Loading...
HomeMy WebLinkAboutResChecktz REScheck*Web TM Compliance Certificate Project Information Project Title: Energy Code: Location: Construction Type: Project Type: Project Sub Type: Orientation: Conditioned Floor Area: Glazing Area: Climate Zone: Project No: All Electric: Is Renewable: Has Battery: Has Charger: Has Heat Pump Construction Site: 672 ODIN DRIVE SILT, CO 81651 Project Notes: CUC - ODIN DRIVE 2018 IECC Garfield, Colorado Single Family New Construction None Bldg. faces 270 deg. from North 4399 ft2 12% 5b (8499 HDD) 1769002 true false false true false Owner/Agent: ERNESTO CUC 625 AIRPORT ROAD COKE OVENS 2 LLC GLENWOOD SPRINGS, CO 81601 9704042224 ER N E STO @CU CCO N STRU CTI O N. CO M Designer/Contractor: BRADJORDAN PO BOX 1031 JORDAN ARCHITECTURE GLENWOOD SPRINGS, CO 81602 9706186690 BRADJORDANARCHITECT@GMAIL.COM Report Title: CUC - ODIN DRIVE Report Date: 10/9/25, 9:23 AM 1 of 11 Envelope Assemblies Prop. Req. Assembly Gross Area or Cavity Cont. U- U- Prop. Req. Perimeter R Value R Value Factor/ Factor/ UA UA F-Factor F-Factor Ceiling: Cathedral Ceiling 2149 49.0 0.0 0.022 0.026 47 56 Floor: Slab -On -Grade 270 10.0 0.510 0.540 0 0 (Unheated) Insulation depth: 3.00' Insulation position: Vertical Insulation Wall: Wood Frame, 16" 876 20.0 6.0 0.042 0.060 34 48 O.C. Orientation: Left side Window: Vinyl Frame 75 0.260 0.300 20 23 Orientation: Left side Wall 3: Wood Frame, 16" 1502 20.0 6.0 0.042 0.060 52 75 O.C. Orientation: Front Window 3: Vinyl Frame 114 0.260 0.300 30 34 Orientation: Front Door 2: Glass Door (over 144 0.300 0.300 43 43 50% glazing) Orientation: Front Wall 2: Wood Frame, 16" 876 20.0 6.0 0.042 0.060 27 38 O.C. Orientation: Right side Window 2: Vinyl Frame 52 0.260 0.300 14 16 Orientation: Right side Door 1: Solid Door (under 192 0.166 0.300 32 58 50% glazing) Orientation: Right side Wall 1: Steel Frame, 16" 1364 20.0 6.0 0.066 0.060 77 70 O.C. Orientation: Back Window 1: Vinyl Frame 128 0.260 0.300 33 38 Orientation: Back Door: Glass Door (over 64 0.300 0.300 19 19 50% glazing) Orientation: Back The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Slab -on -grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab -on -grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Compliance Statement The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name - Title Signature Date 'i �/ j Inspection Checklist u Energy Code: 2018 IECC Requirements: 0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Pre-inspection/Plan Review Section Plans Field # Verified Verified & Req.ID Pre-Inspection/Plan Review Value Value Complies? 103.1, m Construction drawings and Complies 103.2 documentation demonstrate O Does Not [PR111 energy code compliance for the building envelope. Thermal Comply envelope represented on Not construction documents. O servable O Not Applicable 103.1, Construction drawings and Q Complies 103.2. documentation demonstrate Does Not 403.7 energy code compliance for Comply [PR311 lighting and mechanical systems. Systems serving Not multiple dwelling units must servable demonstrate compliance with Provisions. Ej Not the IECC Commercial Applicable 302.1, Heating and cooling equipment Heating: Heating: Btu/hr Q Complies 403.7 [PR2]2 is sized per ACCA Nlanuai S based on loads calculated per Btu/hr f '� Does Not Comply ACCA Manual J or other methods„I approved by the code ofFiciat. Cooling: Cooling: Btu hr [� Not Btu/hr O servable Not Applicable Additional Comments/Assumptions: Comments/Assumptions 1 1 High Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 1 3 Low Impact (Tier 3) ] Report Title: CUC - ODIN DRIVE Report Date: 10/9/25, 9:23 AM 3 of 11 Foundation Inspection Section # Plans Verified Field Verified & Req.l#? Foundation Inspection. Value Value Complies? 