Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Manual J Calcs
AriAlima. Load Short Form Entire House Mountain Air Mechanical 601 W 2nd Street, Rifle, Co 81650 Phone: 970-6254352 Fax: 970-625-4356 Email: sar@mountainair.biz v.1- h r,l 1 For: Wells Residence 540 Panoramic Drive, Silt, CO 81652 Job: Date: Sep 10, 2025 By: - Htg Clg Infiltration Outside db (OF) -2 93 Method Detailed Inside db (OF) 70 75 Shielding 3 (partial) Design TD (OF) 72 18 Stories 1 Daily range - H Inside humidity (%) 30 50 Moisture difference (grAb) 35 -44 HEATING EQUIPMENT Make Mitsubishi Electric Trade Mitsubishi Electric Model MXZ-3C24NAHZ4`** AHRI ref 209847184 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capacitybalancepoint= 11 OF 9.25 HSPF2 24800 Btu h @ 47° F 36 OF 760 cfm 0.040 cfm/Btuh 0 in H2O Backup: Inniit = A kW C7irtrud = 1a177 Rtritr inn Art IF COOLING EQUIPMENT Make Mitsubishi Electric Trade Mitsubishi Electric Cond MXZ-3C24NAHZ4*** Coil AHRI ref 209847184 Efficiency 11.8 EER2,17.25 SEER2 Sensible cooling 15960 Btuh Latent cooling 6840 Btuh Total cooling 22800 Btuh Actual air flow 760 cfm Air flow factor 0.051 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.96 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) Bedroom1 175 3949 2869 157 145 Bath 1 63 1418 325 56 16 WIC1 68 665 127 26 6 Kitchen 226 2762 3094 110 157 Living 301 4630 5121 184 260 Bedroom2 144 3637 2619 145 133 Laundry 53 658 584 26 30 MECH 32 806 140 32 7 Bathroom2 Lwnnn 41 n 171 39 7 A� 2 BoWtallc values have been manualk overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed- ti wr gF•tsaR- 2025-Sep-10 17:37:36 A& Right-Suite®Universal 2024 24.0.02 RSU59834 Pape 1 b10neDrive%DesktopU_oad Calcs\540 Panoramic.rup Calc = MA Front Door faces: E .ZINN Entire House 1127 19122 14993 760 760 Other equip loads 0 0 Equip. @ 0.98 RSM 14649 Latent cooling 600 l I l 760 760 TOTALS 1127 19122 15249 Sold/ifallc values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. f 11- wrightsol't- 2025•Sep-1017:37:36 Right -Suite® Universal 2024 24.0.02 RSU59834 Page 2 b\OneDriveXDesktopXLoad Calcst540 Panoramic.rup Calc = MJ8 Front Door faces: E Building Analysis 1W7 Fa _ rra fz Entire House Mountain Air Mechanical 601 W 2nd Street, Rifle, Co 81650 Phone: 970-625-4352 Fax: 970-6254356 Email: sar@mountainsir.biz For: Wells Residence 540 Panoramic Drive, Silt, CO 81652 Job: Date: Sep 10, 2026 By: Design Conditions Location: Indoor: Heating Cooling Garfield Co Rgnl, CO, US Indoor temperature (OF) 70 75 Elevation: 5545 ft Design TD (`F) 72 18 Latitude: 40ON Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 35.3 -44.1 Drybulb (OF) -2 93 Infiltration: Dailyrange (OF) - 35 (H ) Method Detailed Wet bulb (OF) - 59 Shielding 3 (partial) Wind speed (mph) 15.0 7.5 Stories 1 Heating Component Btu h/f 2 Btuh % of load Walls 4.9 7843 41.0 Glazing 21.6 6610 34.6 Doors 0 0 0 Ceilings 2.1 2353 12.3 Floors 2.1 2315 12.1 Infiltration 0 0 0 Duds 0 0 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 19122 100.0 Btu h/f 2 Btuh % of load —Component Walls 0.9 1394 9.3 Glazing 30.0 9171 61.2 Doors 0 0 0 Ceilings 0.5 569 3.8 Floors 0.5 569 3.8 Infiltration 0 0 0 Ducts 0 0 Ventilation 0 0 Internal gains 3290 21.9 Blower 0 0 Adjustments 0 Total 1 1 14993 100.0 Latent Cooling Load = 600 Btuh Overall U-%elue = 0.065 Btuh/ff2-°F, Window / Floor Area = 272 % WARNING: window to floor area ratio = 27.2% - more than 25%. Roors \ANTS. if C@7jrg e Sold/italic values have been manually overridden TI►►iip Irtffn@i Gins _ Flms i Celirgs r + Wrlghtsotft` 2025-Sep-1017:37:36 - -- -•- - Right -Suite® Universal 202424.0.02 RSU598M Page 1 ...b%OneDrtve%DesktoplLoad Calcs1540 Panoramic.rup Calc = MJ8 Front Door faces: E Component Constructions " Entire House ., v.. Mountain Air Mechanical 601 W 2nd Street, Rifle, Co 81650 Phone: 970-625-4362 Fax: 970•625-4356 Email: sar@mountainair.biz For: Wells Residence 540 Panoramic Drive, Silt, CO 81652 Job: Data: Sep 10, 2025 By: Design Conditions_ Location: Indoor: Heating Cooling Garfield Co Rgnl, CO, US Indoor temperature (OF) 70 75 Elevation: 5545 ft Design TD (OF) 72 18 Latitude: 40°N Relative humidity (°/a) 30 50 Outdoor: Heating Cooling Moisture difference (grAb) 35.3 -44.1 Dry bulb (°F) -2 93 Infiltration: Dailyrange (OF) - 35 ( H ) Method Detailed Wet bu Ib (° F) - 59 Shielding 3 (partial) Wind speed (mph) 15.0 7.5 Stories 1 Construction descriptions Or Area U-value Instil R Htg HTM Loss Clg HTM Gain T BbdJlt --°F f1-'F/Bhrh 13t1hfiF Btuh Bhb/W Btuh Walls 12E-0sw: Firm wall, wd ext, 5/8" wood shth, r-19 cav ins, 2"x6" wood n 302 0.068 19.0 4.90 1480 0.87 263 firm, 16" o.c. stud, r-1 int bd ins a 474 0.068 19.0 4.90 2321 0.87 413 s 308 0.068 19.0 4.90 1506 0.87 268 w 518 0.068 19.0 4.90 2537 0.87 451 all 1602 0.068 19.0 4.90 7843 0.87 1394 Partitions (none) Windows 1 D-c2ow: 2 glazing, clr outr, air gas, wd frm mat, cir innr, 1/4" gap, 1/4" n 34 0.300 0 21.6 729 11.1 376 thk; NFRC rated (SHGC=0.30); 6.67 ft head ht a 216 0.300 0 21.6 4666 33.6 7267 s 23 0.300 0 21.6 486 17.5 393 w 34 0.300 0 21.6 729 33.6 1135 all 306 0.300 0 21.6 6610 30.0 9171 Doors (none) Ceilings 18A-38md: Rf/dg ceiling, mtl roof mat, frm cons, 1/2" gypsum board int 1127 0.029 38.0 2.09 2353 0.50 569 fnsh, 6" thkns, r-50 ceil ins Floors 19A-30cstp: Fir floor, frm flr, 12" thkns, r-30 cav ins, tight crwl ovr 1127 0.034 30.0 2.05 2315 0.51 569 ti -fl#- wrilghtsOR` 2025-Sep-1017:37:36 A � .- .-..._-.,.. Right -Suite® Universal 2024 24.0.02 RSU59834 Pagel b\OneDdve\Desktop\Load Calcs\540 Panoramic.rup Calc = MJ8 Front Door faces: E . ., Date: Component Constructions P Date: Sep 10, 2025 Bedrooml By: Mountain Air Mechanical 601 W 2nd Street, Rifle, Co 81650 Phone: 970-625-4352 Fax: 970-625-4356 Email: sar@mountainair.biz ,�'� S�M �Pc!1,1(1hl�t?tip - — For: Wells Residence 540 Panoramic Drive, Silt, CO 81652 lesion Conditic Location: Indoor: Heating Cooling Garfield Co Rgnl, CO, US indoor temperature (OF) 70 75 Elevation: 5545 ft Design 1D (OF) 72 18 Latitude: 40ON Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (grAb) 35.3 -44.1 Dry bulb (OF) -2 93 Infiltration: Dailyrange (OF) - 35 ( H) Method Detailed Wetbulb (°F) - 59 Shielding 3 (partial) Wind speed (mph) 15.0 7.5 Stories 1 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain f` Bb9UR'`--"F fY-"F/Bbft BMW Btuh Bhhllt= Btuh Walls 12E-Osw: Fnn wall, wd ext, 5/8" wood shth, r-19 cav ins, 2"x6" wood n 188 0.068 19.0 4.90 918 0.87 163 frm, 16" o.c. stud, r-1 int bd ins a 134 0.068 19.0 4.90 654 0.87 116 all 321 0.068 19.0 4.90 1572 0.87 279 Partitions (none) Windows ID-c2ow: 