REScheck*Web TM
Compliance Certificate
Project Information
Project Title:
Energy Code:
Location:
Construction Type:
Project Type:
Project Sub Type:
Orientation:
Conditioned Floor Area:
Glazing Area:
Climate Zone:
Project No:
All Electric:
Is Renewable:
Has Battery:
Has Charger:
Has Heat Pump
Construction Site:
672 ODIN DRIVE
SILT, CO 81651
Project Notes:
CUC - ODIN DRIVE
2018 IECC
Garfield, Colorado
Single Family
New Construction
None
Bldg. faces 270 deg. from North
4399 ft2
12%
5b (8499 HDD)
1769002
true
false
false
true
false
Owner/Agent:
ERNESTO CUC
625 AIRPORT ROAD
COKE OVENS 2 LLC
GLENWOOD SPRINGS, CO 81601
9704042224
ER N E STO @CU CCO N STRU CTI O N. CO M
Designer/Contractor:
BRADJORDAN
PO BOX 1031
JORDAN ARCHITECTURE
GLENWOOD SPRINGS, CO 81602
9706186690
BRADJORDANARCHITECT@GMAIL.COM
Report Title: CUC - ODIN DRIVE Report Date: 10/9/25, 9:23 AM 1 of 11
Envelope Assemblies
Prop.
Req.
Assembly
Gross Area or
Cavity
Cont.
U-
U-
Prop.
Req.
Perimeter
R Value
R Value
Factor/
Factor/
UA
UA
F-Factor
F-Factor
Ceiling: Cathedral Ceiling
2149
49.0
0.0
0.022
0.026
47
56
Floor: Slab -On -Grade
270
10.0
0.510
0.540
0
0
(Unheated)
Insulation depth: 3.00'
Insulation position:
Vertical Insulation
Wall: Wood Frame, 16"
876
20.0
6.0
0.042
0.060
34
48
O.C.
Orientation: Left side
Window: Vinyl Frame
75
0.260
0.300
20
23
Orientation: Left side
Wall 3: Wood Frame, 16"
1502
20.0
6.0
0.042
0.060
52
75
O.C.
Orientation: Front
Window 3: Vinyl Frame
114
0.260
0.300
30
34
Orientation: Front
Door 2: Glass Door (over
144
0.300
0.300
43
43
50% glazing)
Orientation: Front
Wall 2: Wood Frame, 16"
876
20.0
6.0
0.042
0.060
27
38
O.C.
Orientation: Right side
Window 2: Vinyl Frame
52
0.260
0.300
14
16
Orientation: Right side
Door 1: Solid Door (under
192
0.166
0.300
32
58
50% glazing)
Orientation: Right side
Wall 1: Steel Frame, 16"
1364
20.0
6.0
0.066
0.060
77
70
O.C.
Orientation: Back
Window 1: Vinyl Frame
128
0.260
0.300
33
38
Orientation: Back
Door: Glass Door (over
64
0.300
0.300
19
19
50% glazing)
Orientation: Back
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES
NOT provide an estimate of energy use or cost relative to a minimum -code home.
Slab -on -grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab -on -grade
assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements.
Compliance Statement
The proposed building design described here is consistent with the building plans, specifications, and other calculations
submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in
REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Name - Title Signature Date
'i �/ j Inspection Checklist
u
Energy Code: 2018 IECC
Requirements: 0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being
claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Pre-inspection/Plan Review
Section
Plans
Field
#
Verified
Verified
& Req.ID
Pre-Inspection/Plan Review
Value
Value
Complies?
103.1,
m Construction drawings and
Complies
103.2
documentation demonstrate
O Does Not
[PR111
energy code compliance for the
building envelope. Thermal
Comply
envelope represented on
Not
construction documents.
O servable
O Not
Applicable
103.1,
Construction drawings and
Q Complies
103.2.
documentation demonstrate
Does Not
403.7
energy code compliance for
Comply
[PR311
lighting and mechanical
systems. Systems serving
Not
multiple dwelling units must
servable
demonstrate compliance with
Provisions.
Ej Not
the IECC Commercial
Applicable
302.1,
Heating and cooling equipment
Heating:
Heating:
Btu/hr
Q Complies
403.7
[PR2]2
is sized per ACCA Nlanuai S
based on loads calculated per
Btu/hr
f '�
Does Not
Comply
ACCA Manual J or other methods„I
approved by the code ofFiciat.
