HomeMy WebLinkAboutRescheck ReportB I��f rlj�� Coy C�(JREScheck*Web'" Compliance Certificate Project Information Project Title: fill scutter lane Energy Code: 2018 IECC Location: Rifle, Colorado Construction Type: Single Family Project Type: New Construction Project Sub Type: None Orientation: Bldg. faces 0 deg. from North Conditioned Floor Area: 1980 ft2 Glazing Area: 12% Climate Zone: 5b8HDD) Project No: 175828286 All Electric: false Is Renewable: false Has Battery: false Has Charger: false Has Heat Pump false Construction Site: Owner/Agent: Designer/Contractor: 611 scutter lane Mic Baca rifle , CO 81650 Studio M Engineers 970 366 8690 1 1 Project Notes: i Ins woo) 6,ec 1 MY1A Report Title: 611 scutter lane Report Date: 9/22/25, 9:09 AM 1 of 4 '4 Envelope Assemblies 40 7 Assembly Gross Area or Perimeter Cavity Cont. R-Valu R-Value Prop. U- Factor/ F-Factor Req. U- Factor/ F-Factor Prop. UA Req. UA Ceiling: Flat Ceiling or 1916 49.0 0.0 0.026 0.026 50 50 Scissor Truss WEST Foundation Wall: Solid 88 0.0 15'a 0.055 0.055 3 3 Concrete or Masonry 7 Wall height: 3.50 Depth below grade: 1.00 0 Insulation depth: 3.50' South Crawl Space Wall: 160 0.0 15.0 0.055 0.055 6 6 Solid Concrete or Masonry Wall height: 3.50 Depth below grade: 1.00 Insulation depth: 3.50' EAST Crawl Space Wall: Solid 88 0.0 15.0 0.055 0,055 3 3 Concrete or Masonry Wall height: 07 Depth below grade: 1.00 Insulation depth: 3.50' North Crawl Space Wall: 160 0.0 30.0 0.030 0.055 3 6 Solid Concrete or Masonry Wall height: 3.50 Depth below grade: 1.00 Insulation depth: 3.50' 1st Level EAST Wall: Wood 292 20.0 71 0.0 0.059 0.060 17 17 Frame, 16" o.c. Orientation: Left side 1st Level EAST Wall 9 0.300 0,300 3 3 Windows: Vinyl Frame Orientation: Left side 1st Level North Wall: Wood 537 20.0 0.0 0.059 0.060 27 27 Frame, 16" o.c. Orientation: Front 1st Level North Wall 59 0.300 0.300 18 18 Windows: Vinyl Frame Orientation: Front Door: Solid Door (under 50% 21 0.160 0.300 3 6 glazing) Orientation: Front 1st Level WEST Wall: Wood 292 20.0 0.0 0.059 0.060 17 17 Frame, 16" o.c. Orientation: Right side 1st Level WEST Wall 6 0.300 0.300 2 2 Windows: Vinyl Frame Orientation: Right side 1st Level South Wall: Wood 550 20.0 0.0 0.059 0.060 25 26 Frame, 16" o.c. Orientation: Back Window 1 Copy: Vinyl Frame 84 0.300 0.300 25 25 Orientation: Back Door: Glass Door (over 50% 40 0.300 0,300 12 12 glazing) Orientation: Back The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Slab -on -grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab -on -grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Report Title: 611 stutter lane Report Date: 9/22/25, 9:09 AM 2 of 4 Compliance Statement The proposed building design described here is consistent with the building plans. specifications, and other calculations submitted with the permit application, The proposed building has been designed to meet the 2018 IECC requirements in REScheck-Web and to comply with the mandatory requirements listed in the RE5check Inspection Checklist. Name - Title Signature Date Report Title: 611 stutter lane Report Date: 9/22/25, 9:09 AM 3 of 4 ON/,' 201 IECC En rgy Ef, ciency Certe cate Above -Grade Wall Below -Grade Wall Floor Ceiling / Roof Ductwork (unconditioned spaces): 20.00 30.00 0.00 49.00 r..SHGC Window 0.30 Door 0.30 Skylight 0.00 Efficiencv .Heating & Cooling Equipment Heating System: Cooling System: Water Heater: Name: Comments: Date: Report Title: 611 scutter lane Report Date: 9/22/25, 9:09 AM 4 of 4