2 glazing, clr outr, air gas, wd frm mat, clr innr, 1/4" gap, 1/4" n 23 0.300 0 21.6 486 11.1 250 thk; NFRC rated (SHGC=0.30); 6.67 ft head ht a 54 0.300 0 21.6 1166 33.6 1817 all 77 0.300 0 21.6 1652 27.0 2067 Doors (none) Ceilings 18A-38md: Rf/dg ceiling, mtl roof mat, frm cons, 1/2" gypsum board int 175 0.029 38.0 2.09 365 0.50 88 fish, 6" thkns, r-50 cell ins Floors 19A-30cstp: Flr floor, frm fir, 12" thkns, r-30 cav ins, tight crwl ovr 175 0.034 30.0 2.05 360 0.51 88 } ; wrigFrtsoft" 2025-Sep-1017:37:36 Rig ht-Suite® Universal 2024 24.0.02 RSU59834 Page 2 ...b\OneDrive\Desktop\Load Calcs\540 Panoramic.rup Calc = MJ8 Front Door faces: E .,ri. Component Constructions Job: ,p Date: Sep 70, 2025 rc at1iCC�r Bath I By: Mountain Air Mechanical 601 W 2nd Street, Rifle, Co 81650 Phone: 970-625-4352 Fax: 970-625-4356 Email: sar@mountainair.biz For: Wells Residence 540 Panoramic Drive, Silt, CO 81652 Design• • • I J Location: Indoor: Heating Cooling Garfield Co Rgnl, CO, US Indoor temperature (OF) 70 75 Elevation: 5545 ft Design TD (OF) 72 18 Latitude: 40oN Relative humidity (°/a) 30 50 Outdoor: Heating Cooling Moisture difference (grAb) 35.3 -44.1 Dry bulb (OF) -2 93 Infiltration: Dailyrange (OF) - 35 ( H ) Method Detailed Wet bulb (OF) - 59 Shielding 3 (partial) Wind speed (mph) 15.0 7.5 Stories 1 Construction descriptions or Area u-vane Insul R Htg HTM Loss Clg HTM Gain Btuh f BhdhIR-°F fF-"F/Bbii Bhhir Btuh Bhhff Walls 12E-Osw: Frm wall, wd ext, 5/8" wood shth, r-19 cav ins, 2"x6" wood n 115 0.068 19.0 4.90 562 0.87 100 frm, 16" o.c. stud, r-1 int bd ins w 72 0.068 19.0 4.90 353 0.87 63 all 187 0.068 19.0 4.90 914 0.87 163 Partitions (none) Windows 1 D-c2ow: 2 glazing, clr outr, air gas, wd frrn mat, dr innr, 1/4" gap, 1/4" n 11 0.300 0 21.6 243 11.1 125 thk; NFRC rated (SHGC=0.30); 6.67 ft head ht Doors (none) Ceilings 18A-38md: Rf/clg ceiling, mill roof mat, fnn cons, 1/2" gypsum board int 63 0.029 38.0 2.09 132 0.50 32 fish, 6" thkns, r-50 ceil ins Floors 19A-30cstp: Fir floor, firm fir, 12" thkns, r-30 cav ins, tight crwl ovr 63 0.034 30.0 2.05 129 0.51 32 i+ wrilgli scsfa 2025-Sep-1017:37:36 Rig ht-Suite® Universal 2024 24.0.02 RSU59834 Page 3 b\OneDrive\DeWop\Load Calcs\540 Panoramic.rup Cate = MJ8 Front Door faces: E Component Constructions Job: Date: Sep 10, 2025 �c entca wici By: H.V R,C Mountain Air Mechanical 601 W 2nd Street, Rifle, Co 81650 Phone: 970-625-4352 Fax: 970-6254356 Email: sar@mountainair.biz ___ __��•ect intormation For: Wells Residence 540 Panoramic Drive, Silt, CO 81652 Design Conditions Location: Indoor: Heating Cooling Garfield Co Rgnl, CO, US Indoor temperature (OF) 70 75 Elevation: 5545 ft Design TD (OF) 72 18 Latitude: 40'N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 35.3 -44.1 Dry bulb (OF) -2 93 Infiltration: Dailyrange (OF) - 35 ( H ) Method Detailed Wet bulb (OF) - 59 Shielding 3 (partial) Wind speed (mph) 15.0 7.5 Stories 1 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain 1P Bth/R'--°F ft �FlBhii Bhhll! Btuh 13WR Btut Walls 12E-Osw: Frm wall, wd ext, 5/8" wood shth, r-19 cav ins, 2"x6" wood w 78 0.068 19.0 4.90 382 0.87 68 frm, 16" o.c. stud, r-1 int bd ins Partitions (none) Windows (none) Doors (none) Ceilings 18A-38md: Rf/clg ceiling, mtl roof mat, frm cons, 1/2" gypsum board int 68 0.029 38.0 2.09 143 0.50 34 fnsh, 6" thkns, r-50 ceil ins Floors 19A-30cstp: Fir floor, frm fir, 12" thkns, r-30 cav ins, tight crwl ovr 68 0.034 30.0 2.05 140 0.51 34 t wrilghtsOft- 2025•Sep-1017:37:36 Right -Suite® Universal 202424.0.02RSU59834 Page ..b10neDdvelDesktopM-oad Calcs\540 Panoramic.rup Calc = MJ8 Front Door faces: E tea, Component Constructions Job: p Date: Sep 10, 2025 Kitchen By: Mountain Air Mechanical 601 W 2nd Street, Rifle, Co 81650 Phone: 970-625-4352 Fax: 970-6254356 Email: sar@mountalnair.biz mloect intormation For: Wells Residence 540 Panoramic Drive, Silt, CO 81652 Design Conditions Location: Indoor: Heating Cooling Garfield Co Rgnl, CO, US Indoor temperature (OF) 70 75 Elevation: 5545 ft Design TD (OF) 72 18 Latitude: 40ON Relative humidity N 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 35.3 -44.1 Dry bulb (OF) -2 93 Infiltration: Dailyrange (OF) - 35 ( H ) Method Detailed Wet bulb ('F) - 59 Shielding 3 (partial) Wind speed (mph) 15.0 7.5 Stories 1 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain R' Btuhff--°F ft'-"FlBbii Bbh/R' Bhih BhhAP Btuh Walls 12E-Osw: Frm wall, wd ext. 5/8" wood shth, r-19 cav ins, 2"x6" wood w 224 0.068 19.0 4.90 1098 0.87 195 firm, 16" o.c. stud, r-1 int bd ins Partitions (none) Windows 1 D-c2ow: 2 glazing, cir outr, air gas, wd firm mat, clr innr, 1/4" gap, 1/4" w 34 0.300 0 21.6 729 33.6 1135 thk; NFRC rated (SHGC=0.30); 6.67 ft head ht Doors (none) Ceilings 18A-38md: Rf/clg ceiling, mtl roof mat, frm cons, 1/2" gypsum board int 226 0.029 38.0 2.09 471 0.50 114 fish, 6" thkns, r-50 ceil ins Floors 19A-30cstp: Fir floor, firm fir, 12" thkns, r-30 cav ins, tight crwl ovr 226 0.034 30.0 2.05 464 0.51 114 }_ f wrigh Z s o- 4. 2025•Sep-1017:37:36 Rig ht-Suite® Universal 2024 24.0.02 RSU59834 Page 5 sktopXLoad Calc b\OneDdveXDes\540 Panoramic.rup Calc = M.18 Front Door faces: E Component Constructions Job: �iarTr�s� AIR p Date: Sep 10, 2025 Living By: Mountain Air Mechanical 601 W 2nd Street, Rifle, Co 81650 Phone: 970-625-4352 Fax: 97M25-4356 Email: sar@mountainair.biz ����•ject intormation For: Wells Residence 540 Panoramic Drive, Silt, CO 81652 ® 0 0 0 0 Location: Indoor: Heating Cooling Garfield Co Rgnl, CO, US Indoor temperature (7) 70 75 Elevation: 5545 ft Design TD (OF) 72 18 Latitude: 40ON Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 35.3 -44.1 Dry bulb (OF) -2 93 Infiltration: Dailyrange (OF) - 35 ( H ) Method Detailed Wet bulb (°F) - 59 Shielding 3 (partial) Wind speed (mph) 15.0 7.5 Stories 1 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain fe BtuhlR'-'F f`-'FIBbb BhhAF Btuh BM/F Btuh Walls 12E-Osw. Frm wall, wd ext, 5/8" wood shth, r-19 cav ins, 2"x6" wood a 215 0.068 19.0 4.90 1050 0.87 187 frm, 16" o.c. stud, r-1 int bd ins Partitions (none) Windows 1 D-c2ow: 2 glazing, cir outr, air gas, wd frm mat, clr innr, 114" gap, 1/4" a 108 0.300 0 21.6 2333 33.6 3634 thk; NFRC rated (SH1313=0.30); 6.67 ft head ht Doors (none) Ceilings 18A-38md: Rf/clg ceiling, mtl roof mat, frm cons, 1/2" gypsum board int 301 0.029 38.0 2.09 628 0.50 152 fish, 6" thkns, r-50 veil ins Floors 19A-30cstp: Fir floor, firm fir, 12" thkns, r-30 cav ins, tight crwl ovr 301 0.034 30.0 2.05 618 0.51 152 4 .1 , Wright$inf 2025-Sep-1017:37:36 ^� TT Right -Suited!) Universal 