402.1 1 2 Slab edge insulation R-value. � ' - R�� O Complies Q Unheated ❑ Unheated � Does Not ` Imply 0 Heated 0 Heated O Not Observable PNot pplicable 303.2.1 [F011]2 A protective covering is installed to protect exposed exterior insulation and extends CD Complies Does Not a minimum of 6 in. below grade. omply Not servable PNot plicable 403.9 Snow- and ice -melting system [FO12]2 controls installed. 402.1.2 Slab edge insulation [FO3]1 depthliength. Additional Comments/Assumptions: Complies PoDoesNot omply Wot ervable Not plicable Commtints/Assiorp lions See the Envelope Assemblies table for values ft 1 ft Complies See the Envelope Does Not Assemblies table for values Umply Not servable PNot licable 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 I Low Impact (Tier 3) Framing / Rough -in Inspection s• Section Plans Field # Framing / ftaugh-In Verified Verified & Req.ID Inspect;.,, Value Value Compiles? 402.1.1, Door U-factor. U� �� ❑ Complies 402.3.4 ❑Does Not [FRl]1 Comply Not Ob servable ❑Not Applicable Comments/Assumptlons See the Envelope Assemblies table for values 402.1.1, Glazing U-factor (area -weighted U� U-= ❑ Complies See the Envelope Assemblies table for 402.3.1, average). Does Not values 402.3.3, 402.5 Imply [FR2]1 1-1 Not servable Not A pplicable l 402.4.1.1 Air barrier and thermal barrier Complies [FR23]1 installed per manufacturer's instructions.Does Not 402.4.3 [FR20]1 402.4.5 [FR16]z Imply Not servable QNot pplicable Fenestration that is not site built ❑ Complies is listed and labeled as meeting ❑ Does Not AAMA /WDMA/CSA 101/I.S.2/A440 or has infiltration Comply rates per NFRC 400 that do not Not exceed code limits. servable ❑ Not Applicable IC -rated recessed lighting ❑ Complies fixtures sealed at housing/interior finish and ❑ Does Not labeled to indicate :52.0 cfm Comply leakage at 75 Pa. ❑ Not Observable ❑ Not Applicable 403.3.1 su pIy and return ducts in attics ❑ Complies [FR12]1 insulated >= R-8 where duct is >= 3 inches in diameter and ❑ Does Not >= R-6 where < 3 inches. Comply Supply and return ducts in other [� Not portions of the building O servable insulated >= R 6 for diameter >= 3 inches and R-4.2 for < 3 ❑ Not inches in diameter. Applicable 403.3.2 Ducts, air handlers and filter ❑ Complies [FR13]1 boxes are sealed with joints/seams compliant with Does Not International Mechanical Code Imply or International Residential Not Code, as applicable. servable ❑ Not Applicable 403.3.5 Building cavities are not used as ❑ Complies [FR15]3 ducts or plenums. ❑ Does Not Comply Not O servable ❑ Not J Applicable Report Title: CUC - ODIN DRIVE Report Date: 10/9/25, 9:23 AM 5 of 11 Section # & Req.ID Framing I Rough -In Inspection 403.3.7 Ducts declared to be within the [FR28]3 conditioned space are either 1) completely within the continuous air barrier and within the building thermal envelope, 2) buried within ceiling insulation in accordance with Section R403.3.6 and the air handler Is located completely within the continuous air barrier and within the building thermal envelope and the duct leakage is — 1.5 cfm 1 100 square feet of conditioned floor area served by the duct system, or 3) the ceiling insulation R-value installed against and above the insulated duct >= to the proposed ceiling insulation R- vaiue, less the R-value of the insulation on the duct. 403.4 HVAC pipin? conveying fluids above 105 fluids [FR17]� -For chilled below 55 4F are insulated to >R- 3. 