPLATE AND ANCHOR SCHEDULE 6" x 6" POST STAMPED ALUMINUM POST BRACKET W/2" LEGS (3) #14 TEK SCREWS EACH SIDE 8" x 8" POST 8" x 8" x 0.1875" STAMPED ALUMINUM POST BRACKET W/2" LEGS (4) #14 TEK SCREWS EACH SIDE SEE FOOTING SCHEDULE (4) ANCHORS W/ 5" SPACING (SEE ANCHOR SCHEDULE) CONCRETE ANCHOR GUSSET BASE FLANGE 8X ‘ 0.563 THRU FULL WELD BASE COVER WELDED FLANGE BASE COVER 8" SQ POST DETAIL N.T.S. 6063-T6 ALUM 6" SQ POST DETAIL SIGNED: 04/11/2023 Š Š Š Š Š Š ŠŠ VALID FOR 1 PERMIT ONLY U.N.O. RE M A R K S DR W N CH K D DA T E SCALE: COPYRIGHT ENGINEERING EXPRESSŠ C: \ U s e r s \ c o l b y \ E n g i n e e r i n g E x p r e s s \ P r o d u c t i o n - D o c u m e n t s \ P r o j e c t s \ 2 1 - 4 0 4 6 0 P I V O T 6 X L M A S T E R P L A N S H E E T \ W o r k \ D r a w i n g s & C A D \ 2 1 - 4 0 4 6 0 d P I V O T 6 X L M P S . d w g 07 / 2 3 / 2 0 2 1 - 4 : 1 7 p m co l b y IN I T I S S U E CC B AE M 7/ 2 3 / 2 1 - - - - - - - - - - - - - - - - 6" T Y P . DE P T H P E R DE S I G N S C H E D U L E 3KSI CONCRETE FOOTING PER FOOTING SCHEDULE. POST MAY BE EMBEDDED DIRECTLY INTO CONCRETE AS AN ALTERNATIVE TO SURFACE MOUNTING. PROVIDE 18" EMBEDMENT & A KEY HOLE FOR (1)#5 REBAR 12" LONG IN EACH DIRECTION, TYP. EMBEDDED POST, TYP WIDTH PER DESIGN SCHEDULE POST EMBED DETAIL NTS ELEVATION SEE FOOTING SCHEDULE ALUMINUM COLUMN & CONNECTION PER SEPARATE DETAIL. PLACE OVER MIDDLE 1 3 OF FOOTING CLOSEST TO CENTER SEE PAD FOOTING DIMENSIONS ABOVE PAVERS TO BE OVERLAID AFTER PLACEMENT OF POST (IF APPLICABLE) REINFORCING STEEL PER TABLE 12.2 VISIT ECALC.IO/FOOTING FOR ENGINEER-CERTIFIED ORIGINALS, HELPFUL TOOLS & RESOURCES & SITE-SPECIFIC ORDERING VISIT ENGINEERINGEXPRESS.COM/STORE FOR MORE MANUFACTURER MASTER PLANS TO USE WITH THIS DOCUMENT THIS DOCUMENT IS ONLY VALID WITH ORIGINAL ENGINEER CERTIFICATION FOOTING DETAILS: USE FOOTING PER # FOUND IN TABLE ABOVE #WIDTH LENGTH DEPTH VOLUME WEIGHT REINFORCEMENT 1 24''24''18''6.0 CUFT 900 LBS 2 #4 TOP & BOT EACH WAY - 2 30''30''18''9.4 CUFT 1406 LBS 4 - 3 30''30''24''12.5 CUFT 1875 LBS 4 & 5 #4 VERTICAL TIES 4 36''36''24''18.0 CUFT 2700 LBS 4 & 6 5 36''36''30''22.5 CUFT 3375 LBS 4 #5 TOP & BOT EACH WAY & 6 6 42''42''30''30.6 CUFT 4594 LBS 4 & 8 7 42''42''36''36.8 CUFT 5513 LBS 5 & 8 8 48''48''36''48.0 CUFT 7200 LBS 6 & 11 FOOTING TABLE NOTES: 1.F.S. AGAINST UPLIFT OF 33% HAS BEEN APPLIED TO ALL LOADS. 2.AT 2000PSF SOIL BEARING PRESSURE, GRAVITY DOES NOT GOVERN IN ANY CASE. ENSURE PROPER COMPACTION & EMBEDMENT FOR FROST & HEAVE REQUIREMENTS. 3.FOOTING WEIGHT CALCULATED PER 150 PCF STANDARD WEIGHT CONCRETE 4.FOOTINGS OF ALTERNATE SIZE & EQUAL OR GREATER VOLUME & WEIGHT ACCEPTABLE WITH SEPARATE FOOTING ENGINEERING 5.SITE SPECIFIC ENGINEERING REQUIRED FOR ANY VALUES, SIZES, CONCRETE TYPES, OR SOIL BEARING PRESSURES NOT COINCIDING WITH LIMITS OF THIS MASTER PLAN. TABLE 8.1 - FOOTING SELECTION TABLE 8.2 - FOOTING DETAILS FOOTER SCHEDULE NOTES: 1.FOOTERS SHALL BE 3000 PSI MINIMUM CONCRETE, BEARING ON SOIL WITH A MINIMUM BEARING CAPACITY OF 2000 PSF AS VERIFIED BY OTHERS. 