Compliance Certificate
Project Information
Project Title:
Energy Code:
Location:
Construction Type:
Project Type:
Project Sub Type:
Orientation:
Conditioned Floor Area:
Glazing Area:
Climate Zone:
Project No:
All Electric:
Is Renewable:
Has Battery:
Has Charger:
Has Heat Pump
Construction Site:
200 SADDLEBACK ROAD
GARFIELD COUNTY, CO 81623
Project Notes:
DOCKERS CONSTRUCTION
2018 IECC
Garfield, Colorado
Single Family
New Construction
None
Bldg. faces 225 deg. from North
5251 ft2
16%
5b (8499 HDD)
1774048
false
false
false
true
true
Owner/Agent:
DAVID OCKERS
DOCKERS CONSTRUCTION
GLENWOOD SPRINGS, CO 81601
9709873527
DAV I D@ DOCKERSCONSTRUCTIO N.COM
Designer/Contractor:
BRADJORDAN
PO BOX 1031
JORDAN ARCHITECTURE
GLENWOOD SPRINGS, CO 81602
9706186690
BRADJORDANARCHITECT@GMAIL.COM
,Z
Report Title: DOCKERS CONSTRUCTION Report Date: 10/13/25, 8:15 AM 1 of 12
Envelope Assemblies
Assembly
Gross Area or
Perimeter
Cavity
R Value
Cont.
R Value
Prop.
U-
Factor/
F-Factor
Req.
U-
Factor/
F-Factor
Prop.
UA
Req.
UA
Ceiling: Flat Ceiling or
3494
49.0
0.0
0.026
0.026
91
91
Scissor Truss
Wall: Wood Frame, 16" o.c.
1464
20.0
6.0
0.042
0.060
54
78
Orientation: Front
Window: Metal Frame w/
145
0.260
0.300
38
44
Thermal Break
Orientation: Front
Door: Solid Door (under
24
0.166
0.300
4
7
50% glazing)
Orientation: Front
Wall 1: Wood Frame, 16"
1265
20.0
6.0
0.042
0.060
44
63
O.C.
Orientation: Left side
Window 1: Metal Frame w/
188
0.260
0.300
49
56
Thermal Break
Orientation: Left side
Door 1: Solid Door (under
24
0.166
0.300
4
7
50% glazing)
Orientation: Left side
Wall 2: Wood Frame, 16"
1326
20.0
10.0
0.036
0.060
37
61
O.C.
Orientation: Back
Window 2: Metal Frame w/
285
0.260
0.300
74
86
Thermal Break
Orientation: Back
Door 2: Glass Door (over
24
0.300
0.300
7
7
50% glazing)
Orientation: Back
Wall 3: Wood Frame, 16"
934
20.0
6.0
0.042
0.060
28
39
O.C.
Orientation: Right side
Window 3: Metal Frame w/
125
0.260
0.300
33
38
Thermal Break
Orientation: Right side
Door 3: Solid Door (under
152
0.166
0.300
25
46
50% glazing)
Orientation: Right side
Basement Wall: Solid
594
19.0
10.0
0.030
0.050
17
28
Concrete or Masonry
Orientation: Right side
Wall height: 9.00
Insulation depth: 9.00'
Insulation position:
Integral Insulation
Window: Metal Frame w/
25
0.260
0.300
7
8
Thermal Break
Orientation: Right side
Basement Wall: Solid
472
19.0
10.0
0.030
0.050
13
22
Concrete or Masonry
Orientation: Back
Wall height: 9.00
Insulation depth: 9.00'
Insulation position:
Integral Insulation
Window 1: Metal Frame w/
25
0.260
0.300
7
8
Thermal Break
Orientation: Back
Prop. Keq.
Assembly Gross Area or Cavity Cont. U- U- Prop. Req.
Perimeter R Value R Value Factor/ Factor/ ILIA UA
F-Factor F-Factor
Basement Wall: Solid 594
Concrete or Masonry
Orientation: Left side
Wall height: 9.00
Insulation depth: 8.00'
Insulation position:
Integral Insulation
Basement Wall: Solid 472
Concrete or Masonry
Orientation: Front
Wall height: 9.00
Insulation depth: 8.00'
Insulation position:
Integral Insulation
19.0 10.0 0.034 0.050 20 30
19.0 10.0 0.034 0.050 16 24
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES
NOT provide an estimate of energy use or cost relative to a minimum -code home.
Slab -on -grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab -on -grade
assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements.
Compliance Statement
The proposed building design described here is consistent with the building plans, specifications, and other calculations
submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in
REScheck Web and to comply with the mand re in the REScheck Inspection Checklist.
Name - Title ure Date
Report Title: DOCKERS CONSTRUCTION Report Date: 10113/25, 8:15 AM 3 of 12
r�(11 Inspection Checklist
Energy Code: 2018 IECC
Requirements: 0% were addressed directly in the RESCheCk software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being
claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Pre-Inspection/Plan Review
Section
Y Plans
#
Verified
& Req.ID
Pre-Inspection/Plan Review Value
103.1,
Construction drawings and
103.2
documentation demonstrate
[PR1]1
energy code compliance for the
building envelope. Thermal
envelope represented on
construction documents.
Field
Verified
Value Complies?
0 Complies
omDoes Not
ply
PNot
servable
Not
pplicable
103.11
103.2,
Construction drawings and
documentation demonstrate
0 Complies
403.7
energy code compliance For
Does Not
[PR3]1
lighting and mechanical
Pmply
systems. Systems serving
multiple dwelling units must
(� Not
demonstrate compliance with
i56servable
the IECC Commercial Provisions.
Not
pplicable
302.1.
403.7
Heating and cooling equl ment
is sized ACCA Manual S
Heating:
Btulhr
Heating-
0 Complies
[PR2]2
per
based on loads calculated per
ACCA Manual 1
Stulhr
Does Not
or other methods
L�
U
Comply
approved by the code official.
Cooling:
Stulhr
Cooling:
Btu/�hr
� Not
servable
0Not
plicable
Additional Comments/Assumptions:
Comments/Assumptions
1 I High Impact (Tier 1} 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Foundation Inspection
Section
& Req.ID
Foundation Inspection
303.2.1
A protective covering is
[F01111'
installed to protect exposed
exterior insulation and extends
a minimum of 6 in. below grade.
403.9 Snow- and ice -melting system
(F01217 controls installed.
Plans Field
Verified Verified
Value value
complies? Comments/Assumptions
O Complies
Does Not
amply
Not
servable
Not
pplicable
D Complies
Does Not
omply
Not
servable
O Not
Applicable
402.1.1
Conditioned basement wall R��-
R�
Complies See the Envelope
Assemblies table for
[F04]1
insulation R-value. Where
interior insulation is used,
R=
R
Does Not i values
amply
verification may need to occur
during Insulation Inspection. Not
Not
required in warm -humid
servable
locations in Climate Zone 3.
Not
1pplicable
303.2 Conditioned basement wall
[F0511 insulation installed per
manufacturer's instructions.
E) Complies
Q Does Not
amply
Not
servable
Not
pplicable
402.2.9 Conditloned basement wall ft ft 0 Complies See the Envelope
[F06I1 insulation depth of burial or l� Does Not Assemblies table fior
distance from top of wall.
omply
Ob Not
servable
0 Not
Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Report Title: DOCKERS CONSTRUCTION Report Date: 10/13/25, 8:15 AM 5 of 12
Framing / Rough -in inspection
Section Plans
# Framing / Rough -In Verified
& Req.ID Inspection Value
Field
Verified
Value Complies?
Comments/Assumptions
402.3.4
Door U-factor.
U
v Complies
See the Envelope
[FR1]1
Does Not
Comply
Assemblies table for
values
Ob Not
servable
[ Not
pplicable
402.1.1,
402.3.1,
Glazing U-factor (area -weighted
average).
U=
� Complies
See the Envelope
402.3.3.
