Loading...
HomeMy WebLinkAboutSGS_ 2507691 _FBND-0812S-0649_Shelter Drawings +FND_Rev 2_061325-signedTHE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. SHEET NUMBER SHEET TITLE GN-1 REVISION 2 I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF COLORADO REVISIONS 14708 CUSTER RD., SUITE 102 OMAHA, NE 68138 (402) 575-8885 FBND-0812S-0649 LANDFILL 8'-0" x 12'-0" PRECAST CONCRETE SHELTER DRAWINGS FBND-0812S-0649 SGS# : 2507691 REV.DATE ISSUED FOR CONSTRUCTION DESCRIPTION NJS004/24/25 QA TJ BY REVISION NJS105/12/25 TJ REVISION NJS206/13/25 AK GENERAL NOTES CELLSITE SHELTER KEY D A B C H E F G DRAWINGS ARE BASE OFF SHELTER REFERENCE DRAWING # 1.BY FIBERBOND, DRAWING # D-3539 DATED 02/11/97. REFER TO DRAWINGS # D-3539 FOR ANY OTHER DETAILS THAT ARE NOT LISTED IN THESE SETS. DRAWING INDEX SHEET DESCRIPTION ALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR 11X17. CONTRACTOR SHALL VERIFY ALL PLANS, EXISTING DIMENSIONS, CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT OR ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR THE SAME. GN-1 EXTERIOR ELEVATION FACE AC-1 EXTERIOR ELEVATION FACE BC-2 EXTERIOR ELEVATION FACE C FLOOR PLAN LAYOUT CABLE TRAY DETAILS C-3 C-4 C-5 C-6 C-7 C-8 PANEL SCHEDULE GENERAL NOTES C-9 C-12 EXTERIOR ELEVATION FACE D C-11 FLOOR PLAN - CABLE TRAY FLOOR PLAN - HVAC HVAC DETAILS C-13 LED DETAILS FLOOR PLAN - LIGHTING DESIGN C-14 SURGE DETAILS C-15 C-10 INTERIOR ELEVATION FACE E INTERIOR ELEVATION FACE F INTERIOR ELEVATION FACE G INTERIOR ELEVATION FACE H C-16 C-17 C-18 C-19 DESIGN PARAMETERS REFERENCE EXISTING DRAWINGS 1.BY FIBERBOND, DRAWING #D-3539 DATED 02/11/97 SITE ID:FBND-0812S-0649 SITE NAME:LANDFILL ADDRESS:75-1/2 CO ROAD 246 RIFLE, CO 81650 FBND-0812S-0649 C-20 WIND DESIGN WIND SPEED:150 MPH GUST DURATION:3 SECONDS EXPOSURE:D GCpi:± 0.18 (PER ASCE 7) G-1 INTERIOR GROUND BAR DETAIL LOAD CENTER DETAILS PROJECT TEAM APPLICANT/CUSTOMER: CELLSITE SOLUTIONS, LLC 4150 C ST. SW CEDAR RAPIDS, IA 52404 PHONE: (319) 826-3404 ENGINEERING SERVICES: SGS TOWERS 14708 CUSTER RD, SUITE 102 OMAHA, NE 68138 CONTACT: JUSTIN STARY PHONE: 402.218.3471 EMAIL: justin.stary@sgstowers.com ONE CALL R Call before you dig. below.Know what's LOCATION PRIOR TO FOUNDATION INSTALL CONFIRM WITH CELLSITE PROJECT MANAGER @ 319-826-3404 FOR OVERALL SHELTER DIMENSION BEFORE INSTALL. DISCLAIMER ALL WORK SHALL BE PERFORMED, AND MATERIALS SHALL BE INSTALLED, IN ACCORDANCE WITH THE GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED AS PERMITTING WORK THAT DOES NOT CONFORM TO THESE CODES. COLORADO BUILDING CODE ·2021 - INTERNATIONAL BUILDING CODE (ICC) ·2021 - INTERNATIONAL MECHANICAL CODE (IMC) CODE SUMMARY 2006 - 2021 (IBC) INTERNATIONAL BUILDING CODE. 1996 - 2023 (NEC) NATIONAL ELECTRICAL CODE. 2009 - 2021 (UMC) UNIFORM MECHANICAL CODE. 2006 - 2021 (IMC) INTERNATIONAL MECHANICAL CODE. 2007 - 2022 ASHRAE 90.1 2009 - 2021 (IECC) INTERNATIONAL ENERGY CONSERVATION CODE 2009 - 2024 (IFGC) INTERNATIONAL FUEL GAS CODE 2009 - 2021 (IFC) INTERNATIONAL FIRE CODE 2012 - 2024 NFPA 1 UNIFORM FIRE CODE WITH 2013 AMENDMENTS 2004 - 2018 CHICAGO BUILDING CODE. 2018 KENTUCKY BUILDING CODE. 2012 TENNESSEE BUILDING CODE 2018 MINNESOTA STATE BUILDING CODE. 2015 MINNESOTA STATE MECHANICAL CODE. (CH. 1346 - 2012 IMC & 2012 IFCG W/AMEND) 2015 MINNESOTA ENERGY BUILDING CODE(CH. 1323) 2015 NEW MEXICO COMMERCIAL BUILDING CODE. 2017 NEW MEXICO ELECTRICAL CODE 2015 NEW MEXICO MECHANICAL CODE 2012 MICHIGAN BUILDING CODE 2012 MICHIGAN MECHANICAL CODE 2011 MICHIGAN ELECTRICAL CODE 2019 CALIFORNIA BUILDING CODE 2019 CALIFORNIA GREEN BUILDING STANDARDS 2019 CALIFORNIA ENERGY CODE TITLE 24 2019 CALIFORNIA ELECTRICAL CODE 2019 CALIFORNIA FIRE CODE CALIFORNIA TITLE 25 2010 NEW YORK CITY BUILDING CODE NORTH DAKOTA ELECTRICAL WIRING STANDARDS 2017 FLORIDA BUILDING CODE 2017 FLORIDA BUILDING CODE MECHANICAL 2017 FLORIDA BUILDING CODE FUEL GAS 9TH MASSACHUSETTS STATE BUILDING CODE 2019 OREGON STRUCTURAL SPECIALTY CODE 2019 OREGON MECHANICAL SPATIALITY CODE 2019 OREGON ENERGY EFFICIENCY SPECIALTY CODE 2018 NORTH CAROLINA BUILDING CODE 2017 NORTH CAROLINA ELECTRICAL CODE 2018 NORTH CAROLINA MECHANICAL CODE WITH AMENDMENTS 2018 NORTH CAROLINA ENERGY CONSERVATION CODE 2012 TEXAS ACCESSIBILITY STANDARDS 2002 ARKANSAS FIRE PREVENTION CODE 2018 NORTH CAROLINA FIRE CODE 2015 RHODE ISLAND FIRE SAFETY CODE NOTES 1.LISTED CODES INCLUDES LATEST STATE ADOPTED AMENDMENTS AND APPENDICES. 2.THIS SHELTER IS AN "ENCLOSED STRUCTURE" NOT INTENDED FOR HUMAN HABITATION. 3.APPROVED MODEL MAY BE MIRROR IMAGE. 4.OCCUPANT LOAD = 0, OHIO = 2. THIS BUILDING SHALL BE OCCUPIED FOR SERVICING EQUIPMENT AND MAINTENANCE ONLY. 5.SPECIAL CONDITIONS AND PERMISSIBLE TYPES OF GASSES; N/A 6.SHELTER HAS NO COUNTY PLACEMENT RESTRICTION IN THE STATE OF MARYLAND. 7.STATE INSIGNIA LABEL/DECAL IS LOCATED NEAR MAIN ELECTRICAL SERVICE PANEL. 8.DOOR MUST BE MINIMUM 90 MINUTE FIRE RATED, IF USED IN 2 HOUR FIRE RATED SHELTER AND MINIMUM 45 MINUTE FIRE RATED IF USING 1 HOUR FIRE RATED SHELTER. 9.ACCESS TO SHELTER SHALL COMPLY WITH MARYLAND ACCESSIBILITY CODE COMAR. 10.APPLICABLE INTERNAL PRESSURE COEFFICIENT(N/A)- THESE SHELTERS CONFIRM TO THE REQUIREMENTS OF (2000,03,06,09 IBC)' ASCE 7-05, METHOD 1 SIMPLIFIED PROCEDURE (2012,15 IBC, 2014 FBC) ASCE 7-10 SIMPLIFIED DIAPHRAGM LOW RISE BUILDING; (2018 IBC) ASCE 7-16 PART 2: LOW RISE BUILDING (SIMPLIFIED) 11.THESE PLANTS ARE DESIGNED TO BE USED FOR THE CONSTRUCTION OF COMMERCIAL MODULAR UNITS, IN ACCORDANCE WITH CA HEALTH AND SAFETY CODE SECTION 18028. 12.HVAC UNITS ARE SIZED TO ALLOW FOR MAX FUTURE EQUIPMENT CAPACITY AND HEAT LOADS WITHIN SHELTER WITH REDUNDANCY IN MIND. THEY ARE TO BE CONTROLLED TO STAGE UNITS BASED ON CURRENT LOAD. 13.EXTERNAL GROUNDING BY OTHERS. 14.SHELTER CONSTRUCTED IN ACCORDANCE WITH 61G20- 3.006. 15.THIS BUILDING DOES NOT CONTAIN PLUMBING FACILITIES, PLUMBING FACILITIES SHALL BE PROVIDED ON SITE SUBJECT TO THE LOCAL AUTHORITY HAVING JURISDICTION. 16.SPECIAL INSPECTION SHALL BE CONDUCTED BY AHJ OR THIRD PARTY INSPECTOR, APPROVED BY AHJ ON SITE PER IBC 1704.1, 1704, 1707 ON SEISMIC/WIND PROVISION FOR THE FASTENING/SECURING OF THE ELECTRICAL EQUIPMENT AND THE STRUCTURAL STEEL FASTENING/WELDING. 17.THIRD PARTY PLANT INSPECTIONS DO NOT INCLUDE UTILITY SERVICE CONNECTIONS, TIE-DOWN CONNECTIONS OR MULTI PIECE BUILDING SPLIT JOIN CONNECTIONS WHERE APPLICABLE. THESE ARE TO BE INSPECTED ON SITE. 18.CONNECTION TO PUBLIC UTILITIES TO BE PERFORM ON SITE BY OTHERS. EXTERIOR DIMENSIONS LENGTH:12'-0" WIDTH:8'-0" HEIGHT:10'-1" INTERIOR DIMENSIONS LENGTH:11'-312" WIDTH:7'-312" HEIGHT:8'-1112" ACCESS CONTROL DOOR DETAIL NTS EXTERIOR LIGHT DETAILS 06/16/2025 8'-4" 8'-0" EXTERIOR SHELTER 2"2" EXISTING GRADE CONCRETE SHELTER FOUNDATION 8' - 1 1 12" 9' - 1 0 " OV E R A L L S H E L T E R H E I G H T 6" 514" 1'-0" DOOR CANOPY (NOT REQUIRED) 52" COMPOSITE, 36"x52". CANOPY ASSY 54"x18" METAL 14GA 1 3'-0" 7" 7' - 2 " 2 4' - 1 " THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. SHEET NUMBER SHEET TITLE C-1 REVISION 2 I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF COLORADO REVISIONS 14708 CUSTER RD., SUITE 102 OMAHA, NE 68138 (402) 575-8885 FBND-0812S-0649 LANDFILL 8'-0" x 12'-0" PRECAST CONCRETE SHELTER DRAWINGS FBND-0812S-0649 SGS# : 2507691 REV.DATE ISSUED FOR CONSTRUCTION DESCRIPTION NJS004/24/25 QA TJ BY REVISION NJS105/12/25 TJ REVISION NJS206/13/25 AK 1SCALE: 3/8" = 1'-0" (11x17)EXTERIOR ELEVATION FACE A THESE EXISTING DRAWINGS WERE BASED UPON SPECIFIC INFORMATION PROVIDED BY THE CLIENT. SGS TOWERS IS NOT RESPONSOBLE FOR SHELTER DESIGN & DIMENSIONS. ORIGINAL SHELTER DESIGN DRAWINGS REFER TO GN-1 FOR MODEL & DRAWING #. DISCLAIMER EXTERIOR ELEVATION FACE A LIGHTING & ELECTRICAL DEVICE SYMBOLS SYMBOL DESCRIPTION QTY. MOUNTING LOCATION HEIGHT LED EXTERIOR WALL PACK LIGHT FIXTURES 1 EXTERIOR FACE A 7'-2" SP WATERPROOF BOX FOR ACCESS CONTROLS 1 EXTERIOR FACE A 4'-1" (CENTER) 1 2 06/16/2025 5'-0" 6' - 0 7 8" BO T T O M O F P L A T E 2 DOOR CANOPY (NOT REQUIRED) 52" COMPOSITE, 36"x52". CANOPY ASSY 54"x18" METAL 14GA 5' - 1 1 " ( T Y P . ) OV E R A L L H V A C H E I G H T 1 3' - 0 " 12'-4" 12'-0" EXTERIOR SHELTER 2"2" CONCRETE SHELTER FOUNDATION 8' - 1 1 12" 9' - 1 0 " OV E R A L L S H E L T E R H E I G H T 6" 514" 2'-0" EXISTING GRADE 2'-0" THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. SHEET NUMBER SHEET TITLE C-2 REVISION 2 I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF COLORADO REVISIONS 14708 CUSTER RD., SUITE 102 OMAHA, NE 68138 (402) 575-8885 FBND-0812S-0649 LANDFILL 8'-0" x 12'-0" PRECAST CONCRETE SHELTER DRAWINGS FBND-0812S-0649 SGS# : 2507691 REV.DATE ISSUED FOR CONSTRUCTION DESCRIPTION NJS004/24/25 QA TJ BY REVISION NJS105/12/25 TJ REVISION NJS206/13/25 AK 1SCALE: 1/2" = 1'-0" (11x17)EXTERIOR ELEVATION FACE B THESE EXISTING DRAWINGS WERE BASED UPON SPECIFIC INFORMATION PROVIDED BY THE CLIENT. SGS TOWERS IS NOT RESPONSOBLE FOR SHELTER DESIGN & DIMENSIONS. ORIGINAL SHELTER DESIGN DRAWINGS REFER TO GN-1 FOR MODEL & DRAWING #. DISCLAIMER EXTERIOR ELEVATION FACE B LIGHTING & ELECTRICAL DEVICE SYMBOLS SYMBOL DESCRIPTION QTY. MOUNTING LOCATION HEIGHT 3 TON BARD WALL MOUNT AC CONDITIONER (#W36-AC-A0ZXPXXXX)2 EXTERIOR FACE C 9'-1" (TOP) LED EXTERIOR WALL PACK LIGHT FIXTURES 1 EXTERIOR FACE A 7'-0" 1 CELLSITE SHELTER KEY D A B C H E F G 2 06/16/2025 1' - 1 1 14" 1 3' - 6 " 5' - 1 0 3 8" ( T Y P . ) OV E R A L L H V A C H E I G H T 2 8'-4" 8'-0" EXTERIOR SHELTER 2"2" EXISTING GRADE CONCRETE SHELTER FOUNDATION 8' - 1 1 12" 9' - 1 0 " OV E R A L L S H E L T E R H E I G H T 6" 51 4" THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. SHEET NUMBER SHEET TITLE C-3 REVISION 2 I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF COLORADO REVISIONS 14708 CUSTER RD., SUITE 102 OMAHA, NE 68138 (402) 575-8885 FBND-0812S-0649 LANDFILL 8'-0" x 12'-0" PRECAST CONCRETE SHELTER DRAWINGS FBND-0812S-0649 SGS# : 2507691 REV.DATE ISSUED FOR CONSTRUCTION DESCRIPTION NJS004/24/25 QA TJ BY REVISION NJS105/12/25 TJ REVISION NJS206/13/25 AK 1SCALE: 3/8" = 1'-0" (11x17)EXTERIOR ELEVATION FACE C THESE EXISTING DRAWINGS WERE BASED UPON SPECIFIC INFORMATION PROVIDED BY THE CLIENT. SGS TOWERS IS NOT RESPONSOBLE FOR SHELTER DESIGN & DIMENSIONS. ORIGINAL SHELTER DESIGN DRAWINGS REFER TO GN-1 FOR MODEL & DRAWING #. DISCLAIMER EXTERIOR ELEVATION FACE C CELLSITE SHELTER KEY D A B C H E F G LIGHTING & ELECTRICAL DEVICE SYMBOLS SYMBOL DESCRIPTION QTY. MOUNTING LOCATION HEIGHT GFCI DUPLEX RECEPTACLE, 20A, 125V, NEMA 5-20R, WITH WEATHERPROOF COVER PLATE MOUNTED VERTICALLY 1 EXTERIOR FACE C 18" ABOVE FLOOR 3 TON BARD WALL MOUNT AC CONDITIONER (#W36-AC-A0ZXPXXXX)2 EXTERIOR FACE C 9'-1" (TOP) 1 2 06/16/2025 5'-0" 6' - 0 7 8" BO T T O M O F P L A T E 2 DOOR CANOPY (NOT REQUIRED) 52" COMPOSITE, 36"x52". CANOPY ASSY 