2.IN LIEU OF THE FOOTERS DETAILED HEREIN, POSTS MAY BE ANCHORED TO EXISTING CONCRETE SLABS DESIGNED AND VERIFIED BY OTHERS TO SUPPORT THE CANOPY SYSTEM AS DETAILED HEREIN. 3.FOOTERS SHALL HAVE THE MINIMUM REINFORCEMENT INDICATED IN THE SCHEDULES HEREIN. 4.ALL REINFORCEMENT SHALL BE DEFORMED BARS OF INTERMEDIATE GRADE NEW BILLET STEEL CONFORMING TO CURRENT REQUIREMENTS OF ASTM A615, GRADE 60 (U.O.N.), FREE FROM OIL, LOOSE SCALE AND LOOSE RUST AND BENT, LAPPED, PLACED, SUPPORTED AND FASTENED ACCORDING TO THE "ACI DETAILING MANUAL" (SP-66) AND THE "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318). 5.MINIMUM REBAR COVER FOR CONCRETE FOOTINGS IS 3" FOR CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH AND 2" FOR CONCRETE EXPOSED TO EARTH OR WEATHER. 6.ALLOW 3 DAYS CURE TIME BEFORE INSTALLING ANCHORS INTO CONCRETE. 7.ALL CONCRETE WORK SHALL CONFORM TO ALL REQUIREMENTS AND RECOMMENDATIONS OF ACI 318 "SPECIFICATION FOR STRUCTURAL CONCRETE FOR BUILDINGS". A CERTIFICATE OF MANUFACTURER'S MIX AND STRENGTH IS TO BE PROVIDED TO THE INSPECTOR UPON REQUEST. NO WATER TO BE ADDED AFTER TRUCK LEAVES PLANT WITHOUT APPROVAL OF ENGINEER OR PLANT ENGINEER. PLANT CONTROL IS REQUIRED. MAXIMUM MIX TIME AT POINT OF DEPOSIT IS 90 MINUTES. 8.THESE TABLES REPRESENT EMPIRICAL UPLIFT CALCULATIONS FOR FOOTING SIZES BASED ON STANDARD WEIGHT (150PCF) CONCRETE. THEY NEGLECT THE BENEFIT OF SKIN FRICTION AND OTHER BENEFICIAL SURCHARGE LOADING. NO WARRANTY, EXPRESSED OR IMPLIED, IS CONTAINED HEREIN AS TO ANY INFORMATION OTHER THAN THAT WHICH IS PUBLISHED HEREIN. 9.ALL FOOTINGS ARE TO BE INSTALLED LOWER THAN CODE REQUIRED FROST LINE. GENERAL CONTRACTOR IS RESPONSIBLE FOR ADHERENCE TO LOCAL FROST LINE REQUIREMENTS. ADDITIONALLY, TOP OF FOOTINGS ARE TO BE 8" MINIMUM BELOW GRADE IN HVHZ (DADE & BROWARD COUNTIES, FL). 9 48''48''48''64.0 CUFT 9600 LBS 8 & 14 DESIGN UPLIFT PRESSURE (-) POST SUPPORT AREA 36 FT2 50 FT2 75 FT2 100 FT2 125 FT2 150 FT2 175 FT2 200 FT2 250 FT2 -10 PSF 1 1 2 3 3 4 4 5 6 -15 PSF 1 2 3 4 5 5 6 6 8 -20 PSF 2 3 4 5 6 6 7 8 9 -25 PSF 2 3 5 6 7 8 8 9 9 -30 PSF 3 4 5 6 8 8 9 9 N/A -35 PSF 4 4 6 7 8 9 9 N/A N/A -40 PSF 4 5 6 8 9 9 N/A N/A N/A -45 PSF 4 5 7 8 9 N/A N/A N/A N/A POST-BASE ATTACHMENT AND FOOTINGS L = 1 / 2 J O I S T S P A N + JO I S T O V E R H A N G CORNER POST SUPPORT AREA = W X L L = J O I S T S P A N W = BEAM SPAN EDGE POST SUPPORT AREA = W X L W = 1/2 BEAM SPAN + BEAM OVERHANG DECKING NOT SHOWN FOR CLARITY NOTE: POST SUPPORT AREA MAY BE CALCULATED SEPARATELY FOR EACH POST. EACH POST MAY UTILIZE DIFFERENT POST AND FOOTER SELECTIONS FROM THE TABLES HEREIN BASED ON THE SITE DESIGN CONDITIONS & ITS SUPPORT AREA APPLICABLE FOR HOST ATTACHED OR FREESTANDING