Does Not
Assemblies table for
values
402.5
Comply
[FR2]1
Not
6bservable
Not
pplicable
402.4.1.1
1 Air barrier and thermal barrier
O Complies
[FR23]1
installed per manufacturer's
instructions.
Does Not
omply
Not
servable
Not
pplicable
402.4.3
[FR20]1
Fenestration that is not site built
is listed and labeled as meeting
Complies
AAMA IWDMA/CSA
Does Not
101/I.S.2/A440 or has infiltration
omply
rates per NFRC 400 that do not
exceed code limits.
[� Not
6bservable
Not
pplicable
402.4.5
[FR16]2
IC -rated recessed lighting
'fixtures sealed at
Q Complies
housing/interior finish and
labeled
Does Not
to indicate s2.0 cfm
omply
leakage at 75 Pa.
Not
Qservable
Not
pplicable
403.3.1
Suppl and return ducts in attics
Complies
[FR12]1
insula ed >= R-8 witiEfe duct is
>= 3 inches in diameter and
Does Not
>= R-6 where < 3 inches.
omply
Supply and return ducts in other
portions of the building
insulated
Not
Observable
>= R-6 for diameter
>= 3 inches and R-4.2 for < 3
[� Not
inches in diameter.
pplicable
403.3.2
[FR13]1
Ducts, air handlers and filter
boxes are seated with
� Complies
I
fointslseams compliant with
International
[—] Does Not
Mechanical Code
omply
or International Residential
Code, as applicable.
[] Not
Observable
Not
pplicable
403.3.5
Building cavities are not used as
Complies
[FR15]3
ducts or plenums.
Does Not
omply
Not
servable
Not
pplicable
# Framing / Rvugh-In
& Req.ID Inspection
Verified Verified
Value Value Complies? Comments/Assumptions
403.3.7
Ducts declared to be within the
[FR28]3
conditioned space are either 1)
completely within the
continuous air barrier and within
the building thermal envelope,
2) buried within ceiling
insulation in accordance with
Section R403.3.6 and the air
handler is located completely
within the continuous air barrier
and within the building thermal
envelope and the duct leakage
is <= 1.5 cfm / 100 square feet
of conditioned floor area served
by the duct system, or 31 the
ceiling insulation R-value
installed against and above the
insulated duct --= to the
I
proposed ceiling insulation R-
value, less the R value of the
insulation on the duct.
403.4
HVAC piping conveying fluids
105 -F or chilled fluids
[FR17]2
above
below 55 °F are insulated to >_R-
3.
403.4.1 Protection of insulation on HVAC
[FR24]1 piping.
403.5.3 Hot water pipes are insulated to
[FR18]2 >_R-3.
I
403.6 Automatic or gravity dampers
(FR19]2 are installed on all outdoor air
intakes and exhausts.
303.1.3 U-factors of fenestration
[FR4]1 products are determined in
accordance with the NFRC test
procedure or taken from the
default table.
Additional Comments/Assumptions:
Complies
PoDoesNot
omply
PNot
servable
Not
Applicable
R�= R-j= ❑ Complies
O Does Not
Comply
Not
O servable
0 Not
Applicable
Complies
Does Not
Comply
qNot
O servable
Not
Applicable
0 Complies
R� R� Does Not
Comply
Not
O servable
O Not
Applicable
Complies
Does Not
omply
Not
O servable
Not
Applicable
Complies
O Does Not
Comply
❑ Not
Observable
Q Not
Applicable
1 1 High Im act (Tier 1) 1 2 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3)
Report Title: DOCKERS CONSTRUCTION Report Date: 10/13/25, 8:15 AM 7 of 12
Insulation Inspection
Section
Plains
Field
#
Verified
Verified
& Req.lo
Insulation Inspection/
Value
Value
Complies?
comments/Assumptions
303.1
All installed insulation is labeled
Complies
y
[IN13]x
or the installed R-values
provided.
Does Not
1
omply
Not
servable
n Not
pplicable
402.1.1,
402.2.5,
Wall insulation R-value. If this is
a mass wall with at least 1h of
R —�
R
Complies
See the Envelope
Assemblies table for
402.2.6
the wall insulation on the wall
O Wood
0 Wood
Does Not
values
[IN3]1
exterior, the exterior n
mply
requirement applies (FRIG).
Mass
O Mass
Qo Not
Steel
O Steel
Observable
Not
pplicable
303.2
Wall insulation Is installed per
Complies
[IN4]1
manufacturer's instructions.
(�] Does Not
Comply
Not
servable
Not
pplicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 _ Medium Impact (Tier 2) 1 3 Low Impact (Tier 3)
Final
inspection Provisions
' Section
i Plans
Field
#p
Verified
Verified
& Req.ID
Final Inspection Provisions Value
Value
Complies?
402.1.1,
Ceiling insulation R-value. R=
RL
❑ Complies
402.2.1,
402.2.2,
❑ Wood
_�
❑ Wood
Does Not
Comply
[FI1]1 2 6
❑ Steel
❑ Steel
Not
RO
servable
❑ Not
Applicable
Comments/Assumptions
See the Envelope
Assemblies table for
values
303.1.1.1.
Ceiling insulation installed per
instructions.
❑ Complies
303.2
[FI211
manufacturer's
Blown insulation marked every
❑Does Not
Comply
py
300ft2.
Not
O servable
❑ Not
Applicable
403.1.2
Heat pumpthermostat installed
❑ Complies
[FI10]2
on heat pumps.
Does Not
omply
(� Not
iObservable
❑ Not
Applicable
403.5.1
Circulating service hot water
❑ Complies
[Flll]2
systems have automatic or
accessible manual controls.
❑ Does Not
Comply
Not
O servable
❑ Not
Applicable
403.6.1
All mechanical ventilation
❑ Complies
[F125]2
system fans not part of tested
❑ Does Not
and listed HVAC equipment
meet efFicac and airflow limits
Comply
per Table R463.6.1.
❑ Not
Observable
❑ Not
Applicable
403.2
'Hot water boilers supplying heat
❑ Complies
[FI2612
through one- or two -pipe
heating systems have outdoor
Does Not
setback control to lower boiler
Comply
water temperature based on
Not
outdoor temperature.
servable
❑ Not
i
Applicable
403.5.1.1
Heated water circulation
0 Complies
[F[28]2
systems have a circulation
Does Not
pump. The system return pipe is
Comply
a dedicated return pipe or a
cold water supply pipe. Gravity
(� Not
and thermos -syphon circulation
O servable
Systems are not present.
Controls for circulating hot
❑Not
water system pumps start the
Applicable
pump with signal for hot water
demand within the occupancy.
Controls automatically turn off
the pump when water is in
circulation loop is at set -point
temperature and no demand for
hot water exists.
403.5.1.2
Electric heat trace systems
UL
❑ Complies
[F129]2
comply with IEEE 515.1 or
515. Controls automatically
Does Not
adjust the energy input to the
omply
heat tracing to maintain the
[� Not
desired water temperature in
O servable
the piping.
i❑Not
Applicable
Report Title: DOCKERS CONSTRUCTION Report Date: 10/13/25, 8:15 AM 9 of 12
Section
& Req.ID
Final Inspection Provisions
403.5.2
Demand recirculation water
[F130]2
systems have controls that
manage operation of the pump
and limit the temperature of the
water entering the cold water
piping to <= 1042F
Plans Field
Verified Verified
Value Value
403.5.4
Drain water heat recovery units
[FI3112
tested in accordance with CSA
B55.1. Potable water -side
pressure loss of drain water
heat recovery units < 3 psi for
Individual units connected to
one or two showers. Potable
water -side pressure loss of drain
water heat recovery units < 2
psi for individual units
connected to three or more
showers.
403.10.1
Readily accessible switch on
[Fi12]3
heaters for swimming pools or
permanent in -ground spas.
Switch operation does not
change heater thermostat
setting. Heater circuit breaker is
installed independent of switch.