Cooling:
Cooling:
Btu hr
[� Not
Btu/hr
O servable
Not
Applicable
Additional Comments/Assumptions:
Comments/Assumptions
1 1 High Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 1 3 Low Impact (Tier 3) ]
Report Title: CUC - ODIN DRIVE Report Date: 10/9/25, 9:23 AM 3 of 11
Foundation Inspection
Section
#
Plans
Verified
Field
Verified
& Req.l#?
Foundation Inspection.
Value
Value
Complies?
402.1 1 2
Slab edge insulation R-value.
� ' -
R��
O Complies
Q
Unheated
❑
Unheated
� Does Not
` Imply
0 Heated
0 Heated
O Not
Observable
PNot
pplicable
303.2.1
[F011]2
A protective covering is
installed to protect exposed
exterior insulation and extends
CD Complies
Does Not
a minimum of 6 in. below grade.
omply
Not
servable
PNot
plicable
403.9 Snow- and ice -melting system
[FO12]2 controls installed.
402.1.2 Slab edge insulation
[FO3]1 depthliength.
Additional Comments/Assumptions:
Complies
PoDoesNot
omply
Wot
ervable
Not
plicable
Commtints/Assiorp lions
See the Envelope
Assemblies table for
values
ft 1 ft Complies See the Envelope
Does Not Assemblies table for
values
Umply
Not
servable
PNot
licable
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 I Low Impact (Tier 3)
Framing / Rough -in Inspection
s•
Section
Plans
Field
# Framing / ftaugh-In
Verified
Verified
& Req.ID Inspect;.,,
Value
Value
Compiles?
402.1.1,
Door U-factor.
U�
��
❑ Complies
402.3.4
❑Does Not
[FRl]1
Comply
Not
Ob servable
❑Not
Applicable
Comments/Assumptlons
See the Envelope
Assemblies table for
values
402.1.1,
Glazing U-factor (area -weighted
U�
U-=
❑ Complies See the Envelope
Assemblies table for
402.3.1,
average).
Does Not values
402.3.3,
402.5
Imply
[FR2]1
1-1 Not
servable
Not
A pplicable
l 402.4.1.1
Air barrier and thermal barrier
Complies
[FR23]1
installed per manufacturer's
instructions.Does
Not
402.4.3
[FR20]1
402.4.5
[FR16]z
Imply
Not
servable
QNot
pplicable
Fenestration that is not site built
❑ Complies
is listed and labeled as meeting
❑ Does Not
AAMA /WDMA/CSA
101/I.S.2/A440 or has infiltration
Comply
rates per NFRC 400 that do not
Not
exceed code limits.
servable
❑ Not
Applicable
IC -rated recessed lighting
❑ Complies
fixtures sealed at
housing/interior finish and
❑ Does Not
labeled to indicate :52.0 cfm
Comply
leakage at 75 Pa.
❑ Not
Observable
❑ Not
Applicable
403.3.1
su pIy and return ducts in attics
❑ Complies
[FR12]1
insulated >= R-8 where duct is
>= 3 inches in diameter and
❑ Does Not
>= R-6 where < 3 inches.
Comply
Supply and return ducts in other
[� Not
portions of the building
O servable
insulated >= R 6 for diameter
>= 3 inches and R-4.2 for < 3
❑ Not
inches in diameter.
Applicable
403.3.2
Ducts, air handlers and filter
❑ Complies
[FR13]1
boxes are sealed with
joints/seams compliant with
Does Not
International Mechanical Code
Imply
or International Residential
Not
Code, as applicable.
servable
❑ Not
Applicable
403.3.5
Building cavities are not used as
❑ Complies
[FR15]3
ducts or plenums.
❑ Does Not
Comply
Not
O servable
❑ Not
J Applicable
Report Title: CUC - ODIN DRIVE
Report Date: 10/9/25, 9:23 AM 5 of 11
Section
#
& Req.ID
Framing I Rough -In
Inspection
403.3.7
Ducts declared to be within the
[FR28]3
conditioned space are either 1)
completely within the
continuous air barrier and within
the building thermal envelope,
2) buried within ceiling
insulation in accordance with
Section R403.3.6 and the air
handler Is located completely
within the continuous air barrier
and within the building thermal
envelope and the duct leakage
is — 1.5 cfm 1 100 square feet
of conditioned floor area served
by the duct system, or 3) the
ceiling insulation R-value
installed against and above the
insulated duct >= to the
proposed ceiling insulation R-
vaiue, less the R-value of the
insulation on the duct.
403.4
HVAC pipin? conveying fluids
above 105 fluids
[FR17]�
-For chilled
below 55 4F are insulated to >R-
3.
403.4.1 Protection of insulation on HVAC
[FR24]1 piping.
Plans Field
Verified Vertfiied
Value Value
403.5.? aR 3 water pipes are insulated to I � R
[FRIB]
403.6 Automatic or gravity dampers
[FR191' are installed on all outdoor air
intakes and exhausts.
303.1.3 U-factors of fenestration
[FR4]1 products are determined in
accordance with the NFRC test
procedure or taken from the
default table.
Additional Comments/Assumptions:
Complies?
Complies
PoDoesNot
omply
RNot
servable
Not
pplicable
Cj Complies
PoDoesNot
omply
Not
servable
Not
pplicable
E) Complies
omDoes Not
ply
9 Not
servable
PNot
plicable
O Complies
Does Not
omply
PNot
servable
PpNot
pplicable
Complies
Does Not
omply
Wot
N
servable
Not
pplicable
❑ Complies
PoDoesNot
omply
Not
servable
Not
pplicable
Comments/Assumptions
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Insulation Inspection
Section
Plans
#
Verified
& Req.111)
Insulation Inspection Value
303.1
All installed insulation is labeled
EIN1317
orthe installed Rvalues
provided.
Field � f
Verified
Value Compiles? Comments/Assunlptlons
O Complies
Does Not
Comply
Not
servable
Not
pplicable
I
Wall insulation R-value. Ifthis is
1h
R�
R�
Complies
402.1.1,
402.2.5,
a mass wall with at least of
Does Not
402.2.6
the wall insulation on the wall
0Wood
0Wood
[IN3]1
rrequi�ement applies the r(FRIO.ion
� Mass
� Mass
oo Not
Steel
Steel
observable
Fj Not
pplicable
1303.2
Wall insulation is installed per
Complies
[IN4]1
manufacturer's instructions.
Does Not
mply
Not
servable
i� Not
pplicable
Additional Comments/Assumptions:
See the Envelope
Assemblies table for
values
1 1 High Impact (Tier 1) 1 2 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3)
Report Title: CUC - ODIN DRIVE Report Date: 10/9/25, 9:23 AM 7 of 11
Final Inspection Provisions
Section Plans Field
# Verified Verified
& Req.ID Final Inspection Provisions Value Value Complies? Comments/Assumptions
402.1.1,
Ceiling insulation R-value. R�
I � I O Complies See the Envelope
402.2.2,
402.2.E
Wood
Assemblies table for
Wood Does Not values
[FI1]ervable
Steel
O Steel o Not
Wy
Not
pplicable
303.1.1.1,
303.2
'Ceiling insulation installed per
manufacturer's instructions.
O Complies
[F1211
Blown insulation marked every
Q Does Not
300 ft-1.
Comply
[� Not
Observable
0 Not
pplicable
i 403.1.2
[F[10]2
Heat pump thermostat installed
on heat pumps.
Complies
Does Not
Comply
Not
servable
Not
pplicable
403.5.1
i Circulating service hot water
Complies
[FI11]2
systems have automatic or
accessible manual controls.
Does Not
Comply
Not
servable
(� Not
pplicable
403.6.1
[FI25]2
All mechanical ventilation
system Fans not part of tested
Complies
and listed HVAC equipment
n Does Not
meet efficacy and air flow limits
omply
per Table R403.5.1.
Not
servable
Not
pplicable
403.2
[FI26]2
Hot water boilers supplying heat
through one- or two -pipe
Complies
heating systems have outdoor
Does Not
setback control to lower boiler
omply
water temperature based on
outdoor temperature.
[ � Not
Observable
Not
pplicable
403.5.1.1
[FI2812
Heated water circulation
systems have a circulation
Q Complies
pump. The system return pipe is
Does Not
a dedicated return pipe or a
C omply
cold water supply pipe. Gravity
and thermos -syphon circulation
j(��] Not
Observable
systems are not present.
Controls for circulating hot
Not
water system pumps start the
pplicable
pump with signal for hot water
demand within the occupancy.
Controls automatically turn off
the pump when water is in
circulation loop is at set -point
temperature and no demand for
hot water exists.
403.5.1.2
[FI2912
Electric heat trace systems
comply with IEEE 515.1 or UL
Complies
515, Controls automatically
Does Not
adjust the energy input to the
omply
heat tracing to maintain the
desired water temperature in
Not
the piping,
servable
ONot
plicable
# Verified Verified
_ _ __ �. _ - _••___ '�__-- _____ _ ___ _ .._ t`..�..1:..�•f P...w.Mewh�/Acc��rn n*innc
403.5.2 Demand recirculation water
[F130]2 systems have controls that
manage operation of the pump
and limit the temperature of the
water entering the cold water
piping to <= 104°F.
403.5.4 Drain water heat recovery units
[F[31]2 tested in accordance with CSA
B55.1. Potable water -side
pressure loss of drain water
heat recovery units < 3 psi for
individual units connected to
one or two showers. Potable
water -side pressure loss of drain
water heat recovery units < 2
psi for individual units
connected to three or more
showers.
O Complies
Does Not
omply
RNot
Observable
Not
pplicable
Complies
Does Not
Comply
Not
O servable
Not
Applicable
404.1
90% or more of permanent
O Complies
[FI6]1
fixtures have high efficacy
� Does Not
lamps.
Comply
Not
Observable
Not
Applicable
i
404.1.1
Fuel gas lighting systems have
O Complies
[F123]3
no continuous pilot light.
Does Not
Comply
WNot
ervable
Not
Applicable
401.3
Compliance certificate posted.
Complies
[F17]2
Does Not
omply
RNot
O servable
Not
Applicable
303.3
Manufacturer manuals for
Complies
[FI18]3
mechanical and water heating
Does Not
systems have been provided.
omply
Not
` servable
R
0 Not
Applicable
402.2.3
Vented attics with air permeable
0 Complies
[FI22]2
insulation include baffle
adjacent to soffit and eave
0 Does Not
vents that extends over
Comply
insulation.
Not
RO
servable
Not
Applicable
i
402.2.4
Attic access hatch and door
R� R=
O Complies
[FI3]1
insulation >_R-value of the
Does Not
adjacent assembly.
Comply
Not
O servable
Not
i
Applicable
402.4.1.2
Blower door test @ 50 Pa. <=5
ACH 50 = ACH 50 =
Complies
[FI17]1
ach in Climate Zones 1-2, and
j-�
O Does Not
<=3 ach in Climate Zones 3-8.
V�JJ
Comply
i
W[]Not
servable
Not
Applicable
Report Title: CUC - ODIN DRIVE Report Date: 10/9/25, 9:23 AM 9 of 11
Section
Plans Field
#
& Req.iD
Final Inspection provisldhs,
Verified Verified
Value Value
Complies?
403.3.3
Ducts are pressure tested to
determine air leakage
Complies
p
[FI2711
with
either: Rough -In test: Total
cfm/100 ft2
cfm�/100 ft2
( J Does Not
leakage measured with a
Comply
pressure differential of 0.1 inch
jQ� Not
w.g. across the system including
Observable
the manufacturer's air handler
enclosure if installed at time of
Not
test. Postconstruction test: Total
�
A pplicable
leakage measured with a
pressure differential of 0.1 inch
w.g, across the entire system
including the manufacturer's air
handier enclosure.
403.3.4
Duct tightness test result of
¢=4 cfm/100 ft2 across the
0 Complies
[FI411
system or < = 3 cfrn/100 ft2
Ifni/100 ft2
cfrri/100 ft2
Does Not
without air handler IP 25 Pa, for
Imply
rough -in tests, verification may
Not
need to occur during Framing
Inspection,
Observable
PNot
pplicable
403.3.2.1
Air handler leakage designated
by manufacturer
Complies
p
[FI2411
at =2% of
design airflow.
Does Not
omply
Not
servable
PNot
plicable
403.1.1
Programmable thermostats
0 Complies
[FIgF
installed for control of primary
heating and cooling systems
Does Not
and Initially set by manufacturer
Imply
to code specifications.
[� Not
Wervable
PNot
plicable
Additional
Comments/Assumptions:
Comments/Assumptions
1 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 j Low Impact (Tier 3)
2018 iECC Energy
Efficiency
Certificate
Insulation Rating
R-Va'iu6
Above -Grade Wall
26.00
Below -Grade Wall
0.00
Floor
10.00
Ceiling / Roof
49.00
Ductwork (unconditioned spaces):
.. I _
Window
Door
Skylight
I
Heating System:
Cooling System:
Water Heater:
0.26
0.17
0.00
Signature
Name: Date:
Comments:
Report Title: CUC - ODIN DRIVE Report Date: 10/9/25, 9:23 AM 11 of 11