54"x18" METAL 14GA 5' - 1 1 " ( T Y P . ) OV E R A L L H V A C H E I G H T 1 3' - 0 " 12'-4" 12'-0" EXTERIOR SHELTER2"2" CONCRETE SHELTER FOUNDATION 8' - 1 1 12" 9' - 1 0 " OV E R A L L S H E L T E R H E I G H T 6" 514" 2'-0" EXISTING GRADE 2'-0" THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. SHEET NUMBER SHEET TITLE C-4 REVISION 2 I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF COLORADO REVISIONS 14708 CUSTER RD., SUITE 102 OMAHA, NE 68138 (402) 575-8885 FBND-0812S-0649 LANDFILL 8'-0" x 12'-0" PRECAST CONCRETE SHELTER DRAWINGS FBND-0812S-0649 SGS# : 2507691 REV.DATE ISSUED FOR CONSTRUCTION DESCRIPTION NJS004/24/25 QA TJ BY REVISION NJS105/12/25 TJ REVISION NJS206/13/25 AK EXTERIOR ELEVATION FACE D 1SCALE: 1/2" = 1'-0" (11x17)EXTERIOR ELEVATION FACE D THESE EXISTING DRAWINGS WERE BASED UPON SPECIFIC INFORMATION PROVIDED BY THE CLIENT. SGS TOWERS IS NOT RESPONSOBLE FOR SHELTER DESIGN & DIMENSIONS. ORIGINAL SHELTER DESIGN DRAWINGS REFER TO GN-1 FOR MODEL & DRAWING #. DISCLAIMER CELLSITE SHELTER KEY D A B C H E F G LIGHTING & ELECTRICAL DEVICE SYMBOLS SYMBOL DESCRIPTION QTY. MOUNTING LOCATION HEIGHT 3 TON BARD WALL MOUNT AC CONDITIONER (#W36-AC-A0ZXPXXXX)2 EXTERIOR FACE C 9'-1" (TOP) LED EXTERIOR WALL PACK LIGHT FIXTURES 1 EXTERIOR FACE A 7'-0" 1 2 06/16/2025 S 12'-0" EXTERIOR SHELTER 11'-312" INTERIOR SHELTER WALL 414" 8' - 0 " EX T E R I O R S H E L T E R 7' - 3 12" IN T E R I O R S H E L T E R W A L L 41 4" 414" 4 4 3' - 0 " TIE-DOWN CONNECTION PLATE 4 TOTAL (TYP.) ±2'-0" SITE PRO1 E1447 (4X4 PORT HOLES) 414" 3 3 S 3 3GF C I 1 2 5 6 SS THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. SHEET NUMBER SHEET TITLE C-5 REVISION 2 I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF COLORADO REVISIONS 14708 CUSTER RD., SUITE 102 OMAHA, NE 68138 (402) 575-8885 FBND-0812S-0649 LANDFILL 8'-0" x 12'-0" PRECAST CONCRETE SHELTER DRAWINGS FBND-0812S-0649 SGS# : 2507691 REV.DATE ISSUED FOR CONSTRUCTION DESCRIPTION NJS004/24/25 QA TJ BY REVISION NJS105/12/25 TJ REVISION NJS206/13/25 AK FLOOR PLAN LAYOUT 1SCALE: 3/8" = 1'-0" (11x17)FLOOR PLAN THESE EXISTING DRAWINGS WERE BASED UPON SPECIFIC INFORMATION PROVIDED BY THE CLIENT. SGS TOWERS IS NOT RESPONSOBLE FOR SHELTER DESIGN & DIMENSIONS. ORIGINAL SHELTER DESIGN DRAWINGS REFER TO GN-1 FOR MODEL & DRAWING #. DISCLAIMER LIGHTING & ELECTRICAL DEVICE SYMBOLS SYMBOL DESCRIPTION QTY. MOUNTING LOCATION HEIGHT 200AMP MAIN BREAKER, 120/240V SINGLE PHASE, 40 SPACE AC DISTRIBUTION PANELS 1 INTERIOR WALL E 4'-5" (CENTER) ACCESS CONTROL 1 INTERIOR WALL H 4'-5" (CENTER) 4' LED LIGHT FIXTURES 4 INSIDE SHELTER CEILING 9'-0" 3 TON BARD WALL MOUNT AC CONDITIONER (#W36-AC-A0ZXPXXXX)2 EXTERIOR FACE C 9'-1" (TOP) COMMSTAT 4 CONTROLLER FOR HVAC 1 INTERIOR WALL G 4'-5" (CENTER) 1 2 3 4 5 6 CELLSITE SHELTER KEY D A B C H E F G LIGHTING & ELECTRICAL DEVICE SYMBOLS SYMBOL DESCRIPTION QTY. MOUNTING LOCATION HEIGHT RED LED EXIT SIGN /EMERGENCY LIGHT 1 ABOVE ENTRANCE DOOR (INSIDE) INTERIOR FACE A 8'-2" DETECTOR SMOKE WITH JUNCT BOX, DETECTOR SMOKE, 120VAC, GENTEX, 7100F 1 INSIDE SHELTER CEILING 9'-0" SURGE SUPPRESSORS AND CONNECT TO MAIN BREAKER PANEL LIMIT CONDUCTOR LENGTH TO 10"1 INSIDE SHELTER NEXT TO PANEL 3'-2" (CENTER) DUPLEX RECEPTACLE, 20A, 125V, NEMA 5-20R, WITH COVERPLATE MOUNTED VERTICALLY 4 INTERIOR WALL E, F, G, & H 18" ABOVE FLOOR GFCI DUPLEX RECEPTACLE, 20A, 125V, NEMA 5-20R, WITH WEATHERPROOF COVER PLATE MOUNTED VERTICALLY 1 EXTERIOR FACE B 18" ABOVE FLOOR LED EXTERIOR WALL PACK LIGHT FIXTURES 1 EXTERIOR FACE A 7'-0" SINGLE POLE WALL LIGHT SWITCH BOX OCCUPANCY SENSOR 1 INTERIOR FACE E 48", UNO GROUND BUS BAR 2 INTERIOR WALL E & G BELOW ENTRY PORT S SS GFCI S 06/16/2025 S 11'-312" INTERIOR SHELTER WALL 1 3 4 7' - 3 12" IN T E R I O R S H E L T E R W A L L GF C I 5'-73 4"2'-97 8"2'-97 8" 1' - 7 116 " 1' - 1 1 11 16 " 3' - 9 116 " 1 1 1 4 4 4 S 1'-6"2'-2"2'-1"2'-2"2 2 2 2 SS THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. SHEET NUMBER SHEET TITLE C-6 REVISION 2 I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF COLORADO REVISIONS 14708 CUSTER RD., SUITE 102 OMAHA, NE 68138 (402) 575-8885 FBND-0812S-0649 LANDFILL 8'-0" x 12'-0" PRECAST CONCRETE SHELTER DRAWINGS FBND-0812S-0649 SGS# : 2507691 REV.DATE ISSUED FOR CONSTRUCTION DESCRIPTION NJS004/24/25 QA TJ BY REVISION NJS105/12/25 TJ REVISION NJS206/13/25 AK 1SCALE: 3/8" = 1'-0" (11x17)FLOOR PLAN - LIGHTING DESIGN THESE EXISTING DRAWINGS WERE BASED UPON SPECIFIC INFORMATION PROVIDED BY THE CLIENT. SGS TOWERS IS NOT RESPONSOBLE FOR SHELTER DESIGN & DIMENSIONS. ORIGINAL SHELTER DESIGN DRAWINGS REFER TO GN-1 FOR MODEL & DRAWING #. DISCLAIMER FLOOR PLAN - LIGHTING DESIGN CELLSITE SHELTER KEY D A B C H E F G LIGHTING & ELECTRICAL DEVICE SYMBOLS SYMBOL DESCRIPTION QTY. MOUNTING LOCATION HEIGHT DOUBLE DUPLEX RECEPTACLE (QUAD), 20A, 125V, NEMA 5-20R, WITH COVERPLATE MOUNTED VERTICALLY 4 INSIDE SHELTER CEILING 9'-212" (TOP) TWIST-LOCK (L5-30R), 30A, 120/240 V, WITH COVER PLATE MOUNTED VERTICALLY 4 INSIDE SHELTER CEILING 9'-212" (TOP) RED LED EXIT SIGN /EMERGENCY LIGHT 1 ABOVE ENTRANCE DOOR (INSIDE) INTERIOR FACE E 8'-2" 4' LED LIGHT FIXTURES 4 INSIDE SHELTER CEILING 9'-0" DETECTOR SMOKE WITH JUNCT BOX, DETECTOR SMOKE, 120VAC, GENTEX, 7100F 1 INSIDE SHELTER CEILING 9'-0" SURGE SUPPRESSORS AND CONNECT TO MAIN BREAKER PANEL LIMIT CONDUCTOR LENGTH TO 10"1 INSIDE SHELTER NEXT TO PANEL 3'-2" DUPLEX RECEPTACLE, 20A, 125V, NEMA 5-20R, WITH COVERPLATE MOUNTED VERTICALLY 4 INTERIOR WALL E, F, G, & H 18" ABOVE FLOOR GFCI DUPLEX RECEPTACLE, 20A, 125V, NEMA 5-20R, WITH WEATHERPROOF COVER PLATE MOUNTED VERTICALLY 1 EXTERIOR FACE C 18" ABOVE FLOOR LED EXTERIOR WALL PACK LIGHT FIXTURES 1 EXTERIOR FACE A 7'-0" SINGLE POLE WALL LIGHT SWITCH BOX OCCUPANCY SENSOR 1 INTERIOR FACE E 48", UNO 1 2 3 S SS GFCI S 4 06/16/2025 S 11'-312" INTERIOR SHELTER WALL 2 7' - 3 12" IN T E R I O R S H E L T E R W A L L GF C I 1 1 SS S THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. SHEET NUMBER SHEET TITLE C-7 REVISION 2 I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF COLORADO REVISIONS 14708 CUSTER RD., SUITE 102 OMAHA, NE 68138 (402) 575-8885 FBND-0812S-0649 LANDFILL 8'-0" x 12'-0" PRECAST CONCRETE SHELTER DRAWINGS FBND-0812S-0649 SGS# : 2507691 REV.DATE ISSUED FOR CONSTRUCTION DESCRIPTION NJS004/24/25 QA TJ BY REVISION NJS105/12/25 TJ REVISION NJS206/13/25 AK 1SCALE: 3/8" = 1'-0" (11x17)FLOOR PLAN - HVAC DESIGN THESE EXISTING DRAWINGS WERE BASED UPON SPECIFIC INFORMATION PROVIDED BY THE CLIENT. SGS TOWERS IS NOT RESPONSOBLE FOR SHELTER DESIGN & DIMENSIONS. ORIGINAL SHELTER DESIGN DRAWINGS REFER TO GN-1 FOR MODEL & DRAWING #. DISCLAIMER FLOOR PLAN - HVAC CELLSITE SHELTER KEY D A B C H E F G LIGHTING & ELECTRICAL DEVICE SYMBOLS SYMBOL DESCRIPTION QTY. MOUNTING LOCATION HEIGHT 3 TON BARD WALL MOUNT AC CONDITIONER (#W36-AC-A0ZXPXXXX)2 EXTERIOR FACE C 9'-1" (TOP) COMMSTAT 4 CONTROLLER FOR HVAC 1 INTERIOR WALL E 4'-5" (CENTER) JUNCTION BOXES 6 INTERIOR WALL G TBD SURGE SUPPRESSORS AND CONNECT TO MAIN BREAKER PANEL LIMIT CONDUCTOR LENGTH TO 10"1 INSIDE SHELTER NEXT TO PANEL 3'-2" (CENTER) DETECTOR SMOKE WITH JUNCT BOX, DETECTOR SMOKE, 120VAC, GENTEX, 7100F 1 INSIDE SHELTER CEILING 9'-0" 1 2 3 SS S 06/16/2025 2' - 1 0 " S 11'-312" INTERIOR SHELTER WALL 7' - 3 12" IN T E R I O R S H E L T E R W A L L GF C I 1' - 6 " 2' - 1 1 " 5'-2"1'-0"5'-2" SS S THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. SHEET NUMBER SHEET TITLE C-8 REVISION 2 I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF COLORADO REVISIONS 14708 CUSTER RD., SUITE 102 OMAHA, NE 68138 (402) 575-8885 FBND-0812S-0649 LANDFILL 8'-0" x 12'-0" PRECAST CONCRETE SHELTER DRAWINGS FBND-0812S-0649 SGS# : 2507691 REV.DATE ISSUED FOR CONSTRUCTION DESCRIPTION NJS004/24/25 QA TJ BY REVISION NJS105/12/25 TJ REVISION NJS206/13/25 AK 1SCALE: 3/8" = 1'-0" (11x17)FLOOR PLAN - CABLE TRAY THESE EXISTING DRAWINGS WERE BASED UPON SPECIFIC INFORMATION PROVIDED BY THE CLIENT. SGS TOWERS IS NOT RESPONSOBLE FOR SHELTER DESIGN & DIMENSIONS. ORIGINAL SHELTER DESIGN DRAWINGS REFER TO GN-1 FOR MODEL & DRAWING #. DISCLAIMER FLOOR PLAN - CABLE TRAY CELLSITE SHELTER KEY D A B C H E F G 06/16/2025 2 6" 4' - 5 " 8' - 1 1 12" CE I L I N G H E I G H T 1' - 6 " 7'-312" INTERIOR WALL 8' - 0 " 2'-11" 1 5 4' - 0 " 4 3 THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. SHEET NUMBER SHEET TITLE C-9 REVISION 2 I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF COLORADO REVISIONS 14708 CUSTER RD., SUITE 102 OMAHA, NE 68138 (402) 575-8885 FBND-0812S-0649 LANDFILL 8'-0" x 12'-0" PRECAST CONCRETE SHELTER DRAWINGS FBND-0812S-0649 SGS# : 2507691 REV.DATE ISSUED FOR CONSTRUCTION DESCRIPTION NJS004/24/25 QA TJ BY REVISION NJS105/12/25 TJ REVISION NJS206/13/25 AK 1SCALE: 1/2" = 1'-0" (11x17)INTERIOR ELEVATION FACE A THESE EXISTING DRAWINGS WERE BASED UPON SPECIFIC INFORMATION PROVIDED BY THE CLIENT. SGS TOWERS IS NOT RESPONSOBLE FOR SHELTER DESIGN & DIMENSIONS. ORIGINAL SHELTER DESIGN DRAWINGS REFER TO GN-1 FOR MODEL & DRAWING #. DISCLAIMER INTERIOR ELEVATION FACE E CELLSITE SHELTER KEY D A B C H E F G LIGHTING & ELECTRICAL DEVICE SYMBOLS SYMBOL DESCRIPTION QTY. MOUNTING LOCATION HEIGHT DUPLEX RECEPTACLE, 20A, 125V, NEMA 5-20R, WITH COVERPLATE MOUNTED VERTICALLY 1 INTERIOR WALL E 18" ABOVE FLOOR RED LED EXIT SIGN /EMERGENCY LIGHT 1 ABOVE ENTRANCE DOOR (INSIDE) INTERIOR FACE A 8'-2" 200AMP MAIN BREAKER, 120/240V SINGLE PHASE, 40 SPACE AC DISTRIBUTION PANELS 1 INTERIOR WALL E 4'-5" (CENTER) SINGLE POLE WALL LIGHT SWITCH BOX OCCUPANCY SENSOR 1 INTERIOR WALL E 48", UNO SURGE SUPPRESSORS AND CONNECT TO MAIN BREAKER PANEL (ONE PER ROOM) LIMIT CONDUCTOR LENGTH TO 10"1 INSIDE SHELTER NEXT TO PANEL 3'-2" (CENTER) 1 2 3 4 5 06/16/2025 9' - 0 " CE I L I N G H E I G H T 5'-8" 11'-312" INTERIOR SHELTER WALL 1 ENTRY PANEL (WAVEGUIDE) WALL OPENING 4'-10"1'-8" WALL OPENING 4'-10" 1' - 6 " THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. SHEET NUMBER SHEET TITLE C-10 REVISION 2 I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF COLORADO REVISIONS 14708 CUSTER RD., SUITE 102 OMAHA, NE 68138 (402) 575-8885 FBND-0812S-0649 LANDFILL 8'-0" x 12'-0" PRECAST CONCRETE SHELTER DRAWINGS FBND-0812S-0649 SGS# : 2507691 REV.DATE ISSUED FOR CONSTRUCTION DESCRIPTION NJS004/24/25 QA TJ BY REVISION NJS105/12/25 TJ REVISION NJS206/13/25 AK 1SCALE: 1/2" = 1'-0" (11x17)INTERIOR ELEVATION FACE B THESE EXISTING DRAWINGS WERE BASED UPON SPECIFIC INFORMATION PROVIDED BY THE CLIENT. SGS TOWERS IS NOT RESPONSOBLE FOR SHELTER DESIGN & DIMENSIONS. ORIGINAL SHELTER DESIGN DRAWINGS REFER TO GN-1 FOR MODEL & DRAWING #. DISCLAIMER INTERIOR ELEVATION FACE F CELLSITE SHELTER KEY D A B C H E F G LIGHTING & ELECTRICAL DEVICE SYMBOLS SYMBOL DESCRIPTION QTY. MOUNTING LOCATION HEIGHT DUPLEX RECEPTACLE, 20A, 125V, NEMA 5-20R, WITH