Gas -fired heaters equipped with
ignition pilots that are not
continuously burning pilots.
403.10.2
Timer switches or other
[Fllg]3
automatic preset schedule
control method are installed on
heaters and pumps serving
pools and permanent
403.10.3
Outdoor heated pools and
[F120]3
outdoor permanent spas have a
vapor retardant cover.
404.1 90% or more of permanent
[FI6]1 fixtures have high efficacy
lamps.
404.1.1 Fuel gas lighting systems have
[FI23]3 no continuous pilot light.
401.3 Compliance certificate posted.
[ F[7]2
303.3 Manufacturer manuals for
[F]18]3 mechanical and water heating
systems have been provided.
Complies?
Complies
PDoes Not
omply
R Not
servable
Not
pplicable
Complies
Does Not
omply
Not
servable
Not
pplicable
Complies
PDoes Not
omply
WObNot
servable
Not
pplicable
O Complies
PDoes Not
omply
WObNot
servable
Not
pplicable
Q Complies
PDoes Not
omply
Ob Not
servable
Not
pplicable
Complies
PDoes Not
omply
Ob Not
servable
Not
pplicable
0 Complies
PDoes Not
omply
Not
servable
Not
pplicable
Complies
Does Not
omply
Not
servable
Not
pplicable
0 Complies
[�] Does Not
Comply
Not
servable
Not
pplicable
Comments/Assumptions
& Req.ID Final Inspection Provisions
Verified Verified
Value Value Complies? Comments/Assumptions
402.2.3 Vented attics with air permeable
insulation include baffle
Complies
[FI22]2
adjacent to soffit and eave
Does Not
vents that extends over
omply
insulation.
Not
servable
Q Not
Applicable
402.2.4
Attic access hatch and door R= R=
Complies
[FI311
insulation >_R-value of the
Does Not
adjacent assembly.
omply
+
f
Not
Observable
Not
Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5
ACH 50 = ACH 50 =
Complies
[FI17]1 ach In Climate Zones 1-2, and
o
O Does Not
<=3 ach in Climate Zones 3-8.
Comply
RNot
O servable
Not
Applicable
403.3.3 1 Ducts are pressure tested to
r-�
Q Complies
[FI2711 determine air leakage with i 2
either: Rough -in test: Total cfm/100 ft2
I ft2 2
cfm/ 10(
Does Not
leakage measured with a
Comply
pressure differential of 0.1 inch
Not
w.g. across the system including
servable
the manufacturer's air handler
enclosure if installed at time of
Not
test. Postconstruction test: Total
pplicable
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
Including the manufacturer's air
ha ndIer enclosure.
403.3.4
Duct tigqhtness test result of
Complies
[FI411
<=4 cfm/100 ft2 across the
system or <=3 cfm/100 ft2 cfm/100 ft2
Does Not
cfm/100 ft2
without air handier @ 25 Pa. For
omply
rough -in tests, verification may
(-] Not
need to occur during Framing
O servable
Inspection.
Not
Applicable
403.3.2.1 Air handler leakage designated Complies
[FI2411 by manufacturer at <�2 /o of Q Does Not
design air flow. Comply
Not
O servable
0 Not
Applicable
403.1.1 Programmable thermostats O Complies
[F[9]2 installed For control of primary
n Does Not
heating and cooling systems
Comply
and initially set by manufacturer
to Cade specifications. Not
WO servable
O Not
Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low impact (Tier 3)
Report Title: DOCKERS CONSTRUCTION Report Date: 10/13/25, 8:15 AM 11 of 12
2018 IECC Energy
LJ Efficiency
Certificate
Insulation Rating
R-Value
Above -Grade Wall
26.00
Below -Grade Wall
29.00
Floor
0.00
Ceiling / Roof
49.00
Ductwork (unconditioned spaces):
Glass & Door Rating
.
Window
0.26
Door
0.17
Skylight
0.00
CoolingHeating &
Heating System:
Cooling System:
Water Heater:
Signature
Name: Date:
Comments: