Loading...
HomeMy WebLinkAboutRescheck ReportREScheck*Web TM Compliance Certificate Project Information Project Title: Energy Code: Location: Construction Type: Project Type: Project Sub Type: Orientation: Conditioned Floor Area: Glazing Area: Climate Zone: Project No: All Electric: Is Renewable: Has Battery: Has Charger: Has Heat Pump Construction Site: 200 SADDLEBACK ROAD GARFIELD COUNTY, CO 81623 Project Notes: DOCKERS CONSTRUCTION 2018 IECC Garfield, Colorado Single Family New Construction None Bldg. faces 225 deg. from North 5251 ft2 16% 5b (8499 HDD) 1774048 false false false true true Owner/Agent: DAVID OCKERS DOCKERS CONSTRUCTION GLENWOOD SPRINGS, CO 81601 9709873527 DAV I D@ DOCKERSCONSTRUCTIO N.COM Designer/Contractor: BRADJORDAN PO BOX 1031 JORDAN ARCHITECTURE GLENWOOD SPRINGS, CO 81602 9706186690 BRADJORDANARCHITECT@GMAIL.COM ,Z Report Title: DOCKERS CONSTRUCTION Report Date: 10/13/25, 8:15 AM 1 of 12 Envelope Assemblies Assembly Gross Area or Perimeter Cavity R Value Cont. R Value Prop. U- Factor/ F-Factor Req. U- Factor/ F-Factor Prop. UA Req. UA Ceiling: Flat Ceiling or 3494 49.0 0.0 0.026 0.026 91 91 Scissor Truss Wall: Wood Frame, 16" o.c. 1464 20.0 6.0 0.042 0.060 54 78 Orientation: Front Window: Metal Frame w/ 145 0.260 0.300 38 44 Thermal Break Orientation: Front Door: Solid Door (under 24 0.166 0.300 4 7 50% glazing) Orientation: Front Wall 1: Wood Frame, 16" 1265 20.0 6.0 0.042 0.060 44 63 O.C. Orientation: Left side Window 1: Metal Frame w/ 188 0.260 0.300 49 56 Thermal Break Orientation: Left side Door 1: Solid Door (under 24 0.166 0.300 4 7 50% glazing) Orientation: Left side Wall 2: Wood Frame, 16" 1326 20.0 10.0 0.036 0.060 37 61 O.C. Orientation: Back Window 2: Metal Frame w/ 285 0.260 0.300 74 86 Thermal Break Orientation: Back Door 2: Glass Door (over 24 0.300 0.300 7 7 50% glazing) Orientation: Back Wall 3: Wood Frame, 16" 934 20.0 6.0 0.042 0.060 28 39 O.C. Orientation: Right side Window 3: Metal Frame w/ 125 0.260 0.300 33 38 Thermal Break Orientation: Right side Door 3: Solid Door (under 152 0.166 0.300 25 46 50% glazing) Orientation: Right side Basement Wall: Solid 594 19.0 10.0 0.030 0.050 17 28 Concrete or Masonry Orientation: Right side Wall height: 9.00 Insulation depth: 9.00' Insulation position: Integral Insulation Window: Metal Frame w/ 25 0.260 0.300 7 8 Thermal Break Orientation: Right side Basement Wall: Solid 472 19.0 10.0 0.030 0.050 13 22 Concrete or Masonry Orientation: Back Wall height: 9.00 Insulation depth: 9.00' Insulation position: Integral Insulation Window 1: Metal Frame w/ 25 0.260 0.300 7 8 Thermal Break Orientation: Back Prop. Keq. Assembly Gross Area or Cavity Cont. U- U- Prop. Req. Perimeter R Value R Value Factor/ Factor/ ILIA UA F-Factor F-Factor Basement Wall: Solid 594 Concrete or Masonry Orientation: Left side Wall height: 9.00 Insulation depth: 8.00' Insulation position: Integral Insulation Basement Wall: Solid 472 Concrete or Masonry Orientation: Front Wall height: 9.00 Insulation depth: 8.00' Insulation position: Integral Insulation 19.0 10.0 0.034 0.050 20 30 19.0 10.0 0.034 0.050 16 24 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Slab -on -grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab -on -grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Compliance Statement The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in REScheck Web and to comply with the mand re in the REScheck Inspection Checklist. Name - Title ure Date Report Title: DOCKERS CONSTRUCTION Report Date: 10113/25, 8:15 AM 3 of 12 r�(11 Inspection Checklist Energy Code: 2018 IECC Requirements: 0% were addressed directly in the RESCheCk software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Pre-Inspection/Plan Review Section Y Plans # Verified & Req.ID Pre-Inspection/Plan Review Value 103.1, Construction drawings and 103.2 documentation demonstrate [PR1]1 energy code compliance for the building envelope. Thermal envelope represented on construction documents. Field Verified Value Complies? 