COVERPLATE MOUNTED VERTICALLY 1 INTERIOR WALL F 18" ABOVE FLOOR1 06/16/2025 4' - 4 9 16 " 8' - 1 1 12" CE I L I N G H E I G H T 2 7'-312" INTERIOR WALL 89 16"2'-4116" 1' - 1 15 16 " 1' - 5 15 16 " 8116 " 1' - 3 116 " 3 3'-8" 1 1' - 6 " 1 THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. SHEET NUMBER SHEET TITLE C-11 REVISION 2 I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF COLORADO REVISIONS 14708 CUSTER RD., SUITE 102 OMAHA, NE 68138 (402) 575-8885 FBND-0812S-0649 LANDFILL 8'-0" x 12'-0" PRECAST CONCRETE SHELTER DRAWINGS FBND-0812S-0649 SGS# : 2507691 REV.DATE ISSUED FOR CONSTRUCTION DESCRIPTION NJS004/24/25 QA TJ BY REVISION NJS105/12/25 TJ REVISION NJS206/13/25 AK 1SCALE: 1/2" = 1'-0" (11x17)INTERIOR ELEVATION FACE C THESE EXISTING DRAWINGS WERE BASED UPON SPECIFIC INFORMATION PROVIDED BY THE CLIENT. SGS TOWERS IS NOT RESPONSOBLE FOR SHELTER DESIGN & DIMENSIONS. ORIGINAL SHELTER DESIGN DRAWINGS REFER TO GN-1 FOR MODEL & DRAWING #. DISCLAIMER INTERIOR ELEVATION FACE G CELLSITE SHELTER KEY D A B C H E F G LIGHTING & ELECTRICAL DEVICE SYMBOLS SYMBOL DESCRIPTION QTY. MOUNTING LOCATION HEIGHT 3 TON BARD WALL MOUNT AC CONDITIONER (#W36-AC-A0ZXPXXXX)2 EXTERIOR FACE C 9'-1" (TOP) DUPLEX RECEPTACLE, 20A, 125V, NEMA 5-20R, WITH COVERPLATE MOUNTED VERTICALLY 1 INTERIOR WALL G 18" ABOVE FLOOR COMMSTAT 4 CONTROLLER FOR HVAC 1 INTERIOR WALL G 4'-5" (CENTER) 1 2 3 06/16/2025 9' - 0 " CE I L I N G H E I G H T 4'-05 16" 11'-312" INTERIOR SHELTER WALL 1 ENTRY PANEL (WAVEGUIDE) WALL OPENING 4'-10"1'-8" WALL OPENING 4'-10" 4' - 5 " 2 12" DIA. EMT CONDUIT TYP. THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. SHEET NUMBER SHEET TITLE C-12 REVISION 2 I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF COLORADO REVISIONS 14708 CUSTER RD., SUITE 102 OMAHA, NE 68138 (402) 575-8885 FBND-0812S-0649 LANDFILL 8'-0" x 12'-0" PRECAST CONCRETE SHELTER DRAWINGS FBND-0812S-0649 SGS# : 2507691 REV.DATE ISSUED FOR CONSTRUCTION DESCRIPTION NJS004/24/25 QA TJ BY REVISION NJS105/12/25 TJ REVISION NJS206/13/25 AK 1SCALE: 1/2" = 1'-0" (11x17)INTERIOR ELEVATION FACE D THESE EXISTING DRAWINGS WERE BASED UPON SPECIFIC INFORMATION PROVIDED BY THE CLIENT. SGS TOWERS IS NOT RESPONSOBLE FOR SHELTER DESIGN & DIMENSIONS. ORIGINAL SHELTER DESIGN DRAWINGS REFER TO GN-1 FOR MODEL & DRAWING #. DISCLAIMER INTERIOR ELEVATION FACE H CELLSITE SHELTER KEY D A B C H E F G LIGHTING & ELECTRICAL DEVICE SYMBOLS SYMBOL DESCRIPTION QTY. MOUNTING LOCATION HEIGHT DUPLEX RECEPTACLE, 20A, 125V, NEMA 5-20R, WITH COVERPLATE MOUNTED VERTICALLY 1 INTERIOR WALL H 18" ABOVE FLOOR ACCESS CONTROL 1 INTERIOR WALL H 4'-5" (CENTER) 1 2 06/16/2025 THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. SHEET NUMBER SHEET TITLE C-13 REVISION 2 I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF COLORADO REVISIONS 14708 CUSTER RD., SUITE 102 OMAHA, NE 68138 (402) 575-8885 FBND-0812S-0649 LANDFILL 8'-0" x 12'-0" PRECAST CONCRETE SHELTER DRAWINGS FBND-0812S-0649 SGS# : 2507691 REV.DATE ISSUED FOR CONSTRUCTION DESCRIPTION NJS004/24/25 QA TJ BY REVISION NJS105/12/25 TJ REVISION NJS206/13/25 AK CABLE TRAY DETAILS 1SCALE: N.T.S.TYPICAL MOUNTING FOR CABLE RACK THESE EXISTING DRAWINGS WERE BASED UPON SPECIFIC INFORMATION PROVIDED BY THE CLIENT. SGS TOWERS IS NOT RESPONSOBLE FOR SHELTER DESIGN & DIMENSIONS. ORIGINAL SHELTER DESIGN DRAWINGS REFER TO GN-1 FOR MODEL & DRAWING #. DISCLAIMERMATERIAL LIST SR NO.QTY DESCRIPTION PART NO 1 4 SPLICE CLAMP 11188 2 12 BOLT 11173 3 14 NUT 11183 4 24 CORNER CLAMP 11189 5 12 BOLT 11172 6 10 4 1/2" KINDORF CHANNEL 10000 7 20 5/8" - 11 THREADED ROD 11635 8 20 SQUARE NUT - 5/8"10205 9 20 SQUARE WASHER 11519 10 20 BRACKET 11178 11 60 NUT TAP CON 11184 12 62 TAP CON 12909 13 4 18" CABLE RACK 11193 14 8 J - BOLT 11175 15 8 LOCK WASHER 11507 16 8 NUT 11470 17 4 END CAPS 22705 18 8 1s" X 1S" W" X 4" ANGLE 192777 19 6 21" UNISTRUT 10000 20 25 2- HOLE LUG W/ #6 WIRE 21023 21 20 PLASTIC PROTECTION CAP 22061 22 50 1/4" X 1" BOLT 11477 23 62 1/4" X 1" FENDER FLAT WASHER 11513 24 0 BRACKET, WALL CUP- 7/16" HOLE 11963 2 2 14 18 12 6 8 23 9 13 1 1 1 15 16 17 17 16 15 15 16 22 22 22 3 22 20 20 20 5 4 4 4 5 13 12 12 7 10 11 21 1110 11 7 21 11 18 15 16 15 16 1223 24 12 12 12 12 12 24 24 24 24 24 23 23 23 23 6 23 8 12 9 13 23 12 11 23 12 11 15 16 3 NOTES: 1.ALL CABLE TRAY MEASUREMENTS ARE ACCURATE WITHIN ± 1/4". 2.BOTTOM OF CABLE RACK TO BE MOUNTED 94" (CABLE RACK 2" HEIGHT) A.F.F. 3.CABLE TRAY SHALL NOT CAME IN CONTACT WITH ANY OTHER METAL PARTS IN SHELTER. 23 12 12 23 23 06/16/2025 THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. SHEET NUMBER SHEET TITLE C-14 REVISION 2 I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF COLORADO REVISIONS 14708 CUSTER RD., SUITE 102 OMAHA, NE 68138 (402) 575-8885 FBND-0812S-0649 LANDFILL 8'-0" x 12'-0" PRECAST CONCRETE SHELTER DRAWINGS FBND-0812S-0649 SGS# : 2507691 REV.DATE ISSUED FOR CONSTRUCTION DESCRIPTION NJS004/24/25 QA TJ BY REVISION NJS105/12/25 TJ REVISION NJS206/13/25 AK PANEL SCHEDULE 1SCALE: N.T.S. THESE EXISTING DRAWINGS WERE BASED UPON SPECIFIC INFORMATION PROVIDED BY THE CLIENT. SGS TOWERS IS NOT RESPONSOBLE FOR SHELTER DESIGN & DIMENSIONS. ORIGINAL SHELTER DESIGN DRAWINGS REFER TO GN-1 FOR MODEL & DRAWING #. DISCLAIMER R Call before you dig. below.Know what's ONE-LINE DIAGRAM & PANEL SCHEDULE 1 ONE-LINE DIAGRAM NOTES: 1.ALL GROUNDING TO CONFORM TO ARTICLE 250 OF THE