POST SUPPORT AREA CALCULATION NTS ELEVATION TYP FOOTING INSTALLATION NTS ELEVATION CALL 811 BEFORE YOU DIG OR VISIT WWW.CALL811.COM INTERNAL POST SUPPORT AREA = W X L W = 1/2 BEAM SPAN + BEAM OVERHANG USE POST SUPPORT AREA (CALCULATED FOR POST SELECTION) TO DETERMINE FOOTING # TO DETERMINE SIZE & REINFORCEMENT REQUIRED FOR EACH POST 8.2 VALID ONLY FOR ZIP CODE: 81601 VALID ONLY FOR: CARBON CUSTOMS FOR PERMIT USE WITHIN 14 DAYS OF DIGITAL SEAL PE0053085 SIGNED: 04/11/2023 VALID ONLY FOR ZIP CODE: 81601 VALID ONLY FOR: CARBON CUSTOMS FOR PERMIT USE WITHIN 14 DAYS OF DIGITAL SEAL PE0053085 SIGNED: 04/11/2023 Š Š Š Š Š Š ŠŠ VALID FOR 1 PERMIT ONLY U.N.O. RE M A R K S DR W N CH K D DA T E SCALE: COPYRIGHT ENGINEERING EXPRESSŠ C: \ U s e r s \ c o l b y \ E n g i n e e r i n g E x p r e s s \ P r o d u c t i o n - D o c u m e n t s \ P r o j e c t s \ 2 1 - 4 0 4 6 0 P I V O T 6 X L M A S T E R P L A N S H E E T \ W o r k \ D r a w i n g s & C A D \ 2 1 - 4 0 4 6 0 d P I V O T 6 X L M P S . d w g 07 / 2 3 / 2 0 2 1 - 4 : 1 7 p m co l b y IN I T I S S U E CC B AE M 7/ 2 3 / 2 1 - - - - - - - - - - - - - - - - PHOTOCOPIES NOT TO BE USED 2" X 1 3/4" X 2" X 0.125" U-CHANNEL INSERT TO FIT SNUG, ATTACH CHANNEL TO BEAM W/ (4) #14 TEK SCREWS EQ SPACED ((5) SCREWS FOR 10" BEAM) (4) #14 TEK SCREWS EQ SPACED, BOTH SIDES OF BEAM INTERIOR BEAMPERIMETER BEAM 2"x8" BEAM INTERIOR CONNECTION DOUBLE 2" X 1 3/4" X 2" X 0.125" U-CHANNEL INSERT TO FIT SNUG, ATTACH EA CHANNEL TO BEAM W/ (4) #14 TEK SCREWS EQ SPACED ((5) SCREWS FOR 10" BEAM) (4) #14 TEK SCREWS EQ SPACED, BOTH SIDES OF BEAM PERIMETER BEAM INTERIOR BEAM [2] [4] #14 x 1" TEK SCREWS THRU POST INTO CHANNEL EA. SIDE 6" x 6" x 0.125" POST LOWER BEAM AND CHANNEL INTO POST 5 3/4" x 2" x 0.125 x 5 3/4" CHANNEL [4] #14 x 1" TEK SCREWS THRU POST INTO CHANNEL EA. SIDE 6" x 6" x 0.125" POST DOUBLE PERIMETER BEAM LOWER BEAM AND CHANNEL INTO POST [6] #14 x 1" TEK SCREWS THRU CHANNEL INTO EACH BEAM 5 3/4" x 2" x 0.125 x 5 3/4" CHANNEL N.T.S. SINGLE BEAM TO 6"X6" POST ISOMETRIC N.T.S. DOUBLE BEAM TO 6"X6" POST ISOMETRIC PERIMETER BEAM POST CHANNEL #14 TEK SCREWS BOTH SIDE #14 TEK SCREWS POST CHANNEL DOUBLE PERIMETER BEAM #14 TEK SCREWS BOTH SIDE #14 TEK SCREWS N.T.S.ISOMETRIC DOUBLE BEAM INTERIOR CONNECTION N.T.S.ISOMETRIC PERIMETER BEAM [6] #14 x 1" TEK SCREWS THRU CHANNEL INTO EACH BEAM USE APPROPRIATELY SIZED CONNECTION CHANNELS WITH SAME HARDWARE LISTED ABOVE FOR 8"X8" POST USE APPROPRIATELY SIZED CONNECTION CHANNELS WITH SAME HARDWARE LISTED ABOVE FOR 8"X8" POST INSERT / U CHANNEL BEAM 2" X 8" BEAM 2" X 8" BEAM 2" X 8" BEAM 2" X 8"COVER SHEET BEAM 2" X 8" GUTTER BEAM INSERT (8) #14 TEK SCREWS N.T.S. DOUBLE CHASE BEAM CONNECTION ISOMETRIC Š Š Š Š Š Š ŠŠ VALID FOR 1 PERMIT ONLY U.N.O. RE M A R K S DR W N CH K D DA T E SCALE: COPYRIGHT ENGINEERING EXPRESSŠ C: \ U s e r s \ c o l b y \ E n g i n e e r i n g E x p r e s s \ P r o d u c t i o n - D o c u m e n t s \ P r o j e c t s \ 2 1 - 4 0 4 6 0 P I V O T 6 X L M A S T E R P L A N S H E E T \ W o r k \ D r a w i n g s & C A D \ 2 1 - 4 0 4 6 0 d P I V O T 6 X L M P S . d w g 07 / 2 3 / 2 0 2 1 - 4 : 1 7 p m co l b y IN I T I S S U E CC B AE M 7/ 2 3 / 2 1 - - - - - - - - - - - - - - - - PHOTOCOPIES NOT TO BE USED 2" X 1 3/4" X 2" X 0.125" U-CHANNEL INSERT TO FIT SNUG, ATTACH CHANNEL TO BEAM W/ (4) #14 TEK SCREWS EQ SPACED ((5) SCREWS FOR 10" BEAM) (4) #14 TEK SCREWS EQ SPACED, BOTH SIDES OF BEAM INTERIOR BEAMPERIMETER BEAM 2"x8" BEAM INTERIOR CONNECTION DOUBLE 2" X 1 3/4" X 2" X 0.125" U-CHANNEL INSERT TO FIT SNUG, ATTACH EA CHANNEL TO BEAM W/ (4) #14 TEK SCREWS EQ SPACED ((5) SCREWS FOR 10" BEAM) (4) #14 TEK SCREWS EQ SPACED, BOTH SIDES OF BEAM PERIMETER BEAM INTERIOR BEAM [2] [4] #14 x 1" TEK SCREWS THRU POST INTO CHANNEL EA. SIDE 6" x 6" x 0.125" POST LOWER BEAM AND CHANNEL INTO POST 5 3/4" x 2" x 0.125 x 5 3/4" CHANNEL [4] #14 x 1" TEK SCREWS THRU POST INTO CHANNEL EA. SIDE 6" x 6" x 0.125" POST DOUBLE PERIMETER BEAM LOWER BEAM AND CHANNEL INTO POST [6] #14 x 1" TEK SCREWS THRU CHANNEL INTO EACH BEAM 5 3/4" x 2" x 0.125 x 5 3/4" CHANNEL N.T.S. SINGLE BEAM TO 6"X6" POST ISOMETRIC N.T.S. DOUBLE BEAM TO 6"X6" POST ISOMETRIC PERIMETER BEAM POST CHANNEL #14 TEK SCREWS BOTH SIDE #14 TEK SCREWS POST CHANNEL DOUBLE PERIMETER BEAM #14 TEK SCREWS BOTH SIDE #14 TEK SCREWS N.T.S.ISOMETRIC DOUBLE BEAM INTERIOR CONNECTION N.T.S.ISOMETRIC PERIMETER BEAM [6] #14 x 1" TEK SCREWS THRU CHANNEL INTO EACH BEAM USE APPROPRIATELY SIZED CONNECTION CHANNELS WITH SAME HARDWARE LISTED ABOVE FOR 8"X8" POST USE APPROPRIATELY SIZED CONNECTION CHANNELS WITH SAME HARDWARE LISTED ABOVE FOR 8"X8" POST INSERT / U CHANNEL BEAM 2" X 8" BEAM 2" X 8" BEAM 2" X 8" BEAM 2" X 8"COVER SHEET BEAM 2" X 8" GUTTER BEAM INSERT (8) #14 TEK SCREWS N.T.S. DOUBLE CHASE BEAM CONNECTION ISOMETRIC Š Š Š Š Š Š ŠŠ VALID FOR 1 PERMIT ONLY U.N.O. RE M A R K S DR W N CH K D DA T E SCALE: COPYRIGHT ENGINEERING EXPRESSŠ C: \ U s e r s \ c o l b y \ E n g i n e e r i n g E x p r e s s \ P r o d u c t i o n - D o c u m e n t s \ P r o j e c t s \ 2 1 - 4 0 4 6 0 P I V O T 6 X L M A S T E R P L A N S H E E T \ W o r k \ D r a w i n g s & C A D \ 2 1 - 4 0 4 6 0 d P I V O T 6 X L M P S . d w g 07 / 2 3 / 2 0 2 1 - 4 : 1 7 p m co l b y IN I T I S S U E CC B AE M 7/ 2 3 / 2 1 - - - - - - - - - - - - - - - - PHOTOCOPIES NOT TO BE USED 14" U CHANNEL INSIDE PERIMETER BEAM PERIMETER BEAM [12] #14 TEK SCREWS TEK SCREWS #14 TEK SCREWS BEAM TO POST BRACKET CONNECTION POST BEAM CHANNEL PERIMETER BEAM POST [12] #14 TEK SCREWS 1 3/4" X 3 3/4" X 0.125" SPLICE U-CHANNEL 2" X 8" BEAM(6) #14 TEK SCREWS PER BEAM TOP VIEW U-CHANNEL 3/4"X2"X.125 14" PIECES - 7 - INCHES INSIDE OF PERIMETER BEAM SCREWED TOGETHER USING 12 TEK SCREWS 1" O.C. IN THE TOP OF PERIMETER BEAM SPLICE ARE PLACED AT POST POSITIONS #14 TEK SCREW SIDE VIEW [12] #14 TEK SCREWS 1" (TYP.) N.T.S. SINGLE BEAM SPLICE ISOMETRIC 14" U CHANNEL INSIDE PERIMETER BEAM DOUBLE PERIMETER BEAM [12] #14 TEK SCREWS TEK SCREWS #14 TEK SCREWS BEAM TO POST BRACKET CONNECTION POST BEAM CHANNEL DOUBLE PERIMETER BEAM POST [12] #14 TEK SCREWS 1 3/4" X 3 3/4" X 0.125" SPLICE U-CHANNEL [2] 2" X 8" BEAM (6) #14 TEK SCREWS PER BEAM TOP VIEW U-CHANNEL 3/4"X2"X.125 14" PIECES - 7 - INCHES INSIDE OF PERIMETER BEAM SCREWED TOGETHER USING 12 TEK SCREWS 1" O.C. IN THE TOP OF PERIMETER BEAM SPLICE ARE PLACED AT POST POSITIONS SIDE VIEW [12] #14 TEK SCREWS #14 TEK SCREW 1" (TYP.) N.T.S. DOUBLE BEAM SPLICE ISOMETRIC PERIMETER BEAMPERIMETER BEAM (CORNER BEAM CONNECTION ON A SEPARATE DETAIL) POST (BEAM TO POST CONNECTION ON A SEPARATE DETAIL) KNEE BRACEKNEE BRACE (3) #14 X 1" TEK SCREWS THRU INSERT INTO BEAM. (3) #14 X 1" TEK SCREWS THRU INSERT INTO BEAM. (3) #14 X 1" TEK SCREWS THRU INSERT INTO POST. (3) #14 X 1" TEK SCREWS THRU INSERT INTO POST. EXPLODED ISOMETRIC VIEW ISOMETRIC VIEW POST KNEE BRACE PERIMETER BEAMS KNEE BRACE N.T.S. KNEE BRACE (OPTIONAL) ISOMETRIC PERIMETER BEAM PERIMETER BEAM PERIMETER BEAM POST (3) #14 X 1" TEK SCREWS THRU INSERT INTO BEAM. (2) #14 X 1" TEK SCREWS THROUGH KNEE BRACE INTO INSERT. BOTH SIDES KNEE BRACE CUT FROM BEAM. 2" X 1 3/4" X 2" X 0.125" BEAM INSERT (3) #14 X 1" TEK SCREWS THROUGH KNEE BRACE INTO INSERT. BOTH SIDES (3) #14 X 1" TEK SCREWS THRU INSERT INTO POST. SIDE VIEW ALUMINUM BEAM PER PLAN PIVOT TRACK PIVOT CAP TRACK PIN 5/16" DIA. S.S. PIN LOUVER PROFILE FOR COMPARISON LOUVER TRACK BAR PIVOT BAR CAP PIVOT BAR BEAM TEK SCREW #14 (ATTACHMENT OF PIVOT BAR TO BEAM) AT ALL PIVOT PIN LOCATIONS. TOP VIEW SIDE VIEW ISOMETRIC OUT-SIDE VIEW TEK SCREW #14 LOUVER PIVOT BAR PIVOT PIN BEAM PUSH NUT TRACK BAR PIN PIVOT BAR CAP TRACK BAR TRACK BAR PUSH NUT TRACK BAR PIN LOUVER BEAM PIVOT BAR CAP TRACK BAR BEAM PIVOT BAR PIVOT PIN LOUVER ISOMETRIC IN-SIDE VIEW PIVOT TRACK #14 SS TEK SCREW @ 6" O.C AND 3" FROM END USE (1) #12 X 1" TEK SCREW 8" O.C., STAGGERED FOR NON-STRUCTURAL GUTTER N.T.S. LOUVER ASSEMBLY DETAIL 6" TYP. 6" TYP. N.T.S. LOUVER SECTION DETAIL CORNER BEAM CONNECTION (8) #14 TEK SCREWS THROUGH BEAM INTO CORNER BEAM CONNECTION EACH SIDE BEAM TOP VIEW (8) #14 TEK SCREWS THROUGH BEAM INTO CORNER BEAM CONNECTION EACH SIDE BEAM BEAM SIDE VIEW CORNER BEAM CONNECTION - EXTRUDED WITH CAPS BEAM CORNER BEAM CONNECTION PERIMETER BEAM (8) #14 TEK SCREWS N.T.S. SINGLE BEAM CORNER CONNECTION ISOMETRIC CORNER BEAM CONNECTION (8) #14 DIA. TEK SCREWS BEAM 2 BEAM 1 PERIMETER BEAM U-PROFLE TOP VIEW (8) #14 TEK SCREWS THROUGH BEAM INTO CORNER BEAM CONNECTION EACH SIDE BEAM DOUBLE BEAM 8&+$11(/´[ô´[´[´ (8) #14 TEK SCREWS THROUGH BEAM INTO CORNER BEAM CONNECTION EACH SIDE CORNER BEAM CONNECTION BEAM DOUBLE