2024 24.0.02 RSU59834 Page MCA ...b\OneDriveMDesktopNLoad Calcs\540 Panoramic.rup Calc = MJB Front Door faces: E . Component Constructions Job: Com P Date: Sep 10, 2025 Pru rsrrrco Bedroom2 By: Mountain Air Mechanical 601 W 2nd Street, Rifle, Co 81650 Phone: 970-625-4352 Fax: 970-625-4356 Email: sar@mountainair.biz • -ect intormation For: Wells Residence 540 Panoramic Drive, Silt, CO 81652 ®- e o • • Location: Indoor: Heating Cooling GarFeld Co Rgnl, CO, US Indoor temperature (°F) 70 75 Elevation: 5545 ft Design TD (°F) 72 18 Latitude: 40oN Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 35.3 -44.1 Dry bulb (OF) -2 93 Infiltration: Dailyrange (°F) - 35 ( H ) Method Detailed Wetbulb (°F) - 59 Shielding 3 (partial) Wind speed (mph) 15.0 7.5 Stories 1 Construction descriptions Or Area u-value Insul R Htg HTM Loss Clg HTM Gain fF BbhfiP--"F fl-"FlBbit Bbblw BWh Bbhff atuh Walls 12E-Osw: Frm wall, wd ext, 5/8" wood shth, r-19 cav ins, 274" wood a 126 0.068 19.0 4.90 617 0.87 110 frm, 16" o.c. stud, r-1 int bd ins s 158 0.068 19.0 4.90 771 0.87 137 all 284 0.068 19.0 4.90 1388 0.87 247 Partitions (none) Windows ID-c2ow: 2 glazing, clr outr, air gas, wd fmt mat, clr innr, 1/4" gap, 1/4" a 54 0.300 0 thk; NFRC rated (SHGC=0.30); 6.67 ft head ht s 23 0.300 0 all 77 0.300 0 Doors (none) Ceilings 18A-38md: Rf/clg ceiling, mtl roof mat, firm cons, 1/2" gypsum board int 144 0.029 38.0 fnsh, 6" thkns, r-50 cell ins Floors 19A-30cstp: Fir floor, firm fir, 12" thkns, r-30 cav ins, tight crvvl ovr 144 0.034 30.0 21.6 1166 33.6 1817 21.6 486 17.5 393 21.6 1652 28.9 2210 2.09 301 0.50 73 2.05 296 0.51 73 t -T- wrightme ft- 2025-Sep-1017:37:36 .......... Right -Suite® Universal202424.0.02 RSU59834 Page b\OneDdve1Desktop%Load CalcsX540 Panoramic.rup Cale = MJ8 Front Door faces: E ComComponent Constructions Job: P Date: Sep 10, 2025 Laundry By: Mountain Air Mechanical 601 W 2nd Street, Rifle, Co 81650 Phone: 970-6254352 Fax: 970-625-4356 Email: sar@mountaineir.biz Project• • For: Wells Residence 540 Panoramic Drive, Silt, CO 81652 Design Conditions Location: Indoor: Heating Cooling Garfield Co Rgnl, CO, US Indoor temperature (°F) 75eld Elevation: 5545 ft Design TD (°F) 72 18 Latitude: 40°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 35.3 -44.1 Dry bulb (°F) -2 93 Infiltration: Dailyrange (°F) - 35 ( H ) Method Detailed Wet bulb (°F) - 59 Shielding 3 (partial) Wind speed (mph) 15.0 7.5 Stories 1 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain 1P Btuh/R{"F tt-"F/Bhh Bbjhff Bbrh i3hi M Btuh Walls 12E-Osw: Frm wall, wd ext, 5/8" wood shth, r-19 cav ins, 2"x6" wood w 90 0.068 19.0 4.90 441 0.87 78 frm, 16" o.c. stud, r-1 int bd ins Partitions (none) Windows (none) Doors (none) Ceilings 18A-38md: Rf/clg ceiling, mtl roof mat, firm cons, 1/2" gypsum board int 53 0.029 38.0 2.09 110 0.50 26 fish, 6" thkns, r-50 ceil ins Floors 19A-30cstp: Fir floor, firm fir, 12" thkns, r-30 cav ins, tight rxvvl ovr 53 0.034 30.0 2.05 108 0.51 27 2025-Sep-10 17:37:36 wrightrsvf# .,,.... Right-Suita®Universal 202424.0.02 RSU59834 Page b\OneDdve\DesktopXLoad Calcs\540 Panoramic.rup Calc = MJ8 Front Door faces: E arii�4lr► Component Constructions Job: p Date: Sep 10, 2025 �c n t ca MECH By: H.MA,C Mountain Air Mechanical tr01 W 2nd Street, Rifle, Co 81650 Phone: 970.625-4352 Fax: 970-625-4356 Email: sar@mountainair.biz For: Wells Residence 540 Panoramic Drive, Silt, CO 81652 7P-Sinn Conditic Location: Indoor: Heating Cooling Garfield Co Rgnl, CO, US Indoor temperature (OF) 70 75 Elevation: 5545 ft Design TD (OF) 72 18 Latitude: 40°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 35.3 -44.1 Dry bulb (OF) -2 93 Infiltration: Dailyrange (OF) - 35 (H ) Method Detailed Wet bulb (°F) - 59 Shielding 3 (partial) Wind speed (mph) 15.0 7.5 Stories 1 Area U value Insul R Htg HTM Loss Clg HTM Gain Construction descriptions Or tt BbAdR`--"F T--"fifth Btdiff Btuh BbhNF Btuh Walls 12E-0sw: Frm wall, wd ext, 5/8" wood shth, r-19 cav ins, 2"x6" wood frm, 16" o.c. stud, r-1 int bd ins Partitions (none) Windows (none) Doors (none) Ceilings 18A-38md: Rf/dg ceiling, mtl roof mat, firm cons, 1/2" gypsum board int fish, 6" thkns, r-50 ceil ins Floors 19A-30cstp: Fir floor, firm flr, 12" thkns, r-30 cav ins, tight crwl ovr s 84 0.068 19.0 4.90 411 0.87 73 w 54 0.068 19.0 4.90 264 0.87 47 all 138 0.068 19.0 4.90 676 0.87 120 32 0.029 38.0 2.09 66 0.50 32 0.034 30.0 2.05 65 0.51 16 16 ti wril htsa t- 2025-Sep-1017:37:36 AA�Lg_. _,. ,-, Right -Su Re® Universal202424.0.02 RSU59834 Page ..b\OneDdve\Desktop\Load Calcs\540 Panoramic.rup Calc = MJ8 Front Door faces: E ,•.,, Component Constructions Job: Date: Sep 10, 2025 �:� .., Co Bathroom2 By: Ku.R.� !.--'rq �.,.,, Mountain Air Mechanical 601 W 2nd Street, Rifle, Co 81650 Phone: 970-6254352 Fax: 970-625-4356 Email: sar@moluntainair.biz 1`soli==•�.�I;'!(`r`[�I.1Nw:2?`ca_ — For: Wells Residence 540 Panoramic Drive, Silt, CO 81652 Design Conditions Location: Indoor: Heating Cooling Garfield Co Rgnl, CO, US Indoor temperature (OF) 70 75 Elevation: 5545 ft Design TD (OF) 72 18 Latitude: 40°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (grAb) 35.3 -44.1 Dry bulb (OF) -2 93 Infiltration: Dailyrange (OF) - 35 ( H ) Method Detailed Wet bulb (*F) - 59 Shielding 3 (partial) Wind speed (mph) 15.0 7.5 Stories 1 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain 1! BWhIR'--'F tr°--F/Bhh BhhAF Btuh Bhh/lF Ruh Walls (none) Partitions (none) Windows (none) Doors (none) Ceilings 18A-38md: Rf/Gg ceiling, mtl roof mat, firm cons, 1/2" gypsum board int 41 0.029 38.0 2.09 86 0.50 21 fish, 6" thkns, r-50 ceil ins Floors 19A-30cstp: Fir floor, frm fir, 12" thkns, r-30 cav ins, tight crYA ovr 41 0.034 30.0 2.05 85 0.51 21 i p. W�gl� �C�i4 2025-Sep-1017:37:36 -..w,_.... Right -Suite® Universal 2024 24.0.02 RSU59834 Page10 b\OneDtive\Desktop\Load Calcs\540 Penoramic.rup Calc = MJB Front Door faces: E h/F--7-7- � Component Constructions Job: ,w, /� p Date: Sep 10, 2025 al WIC2 By.V A,n " = Mountain Air Mechanical 601 W 2nd Street, Rifle, Co 81660 Phone: 970-625-4352 Fax: 970-625.4356 Email: sar@mountainair.biz NE&Leject in.tormation For: Wells Residence 540 Panoramic Drive, Silt, CO 81652 Design Conditions Location: Indoor: Heating Cooling Garfield Co Rgnl, CO, US Indoor temperature (°F) 70 75 Elevation: 5545 ft Design 1D (°F) 72 18 Latitude: 40°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gdlb) 35.3 -44.1 Dry bulb (OF) -2 93 Infiltration: Dailyrange (OF) - 35 (H ) Method Detailed Wet bulb CF) - 59 Shielding 3 (partial) Wind speed (mph) 15.0 7.5 Stories 1 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain 1t2 Bhhff--"F iF--°FM h Bbhffl Btuh Btu M Btuh Walls 12E-Osw: Frm wall, wd ext, 5/8" wood shth, r-19 cav ins, 2"x6" wood s 66 0.068 19.0 4.90 323 0.87 57 firm, 16" o.c. stud, r-1 int bd ins Partitions (none) Windows (none) Doors (none) Ceilings 18A-38md: Rf/cIg ceiling, mti roof mat, firm cons, 1 /2" gypsum board int 25 0.029 38.0 2.09 52 0.50 12 fish, 6" thkns, r-50 ceil ins Floors 19A-30cstp: Fir floor, firm fir, 12" thkns, r-30 cav ins, tight cirvnA ovr 25 0.034 30.0 2.05 51 0.51 13 +_1+ wrightsoft- 2025-Sep-1017:37:36 I Right-Sulte® Universal 2024 24.0.02 RSU59834 Page 11 ...b\OneDrive\Desktop\Load Calcs\540 Panoramic.rup Cale = MJ8 Front Door faces: E �raltl�w� Project Summary Entire House Mountain Air Mechanical I.V Y!1 fii..7:5? 601 W 2nd Street, Rifle. Cc 81650 Phone: 970-625-4352 Fax: 970-825-4356 Email: sar@mountainair.biz f ■ - ■ i For: Wells Residence 540 Panoramic Drive, Silt, CO 81652 Notes: Job: Date: Sep 10, 2025 By: Design • • Weather: Garfield Co Rgnl, CO, US Winter Design Conditions Summer Design Conditions Outside db -2 OF Outside db 93 OF Inside db 70 OF Inside db 75 OF Design TD 72 OF Design TD 18 OF Daily range H Relative humidity 50 % Ventilation Method MJ8 Moisture difference -44 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 19122 Btuh Structure 14993 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 19122 Btuh Use manufacturer's data n Infiltration Rate/swing multiplier Equipmenf sensible load 0.98 14649 Btuh Method Detailed Latent Cooling Equipment Load Sizing Shielding 3 (partial) Stories 1 Structure 600 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling Area (ft2) 1127 1121 Equipment latent load 600 Btuh Volume 15384 15384 Air changes/hour 0 0 Equipment Total Load (Sen+Lat) 15249 Btuh Equiv. AVF (cfm) 0 0 Req. total capacity at 0.70 SHR 1.7 ton Heating Equipment Summary Cooling Equipment Summary Make Mitsubishi Electric Make Mitsubishi Electric Trade Mitsubishi Electric Trade Mitsubishi Electric Model MXZ-3C24NAHZ4*** Cond MXZ-3C24NAHZ4*** AHRI ref 209847184 Coil AHRI ref 209847184 Efficiency 9.25 HSPF2 Efficiency 11.8 EER2,17.25 SEER2 Heating input Sensible cooling 15960 Btuh Heating output 24800 Btuh @47°F Latent cooling 6840 Btuh Temperature rise 36 °F Total cooling 22800 Btuh Actual air flow 760 cfm Actual air flow 760 elm Air flow factor 0.040 cfm/Btuh Air flow factor 0.051 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.96 Ca pacity ba lance point= 11 °F Backup: Input = 6 kW, Output = 19122 Btuh, 100 AFUE Sold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ep a 202&Sl017:37:36 ' wrigFxtsofC Right-Suite®Universal 2024 24.0.02 RSU59634 Page 1 ...bl0neprive%Desktop\Load Calcs\540 Panoramlc.rup Cale = MA Front Door faces: E Nl- '�+�--m:= i�i LAED Assessment Entire House i47q 625.41t Mountain Air Mechanical 601 W 2nd Street, Rifle, Co 81650 Phone: 970-625-4352 Fax: 970-625.4356 Email: sar@mountainair.biz For: Wells Residence 540 Panoramic Drive, Silt, CO 81652 7P_Sinn Conditic Job: Date: Sep 10, 2025 By: Location: Indoor: Heating Cooling Garfield Co Rgnl, CO, US Indoor temperature (T) 70 75 Elevation: 5545 ft Design TD (TF) 72 18 Latitude: 40ON Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gdlb) 35.3 -44.1 Dry bulb (T) -2 93 Infiltration: Dailyrange (T) - 35 ( H ) Wet bu lb (° F) - 59 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Diversity - .... _ u —I L,-- —4f— iI 15 16 17 18 19 X FCird DJ Houdy Awmge Maximum hourly glazing load exceeds average by 26.1%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh Bold4tallc values have been manually overridden lwrighlsoW 2025-Sep-1017:37:36 Right -Suite® Universal 2024 24.0.02 RSU59834 Page 1 10e8k ...b\OneDrlveXDesktoplLoad Calcs\540 Panoramic.rup Calc = MA Front Door faces: E Right-M Worksheet Job: Entire House Date: Sep 10, 2025 V-A G- Mountain Air Mechanical r.rtf rnr 9.,n co--f Ring r.n Fat rrin Phnne- 970-s25-4352 Fax: 970-625-4356 Email: sar(Wmountaineir.biz 1 Room name Entire House Bedrooml 2 Exposed wall 141.0 ft 26.5 ft 3 Room height 13.7 ft 15.0 ft heat/cool 4 Room dimensions 14.0 x 12.5 ft 5 Room area 1127.0 ft' 175.0 ft' Ty Construction U-value Or I HTM 1 Area (ft') Load Area (ft') Load number (Btuh/ftk°F (Btuh/ft2 f or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 Vt! 12E-Osw 0.068 n 4.90 0.87 336 302 1480 263 210 188 918 163 E—C 1D-c2ow 0.300 n 21.60 11.13 34 0 729 376 23 0 486 250 1/I1 12E-Osw 0.068 a 4.90 0.87 690 474 2321 413 188 134 654 116 L--' 1D-c2ow 0.300 a 21.60 33.64 216 0 4666 7267 54 0 1166 1817 VI/ 11 12E-Osw 0.068 s 4.90 0.87 330 308 1506 268 0 0 0 0 I___C 1 D-c2ow 0.300 s 21.60 17.46 23 0 486 393 0 0 0 0 12E-0sw 0.068 w 4.90 0.87 552 518 2537 451 0 0 0 0 1 D-c2ow 0.300 w 21.60 33.64 34 0 729 1135 0 0 0 0 C 16A-38md 0.029 2.09 0.50 1127 1127 2353 569 175 175 365 88 F 19A-30cstp 0.034 2.05 0.61 1127 1127 2315 569 175 175 360 88 6 c) AED excursion 0 1 1 -115 Envelope losstgain 1 19122 11703 1 1 3949 2409 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 3 690 2 460 Appliances/other 2600 0 Subtotal (lines 6 to 13) 19122 14993 3949 2869 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 19122 14993 3949 2869 15 Dud loads 0% 0% 0 0 -0% 0% 01 0 TotI room loadrequired 1976 1477601 3157 2869I Airal (clm) I I I 1 is Calculations amoroved by ACCA to eet al) requirements of Manual J 8th Ed. { ' wrlg►�tso7t 2025-Sep-1017:37:36 - Right -Suite® Universal 202424.0.02 RSU598M Page l ...b%OneDrivetDesktop\Load Calcs1540 Panoramic.rup Calc = MJ8 Front Door faces: E Right-J® Worksheet Job: PU.NTNN A�� �Date: Sep 10, 2025 = Entire House By: Mountain Air Mechanical 601 W 2nd Street. Rifle. Co 81650 Phone: 970-625-4352 Fax: 970-625-4356 Email: sar@mountainair.biz 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Bathl 16.5 ft 12.0 ft heaUcool 10.5 x 6.0 ft 63.0 ft2 WIC1 6.5 ft 12.0 ft heat/cool 10.5 x 6.5 ft 68.3 ft' Ty ConsWction number U-value (Btuh/ftz'F Or I HTM (Btuh/ft2) Area (ft.) or perimeter (ft) I Load (Btuh) I Area (ft') or perimeter (ft) 1 Load (Btuh) Heat Cool Gross I N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 yJ L—(^ 12E-Osw 1 Dc2ow 12E-Osw 1 Dc2ow 12E-Osw 1 D-c2ow 12E-0sw 1 Dc2ow 18A-3Bmd 19A-30cstp 0.068 0.300 0.068 0.300 0.068 0.300 0.068 0.300 0.029 0.034 n n a a s s w w 4.90 21.60 4.90 21.60 4.90 21.60 4.90 21.60 2.09 2.05 0.87 11.13 0.87 33.64 0.87 17.46 0.87 33.64 0.50 0.51 126 11 0 0 0 0 72 0 63 63 115 0 0 0 0 0 72 0 63 63 562 243 0 0 0 0 353 0 132 129 100 125 0 0 0 0 63 0 32 32 0 0 0 0 0 0 78 0 68 68 0 0 0 0 0 0 78 0 66 68 0 0 0 0 0 0 382 0 