NEC. 2.WIREWAYS CARRYING 3 OR MORE CURRENT CARRYING CONDUCTORS SHALL BE DERATED PER TABLE 310-15 (B) (3) (a) OF THE APPLICABLE EDITION OF THE NEC. 3.CONDUIT FILL IS BASED ON CHAPTER 9, APPENDIX C OF THE NEC. 4.INCLUD THE NEUTRAL TO GROUND BOND SCREW TO BE DONE ON SITE BY OTHERS. PANEL CIRCUIT & LOAD SCHEDULE (PER EQUIPMENT ROOM)- POWER PANEL (LC PP1) LOAD LOAD PER PHASE (VA) TR I P PO L E S WI R E S I Z E A. I . C . WI R E T Y P E WI R E T Y P E A. I . C . WI R E S I Z E PO L E S TR I P LOAD PER PHASE (VA) CKT. NO.DESCRIPTON QT Y . PHASE PHASE QT Y . DESCRIPTON CKT. NO.A B A B 1 HVAC #1 1 3288 40 2 8 10K THHN THHN 10K 8 2 40 3288 1 HVAC #2 2 3 3288 3288 4 5 SURGE PROTECTION DEVICE 1 180 30 2 8 10K THHN THHN 10K 10 2 20 15 1 POWER FAIL RELAY 6 7 180 15 8 9 LIGHTS 1 132 20 1 12 10K THHN THHN 10K 12 1 20 720 1 RECEPTACLES 10 11 SMOKE DETECTOR 1 45 20 1 12 10K THHN THHN 10K 12 1 20 180 1 GFCI 12 13 QUAD RECEPTACLES 1 1 720 20 1 12 10K THHN THHN 10K 12 1 20 720 1 QUAD RECEPTACLES 2 14 15 QUAD RECEPTACLES 3 1 720 20 1 12 10K THHN THHN 10K 12 1 20 720 1 QUAD RECEPTACLES 4 16 17 L5-30 TWISTLOCK RECEPTACLE 1 1 1500 30 1 10 10K THHN THHN 10K 12 1 30 1500 1 L5-30 TWISTLOCK RECEPTACLE 2 18 19 L5-30 TWISTLOCK RECEPTACLE 3 1 1500 30 1 10 10K THHN THHN 10K 12 1 30 1500 1 L5-30 TWISTLOCK RECEPTACLE 4 20 21 SPARE 2 SPARE 22 23 SPARE 3 SPARE 24 25 SPARE 4 SPARE 26 27 SPARE 5 SPARE 28 29 SPARE 1 SPARE 30 31 SPARE 1 SPARE 32 33 SPARE 1 SPARE 34 35 SPARE 1 SPARE 30 37 SPARE 1 SPARE 38 39 SPARE 1 SPARE 40 41 SPARE 1 SPARE 42 SUBTOTAL 5820 5733 6243 5703 SUBTOTAL VOLTAGE: 120 / 240 CYCLE: 60 WIRES: 3 12063 11436 TOTAL VA PER PHASE NEUTRAL: 200 AMPS 100.5 95.3 AMPS PER PHASE MAIN BREAKER: 200 AMP FRAME TRIP: 200 AMPS 23.5 TOTAL KVA MAIN LUGS: AMPS MAIN COPPER BUS: 200 AMPS MAIN: 42 BREAKERS TOP 06/16/2025 1/2" RIGID NIPPLE FOR CABLE ROUTING 4 SQ JUNCTION BOX ON INTERIOR SIDE FOR CONNECTION TO ACCESS CONTROL SYSTEM SG WEATHERPROOF BOX FOR CARD READER DRILL THROUGH WALL INTO DOOR FRAME FOR ELECTRIC STRIKE WIRING SG WEATHERPROOF BOX EXISTING GRADE EXISTING GRADE THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. SHEET NUMBER SHEET TITLE C-15 REVISION 2 I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF COLORADO REVISIONS 14708 CUSTER RD., SUITE 102 OMAHA, NE 68138 (402) 575-8885 FBND-0812S-0649 LANDFILL 8'-0" x 12'-0" PRECAST CONCRETE SHELTER DRAWINGS FBND-0812S-0649 SGS# : 2507691 REV.DATE ISSUED FOR CONSTRUCTION DESCRIPTION NJS004/24/25 QA TJ BY REVISION NJS105/12/25 TJ REVISION NJS206/13/25 AK SCALE: N.T.S. ACCESS CONTROL DOOR DETAIL NTS 2SCALE: N.T.S.ACCESS CONTROL DOOR DETAIL - WALL ELEVATION ACCESS CONTROL DOOR DETAIL - FRONT ELEVATION1SCALE: N.T.S.1SCALE: N.T.S. 06/16/2025 1SCALE: N.T.S.HVAC DETAILS THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. SHEET NUMBER SHEET TITLE C-16 REVISION 2 I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF COLORADO REVISIONS 14708 CUSTER RD., SUITE 102 OMAHA, NE 68138 (402) 575-8885 FBND-0812S-0649 LANDFILL 8'-0" x 12'-0" PRECAST CONCRETE SHELTER DRAWINGS FBND-0812S-0649 SGS# : 2507691 REV.DATE ISSUED FOR CONSTRUCTION DESCRIPTION NJS004/24/25 QA TJ BY REVISION NJS105/12/25 TJ REVISION NJS206/13/25 AK HVAC DETAILS 06/16/2025 1SCALE: N.T.S. THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. SHEET NUMBER SHEET TITLE C-17 REVISION 2 I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF COLORADO REVISIONS 14708 CUSTER RD., SUITE 102 OMAHA, NE 68138 (402) 575-8885 FBND-0812S-0649 LANDFILL 8'-0" x 12'-0" PRECAST CONCRETE SHELTER DRAWINGS FBND-0812S-0649 SGS# : 2507691 REV.DATE ISSUED FOR CONSTRUCTION DESCRIPTION NJS004/24/25 QA TJ BY REVISION NJS105/12/25 TJ REVISION NJS206/13/25 AK 1SCALE: N.T.S.EXTERIOR LIGHT DETAILS EXTERIOR LIGHT DETAILS 06/16/2025 1SCALE: N.T.S.LED DETAILS THESE EXISTING DRAWINGS WERE BASED UPON SPECIFIC INFORMATION PROVIDED BY THE CLIENT. SGS TOWERS IS NOT RESPONSOBLE FOR SHELTER DESIGN & DIMENSIONS. ORIGINAL SHELTER DESIGN DRAWINGS REFER TO GN-1 FOR MODEL & DRAWING #. DISCLAIMER THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. SHEET NUMBER SHEET TITLE C-18 REVISION 2 I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF COLORADO REVISIONS 14708 CUSTER RD., SUITE 102 OMAHA, NE 68138 (402) 575-8885 FBND-0812S-0649 LANDFILL 8'-0" x 12'-0" PRECAST CONCRETE SHELTER DRAWINGS FBND-0812S-0649 SGS# : 2507691 REV.DATE ISSUED FOR CONSTRUCTION DESCRIPTION NJS004/24/25 QA TJ BY REVISION NJS105/12/25 TJ REVISION NJS206/13/25 AK LED DETAILS 06/16/2025 1SCALE: N.T.S.SURGE DETAILS THESE EXISTING DRAWINGS WERE BASED UPON SPECIFIC INFORMATION PROVIDED BY THE CLIENT. SGS TOWERS IS NOT RESPONSOBLE FOR SHELTER DESIGN & DIMENSIONS. ORIGINAL SHELTER DESIGN DRAWINGS REFER TO GN-1 FOR MODEL & DRAWING #. DISCLAIMER THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. SHEET NUMBER SHEET TITLE C-19 REVISION 2 I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF COLORADO REVISIONS 14708 CUSTER RD., SUITE 102 OMAHA, NE 68138 (402) 575-8885 FBND-0812S-0649 LANDFILL 8'-0" x 12'-0" PRECAST CONCRETE SHELTER DRAWINGS FBND-0812S-0649 SGS# : 2507691 REV.DATE ISSUED FOR CONSTRUCTION DESCRIPTION NJS004/24/25 QA TJ BY REVISION NJS105/12/25 TJ REVISION NJS206/13/25 AK SURGE DETAILS 06/16/2025 1SCALE: N.T.S.LOAD CENTER DETAILS THESE EXISTING DRAWINGS WERE BASED UPON SPECIFIC INFORMATION PROVIDED BY THE CLIENT. SGS TOWERS IS NOT RESPONSOBLE FOR SHELTER DESIGN & DIMENSIONS. ORIGINAL SHELTER DESIGN DRAWINGS REFER TO GN-1 FOR MODEL & DRAWING #. DISCLAIMER THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. SHEET NUMBER SHEET TITLE C-20 REVISION 2 I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF COLORADO REVISIONS 14708 CUSTER RD., SUITE 102 OMAHA, NE 68138 (402) 575-8885 FBND-0812S-0649 LANDFILL 8'-0" x 12'-0" PRECAST CONCRETE SHELTER DRAWINGS FBND-0812S-0649 SGS# : 2507691 REV.DATE ISSUED FOR CONSTRUCTION DESCRIPTION NJS004/24/25 QA TJ BY REVISION NJS105/12/25 TJ REVISION NJS206/13/25 AK LOAD CENTER DETAILS 06/16/2025 MASTER GROUND BAR BUILDING STEEL EMBED SECTION A-A #2 AWG GREEN WELDING CABLE TO BUILDING STEEL BUILDING STEEL EMBED W/ 3/8" x1 1/4" COUPLING P/N/ 223107 3/8" FLAT WASHER P/N/ 168031 3/8" BELLVILLE WASHER P/N/ 168120 3/8" COPPER HEX NUT P/N/ 168205 3/8" x 6" COPPER ALL THREAD P/N/ 168134 SINGLE HOLE #3 LUG P/N/ 400381 BUILDING STEEL EMBED W/ 3/8" x1 1/4" COUPLING P/N/ 223107 LUG, 1H, #3, BRN, 3/8" HOLE, FLARED LUG,2H,#3 BRN,3/8" BOLT, 1" C/C, LBFW WIRE, #3 SOLID COPPER, BARE, TINNED LUG,2H,#1 GRN,3/8" HOLE, 1" C/C, LBFW G-BAR, GALV, 4"x12"x1/4", ANTI-THEFT WIRE, #3 THHN, STRAND, GRN G-BAR, GALV, 4"x12"x1/4", ANTI-THEFT VZ N S T E E L B A R DO N O T R E C Y C L E VZ N S T E E L B A R DO N O T R E C Y C L E VZ N S T E E L B A R DO N O T R E C Y C L E VZ N S T E E L B A R DO N O T R E C Y C L E 1SCALE: N.T.S. THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. SHEET NUMBER SHEET TITLE G-1 REVISION 2 I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF COLORADO REVISIONS 14708 CUSTER RD., SUITE 102 OMAHA, NE 68138 (402) 575-8885 FBND-0812S-0649 LANDFILL 8'-0" x 12'-0" PRECAST CONCRETE SHELTER DRAWINGS FBND-0812S-0649 SGS# : 2507691 REV.DATE ISSUED FOR CONSTRUCTION DESCRIPTION NJS004/24/25 QA TJ BY REVISION NJS105/12/25 TJ REVISION NJS206/13/25 AK INTERIOR GROUND BAR DETAIL INTERIOR GROUND BAR DETAIL 06/16/2025 1' - 6 " 8' - 0 " OU T T O O U T C O N C R E T E F O U N D A T I O N #4 B E N T B A R S P A C E @ A B T . 2 4 " = 5 ' - 0 " (5 E A C H S H O R T S I D E , 10 T O T A L ) 12'-0" OUT TO OUT CONCRETE FOUNDATION #4 BENT BAR SPACE @ ABT 24" = 9'-0" (6 EACH LONG SIDE, 12 TOTAL) 1'-6"1'-6" 1' - 6 " #4 HORZ. BARS (2 TOTAL PER SIDE) #4 CORNER BARS TOP & BOTTOM (12 TOTAL, 3 PER CORNER) 6" (TYP.) 6" (TYP.) 6" (T Y P . ) 6" (T Y P . ) 1' - 0 " FO O T I N G (T Y P . ) 3' - 0 " 6" 2' - 6 " 6" 1'-0" 6" CHAMFER (TYP.) EXCAVATE 6" OF EXISTING SOIL AND REPLACE WITH COMPACTED CRUSHED CLASS 5 ENGINEERED FILL UNDISTURBED SOIL 3 4" x 45° CHAMFER (TYP.) #4 HORZ. BARS @ ABT. 12" SPACING (3 TOTAL PER SIDE) FINISH GRADE #4 BENT BARS @ 24" SPACING 12'-0" OUT TO OUT CONCRETE SLAB 6" THK. CONCRETE SLAB 3" CLR. 3" CLR. #4 BAR SPACE @ ABT 24" = 11'-6" HORIZONTAL & VERTICAL 7 TOTAL 12" EXPANSION JOINT 3" CL R . 5'-0" x 6'-0" X 11" THK CONCRETE STOOP. #4 HORZ. BARS @ ABT 12" SPACING (14" SLOPE PER FOOT) FOOTING 12'-0" OUT TO OUT CONCRETE FOUNDATION #4 CORNER BARS (4 TOTAL, 1 PER CORNER) #4 BAR SPACE @ ABT. 24" = 11'-6" 7 TOTAL 3" CLR. 3" CLR. 8' - 0 " OU T T O O U T C O N C R E T E F O U N D A T I O N #4 B A R S P A C E @ A B T . 2 4 " = 7 ' - 6 " 6 T O T A L 3" CL R . 3" CL R . 12" EXPANSION JOINT 5'-0" x 6'-0" X 11" THK CONCRETE STOOP. #4 HORZ. BARS @ ABT 12" SPACING (14" SLOPE PER FOOT) 3 S- 1 6' - 0 " 3' - 4 " 73 4" 5'-012" THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. SHEET NUMBER SHEET TITLE NA REVISION 2 I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF COLORADO REVISIONS 14708 CUSTER RD., SUITE 102 OMAHA, NE 68138 (402) 575-8885 FBND-0812S-0649 LANDFILL 8'-0" x 12'-0" PRECAST CONCRETE SHELTER DRAWINGS FBND-0812S-0649 SGS# : 2507691 REV.DATE ISSUED FOR CONSTRUCTION DESCRIPTION NJS004/24/25 QA TJ BY REVISION NJS105/12/25 TJ REVISION NJS206/13/25 AK SHELTER FOUNDATION DESIGN SCALE: 1/2" = 1'-0" (11x17) 1SCALE: 1/4" = 1'-0" (11x17)2SHELTER FOUNDATION DESIGN - PLAN VIEW @ SLABSHELTER FOUNDATION DESIGN - PLAN VIEW @ FOOTING SCALE: 1/4" = 1'-0" (11x17) 3 NOTE: FOR ALL DETAILS SEE CONCRETE NOTES, ON SHEET S-2. SHELTER FOUNDATION DESIGN - ELEVATION VIEW (SECTION DETAIL) PRIOR TO FOUNDATION INSTALL CONFIRM WITH CELLSITE PROJECT MANAGER @ 319-826-3404 FOR OVERALL SHELTER DIMENSION BEFORE INSTALL & FROST DEPTH. THIS EXAMPLE SHOWS THE FROST DEPTH IN 2'-6" AREAS. CONFIRM WITH LOCAL CODES DISCLAIMER NOTE: CONTRACTOR SHALL CONTACT CELLSITE PROJECT MANAGER @ 319-826-3404 FOR STOOP LOCATION, SIZE & TYPES OF STOOP. 06/16/2025 UNIVERSAL LIFTING FOUNDATION SHELTER FLOOR WA L L 2'-412" (4)12"x12"x12" TIE DOWN PLATES 1'-0" 1' - 0 " 2" 4"4"2" 7" 4" 3"6"3" 3" (2) 15 16" DIAMETER HOLES (2) 1116" DIAMETER HOLES NEW 5 8" DIA. HILTI KWIK BOLT 3 (312" EMBEDMENT) 2 PER PLATE, 8 TOTAL) TIE DOWN BOLTS (2 PER PLATE, 8 TOTAL) TIE DOWN PLATE (SEE DETAIL BELOW) 1'-6" 2' - 6 " 2 " D I A . 2'-0" 2' - 0 " 2" DIA. BENT CORNER THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. SHEET NUMBER SHEET TITLE NA1 REVISION 2 I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF COLORADO REVISIONS 14708 CUSTER RD., SUITE 102 OMAHA, NE 68138 (402) 575-8885 FBND-0812S-0649 LANDFILL 8'-0" x 12'-0" PRECAST CONCRETE SHELTER DRAWINGS FBND-0812S-0649 SGS# : 2507691 REV.DATE ISSUED FOR CONSTRUCTION DESCRIPTION NJS004/24/25 QA TJ BY REVISION NJS105/12/25 TJ REVISION NJS206/13/25 AK CONCRETE & REINFORCING STEEL NOTES 1.AIR ENTRAINING ADMIXTURES SHALL CONFORM TO ASTM C260. 2.HOT WEATHER CONCRETE PLACEMENT SHALL COMPLY WITH ACI 305R. COLD WEATHER CONCRETE PLACEMENT SHALL COMPLY WITH ACI 306.1. 3.CONCRETE SHALL BE PLACED WITHIN 24 HOURS OF EXCAVATION INSPECTIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING EXPOSED EXCAVATIONS PRIOR TO CONCRETE PLACEMENT. 4.ALL WORK SHALL COMPLY WITH LOCAL CODES, SAFETY REGULATIONS AND UNLESS NOTED OTHERWISE, THE LATEST EDITION OF ACI 318 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE". 5.IF ANY FIELD CONDITIONS PRECLUDE COMPLIANCE WITH THE DRAWINGS AND/OR CONDITIONS SPECIFIED, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ENGINEER AND SHALL NOT PROCEED WITH ANY WORK THAT WOULD BE AFFECTED. 6.TAKE ALL MEASURES NECESSARY TO AVOID DAMAGING EXISTING REINFORCING BARS DURING DRILLING OPERATIONS. NOTIFY SGS TOWERS IMMEDIATELY IF EXISTING REINFORCING BARS ARE ENCOUNTERED AND INTERFERE WITH PROPOSED PAD EXTENSION. MINOR ADJUSTMENT TO PROPOSED LOCATION OF NEW ANCHORS MAY BE REQUIRED. 7.TEMPORARY REMOVAL/PERMANENT RELOCATION OF THE GROUND EQUIPMENT MAY BE REQUIRED. THE GC SHALL OBTAIN THE TOWER OWNER'S PERMISSION PRIOR TO TEMPORARY REMOVAL/PERMANENT RELOCATION. 8.CONTRACTOR SHALL EMPLOY ALL NECESSARY MEASURES TO PROTECT EXISTING STRUCTURES, FOUNDATIONS AND UTILITIES DURING EXCAVATION AND CONSTRUCTION OF THE FOUNDATIONS. 9.CONTRACTOR SHALL NOT UNDERCUT THE EXISTING FOUNDATION. 10.BACKFILL IS TO BE MADE IN LIFTS NOT TO EXCEED 8 INCHES. EACH LIFT IS TO BE COMPACTED TO A MINIMUM OF 110 PSF OR THE NET WEIGHT SPECIFIED IN THE GEOTECH REPORT AS DETERMINED BY ASTM D-698 SPECIFICATIONS USING VIBRATORY PLATE. EXCAVATED AREA TO HAVE A MINIMUM 6" MOUND ABOVE NATURAL GROUND SURFACE WHEN COMPLETED. NO FROZEN MATERIAL, LARGE ROCKS OR ORGANIC MATERIAL IS TO BE USED FOR BACKFILL. 11.REINFORCING STEEL SHALL BE DETAILED, FABRICATED, BENT AND PLACED IN ACCORDANCE WITH THE CRSI MANUAL OF STANDARD PRACTICE AND THE ACI 315 (LATEST EDITION). 12.SPACING DEVICES SHALL BE USED AS REQUIRED TO MAINTAIN THE SIDE AND BOTTOM CLEARANCE BETWEEN THE STEEL REINFORCEMENT AND EXCAVATION. 13.CONTRACTOR SHALL VERIFY ALL CONDITIONS, INCLUDING UNDERGROUND UTILITIES AND FIELD MEASUREMENTS AT JOB SITE AND REPORT ANY DISCREPANCIES TO ENGINEER BEFORE PROCEEDING WITH WORK. 14.DUE CARE SHALL BE EXERCISED DURING EXCAVATION SUCH THAT EXISTING UTILITIES ARE NOT DAMAGED. ANY BROKEN OR DAMAGED UTILITIES SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR. 15.ALL WATER SHALL BE REMOVED FROM THE BOTTOM OF THE EXCAVATION BEFORE PLACING CONCRETE. 16.ALL UNSUITABLE MATERIAL (BRICK FRAGMENTS, ASPHALT, CONCRETE BOULDERS, ETC.) WITHIN THE SLAB AREA AND EXCAVATION SHALL BE REMOVED FROM THE SITE. 17.CONCRETE WORK SHALL BE IN ACCORDANCE WITH ACI 301 AND ACI 318 AND THE SPECIFICATION FOR CAST IN PLACE CONCRETE. 18.ALL CONCRETE SHALL HAVE A MINIMUM OF 28-DAY COMPRESSIVE STRENGTH OF 4,000 PSI AIR CONTENT, AGGREGATE MAX SIZE OF AIR 3/4" OR LESS. 19.REINFORCING REBAR SIZE (SEE REINFORCING SCHEDULE FOR SIZE). 20.LOCATE ALL SLEEVES, OPENINGS, AND EMBEDDED ITEMS, ETC., AS INDICATED ON THE DRAWINGS. THE CONCRETE CONTRACTOR SHALL CHECK WITH OTHER TRADES TO MAKE SURE THE SLEEVES, OPENINGS, AND EMBEDDED ITEMS THAT ARE TO BE PROVIDED AND SET BY THEM ARE IN PLACE PRIOR TO PLACING OF CONCRETE IN THE AREA INVOLVED. 21.ALL EXPOSED CONCRETE EDGES SHALL HAVE A 3 4" X 45° CHAMFER. 22.COLD WEATHER CONCRETE: COLD WEATHER CONCRETE SHALL COMPLY WITH ACI 306. THE TEMPERATURE OF CONCRETE AT THE TIME OF MIXING SHALL BE NOT LESS THAN INDICATED IN THE FOLLOWING TABLE FOR CORRESPONDING OUTDOOR TEMPERATURE EXISTING AT THE TIME OF PLACEMENT. OUTDOOR TEMPERATURE CONCRETE TEMPERATURE BELOW 30°F 70°F BETWEEN 30°F AND 45°F 60°F ABOVE 45°F 45°F 23.WHEN DEPOSITED, THE TEMPERATURE OF HEATED CONCRETE SHALL NOT BE OVER 80°F. 24.WHEN FREEZING TEMPERATURES MAY BE EXPECTED DURING CURING PERIODS, SUITABLE MEANS SHALL BE PROVIDED FOR MAINTAINING THE CONCRETE AT TEMPERATURES OF NOT LESS THAN 50°F FOR 5 DAYS OR 70°F FOR 3 DAYS AFTER THE CONCRETE IS PLACED. CONCRETE AND ADJACENT FORM SURFACES SHALL BE KEPT MOIST AT ALL TIMES. SUDDEN COOLING OF CONCRETE WILL NOT BE PERMITTED. 25.THE CONTRACTOR SHALL USE CONCRETE WITH A MIX DESIGN VALUES IN LINE WITH PROJECT REQUIREMENTS. SUBMISSION AND ACCEPTANCE OF MIX DESIGN SHALL BE DONE IN THE PERIOD LEADING UP TO THE POUR TO ALLOW FOR PROPER REVIEW. VALUES SUCH AS SLUMP, STRENGTH, AND AIR CONTENT SHALL FALL WITHIN THE ACCEPTABLE GUIDELINES SET FORTH BY THE PROJECT DESIGN. 26.CONTRACTOR SHALL FOLLOW GUIDANCE ON BENCHING OR HANGING THE REBAR PRIOR TO THE POUR. VERIFY BAR THAT EXCEEDS THE COMPRESSIVE STRENGTH OF CONCRETE TO BE PLACED. 27.CONTRACTOR SHALL PLACE CONCRETE VIA A TREMIE PIPE OR LINE WHEN DROP HEIGHT EXCEEDS 5 FEET. SLUMP OF THE CONCRETE DURING THE PLACEMENT PROCESS SHOULD BE HIGH ENOUGH TO ENSURE PROPER FLOW AND DISTRIBUTION. IF HIGHER SLUMP VALUES ARE REQUIRED BEYOND THE RANGE SET FORTH BY THE PROJECT DESIGN, AN ADD MIXTURE SUCH AS SUPERPLASTIZER SHOULD BE ADDED ONSITE TO ACHIEVE GREATER WORKABILITY OF THE CONCRETE. REBAR SCHEDULE & NOTES 2REBAR SCHEDULE NOTES1 1UNIVERSAL LIFTING & TIE-DOWN PLATE REINFORCING SCHEDULE (QUANTITY FOR FOOTING & SLAB) QTY. REQ'D BAR SIZE DIA. (in.)LENGTH TYPE SHAPE FOOTING 6 #4 0.500 9'-4"STRAIGHT 6 #4 0.500 11'-4"STRAIGHT 22 #4 0.500 4'-0"BENT 12 #4 0.500 4'-0"CORNER SLAB 7 #4 0.500 9'-6"STRAIGHT 6 #4 0.500 11'-6"STRAIGHT 4 #4 0.500 4'-0"CORNER 06/16/2025