HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLRE-10-25-9568
FI N N BAR FLATS LLC
ADDING A DECK AND STAIRS TO THE EXISTING BARN
33 ST. FI N N BAR FARM ROAD
CARBONDALE, CO 81623
1) THE APPROVED PLANS ARE TO BE ON -SITE FOR INSPECTIONS.
2) SANITARY FACILITIES ARE REQUIRED TO BE PROVIDED FOR WORKERS.
3) A LIST OF REQUIRED INSPECTIONS WILL BE ATTACHED TO THE PLANS. THE STATE
IS TO PERMIT AND APPROVE THE ELECTRICAL WORK.
HTTPS://WWW.COLORADO.GOV/PA IFIC/DORA/DPO ELECTRICAL PL MBING PE
RMITS
4) UNDERGROUND UTILITY LOCATES IS THE RESPONSIBILITY OF THE OWNER OR
CONTRACTOR. 811 IS THE COLORADO UTILITY LOCATE HOT LINE.
5) SEPARATE SIGN PERMITS ARE REQUIRED FOR ANY EXTERNAL SIGNS. PLEASE
CONTACT THE COUNTY PLANNER FOR THE APPLICATION.
6) ELECTRICAL CODE COMPLIANCE WILL BE DETERMINED BASED ON FIELD
INSPECTIONS PERFORMED BY THE STATE ELECTRICAL INSPECTOR, (303) 869-3458.
PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN
DOCUMENTATION OF THE INSPECTIONS. THE EXTERIOR DOOR AND STAIRS WILL
REQUIRE A LIGHT.
7) SAFETY GLAZING IS NOT DESIGNATED ON THE PLANS. SAFETY GLAZING WILL BE
CHECKED DURING THE FRAMING AND FINAL INSPECTION. (IBC 2406.4)
8) ANY EXPOSED FOAM IS TO BE COVERED WITH AN IGNITION BARRIER OR A
THERMAL BARRIER BASED ON LOCATION. (IRC R316)
9) GEOTECHNICAL ENGINEER'S REPRESENTATIVE TO OBSERVE THE EXCAVATION
AND PROVIDE A REPORT VERIFYING THE ASSUMED 3000PSF IS BEING MET PRIOR
TO A FOOTING INSPECTION TO BE PERFORMED.
10)ALL EXTERIOR LIGHTING IS TO BE DOWNCAST AND SHIELDED.
1 1)WOOD COLUMNS ARE TO BE 6" ABOVE FINISHED GRADE OR BE PRESSURE
TREATED.
12)THE NEW STAIRS ARE TO HAVE A GRIPPALBE HANDRAIL WITH RETURNS ON ONE
SIDE OF THE STAIRS.
13) CALL FOR INSPECTION OF THE NEW HEADERS PRIOR TO COVERING.