403.4.1 Protection of insulation on HVAC [FR24]1 piping. Plans Field Verified Vertfiied Value Value 403.5.? aR 3 water pipes are insulated to I � R [FRIB] 403.6 Automatic or gravity dampers [FR191' are installed on all outdoor air intakes and exhausts. 303.1.3 U-factors of fenestration [FR4]1 products are determined in accordance with the NFRC test procedure or taken from the default table. Additional Comments/Assumptions: Complies? Complies PoDoesNot omply RNot servable Not pplicable Cj Complies PoDoesNot omply Not servable Not pplicable E) Complies omDoes Not ply 9 Not servable PNot plicable O Complies Does Not omply PNot servable PpNot pplicable Complies Does Not omply Wot N servable Not pplicable ❑ Complies PoDoesNot omply Not servable Not pplicable Comments/Assumptions 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Insulation Inspection Section Plans # Verified & Req.111) Insulation Inspection Value 303.1 All installed insulation is labeled EIN1317 orthe installed Rvalues provided. Field � f Verified Value Compiles? Comments/Assunlptlons O Complies Does Not Comply Not servable Not pplicable I Wall insulation R-value. Ifthis is 1h R� R� Complies 402.1.1, 402.2.5, a mass wall with at least of Does Not 402.2.6 the wall insulation on the wall 0Wood 0Wood [IN3]1 rrequi�ement applies the r(FRIO.ion � Mass � Mass oo Not Steel Steel observable Fj Not pplicable 1303.2 Wall insulation is installed per Complies [IN4]1 manufacturer's instructions. Does Not mply Not servable i� Not pplicable Additional Comments/Assumptions: See the Envelope Assemblies table for values 1 1 High Impact (Tier 1) 1 2 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3) Report Title: CUC - ODIN DRIVE Report Date: 10/9/25, 9:23 AM 7 of 11 Final Inspection Provisions Section Plans Field # Verified Verified & Req.ID Final Inspection Provisions Value Value Complies? Comments/Assumptions 402.1.1, Ceiling insulation R-value. R� I � I O Complies See the Envelope 402.2.2, 402.2.E Wood Assemblies table for Wood Does Not values [FI1]ervable Steel O Steel o Not Wy Not pplicable 303.1.1.1, 303.2 'Ceiling insulation installed per manufacturer's instructions. O Complies [F1211 Blown insulation marked every Q Does Not 300 ft-1. Comply [� Not Observable 0 Not pplicable i 403.1.2 [F[10]2 Heat pump thermostat installed on heat pumps. Complies Does Not Comply Not servable Not pplicable 403.5.1 i Circulating service hot water Complies [FI11]2 systems have automatic or accessible manual controls. Does Not Comply Not servable (� Not pplicable 403.6.1 [FI25]2 All mechanical ventilation system Fans not part of tested Complies and listed HVAC equipment n Does Not meet efficacy and air flow limits omply per Table R403.5.1. Not servable Not pplicable 403.2 [FI26]2 Hot water boilers supplying heat through one- or two -pipe Complies heating systems have outdoor Does Not setback control to lower boiler omply water temperature based on outdoor temperature. [ � Not Observable Not pplicable 403.5.1.1 [FI2812 Heated water circulation systems have a circulation Q Complies pump. The system return pipe is Does Not a dedicated return pipe or a C omply cold water supply pipe. Gravity and thermos -syphon circulation j(��] Not Observable systems are not present. Controls for circulating hot Not water system pumps start the pplicable pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set -point temperature and no demand for hot water exists. 403.5.1.2 [FI2912 Electric heat trace systems comply with IEEE 515.1 or UL Complies 515, Controls automatically Does Not adjust the energy input to the omply heat tracing to maintain the desired water temperature in Not the piping, servable ONot plicable # Verified Verified _ _ __ �. _ - _••___ '�__-- _____ _ ___ _ .._ t`..�..1:..�•f P...w.Mewh�/Acc��rn n*innc 403.5.2 Demand recirculation water [F130]2 systems have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to <= 104°F. 403.5.4 Drain water heat recovery units [F[31]2 tested in accordance with CSA B55.1. Potable water -side pressure loss of drain water heat recovery units < 3 psi for individual units connected to one or two showers. Potable water -side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. O Complies Does Not omply RNot Observable Not pplicable Complies Does Not Comply Not O servable Not Applicable 404.1 90% or more of permanent O Complies [FI6]1 fixtures have high efficacy � Does Not lamps. Comply Not Observable Not Applicable i 404.1.1 Fuel gas lighting systems have O Complies [F123]3 no continuous pilot light. Does Not Comply WNot ervable Not Applicable 401.3 Compliance certificate posted. Complies [F17]2 Does Not omply RNot O servable Not Applicable 303.3 Manufacturer manuals for Complies [FI18]3 mechanical and water heating Does Not systems have been provided. omply Not ` servable R 0 Not Applicable 402.2.3 Vented attics with air permeable 0 Complies [FI22]2 insulation include baffle adjacent to soffit and eave 0 Does Not vents that extends over Comply insulation. Not RO servable Not Applicable i 402.2.4 Attic access hatch and door R� R= O Complies [FI3]1 insulation >_R-value of the Does Not adjacent assembly. Comply Not O servable Not i Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = Complies [FI17]1 ach in Climate Zones 1-2, and j-� O Does Not <=3 ach in Climate Zones 3-8. V�JJ Comply i W[]Not servable Not Applicable Report Title: CUC - ODIN DRIVE Report Date: 10/9/25, 9:23 AM 9 of 11 Section Plans Field # & Req.iD Final Inspection provisldhs, Verified Verified Value Value Complies? 403.3.3 Ducts are pressure tested to determine air leakage Complies p [FI2711 with either: Rough -In test: Total cfm/100 ft2 cfm�/100 ft2 ( J Does Not leakage measured with a Comply pressure differential of 0.1 inch jQ� Not w.g. across the system including Observable the manufacturer's air handler enclosure if installed at time of Not test. Postconstruction test: Total � A pplicable leakage measured with a pressure differential of 0.1 inch w.g, across the entire system including the manufacturer's air handier enclosure. 403.3.4 Duct tightness test result of ¢=4 cfm/100 ft2 across the 0 Complies [FI411 system or < = 3 cfrn/100 ft2 Ifni/100 ft2 cfrri/100 ft2 Does Not without air handler IP 25 Pa, for Imply rough -in tests, verification may Not need to occur during Framing Inspection, Observable PNot pplicable 403.3.2.1 Air handler leakage designated by manufacturer Complies p [FI2411 at =2% of design airflow. Does Not omply Not servable PNot plicable 403.1.1 Programmable thermostats 0 Complies [FIgF installed for control of primary heating and cooling systems Does Not and Initially set by manufacturer Imply to code specifications. [� Not Wervable PNot plicable Additional Comments/Assumptions: Comments/Assumptions 1 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 j Low Impact (Tier 3) 2018 iECC Energy Efficiency Certificate Insulation Rating R-Va'iu6 Above -Grade Wall 26.00 Below -Grade Wall 0.00 Floor 10.00 Ceiling / Roof 49.00 Ductwork (unconditioned spaces): .. I _ Window Door Skylight I Heating System: Cooling System: Water Heater: 0.26 0.17 0.00 Signature Name: Date: Comments: Report Title: CUC - ODIN DRIVE Report Date: 10/9/25, 9:23 AM 11 of 11 1 � - � K 1 � ' ti z` 4PLVM` MPmY -P