BEAM SIDE VIEW CORNER BEAM CONNECTION - EXTRUDED WITH CAPS N.T.S. DOUBLE BEAM CORNER CONNECTION ISOMETRIC Š Š Š Š Š Š ŠŠ VALID FOR 1 PERMIT ONLY U.N.O. RE M A R K S DR W N CH K D DA T E SCALE: COPYRIGHT ENGINEERING EXPRESSŠ C: \ U s e r s \ c o l b y \ E n g i n e e r i n g E x p r e s s \ P r o d u c t i o n - D o c u m e n t s \ P r o j e c t s \ 2 1 - 4 0 4 6 0 P I V O T 6 X L M A S T E R P L A N S H E E T \ W o r k \ D r a w i n g s & C A D \ 2 1 - 4 0 4 6 0 d P I V O T 6 X L M P S . d w g 07 / 2 3 / 2 0 2 1 - 4 : 1 7 p m co l b y IN I T I S S U E CC B AE M 7/ 2 3 / 2 1 - - - - - - - - - - - - - - - - PHOTOCOPIES NOT TO BE USED 14" U CHANNEL INSIDE PERIMETER BEAM PERIMETER BEAM [12] #14 TEK SCREWS TEK SCREWS #14 TEK SCREWS BEAM TO POST BRACKET CONNECTION POST BEAM CHANNEL PERIMETER BEAM POST [12] #14 TEK SCREWS 1 3/4" X 3 3/4" X 0.125" SPLICE U-CHANNEL 2" X 8" BEAM(6) #14 TEK SCREWS PER BEAM TOP VIEW U-CHANNEL 3/4"X2"X.125 14" PIECES - 7 - INCHES INSIDE OF PERIMETER BEAM SCREWED TOGETHER USING 12 TEK SCREWS 1" O.C. IN THE TOP OF PERIMETER BEAM SPLICE ARE PLACED AT POST POSITIONS #14 TEK SCREW SIDE VIEW [12] #14 TEK SCREWS 1" (TYP.) N.T.S. SINGLE BEAM SPLICE ISOMETRIC 14" U CHANNEL INSIDE PERIMETER BEAM DOUBLE PERIMETER BEAM [12] #14 TEK SCREWS TEK SCREWS #14 TEK SCREWS BEAM TO POST BRACKET CONNECTION POST BEAM CHANNEL DOUBLE PERIMETER BEAM POST [12] #14 TEK SCREWS 1 3/4" X 3 3/4" X 0.125" SPLICE U-CHANNEL [2] 2" X 8" BEAM (6) #14 TEK SCREWS PER BEAM TOP VIEW U-CHANNEL 3/4"X2"X.125 14" PIECES - 7 - INCHES INSIDE OF PERIMETER BEAM SCREWED TOGETHER USING 12 TEK SCREWS 1" O.C. IN THE TOP OF PERIMETER BEAM SPLICE ARE PLACED AT POST POSITIONS SIDE VIEW [12] #14 TEK SCREWS #14 TEK SCREW 1" (TYP.) N.T.S. DOUBLE BEAM SPLICE ISOMETRIC PERIMETER BEAMPERIMETER BEAM (CORNER BEAM CONNECTION ON A SEPARATE DETAIL) POST (BEAM TO POST CONNECTION ON A SEPARATE DETAIL) KNEE BRACEKNEE BRACE (3) #14 X 1" TEK SCREWS THRU INSERT INTO BEAM. (3) #14 X 1" TEK SCREWS THRU INSERT INTO BEAM. (3) #14 X 1" TEK SCREWS THRU INSERT INTO POST. (3) #14 X 1" TEK SCREWS THRU INSERT INTO POST. EXPLODED ISOMETRIC VIEW ISOMETRIC VIEW POST KNEE BRACE PERIMETER BEAMS KNEE BRACE N.T.S. KNEE BRACE (OPTIONAL) ISOMETRIC PERIMETER BEAM PERIMETER BEAM PERIMETER BEAM POST (3) #14 X 1" TEK SCREWS THRU INSERT INTO BEAM. (2) #14 X 1" TEK SCREWS THROUGH KNEE BRACE INTO INSERT. BOTH SIDES KNEE BRACE CUT FROM BEAM. 2" X 1 3/4" X 2" X 0.125" BEAM INSERT (3) #14 X 1" TEK SCREWS THROUGH KNEE BRACE INTO INSERT. BOTH SIDES (3) #14 X 1" TEK SCREWS THRU INSERT INTO POST. SIDE VIEW ALUMINUM BEAM PER PLAN PIVOT TRACK PIVOT CAP TRACK PIN 5/16" DIA. S.S. PIN LOUVER PROFILE FOR COMPARISON LOUVER TRACK BAR PIVOT BAR CAP PIVOT BAR BEAM TEK SCREW #14 (ATTACHMENT OF PIVOT BAR TO BEAM) AT ALL PIVOT PIN LOCATIONS. TOP VIEW SIDE VIEW ISOMETRIC OUT-SIDE VIEW TEK SCREW #14 LOUVER PIVOT BAR PIVOT PIN BEAM PUSH NUT TRACK BAR PIN PIVOT BAR CAP TRACK BAR TRACK BAR PUSH NUT TRACK BAR PIN LOUVER BEAM PIVOT BAR CAP TRACK BAR BEAM PIVOT BAR PIVOT PIN LOUVER ISOMETRIC IN-SIDE VIEW PIVOT TRACK #14 SS TEK SCREW @ 6" O.C AND 3" FROM END USE (1) #12 X 1" TEK SCREW 8" O.C., STAGGERED FOR NON-STRUCTURAL GUTTER N.T.S. LOUVER ASSEMBLY DETAIL 6" TYP. 6" TYP. N.T.S. LOUVER SECTION DETAIL CORNER BEAM CONNECTION (8) #14 TEK SCREWS THROUGH BEAM INTO CORNER BEAM CONNECTION EACH SIDE BEAM TOP VIEW (8) #14 TEK SCREWS THROUGH BEAM INTO CORNER BEAM CONNECTION EACH SIDE BEAM BEAM SIDE VIEW CORNER BEAM CONNECTION - EXTRUDED WITH CAPS BEAM CORNER BEAM CONNECTION PERIMETER BEAM (8) #14 TEK SCREWS N.T.S. SINGLE BEAM CORNER CONNECTION ISOMETRIC CORNER BEAM CONNECTION (8) #14 DIA. TEK SCREWS BEAM 2 BEAM 1 PERIMETER BEAM U-PROFLE TOP VIEW (8) #14 TEK SCREWS THROUGH BEAM INTO CORNER BEAM CONNECTION EACH SIDE BEAM DOUBLE BEAM 8&+$11(/´[ô´[´[´ (8) #14 TEK SCREWS THROUGH BEAM INTO CORNER BEAM CONNECTION EACH SIDE CORNER BEAM CONNECTION BEAM DOUBLE BEAM SIDE VIEW CORNER BEAM CONNECTION - EXTRUDED WITH CAPS N.T.S. DOUBLE BEAM CORNER CONNECTION ISOMETRIC Š Š Š Š Š Š ŠŠ VALID FOR 1 PERMIT ONLY U.N.O. RE M A R K S DR W N CH K D DA T E SCALE: COPYRIGHT ENGINEERING EXPRESSŠ C: \ U s e r s \ c o l b y \ E n g i n e e r i n g E x p r e s s \ P r o d u c t i o n - D o c u m e n t s \ P r o j e c t s \ 2 1 - 4 0 4 6 0 P I V O T 6 X L M A S T E R P L A N S H E E T \ W o r k \ D r a w i n g s & C A D \ 2 1 - 4 0 4 6 0 d P I V O T 6 X L M P S . d w g 07 / 2 3 / 2 0 2 1 - 4 : 1 7 p m co l b y IN I T I S S U E CC B AE M 7/ 2 3 / 2 1 - - - - - - - - - - - - - - - - N.T.S. HOST LEDGER CONNECTION DETAIL N.T.S. ROOF PIVOT HOST CONNECTION DETAIL FOR CONCRETE ATTACHMENT: [2] 1/4" DIAM. ITW STAINLESS STEEL TAPCON INTO WALL W/ 3" EMBEDMENT AND 3" EDGE DISTANCE, SPACED 16" O.C FOR WOOD ATTACHMENT: 30 PSF GRAVITY LOAD OR LESS: [2] 3/8" DIAM. S.S. WOOD LAG SCREWS INTO WALL W/ 3" THREAD ENGAGEMENT AND 3/4" MINIMUM EDGE DISTANCE, SPACED 16" O.C. 30 TO 40 PSF GRAVITY LOAD: [2] 3/8" DIAM. S.S. WOOD LAG SCREWS INTO WALL W/ 3" THREAD ENGAGEMENT AND 3/4" MINIMUM EDGE DISTANCE, SPACED 12" O.C. 40 TO 60 PSF GRAVITY LOAD: [2] 3/8" DIAM. S.S. WOOD LAG SCREWS INTO WALL W/ 3" THREAD ENGAGEMENT AND 3/4" MINIMUM EDGE DISTANCE, SPACED 8" O.C. FOR GROUT-FILLED CMU ATTACHMENT: [2] 1/4" DIAM. S.S. HILTI KWIK-CON II+ INTO BLOCK FACE W/ 1-3/4" EMBEDMENT AND 3" MINIMUM EDGE DISTANCE, SPACED 16" O.C. ALUMINUM BEAM PER PLAN 9/16" HOLE DRILLED FOR SCREW INSTALLATION 1" 1" 16" 9/16" HOLE DRILLED FOR SCREW INSTALLATION TYPICAL 16" O.C. STUDS 1" 1" 16"16"16" EXISTING HOST STRUCTURE SHALL BE EITHER 3000 PSI POURED CONCRETE, OR ASTM90 GROUT-FILLED CMU OR #2 SYP WOOD (G=0.55 OR BETTER) AS VERIFIED BY OTHERS 3" M I N . EMBED.TYPICAL ANCHOR PATTERN (TO WOOD STUDS SHOWN) HOST STRUCTURE GUTTER PERIMETER BEAM 2 3 4" 4 1 4" 6"6" 2 3 4" 1 8" THICK PERIMETER BEAM GUTTER ROOF BRACKET ROOF DIAMETER: R 2.00" MATERIAL: AISI 304 [3] 5 16‘/$*6&5(:6:1 2" MIN. THREAD PENETRATION 3 " LOCKING PIN 5/16" DIA. S.S. PIVOT PIN NOTE: PERIMETER BEAM ATTACHED TO PIVOT MOUNT BY [4] #14 X 1" SS TEK SCREWS. PIVOT MOUNT ATTACHED TO ROOF RAFTERS BY [3] 5/16" DIAMETER STAINLESS STEEL LAG SCREWS WITH MINIMUM 2-1/2" THREAD PENETRATION, 0.75" EDGE DISTANCE, 1.25" APART MIN., INTO SOUTHERN YELLOW PINE #2 WOOD (G=0.55) OR BETTER. PIVOTS MAY BE SPACED AT A MAXIMUM OF 48" O.C. PHOTOCOPIES NOT TO BE USED Š Š Š Š Š Š ŠŠ VALID FOR 1 PERMIT ONLY U.N.O. RE M A R K S DR W N CH K D DA T E SCALE: COPYRIGHT ENGINEERING EXPRESSŠ C: \ U s e r s \ c o l b y \ E n g i n e e r i n g E x p r e s s \ P r o d u c t i o n - D o c u m e n t s \ P r o j e c t s \ 2 1 - 4 0 4 6 0 P I V O T 6 X L M A S T E R P L A N S H E E T \ W o r k \ D r a w i n g s & C A D \ 2 1 - 4 0 4 6 0 d P I V O T 6 X L M P S . d w g 07 / 2 3 / 2 0 2 1 - 4 : 1 7 p m co l b y IN I T I S S U E CC B AE M 7/ 2 3 / 2 1 - - - - - - - - - - - - - - - - N.T.S. HOST LEDGER CONNECTION DETAIL N.T.S. ROOF PIVOT HOST CONNECTION DETAIL FOR CONCRETE ATTACHMENT: [2] 1/4" DIAM. ITW STAINLESS STEEL TAPCON INTO WALL W/ 3" EMBEDMENT AND 3" EDGE DISTANCE, SPACED 16" O.C FOR WOOD ATTACHMENT: 30 PSF GRAVITY LOAD OR LESS: [2] 3/8" DIAM. S.S. WOOD LAG SCREWS INTO WALL W/ 3" THREAD ENGAGEMENT AND 3/4" MINIMUM EDGE DISTANCE, SPACED 16" O.C. 30 TO 40 PSF GRAVITY LOAD: [2] 3/8" DIAM. S.S. WOOD LAG SCREWS INTO WALL W/ 3" THREAD ENGAGEMENT AND 3/4" MINIMUM EDGE DISTANCE, SPACED 12" O.C. 40 TO 60 PSF GRAVITY LOAD: [2] 3/8" DIAM. S.S. WOOD LAG SCREWS INTO WALL W/ 3" THREAD ENGAGEMENT AND 3/4" MINIMUM EDGE DISTANCE, SPACED 8" O.C. FOR GROUT-FILLED CMU ATTACHMENT: [2] 1/4" DIAM. S.S. HILTI KWIK-CON II+ INTO BLOCK FACE W/ 1-3/4" EMBEDMENT AND 3" MINIMUM EDGE DISTANCE, SPACED 16" O.C. ALUMINUM BEAM PER PLAN 9/16" HOLE DRILLED FOR SCREW INSTALLATION 1" 1" 16" 9/16" HOLE DRILLED FOR SCREW INSTALLATION TYPICAL 16" O.C. STUDS 1" 1" 16"16"16" EXISTING HOST STRUCTURE SHALL BE EITHER 3000 PSI POURED CONCRETE, OR ASTM90 GROUT-FILLED CMU OR #2 SYP WOOD (G=0.55 OR BETTER) AS VERIFIED BY OTHERS 3" M I N . EMBED.TYPICAL ANCHOR PATTERN (TO WOOD STUDS SHOWN) HOST STRUCTURE GUTTER PERIMETER BEAM 2 3 4" 4 1 4" 6"6" 2 3 4" 1 8" THICK PERIMETER BEAM GUTTER ROOF BRACKET ROOF DIAMETER: R 2.00" MATERIAL: AISI 304 [3] 5 16‘/$*6&5(:6:1 2" MIN. THREAD PENETRATION 3 " LOCKING PIN 5/16" DIA. S.S. PIVOT PIN NOTE: PERIMETER BEAM ATTACHED TO PIVOT MOUNT BY [4] #14 X 1" SS TEK SCREWS. PIVOT MOUNT ATTACHED TO ROOF RAFTERS BY [3] 5/16" DIAMETER STAINLESS STEEL LAG SCREWS WITH MINIMUM 2-1/2" THREAD PENETRATION, 0.75" EDGE DISTANCE, 1.25" APART MIN., INTO SOUTHERN YELLOW PINE #2 WOOD (G=0.55) OR BETTER. PIVOTS MAY BE SPACED AT A MAXIMUM OF 48" O.C. PHOTOCOPIES NOT TO BE USED