0 Complies omDoes Not ply PNot servable Not pplicable 103.11 103.2, Construction drawings and documentation demonstrate 0 Complies 403.7 energy code compliance For Does Not [PR3]1 lighting and mechanical Pmply systems. Systems serving multiple dwelling units must (� Not demonstrate compliance with i56servable the IECC Commercial Provisions. Not pplicable 302.1. 403.7 Heating and cooling equl ment is sized ACCA Manual S Heating: Btulhr Heating- 0 Complies [PR2]2 per based on loads calculated per ACCA Manual 1 Stulhr Does Not or other methods L� U Comply approved by the code official. Cooling: Stulhr Cooling: Btu/�hr � Not servable 0Not plicable Additional Comments/Assumptions: Comments/Assumptions 1 I High Impact (Tier 1} 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Foundation Inspection Section & Req.ID Foundation Inspection 303.2.1 A protective covering is [F01111' installed to protect exposed exterior insulation and extends a minimum of 6 in. below grade. 403.9 Snow- and ice -melting system (F01217 controls installed. Plans Field Verified Verified Value value complies? Comments/Assumptions O Complies Does Not amply Not servable Not pplicable D Complies Does Not omply Not servable O Not Applicable 402.1.1 Conditioned basement wall R��- R� Complies See the Envelope Assemblies table for [F04]1 insulation R-value. Where interior insulation is used, R= R Does Not i values amply verification may need to occur during Insulation Inspection. Not Not required in warm -humid servable locations in Climate Zone 3. Not 1pplicable 303.2 Conditioned basement wall [F0511 insulation installed per manufacturer's instructions. E) Complies Q Does Not amply Not servable Not pplicable 402.2.9 Conditloned basement wall ft ft 0 Complies See the Envelope [F06I1 insulation depth of burial or l� Does Not Assemblies table fior distance from top of wall. omply Ob Not servable 0 Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Report Title: DOCKERS CONSTRUCTION Report Date: 10/13/25, 8:15 AM 5 of 12 Framing / Rough -in inspection Section Plans # Framing / Rough -In Verified & Req.ID Inspection Value Field Verified Value Complies? Comments/Assumptions 402.3.4 Door U-factor. U v Complies See the Envelope [FR1]1 Does Not Comply Assemblies table for values Ob Not servable [ Not pplicable 402.1.1, 402.3.1, Glazing U-factor (area -weighted average). U= � Complies See the Envelope 402.3.3. Does Not Assemblies table for values 402.5 Comply [FR2]1 Not 6bservable Not pplicable 402.4.1.1 1 Air barrier and thermal barrier O Complies [FR23]1 installed per manufacturer's instructions. Does Not omply Not servable Not pplicable 402.4.3 [FR20]1 Fenestration that is not site built is listed and labeled as meeting Complies AAMA IWDMA/CSA Does Not 101/I.S.2/A440 or has infiltration omply rates per NFRC 400 that do not exceed code limits. [� Not 6bservable Not pplicable 402.4.5 [FR16]2 IC -rated recessed lighting 'fixtures sealed at Q Complies housing/interior finish and labeled Does Not to indicate s2.0 cfm omply leakage at 75 Pa. Not Qservable Not pplicable 403.3.1 Suppl and return ducts in attics Complies [FR12]1 insula ed >= R-8 witiEfe duct is >= 3 inches in diameter and Does Not >= R-6 where < 3 inches. omply Supply and return ducts in other portions of the building insulated Not Observable >= R-6 for diameter >= 3 inches and R-4.2 for < 3 [� Not inches in diameter. pplicable 403.3.2 [FR13]1 Ducts, air handlers and filter boxes are seated with � Complies I fointslseams compliant with International [—] Does Not Mechanical Code omply or International Residential Code, as applicable. [] Not Observable Not pplicable 403.3.5 Building cavities are not used as Complies [FR15]3 ducts or plenums. Does Not omply Not servable Not pplicable # Framing / Rvugh-In & Req.ID Inspection Verified Verified Value Value Complies? Comments/Assumptions 403.3.7 Ducts declared to be within the [FR28]3 conditioned space are either 1) completely within the continuous air barrier and within the building thermal envelope, 2) buried within ceiling insulation in accordance with Section R403.3.6 and the air handler is located completely within the continuous air barrier and within the building thermal envelope and the duct leakage is <= 1.5 cfm / 100 square feet of conditioned floor area served by the duct system, or 31 the ceiling insulation R-value installed against and above the insulated duct --= to the I proposed ceiling insulation R- value, less the R value of the insulation on the duct. 403.4 HVAC piping conveying fluids 105 -F or chilled fluids [FR17]2 above below 55 °F are insulated to >_R- 3. 403.4.1 Protection of insulation on HVAC [FR24]1 piping. 403.5.3 Hot water pipes are insulated to [FR18]2 >_R-3. I 403.6 Automatic or gravity dampers (FR19]2 are installed on all outdoor air intakes and exhausts. 303.1.3 U-factors of fenestration [FR4]1 products are determined in accordance with the NFRC test procedure or taken from the default table. Additional Comments/Assumptions: Complies PoDoesNot omply PNot servable Not Applicable R�= R-j= ❑ Complies O Does Not Comply Not O servable 0 Not Applicable Complies Does Not Comply qNot O servable Not Applicable 0 Complies R� R� Does Not Comply Not O servable O Not Applicable Complies Does Not omply Not O servable Not Applicable Complies O Does Not Comply ❑ Not Observable Q Not Applicable 1 1 High Im act (Tier 1) 1 2 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3) Report Title: DOCKERS CONSTRUCTION Report Date: 10/13/25, 8:15 AM 7 of 12 Insulation Inspection Section Plains Field # Verified Verified & Req.lo Insulation Inspection/ Value Value Complies? comments/Assumptions 303.1 All installed insulation is labeled Complies y [IN13]x or the installed R-values provided. Does Not 1 omply Not servable n Not pplicable 402.1.1, 402.2.5, Wall insulation R-value. If this is a mass wall with at least 1h of R —� R Complies See the Envelope Assemblies table for 402.2.6 the wall insulation on the wall O Wood 0 Wood Does Not values [IN3]1 exterior, the exterior n mply requirement applies (FRIG). Mass O Mass Qo Not Steel O Steel Observable Not pplicable 303.2 Wall insulation Is installed per Complies [IN4]1 manufacturer's instructions. (�] Does Not Comply Not servable Not pplicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 _ Medium Impact (Tier 2) 1 3 Low Impact (Tier 3) Final inspection Provisions ' Section i Plans Field #p Verified Verified & Req.ID Final Inspection Provisions Value Value Complies? 402.1.1, Ceiling insulation R-value. R= RL ❑ Complies 402.2.1, 402.2.2, ❑ Wood _� ❑ Wood Does Not Comply [FI1]1 2 6 ❑ Steel ❑ Steel Not RO servable ❑ Not Applicable Comments/Assumptions See the Envelope Assemblies table for values 303.1.1.1. Ceiling insulation installed per instructions. ❑ Complies 303.2 [FI211 manufacturer's Blown insulation marked every ❑Does Not Comply py 300ft2. Not O servable ❑ Not Applicable 403.1.2 Heat pumpthermostat installed ❑ Complies [FI10]2 on heat pumps. Does Not omply (� Not iObservable ❑ Not Applicable 403.5.1 Circulating service hot water ❑ Complies [Flll]2 systems have automatic or accessible manual controls. ❑ Does Not Comply Not O servable ❑ Not Applicable 403.6.1 All mechanical ventilation ❑ Complies [F125]2 system fans not part of tested ❑ Does Not and listed HVAC equipment meet efFicac and airflow limits Comply per Table R463.6.1. ❑ Not Observable ❑ Not Applicable 403.2 'Hot water boilers supplying heat ❑ Complies [FI2612 through one- or two -pipe heating systems have outdoor Does Not setback control to lower boiler Comply water temperature based on Not outdoor temperature. servable ❑ Not i Applicable 403.5.1.1 Heated water circulation 0 Complies [F[28]2 systems have a circulation Does Not pump. The system return pipe is Comply a dedicated return pipe or a cold water supply pipe. Gravity (� Not and thermos -syphon circulation O servable Systems are not present. Controls for circulating hot ❑Not water system pumps start the Applicable pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set -point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems UL ❑ Complies [F129]2 comply with IEEE 515.1 or 515. Controls automatically Does Not adjust the energy input to the omply heat tracing to maintain the [� Not desired water temperature in O servable the piping. i❑Not Applicable Report Title: DOCKERS CONSTRUCTION Report Date: 10/13/25, 