143 140 0 0 0 0 0 0 68 0 34 34 V+! r G V�/ L—( V�/ —G C F 6j c) AED excursion -26 -10 Envelope loss/gain 1418 325 665 127 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 0 0 Subtotal (lines 6 to 13) 1418 325 665 127 Less extema) toad 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1410 325 665 127 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 l room I ad Totarequired 14561 3161 665 126� Air (cfrn) I I I Calculations anoroved b ACCA to meet all requirements of Manual J 8th Ed- _ --H - wrAgf�tsoTi- 2025-Sep-1017:37:36 Rig ht-Suite® U niv ersal 2024 24.0.02 RSU59834 Page 2 ...b\OneDrive\Desktop\Load Calcs\540 Panoramic.rup Calc = MJ8 Front Door faces: E Right-M Worksheet Job: Entire House Date: Sep 70, 2025 By Mountain Air Mechanical Rn1 w 2nd Street- Rifle- Co 81650 Phone: 970-625-4352 Fax: 970-625-4356 Email: sar@mountainair.biz 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Kitchen 21.5 ft 12.0 ft heat/cool 10.5 x 21.5 ft 225.8 fts Living 21.5 ft 15.0 ft heat/cool 14.0 x 21.5 ft 301.0 ft' Ty ion U-value (Btuh/ft{'F Or HTM I (Btuh/ft� Area (W) I or perimeter (ft) Load I (Btuh) Area (ft') I or perimeter (ft) lLoad I (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool Lnb.," 6 11 V�I i G 12E-Osw 1 D-c2ow 12E-Osw 1 Dc2ow 12E-Osw 1 Dc2ow 12E-Osw 1 D-c2ow 18A-38md 19A-30cstp 0.068 0.300 0.068 0.300 0.068 0.300 0.068 0.300 0.029 0.034 n n a a s s w w - 4.90 21.60 4.90 21.60 4.90 21.60 4.90 21.60 2.09 2.05 0.87 11.13 0.87 33.64 0.87 17.46 0.87 33.64 0.50 0.51 0 D ❑ 0 0 0 258 34 226 226 0 0 0 0 0 0 224 0 226 226 0 0 0 0 0 0 1098 729 471 464 0 0 0 0 0 0 195 1135 114 114 0 0 323 108 0 0 0 0 301 301 0 0 215 0 0 0 0 0 301 301 0 0 1050 2333 0 0 0 0 628 618 0 0 187 3634 0 0 0 0 152 152 yJ L—G t-G C F 61 c) AED excursion I 1 1 3351 1 197 Envelope loss/gain 1 2762 1894 1 11 4630 4221 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 ❑ 13 Internal gains: Occupants (d1 230 0 0 0 0 Appliancestother 1200 900 Subtotal (lines 6 to 13) 2762 3094 4630 5121 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2762 3094 4630 5121 15 Duct loads -0% 0% 0 0 -0%1 0%I 0 0 rrreqcored 2'621 30941 46301 121] 5260 (ad Air I 10 157I 1 Calculations aooroved by ACCA to meet aA requirements of Manual J 8th Ed- -4- w Ault-14- 2025-Sep-1017:37:36 - - Right-Sufte®Universal 202424.0.02RSU59834 Page b\OneDrive\Desktop\Load Calcs\540 Panoramic.rup Calc = MJ8 Front Door faces: E Right-M Worksheet Job: C7UTIT/.tN AIR Date: Sep 10, 2025 Entire House By: Mountain Air Mechanical 601 W 2nd Street Rifle. Co 81650 Phone: 970-625-4352 Fax: 970-625-4356 Email: sar@mountaineir.biz 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Bedroom2 24.0 ft 15.0 It heat/cool 12.0 x 12.0 ft 144.0 ft' Laundry 7.5 ft 12.0 ft heat/cool 7.0 x 7.5 It 52.5 ft' Ty Construction number U-value (Btuh/Wt - F Or HTM (Btuh/ft2 Area (W) I or perimeter (ft) I Load 1 (Btuh) Area (ft-) or perimeter (ft) I Load l (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 V►/ I- 12E-0sw 1 D-c2ow 12E-Osw 1Dc2ow 12E-Osw 1 D-c2ow 12E-Osw 1 D-c2ow 1 BA-38md 19A-30cstp 0.068 0.300 0.068 0.300 0.068 0.300 0.068 0.300 0.029 0.034 n n a a s s w w 4.90 21.60 4.90 21.60 4.90 21.60 4.90 21.60 2.09 2.05 0.87 11.13 0.87 33.64 0.87 17.46 0.87 33.64 0.50 0.51 0 0 180 54 180 23 0 0 144 144 0 0 126 0 158 0 0 0 144 144 0 0 617 1166 771 486 0 0 301 296 0 0 110 1817 137 393 0 0 73 73 0 0 0 0 0 0 90 0 53 53 0 0 0 0 0 0 90 0 53 53 0 0 0 0 0 0 441 0 110 108 0 0 0 0 0 0 78 0 26 27 -G I-C V// L.-G C F 61 c) AED excursion -213 -47 Envelope loss/gain 1 3637 2389 1 656 84 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants C 230 1 230 0 0 Appliances/other 0 500 Subtotal (lines 6 to 13) 3637 26191 658 584 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3637 2619 658 584 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Totarequired om 314551 263 6 5 f Air (cfm) f 6 0� Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed. }r w� rgtitssatt- 2025-Sep-1017:37:36 -- Right-SulteOUniversal 202424.0.02RSU59834 Page b\OneDrive\Desktop\Load Calcs\540 Panoramic.rup Calc = MJ8 Front Door faces: E ■Allilibb" Right-M Worksheet Job: „ Entire House Date: Sep 10, 2025 k Mountain Air Mechanical 601 W 2nd Street, Rifle, Co 81650 Phone: 970-625-4352 Fax: 970-625-4356 Email: sar@mountainair.biz 1 Room name MECH Bathroom2 2 3 Exposed wall Room height 11.5 ft 12.0 ft heat/cool 0 ft 12.0 It heat/cool 4 5 Room dimensions Room area 7.0 x 4.5 ft 31.5 ft' 5.5 x 7.5 ft 41.3 ft' Ty Construction number U-value (Btuh/ft'-°F Or HTM I (Btuh/ft2) Area ft' or perimeter (ft) Load I (Btuh) Area (ft') or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 V l--G 12E-Osw 1D-c2ow 12E-Osw 1 D-c2ow 12E-Osw 1Dc2ow 12E-Osw 1 Dc2ow 1BA-38md 0.068 0.300 0.068 0.300 0.068 0.300 0.068 0.300 0.029 n n a a s s w w 4.90 21.60 4.90 21.60 4.90 21.60 4.90 21.60 2.09 0.87 11.13 0.87 33.64 0.87 17.46 0.87 33.64 0,50 0 0 0 0 84 0 54 0 32 0 0 0 0 84 0 54 0 32 0 0 0 0 411 0 264 0 66 0 0 0 0 73 (1 47 0 16 0 0 0 0 0 0 0 0 41 0 0 0 0 0 0 0 0 41 0 0 0 0 0 0 0 0 86 0 0 0 0 0 0 0 0 21 V)! L—.G V)/ L—G V+l G C F 19A-30cstp 0.034 2.05 0.51 32 32 65 16 41 41 85 21 61 c) AED excursion 1 } _3 Envelope loss/gain 1 806 140 1 171 39 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 806 1401 171 39 Leas external load 0 0 0 0 Less transfer 0 0 0 0 14 Redistribution Subtotal 0 806 0 140 0 171 0 39 15 Dud loads -0% 0% 0 0 -0% 0% 0 0 Total room load 806 140 171 39 Air required (cfrn) 32 7 1 1 7 2 Calculations approved by ACCA 19 mgpt all re uirements of Manual J 8th Ed. _+ wr�gAtxraTt ' 2025-Sep-1017:37:36 Right -Suite® Universal 2024 24.0.02 RSU59834 Page 5 ...b\OneDrive0esktoplLoad CalcsXM0 Panoramic.rup Celc = MJB Front Door faces: E A.hRight-M WorkshEntire House eet Job: �� Date: Sep 70, 2025 v.� - ..... By: Mountain Air Mechanical 601 W 2nd Street Rifle. Co 81650 Phone: 970-625-4352 Fax: 970-625-4356 Email: sar@mountainair.biz 1 Room name WIC2 2 3 Exposed wall Room height 5.5 ft 12.0 ft heat/cool 4 Room dimensions 5.5 x 4.5 ft 5 Room area 24.8 ft' Ty Construction number U-value (Btuh/ft;°F Or HTM I (Btuh/ft� Area (W) or perimeter (It Load I (Stub) Area or perimeter I Load Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool — 6 W G 12E-Osw 1 D-c2ow 12E-0sw 0.068 0.300 0.068 n n a 4.90 21.60 4.90 0.B7 11 A 3 0.87 0 0 0 0 0 0 0 0 0 0 0 0 V+I 11 I---G 1 D-c2ow 12E-0sw 0.300 0.068 a s 21.60 4.90 33.64 0.87 0 66 0 66 0 323 0 57 v�J t—{, 1 Dc2ow 12E-0sw 1D-c2ow 0.300 O.068 0.300 s w w 21.60 4.90 21.60 17.46 0.87 33.64 0 0 0 0 0 0 0 0 0 0 0 0 V/! L---G C 18A-38md 0.029 2.09 0.50 25 25 52 12 F 19A-30cstp 0.034 2.05 0.51 25 25 51 13 6 c) AED excursion 6 Envelope lossigain 1 426 76 12 a) Infiltration 0 0 b) Room ventilation 0 0 13 Internal gains: Occupants 230 0 0 Appliances/other 1 0 Subtotal (lines 6 to 13) 1 426 76 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 426 76 15 Duct loads -0% 0% 0 0 Total room load 426 76 Air required (rim) 17 4 C�alailatio_ns anamed_by ACCA to meet all_reauirements of Manual J 8th Ed. -4k- wrlgl atx4aTC 2025-Sep-1017:37:36 Rig ht-Suite® Universal 2024 24.0.02 RSU59834 Page 6 b1One0dve%DesktopM_oed CaIcs1540 Panoramic.rup Cal;; = MA Front Door faces: E Right-.JB® Form J1 Job: A!N AIR Date: Sep 10, 2025 Entire House By: Mountain Air Mechanical err W 7nd Street. Rifle. Co 81650 Phone: 970-625-4352 Fax: 970-625-4356 Email: sar@mountainair.biz 1 2 3 4 5 Name of Room Running Feet of Exposed Wag Ceiling Ht (Ft) and Gross Wall Area (SgFQ Room Dimensions (Ft) and Floor Plan Area (SgFt) Ceiling Slope (Deg.) and Gross Ceiling Area (SgFt) Entire House 141.0 ft 13.7 ft 5344.7 ft' 1127.0 ft' 0 1127.0 ft' Bedrooml 26.5 ft 15.0 ft 795.0 ft' 14.0 x 12.5 ft 175.0 ft' 0 175.0 ft' Type of Const.• Panel i I HTM I Area or I Btuh Area or Btuh Exposure Number Faces Clg. Length Heating S-Clg L-Ctg LengthHtg. Heating S-Clg L-Clg 6 11 YKall laz II laz V�1all Claz a1/+/ II laz Ceil Flor 12E-Osw 1D-c2ow 12E-Osw 1D-c2ow 12E-osw 1 Dc2ow 12E-Osw 1 D-c2ow 18A-38md 19A-30cstp n n a a s s v w 4.90 21.80 4.90 21.60 4.90 21.60 4.90 21.60 2.09 2.05 0.87 11.13 0.87 33.64 0.87 17.46 0.87 33.64 0.50 0.51 336 34 690 216 330 23 552 34 1127 1127 1480 729 2321 4666 1506 486 2537 729 2353 2315 263 376 413 7267 268 393 451 1135 569 569 210 23 188 54 0 0 0 0 175 175 918 486 654 1166 0 0 0 0 365 360 163 250 116 1817 0 0 0 0 88 88 Infiltration Heating Load (Btuh) 0 0 0 Effect WAR WAR 12 Sensible Load (Btuh) ACH 1.00 I 0 I I 0 I 0' 0 r Latent Load (Btuh) 0 Internal a Occupants at 230 and 200 Btuh 3 690 600 2 460 400 b Scenario number 2600 0 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines 6 through 12 1 1 19122 1 14993 600 3949 1 2869 Duct EHLF & ESGF 01 1 0 1 0 0 1 0 15 Loads ELG 0 0 16 Ventilation Loads Vent Cfm 0 E Cfm 0 0 0 0 17 I Winter Humidification Load Gal/Day I 0 0 18 Piping Load { 0 19 Blower Heat 0 20 AED Excursion & Latent Moisture Migration Load 0 -115 21 Total Load Sum lines 13 through 19 19122 14993 600 3949 2869 Calculations ap proved by ACCA to meet al! re uirements of Manual J 8th Ed- -4 --aspomir tt- 2025-Sep-1017:37:37 A Rig ht-Suite® Universal 2024 24.0.02 RSU59834 Page 1 b\OneDrive\Desktop\Load Calcs\540 Penoramic.rup Calc = MJ8 Front Door faces: E Right-J8® Form J1 Job: Entire House Date: Sep 10, 2025 - By: Mountain Air Mechanical 601 W 2nd Street Rifie, Co 81650 Phone: 970-625-4352 Fax: 970-625-4356 Email: sar@mountainair.biz 1 Name of Room Bath1 WIC1 2 3 Running Feet of Exposed Wall Ceiling Ht (Ft) and Gross Wall Area (SgFt) 16.5 ft 12.0 ft 396.0 ft2 6.5 ft 12.0 ft 408.0 ft' 4 Room Dimensions (Ft) and Floor Plan Area (SgFt) 10.5 x 6.0 ft 63.0 ft2 10.5 x 6.5 ft 68.3 ft2 5 Ceiling Slope (Deg.) and Gross Ceiling Area (SgFQ 0 63.0 ft' 0 68.3 ft2 f ` Type of Const., Panel I HTM I Area or Btuh Area or I Btuh Exposure Number Faces Length Length H(g. Clg. Heating S-Clg L-Clg Healing SCIg L-Clg 6 eff12E-0sw n 4.90 0.87 126 562 100 0 0 0 laz 1D-c2ow n 21.60 11.13 11 243 125 0 0 0 all 12E-Osw a 4.90 0.87 0 0 0 0 0 0 laz 1Dc2ow a 21.60 33.64 0 0 0 0 0 0 11 VELlaz 12E-0sw s 4.90 0.87 0 0 0 0 0 0 1 D-c2ow s 21.60 17.46 0 0 0 0 0 0 V�/a1I 12E-0sw w 4.90 0.87 72 353 63 78 382 68 �Glaz 1D-c2ow w 21.60 33.64 0 0 0 0 0 0 Cell 18A-38md 2.09 0.50 63 132 32 68 143 34 Flor 19A-30cstp 2.05 0.51 63 129 32 68 140 34 Infiltration Heating Load (Btuh) 0 0 0 Effect WAR WAR 12 I Sensible Load (Btuh) I ACH 0 I 0 0 0 j 0 Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 0 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 1 Subtotals Sum lines 6 through 12 1 1 1418 1 325 665 ��127 Duct EHLF & ESGF 0 0 0 0 0 0 15 Loads ELG 0 0 16 Ventilation Loads Vent Cfm 0 E Cfm 0 17 Winter Humidification Load Gal/Day 0 18 Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load -26 -10 21 Total Load Sum lines 13 through 19 1418 325 665 127 Calculations atwiroved ACCA to meet all re uirements of Manual J 8th Ed. -14- wa igltracat! 2025-Sep-1017:37:37 �� Right -Suite® Universal 2024 24.0.02 RSU59834 Page MOneLlrive%Desktap%Load Caics1540 Penoramic.rup Calc � MJ8 Front Door faces: E Right-J88 Form J1 Job: �= Entire House Date: Sep 10, 2025 v.Ac By: Mountain Air Mechanical 9nt w 9nd Street_ Rifle- Co 81650 Phone: 970-6254352 Fax: 970-625-4366 Email: sar(Mmountainair.biz 1 21 31 4 5 Name of Room Running Feet of Exposed Wall Ceiling Ht (Ft) and Gross Wall Area (SgFt) Room Dimensions (Ft) and Floor Plan Area (SgFQ Ceiling Slope (Deg.) and Gross Ceiling Area (SgFt) Kitchen 21.5 ft 12.0 ft 768.0 ft' 10.5 x 21.5 ft 225.8 ft2 0 225.8 ft' Living 21.5 ft 15.0 ft 1065.0 ft' 14.0 x 21.5 ft 301.0 f t' 0 301.0 ft' Type of Const., Panel I HTM Area or f ` Btuh I Area or Btuh Exposure Number Faces Length Length Hig. Clg. Heating S-Clg L-Clg Healing S-Clg L-Clg 6 11 ylall laz �II laz V+/all L-f laz V►/all !- laz Ceil Flor 12E-0sw 1Dc2ow 12E-0sw 1D-c2ow 12E-Osw 1 D-c2ow 12E-0sw 1Dc2ow IBA-38md 19A-30cstp n n a a s s w w 4.90 21.60 4.90 21.60 4.90 21.60 4.90 21.60 2.09 2.05 0.87 11.13 0.87 33.64 0.87 17.46 0.87 33.64 0.50 0.51 0 0 0 0 0 0 258 34 226 226 0 0 0 0 0 0 1098 729 471 464 0 0 0 0 0 0 195 1135 114 114 0 0 323 108 0 0 0 0 301 301 0 0 1050 2333 0 0 0 0 628 618 0 0 187 3634 0 0 0 0 152 152 Infiltration Heating Load (Btuh) 0 0 0 Effect WAR WAR 12 LSensibfe Load (Btuh) - ACH 0 0! 0 I I 0 0 I` Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh ❑ 0 0 Cl 0 0 b Scenario number 1200 9 00 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 i 14 Subtotals Sum lines 6 through 12 1 1 2762 3094 ! 4630 5121 Duct EHLF 6 ESGF I 0 0 0 0 0 0 15 Loads ELG 0 0 16 Ventilation Loads Vent Cfm 0 E Cfm 0 17 Winter Humidification Load Gal/Day 10 18 j Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load 335 97 21 Total Load Sum lines 13 through 19 2762 3094 4630 5121 Calculations awroved by ACCA to meet ail re_ mrements of Manual J 8th Ed. f�F wrlgF`tso7t- 2025-Sep-1017:37:37 Rig ht-Suite® Universal 2024 24.0.02 RSU59834 Page 3Load Calc ...b\OneDdve\Desktop\s\540 Panoramic.rup Calc = MJB Front Door faces: E ��4 Right-J88 Form J1 Job: F- "- Entire House Date: Sep 10, 2025 ..�- By: Mountain Air Mechanical 601 W 2nd Street. Rifle. Co 81650 Phone: 970-625-4352 Fax: 970-6254356 Email: sar@mountainair.biz 1 Name of Room Bedroom2 Laundry 2 Running Feet of Exposed Wall 24.0 ft 7.5 ft 3 Ceiling Ht (Ft) and Gross Wall Area (SgFt) 15.0 ft 720.0 ft' 12.0 ft 348.0 ft' 4 Room Dimensions (Ft) and Floor Plan Area (SgFt) 12.0 x 12.0 ft 144.0 ft' TO x 7.5 ft 52.5 ft2 5 Ceiling Slope (Deg.) and Gross Ceiling Area (SgFt) 0 144.0 ft' 0 52.5 ft' Type of Const., Panel I HTM Area or I Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 II 12E-Osw n 4.90 0.87 0 0 0 0 0 0 laz 1D-c2ow n 21.60 11.13 0 0 0 0 0 0 a1/I/ II 12E-0sw a 4.90 0.87 180 617 110 0 0 0 laz 1D-c2ow a 21.60 33.64 54 1166 1817 0 0 0 11 aVl/ II 12E-Osw s 4.90 0.87 180 771 137 0 0 0 �Glaz 1D-c20ow s 21.60 17.46 23 486 393 0 0 0 1ya11 12E-Osw w 4.90 0.87 0 0 0 90 441 78 U -Glaz 1D-c2ow w 21.60 33.64 0 0 0 0 0 0 Ceil 18A-38md 2.09 0.50 144 301 73 53 110 26 Flor 19A-30cstp 2.05 0.51 144 296 73 53 108 27 Infiltration Heating Load (Btuh) 0 0 0 Effect WAR WAR 12 Sensible Load (Btuh) I ACH 0 I 0 I I 0 I 0 I h 0 1' !� Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 1 230 200 0 0 0 b Scenario number 0 500 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 LL41 Subtotals Sum lines 6 through 12 3637 2619 658 5" Duct EHLF & ESGF 101 0 1 0 1 0 1 1 0 1 0 15 Loads ELG 0 0 II 16 Ventilation Loads Vent Cfm 0 1 E Cfm 0 17 Winter Humidification Load Gal/Day 0 18 j Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load -213 -47 21 Total Load Sum lines 13 through 19 3637 2619 656 584 Calculations approved by ACCA tp meetall re uirements of Manual J 8th Ed. + 2025-Sep-1017:37:37 Rig ht-Su ite®Universal 2024 24.0.02 RSU59834 -'c'A b%OneDrivetDesktop\Load CalcsX540 Panoramic.rup Calc = MJ8 Front Door faces: E Page 4 A-m�+ *Right,J80 Form J1 Job: "" Entire House Date: Sep 10, 2026 1I W y�// B7' Mountain Air Mechanical ent VV 2nd Street. Rifle. Co 81650 Phone: 970-625-4352 Fax: 970-625-4356 Email: sargmountainair.biz 1 Name of Room MECH Bathroom2 2 Running Feet of Exposed Wall 11.5 ft 0 ft 3 Ceiling Ht (Ft) and Gross Wall Area (SgFt) 12.0 ft 276.0 ft2 12.0 ft 312.0 f t' 4 Room Dimensions (Ft) and Floor Plan Area (SgFQ 7.0 x 4.5 ft 31.5 ft' 5.5 x 7.5 ft 41.3 ft' 5 Ceiling Slope (Deg.) and Gross Ceiling Area (SgFQ 0 31.5 ft' 0 41.3 ft' Type of Const., Panel HTM V I Area or Btuh I Area or I Btuh Exposure Number Faces Length Length Htg Clg Heating S Clg L-Clg Heating S-Clg L-Clg 6 It!12E-Osw n 4.90 0.87 0 0 0 0 0 0 laz i D-c2ow n 21.60 11.13 0 0 0 0 0 0 II 12E-09w a 4.90 0.87 0 0 0 0 0 0 laz 1 D-c2ow a 21.60 33.64 0 0 0 0 0 0 11 aV+! II 12E-0sw s 4.90 0.87 84 411 73 0 0 0 LGlaz 1D-c2ow s 21.60 17.46 0 0 0 0 0 0 Vj/all 12E-Ow w 4.90 0.87 54 264 47 0 0 0 LGlaz 1D-c2ow w 21.60 33.64 0 0 0 0 0 0 Cell 18A-38md 2.09 0.50 32 66 16 41 86 21 Flor 19A-30cstp 2.05 0.51 32 65 16 41 85 21 Infiltration Heating Load (Btuh) 0 0 0 Effect WAR WAR 12 Sensible Load (Btuh) J ACH 0 1 0 I I 0 0 Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 0 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 1 0 1 0 14 Subtotals V Sum lines 6 through 12 I 806 I 140 1 1 I 171 I 39 - Duct - EHLF & ESGF 01 01 1 0 0 1 0 1 0 15 Loads ELG 0 0 16 Ventilation Loads Vent Cfm 0 E Cfm 0 17 Winter Humidification Load Gal/Day 0 18 Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load -11 -3 21 Total Load Sum lines 13 through 19 806 140 171 39 w Calculations wDroved by ACCA to meet all re-Quirements_of Manual J 8th Ed _ wrrgAtsof� 2025-Sep-1017:37:37 •. Right-Sulte® Universal 2024 24.0.02 RSU59834 Page 5 b1OneDdveM)esklopM-oad Calcst540 Panoramic.rup Calc = MJ8 Front Door faces: E Right-J80 Form J1 Job: &A ERR �_., q Entire House Date: Sep 10, 2025 ., VJ C. By: Mountain Air Mechanical 601 W 2nd Street. Rifle. Co 81650 Phone: 970-625-4352 Fax: 970-625-4356 Email: sar@mountainair.biz 1 Name of Room VVIC2 2 Running Feet of Exposed Wall 5.5 ft 3 Ceiling Ht (Ft) and Gross Wall Area (SgFt) 12.0 ft 240.0 ft' 4 Room Dimensions (Ft) and Floor Plan Area (SgFQ 5.5 x 4.5 ft 24.8 ft' 5 Ceiling Slope (Deg.) and Gross Ceiling Area (SgFt) 0 24.8 ft2 i Type of Const., Panel HTM Area or Btuh Area or ` Btuh Exposure Number Faces Length Length Htg. Clg. Heating S Clg L-Clg Healing S Clg L-Clg 6 Vff12E-Osw n 4.90 0.87 0 0 0 laz 1D-c2ow n 21.60 11.13 0 0 0 all 12E-Osw a 4.90 0.87 0 0 0 laz 1 Dc2ow a 21.60 33.64 0 0 0 11 aV+/ 11 12E-Osw s 4.90 0.87 66 323 57 lez 1D-c2ow s 21.60 17.46 0 0 0 V)/a II 12E-0sw w 4.90 0.87 0 0 0 Gdaz 1Dc2ow w 21.60 33.64 0 0 0 Cell 18A-38md 2.09 0.50 25 52 12 Flor 19A-30cstp 2.05 0.51 25 51 13 Infiltration Heating Load (Btuh) 0 0 Effect WAR 12 I Sensible Load (Btuh) J ACH 0 I 0 Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 b Scenario number 0 13 c Default Adjustments d Custom Appliances 0 0 e Plants 0 14 Subtotals Sum lines 6 through 12 426 1 76 i Dud EHLF & ESGF 0 0 0 0 15 Loads ELG 0 Fd Ventilation Loads Vent Cfm 0 E Cfm 0 17 Winter Humidification Load Gal/Day 0 18 Piping Load 19 Blawer Heat 20 AED Excursion & Latent Moisture Migration Load -6 21 Total Load Sum Imes 13 through 19 426 1 76 Calculations approved by ACCA to meet all re uirements of Manual J 8th Ed, t wr�gtitsoYt 2025-Sep-1017:37:37 Rig ht-Suite® Universal 2024 24.0.02 RSU59834 Page 6 ...b\OneDrive\Desktop\Load Calcs\540 Panoramic.rup Calc = MJ8 Front Doorfaces: E .�. Loads for Multiple Orientations Job: tR P Date: Sep 10, 2025 _ . Entire House By: Mountain Air Mechanical 601 W 2nd Street, Rlfle, Co 81650 Phone: 970-625-4352 Fax: 970-625-4356 Email: sar@mountainair.biz For: Wells Residence 540 Panoramic Drive, Silt, CO 81652 Location: Garfield Co Rgnl, CO, US Elevation: 5545 ft Latitude: 40°N Outdoor: Heating Dry bulb (°F) -2 Dailyrange (°F) - Wet bulb (° F) - Wind speed (mph) 15.0 Indoor: Heating Cooling Indoor temperature (OF) 70 75 Design TD (OF) 72 18 Relative humidity (%) 30 50 Cooling Moisture difference (grAb) 35.3 -44.1 93 Infiltration: 35 ( H ) 59 7.5 Front Door North Northeast East Southeast South Southwest West Northwest Sensible Load (Btuh) 10462 13127 14649 13995 12111 15965 17511 14848 Latent Load (Btuh) 600 600 600 600 600 600 600 600 Total Load (Btuh) 11062 13727 15249 14595 12711 16565 18111 15448 Heating AVF (cfm) 760 760 760 760 760 760 760 760 Cooling AVF (cfm) 760 760 760 760 760 760 760 760 Ekildirg Oientafrion Coding road 20000r- 0 i -- N NE E SE S SVV W MN ❑re bmRvtDxr&w Current Orientation: Front Door faces East Highest Cooling Load: Front Door faces West Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. W rights aft 2025-Sep-1017:37:37 —1„ Rig ht-Suite® Universal 2024 24.0.02 RSU59834 Page 1 b\OneDdve%DesktopkLoad Calcs\540 Panoramic.rup Calc = MJS Front Door faces: E A Form - Worksheet A Job: Date: Sep 10, 2025 Entire House By: Mountain Air Mechanical 601 W 2nd Street, Rifle, Co 81650 Phone: 970-6254352 Fax: 970-625-4356 Email: sar@mountainair.biz Supporting Detail Project Name: 540 Panoramic Date: Sep 10, 2025 Address: 540 Panoramic Drive, Silt, CO 81652 Phone: Job ID: Worksheet A Location and Design Conditions Weather Location: Garfield Co Rgnl, CO, US Elevation = 554. Latitude = 40 Indoor Conditions, Heating: DB = 70 °F RH = 30 % Indoor Conditions, Cooling: DB = 75 °F RH = 50 % Table 1 Conditions 99% DB = -2 °F 1% DB = 93 °F Grains Difference = -44 grAb Daily Range = H Design Temperature Differences HTD = 72 °F CTD = 18 °F Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. W riigh is o f t - 2025-Sep-1017:37:37 ,..., Right -Suite® Universal 202424.0.02 RSU59834 Page 1 b\OneDdve\Desktop\Load Calcs\540 Panoramic.rup Calc = MJ8 Front Door faces: E , Detailed Infiltration Report ' Entire House (-',A;�= Mountain Air Mechanical Job: Date: Sep 10, 2025 By: 601 W 2nd Street, Rifle, Co 81650 Phone: 970-625-4352 Fax: 970-625-4356 Email: sar@mountainair.biz Step 1: Leakage Area Calculations Component Quality Leakage factor Area/Count Leakage area (in') Cool .ieat Cool Total 0 0 Step 2: Winter and Summer Factors Wind Exposure Number of stories Factors (clim/nz) Winter: 3 (partial) 1 0 Summer: 3 (partial) 1 0 Step 3: Infiltration AC/HR for Winter and Summer Leakage Infil. factor Min./ Door traffic Total Area (ink (cfmfin j (ft3 xhr.) (ach) (ach) Winter = ( 0 x 0 x 60 / 15384 ) + 0.10 = 0 Summer = ( 0 x 0 x 60 / 15384 } + 0.10 = 0 Summary Cooling Conditioned floor area 1127 ftz 1127 itz Above grade volume 15384 f13 15384 ft3 Air change rate 0 ach 0 ach Unadjusted AVF 0 cfm 0 cfm Vent adjustment 0 cfm 0 cfm Net AVF 0 cfm 0 cfm Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wriigntsofY 2025-Sep-1017:37:37 Right-SuRe®Universal 202424.0.02 RSU59834 page 1 r?v b\OneDrive\DesktoplLoad Calcs1540 Panoramic.rup Calc = MJ8 Front Door faces: E Manual S Compliance Report Date: b:Sap 10, zozs A/ a �a Entire House By. :a-V.. t: Mountain Air Mechanical 601 W 2nd Street. Rifle, Co 81650 Phone: 970-625-4352 Fax: 970-625-4356 Email: sarCmountainair.biz i., For: Wells Residence 540 Panoramic Drive, Silt, CO 81652 Cooling Equipment Design Conditions Outdoor design DB: 92.70F Sensible gain: 14993 Btuh Entering coil DB: 75.0°F Outdoor design WB: 58.5°F Latent gain: 600 Btuh Entering coil WB: 61.6°F Indoor design DB: 75.WF Total gain: 15593 Btuh Indoor RH: 50% Estimated airflow: 760 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Manufacturer: Actual airflow: Sensible capacity: Latent capacity: Total capacity: Split ASHP Mitsubishi Electric 760 cfm 15960 Btuh 6840 Btuh 22800 Btuh Design Conditions Outdoor design DB: -2.0°F Indoor design DB: 70.0°F Model: MXZ-3C24NAHZ4""" 106% of load 11406 of load 146e/a of load SHR: 70% Heat loss: 19122 Btuh Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Mitsubishi Electric Model: MXZ-3C24NAHZ4" Actual airflow: 760 cfm Output capacity: 24800 Btuh 130% of load Supplemental heat required: 0 Btuh Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 760 cfm Output capacity: 5.6 kW 100% of load Temp. rise: 50 'F Meets all requirements of ACCA Manual S. Entering coil DB: 70.0°F Capacity balance: 11 °F Economic balance: -99 °F -.1 P- Wri9htsaft' 2025-Sep-1017:37:37 Right Suite®Universal 2024 24.0.02 RSU59834 Page 1 ...b\OneDrive\Desktop\Load Calcs\540 Panoramic rup Cale = MJ8 Front Door faces: E DHW Report N u�� Entire House Mountain Air Mechanical 601 W 2nd street, Rifle, Co 81650 Phone: 970-625-4352 Fax: 970-625-4356 Email: sar@mountainair.biz For: Wells Residence 540 Panoramic Drive, Silt, CO 81652 Job: Date: Sep 10, 2025 By: Design Occupants Not occupied during the day Age Number Dishwasher 0-5 0 Clothes washer 6-13 2 Additional use (gpd) 0 14-59 2 Setpoint (OF) 120 60+ 0 Daily use (gpd) 61 Manufacturer Tank size (gal) 40 Trade name Energy factor 0.60 Model Input (MBtuh) 0.0 AHRI ref. number 1 st hour (gal) 60 Recovery eff. (°Io) 77 2025-Sep-10 17:37:37 Right -Suite® Universal 202424.0.02 RSU59834 Page 1 ...b\OneDrive\Desktop\Load Calcs\540 Panoramic.rup Calc = MJ8 Front Door faces: E ACCK. Contractor Mechanical license# Building plan # Form RIPER 2.0 Garfield County, Colorado Header Information Mountain Air Mechanical Applicable Attachments Sarah Roper Manual A Form and Worksheet A: ❑ Yes ❑ No OEM performance data (heating, cooling, blower): ❑ Yes ❑ No Duct distribution sketch: ❑ Yes ❑ No IRC Table R301.2 (climate & geographic design criteria) ❑ Yes ❑ No Home address (Street or Lot#, Block, Subdivision) . 540-Panoramic Drive Entire House HVAC •.D CALCULATION (IRC M1401,61 Manual J Design -Criteria -and -Loads Location Summer Design -Conditions- Manual J Loads Elevation 5545 ft Outdoor Cooling Temp 93 °F Total Heat Loss 19122 Btuh Altitude Correction Factor 0.82 Indoor Cooling Temp 75 °F Latitude 40 °N Cooling Temp Diff 18 °F Sensible Heat Gain 14993 Btuh Indoor Summer Design RH 50 % Latent Head Gain 600 Btuh Wint"Design_Conditions Coincident Wet Bulb Temp 59 °F Total Heat Gain 15593 Btuh Outdoor Winter Temp -2 °F Indoor Winter Temp 70 °F Heating Temp Diff 72 °F The heat loss/gain was calculated in accordance with ACCA Manual J? Y■ N❑ EQUIPMENTHVAC SELECTION41 Heating Equipment Cooling -Equipment ❑ Furnace ❑ Boiler ■ Electric Heat ❑ Air Conditioner ■ Heat Pump ❑ Single Speed ❑ Multi Stage ❑ Modulating ■ Air -to -Air ❑ Geothermal Open Loop ❑ Geothermal Closed Loop ■ Single Speed ❑ Multi Stage ❑ Variable Speed Model Model Mxz-3C24NAHz4"'-'- Output 24800 Btuh Sizing Value 19122 Btuh Sensible 15960 Btuh Sizing Value 15593 Btuh Supplemental 0 Btuh Sizing Limit 175.0 % Latent 6840 Btuh Sizing Limit 115.0 % Heat Load: Capacity 100.0 % Total 22800 Btuh Load: Capacity 146.2 % Size Factor is within Manual S Size Limit? Y■ N❑ Size Factor is within Manual S Size Limit? Y❑ N■ HVAC DUCT DISTRIBUTION DESIGN •1 Design airnow 760 cfm Longest Supply Duct 0 ft Duct Materials Used External Static Pressure (ESP) 0 in H2O Longest Return Duct 0 ft Trunk Duct: ❑ Duct Board ❑ Sheet Metal Component Pressure Loss (CPL) 0 in H2O Total Effective Length (TEL) 0 ft ❑ Flex ❑ Lined Sheet Metal ❑ Other Available static pressure (ASP) 0 in H2O Friction Rate 0 in/100ft Branch Duct: ❑ Duct Board ■ Sheet Metal ESP— CPL = ASP (ASP x 100) / TEL = Friction Rate ❑ Flex ❑ Lined Sheet Metal ❑ Other Ducts are sized per Manual D? YN N❑ Contractor's printed name: Contractor's signature: Date: 4--P- wriphtsoft' .� -•- - �- - Righ[-Sulte®Universal 202424.0.02 RSU59834