Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Blower Door Test
Envelope Leakage Test =,T-E-C Testing Company: Technician: THE ENERGY CONSERVATORY Name: Name: Brian Chesney Address: Credentials: BPI Certified ID#5068969 Email: c5energygj@gmail.com Building Information: Project ID: 306 county rd 340 Address: 306 County Road 340 Parachute, Colorado 81635 Geo-Tag Data: Latitude: 39.460440 Longitude:-107.978523 Timestamp: 2025-12-18 09:38:57 Measured Leakage: 1.86 ACH50 Leakage Target: 3.00 ACH50 Compliance with Leakage Target: Pass Test I D: Purpose of Test: Measured CFM50: Building Volume: Coefficient (C): Test Standard: Test Characteristics: Test Date and Time: Blower door Envelope (IECC) 991.2 32,048.0 ft3 78.0 RESNET 380 One -Point Indoor Temp: 72 OF Altitude: 5,963.0 ft 2025-12-18 09:50:59 Customer Information: Name: Address: Effective Leakage Area: 54.5 in Enclosure Surface Area: 0.0 ft2 Exponent (n): 0.650 (assumed) Test Mode: Depressurize Outdoor Temp: 36 OF Time Average Period: 10 seconds 10% Adjustment Applied: No 2000 ■ Depressurize U 14TfiS m 600 _c 500 a) 400 300 v 200 m 100 4 5 6 7 8 910 20 30 40 50 60 Building Pressure (Pa) Envelope Leakage Test Test Readings: Target (Pa) Bldg_ft). Adj Bldg (Pa). Fan (Pa) Flow (cfm). Config Baseline -0.2 -50.0 -50.1 -49.9 -31.2 1,017.0 Ring A Test Equipment: Flow Device: Model 3 110V Fan Pressure Gauge: DG1000 Serial #: 13229 Calibration Date: 2024-08-27 Deviations from Standard: ■ None Comments: None Report by TEC Auto Test 1.10.2 (3), © 2025 The Energy Conservatory, Inc. Page 2 of 2