8:15 AM 9 of 12 Section & Req.ID Final Inspection Provisions 403.5.2 Demand recirculation water [F130]2 systems have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to <= 1042F Plans Field Verified Verified Value Value 403.5.4 Drain water heat recovery units [FI3112 tested in accordance with CSA B55.1. Potable water -side pressure loss of drain water heat recovery units < 3 psi for Individual units connected to one or two showers. Potable water -side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 403.10.1 Readily accessible switch on [Fi12]3 heaters for swimming pools or permanent in -ground spas. Switch operation does not change heater thermostat setting. Heater circuit breaker is installed independent of switch. Gas -fired heaters equipped with ignition pilots that are not continuously burning pilots. 403.10.2 Timer switches or other [Fllg]3 automatic preset schedule control method are installed on heaters and pumps serving pools and permanent 403.10.3 Outdoor heated pools and [F120]3 outdoor permanent spas have a vapor retardant cover. 404.1 90% or more of permanent [FI6]1 fixtures have high efficacy lamps. 404.1.1 Fuel gas lighting systems have [FI23]3 no continuous pilot light. 401.3 Compliance certificate posted. [ F[7]2 303.3 Manufacturer manuals for [F]18]3 mechanical and water heating systems have been provided. Complies? Complies PDoes Not omply R Not servable Not pplicable Complies Does Not omply Not servable Not pplicable Complies PDoes Not omply WObNot servable Not pplicable O Complies PDoes Not omply WObNot servable Not pplicable Q Complies PDoes Not omply Ob Not servable Not pplicable Complies PDoes Not omply Ob Not servable Not pplicable 0 Complies PDoes Not omply Not servable Not pplicable Complies Does Not omply Not servable Not pplicable 0 Complies [�] Does Not Comply Not servable Not pplicable Comments/Assumptions & Req.ID Final Inspection Provisions Verified Verified Value Value Complies? Comments/Assumptions 402.2.3 Vented attics with air permeable insulation include baffle Complies [FI22]2 adjacent to soffit and eave Does Not vents that extends over omply insulation. Not servable Q Not Applicable 402.2.4 Attic access hatch and door R= R= Complies [FI311 insulation >_R-value of the Does Not adjacent assembly. omply + f Not Observable Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = Complies [FI17]1 ach In Climate Zones 1-2, and o O Does Not <=3 ach in Climate Zones 3-8. Comply RNot O servable Not Applicable 403.3.3 1 Ducts are pressure tested to r-� Q Complies [FI2711 determine air leakage with i 2 either: Rough -in test: Total cfm/100 ft2 I ft2 2 cfm/ 10( Does Not leakage measured with a Comply pressure differential of 0.1 inch Not w.g. across the system including servable the manufacturer's air handler enclosure if installed at time of Not test. Postconstruction test: Total pplicable leakage measured with a pressure differential of 0.1 inch w.g. across the entire system Including the manufacturer's air ha ndIer enclosure. 403.3.4 Duct tigqhtness test result of Complies [FI411 <=4 cfm/100 ft2 across the system or <=3 cfm/100 ft2 cfm/100 ft2 Does Not cfm/100 ft2 without air handier @ 25 Pa. For omply rough -in tests, verification may (-] Not need to occur during Framing O servable Inspection. Not Applicable 403.3.2.1 Air handler leakage designated Complies [FI2411 by manufacturer at <�2 /o of Q Does Not design air flow. Comply Not O servable 0 Not Applicable 403.1.1 Programmable thermostats O Complies [F[9]2 installed For control of primary n Does Not heating and cooling systems Comply and initially set by manufacturer to Cade specifications. Not WO servable O Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low impact (Tier 3) Report Title: DOCKERS CONSTRUCTION Report Date: 10/13/25, 8:15 AM 11 of 12 2018 IECC Energy LJ Efficiency Certificate Insulation Rating R-Value Above -Grade Wall 26.00 Below -Grade Wall 29.00 Floor 0.00 Ceiling / Roof 49.00 Ductwork (unconditioned spaces): Glass & Door Rating . Window 0.26 Door 0.17 Skylight 0.00 CoolingHeating & Heating System: Cooling System: Water Heater: Signature Name: Date: Comments: