Loading...
HomeMy WebLinkAboutPlans5/8" Rebar & Yellow Plastic Cap Illegible 5/8" Rebar & Orange Plastic Cap LS No. 36572 Septic Tank Lid Electrical Outlet Shed Existing 2 Story Wood Frame House Covered Deck Concrete C o n c r e t e Gravel Driveway 50.52' Denver & Rio Gra n d e W e s t e r n R a i l r o a d Highway 6 & 24 (Main Street) Storm Grate 24" CMP 18" CMP Drainage Ditch PVC Water Meter Water Shut-off Gas Gr a v e l D r i v e Proposed Building 16.27' Fence Fence Fence Underground Gas Line (Yellow Paint marks) Block Retaining Wall Edge of Asphalt Northeast Corner Section 9 0.53 Acres ± Book 5 1 1 , Page 8 4 4 Power Pole (typical) Guy Wire (typical) Telephone Pedestal Overhead Utility Line 50.20' 10.20' 10.20' 12.04' 21.34' PROPERTY DESCRIPTION A PARCEL OF LAND SITUATED IN THE NE 1/4 NE 1/4 OF SECTION 9, TOWNSHIP 6 SOUTH, RANGE 92 WEST OF THE SIXTH P.M., LYING SOUTHERLY OF THE SOUTHERLY RIGHT OF WAY LINE OF U.S. HIGHWAY 6 & 24, WESTERLY OF THE WESTERLY LINE OF A COUNTY ROAD AS CONSTRUCTED AND IN PLACE, NORTHERLY OF THE NORTHERLY RIGHT OF WAY OF THE DENVER AND RIO GRANDE WESTERN RAILROAD AND EASTERLY OF A FENCE AS CONSTRUCTED AND IN PLACE, SAID PARCEL OF LAND IS DESCRIBED AS FOLLOWS: BEGINNING AT A POINT ON THE SOUTHERLY RIGHT OF WAY LINE OF SAID HIGHWAY WHENCE THE SECTION CORNER COMMON TO SECTIONS 3, 4, 9 AND 10 IN SAID TOWNSHIP AND RANGE BEARS N. 15 DEGREES 26' 15" E. 669.81 FEET; THENCE N. 89 DEGREES 46' 40" E. 155.28 FEET ALONG THE SOUTHERLY RIGHT OF WAY LINE OF SAID HIGHWAY; THENCE S. 00 DEGREES 38' 00" W. 157.88 FEET ALONG THE WESTERLY RIGHT OF WAY LINE OF SAID COUNTY ROAD; THENCE N. 85 DEGREES 22' 14" W. 151.09 FEET ALONG THE NORTHERLY RIGHT OF WAY LINE OF SAID RAILROAD; THENCE N. 01 DEGREES 09' 30" W. 145.10 FEET ALONG SAID FENCE TO A POINT ON THE SOUTHERLY RIGHT OF WAY LINE OF SAID HIGHWAY, THE POINT OF BEGINNING. SITE PLAN A PARCEL OF LAND SITUATED IN THE NE 1/4 NE 1/4 OF SECTION 9, TOWNSHIP 6 SOUTH, RANGE 92 WEST OF THE SIXTH P.M. COUNTY OF GARFIELD, STATE OF COLORADO 111 W Main Street, Silt, CO 81652 NOTES: 1.) THE DATE OF THE FIELD SURVEY WAS APRIL 17, 2024. 2.) THIS DOES NOT REPRESENT A TITLE SEARCH BY THIS FIRM OR SURVEYOR. 3.) THIS PROPERTY IS SUBJECT TO EASEMENTS, RIGHTS OF WAY AND/ OR REQUIREMENTS AS NOTED OR SHOWN IN THE RECORDS OF THE GARFIELD COUNTY CLERK & RECORDER. U.S. SURVEY FEET USED SURVEYOR'S CERTIFICATE I, SCOTT R. BLACKARD, DO HEREBY CERTIFY THAT I AM A PROFESSIONAL LAND SURVEYOR LICENSED UNDER THE LAWS OF THE STATE OF COLORADO, AND THAT THIS SURVEY IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. __________________________________ SCOTT R. BLACKARD P.L.S. 38342 email: sblackard11@gmail.com SITE PLAN A PARCEL OF LAND SITUATED IN THE NE 1/4 NE 1/4 OF SECTION 9, TOWNSHIP 6 SOUTH, RANGE 92 WEST OF THE SIXTH P.M. COUNTY OF GARFIELD, STATE OF COLORADO 111 W Main Street, Silt, CO 81652 H - Parking 19'-0" 1 4 ' - 0 " Concrete Apron 5/8" Rebar & Yellow Plastic Cap Illegible 5/8" Rebar & Orange Plastic Cap LS No. 36572 Septic Tank Lid Electrical Outlet Shed Existing 2 Story Wood Frame House Covered Deck Concrete C o n c r e t e Gravel Driveway 50.52' Denver & Rio Gra n d e W e s t e r n R a i l r o a d Highway 6 & 24 (Main Street) Storm Grate 24" CMP 18" CMP Drainage Ditch PVC Water Meter Water Shut-off Gas Gr a v e l D r i v e Proposed Building 16.27' Fence Fence Fence Underground Gas Line (Yellow Paint marks) Block Retaining Wall Edge of Asphalt Northeast Corner Section 9 0.53 Acres ± Book 5 1 1 , Page 8 4 4 Power Pole (typical) Guy Wire (typical) Telephone Pedestal Overhead Utility Line 50.20' 10.20' 10.20' 12.04' 21.34' PROPERTY DESCRIPTION A PARCEL OF LAND SITUATED IN THE NE 1/4 NE 1/4 OF SECTION 9, TOWNSHIP 6 SOUTH, RANGE 92 WEST OF THE SIXTH P.M., LYING SOUTHERLY OF THE SOUTHERLY RIGHT OF WAY LINE OF U.S. HIGHWAY 6 & 24, WESTERLY OF THE WESTERLY LINE OF A COUNTY ROAD AS CONSTRUCTED AND IN PLACE, NORTHERLY OF THE NORTHERLY RIGHT OF WAY OF THE DENVER AND RIO GRANDE WESTERN RAILROAD AND EASTERLY OF A FENCE AS CONSTRUCTED AND IN PLACE, SAID PARCEL OF LAND IS DESCRIBED AS FOLLOWS: BEGINNING AT A POINT ON THE SOUTHERLY RIGHT OF WAY LINE OF SAID HIGHWAY WHENCE THE SECTION CORNER COMMON TO SECTIONS 3, 4, 9 AND 10 IN SAID TOWNSHIP AND RANGE BEARS N. 15 DEGREES 26' 15" E. 669.81 FEET; THENCE N. 89 DEGREES 46' 40" E. 155.28 FEET ALONG THE SOUTHERLY RIGHT OF WAY LINE OF SAID HIGHWAY; THENCE S. 00 DEGREES 38' 00" W. 157.88 FEET ALONG THE WESTERLY RIGHT OF WAY LINE OF SAID COUNTY ROAD; THENCE N. 85 DEGREES 22' 14" W. 151.09 FEET ALONG THE NORTHERLY RIGHT OF WAY LINE OF SAID RAILROAD; THENCE N. 01 DEGREES 09' 30" W. 145.10 FEET ALONG SAID FENCE TO A POINT ON THE SOUTHERLY RIGHT OF WAY LINE OF SAID HIGHWAY, THE POINT OF BEGINNING. SITE PLAN A PARCEL OF LAND SITUATED IN THE NE 1/4 NE 1/4 OF SECTION 9, TOWNSHIP 6 SOUTH, RANGE 92 WEST OF THE SIXTH P.M. COUNTY OF GARFIELD, STATE OF COLORADO 111 W Main Street, Silt, CO 81652 NOTES: 1.) THE DATE OF THE FIELD SURVEY WAS APRIL 17, 2024. 2.) THIS DOES NOT REPRESENT A TITLE SEARCH BY THIS FIRM OR SURVEYOR. 3.) THIS PROPERTY IS SUBJECT TO EASEMENTS, RIGHTS OF WAY AND/ OR REQUIREMENTS AS NOTED OR SHOWN IN THE RECORDS OF THE GARFIELD COUNTY CLERK & RECORDER. U.S. SURVEY FEET USED SURVEYOR'S CERTIFICATE I, SCOTT R. BLACKARD, DO HEREBY CERTIFY THAT I AM A PROFESSIONAL LAND SURVEYOR LICENSED UNDER THE LAWS OF THE STATE OF COLORADO, AND THAT THIS SURVEY IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. __________________________________ SCOTT R. BLACKARD P.L.S. 38342 email: sblackard11@gmail.com SITE PLAN A PARCEL OF LAND SITUATED IN THE NE 1/4 NE 1/4 OF SECTION 9, TOWNSHIP 6 SOUTH, RANGE 92 WEST OF THE SIXTH P.M. COUNTY OF GARFIELD, STATE OF COLORADO 111 W Main Street, Silt, CO 81652 UP FLOOR PLAN SCALE 1'=1 4" A/C PAD STORAGE A A AA A A A A A A A A A A AA A A A A A A AA A A AA AAAA A A A A G1 G1 G1 G1 A A AA A A A D4 D4 D4D4 D3 D3 D3 D3 D3 C C C C G1G1G1G1 G1 G1 G1 G1 G1 G1 EF EF PS POWPAK MODULE #04 PS POWPAK MODULE #03 PS POWPAK MODULE #06 SM SMSM SM SM SM SM S1 S1 S1 D1 SD STSM SM ST 0-10V POWPAK MODULE #02 0-10V POWPAK MODULE #01 SW POWPAK MODULE #05 0-10V POWPAK MODULE #10 SW POWPAK MODULE #09 SW POWPAK MODULE #11 SW POWPAK MODULE #07 C1 C1 F2 C2C2 SW POWPAK MODULE #08 OS OS OS OS OS W OS OS W OS W OSW P2B P2B R/L Reeves & Sons Electric INC. 1560 Main St. PO Box 1198 Silt, CO 81652 970-876-0545 SCALE 1'=1/8" ISSUED FOR Review 3/13/2024 Permit 4/10/2024 EEVES ONS LECTRIC E 1 & SI T E P L A N 11 1 M A I N S T R E E T SI L T , C O L O R A D O Lighting notes: All lighting to be LED All office lights will be on occupancy sensors Exterior lights will be on a programmable time clock Hallway lighting to have motion sensors that also have built in daylight harvesting Upper mezzanine storage lights will be LED with motion sensors. All other storage areas will be on motion sensors Page 1 of 2 QUOTATION CUSTOMER INFORMATION:PROJECT INFORMATION: ROCKY MOUNTAIN STEEL STRUCTURES INC PO BOX 715 SILT, CO 81652-0715 Reeves ROCKY MOUNTAIN STEEL STRUCTURES INC DEFAULT - SC 117 EAST VISTA DRIVE SILT, CO 81652-8102 CONFIGURED BUILDING SECTION BLD NAME: Main BLD DIMENSIONS: 60 ft W X 80 ft L X 16 ft H DS 3:12 FINAL DRAWINGS NEEDED QUANTITY: ROOF MATERIAL: R38 - Multi-Layer White Energy Saver System R25 - 8" Cavity + R13 - 4 1/4" Overlay 5059 sf WALLS MATERIAL: R30 - 9 1/4" - Single Layer White Energy Saver System which includes 72, 60, 48, or 36 inch wide glass for Vertical Installation, insul-hold coils, thermal tape, banding, & screws 4860 sf *Please See Diagram Page for Wall Deduction Information BUILDING ACCESSORIES:QUANTITY: 3"X150' WHITE ENERGY SAVER PATCH TAPE (8) Main 1 RL CHARGES AND DISCOUNTS DESCRIPTION:VALUE: Freight Freight Allowed Fuel Surcharge $293.23 Prepared By:Scott Graff S.Graff@Silvercote.com SALES TAX:Not Included Sales Team:Scott Graff / Ricardo Myer www.Silvercote.com Phone: (844) 232-3701 Quote Date: 05/17/2024 Effective for Materials Shipping By: 07/09/2024 Quote #: DQ089220-1 Shipping Branch: Denver, CO (M19) Account #: 1751436 Page 2 of 2 IMPORTANT - PLEASE READ We accept responsibility for the accuracy of this estimate providing you sign above indicating that all dimensions, deductions, & material selections shown are correct. This quote does not include any applicable sales, use, excise or other taxes, tariffs, or duties that may be due with respect to this order. Tax will be Invoiced at time of shipment, and is the responsibility of each customer to pay the sales tax invoiced, unless a legal exemption applies. Silvercote; A Service Partners Company takes responsibility for the thermal performance of our insulation from design, to manufacturing the unfaced blanket, through lamination and delivery to your jobsite. Insulation products that fail to meet the intended R-value prior to installation will be replaced at our expense. For full details you can obtain a copy of our limited warranty on our website at ''www.silvercote.com''. Credit / Payment Terms: Subject to application approval executed by customer, including without limitation the Terms and Conditions of Sale included in such application. Finance charges are added to past due invoices. Additional payment methods include ACH, Debit Card, and Credit Card. Payments made by credit card are subject to a 3% processing fee at the time of payment. Accepted By: Date: TOTAL (USD):$19,841.86 Total Weight: 4593.59 Truckloads: 0.42 CUSTOMER:ROCKY MOUNTAIN STEEL STRUCTURES INC PROJECT NAME:Reeves ORDER NUMBER: DQ089220-1 BLD NAME: Main BLD DIMENSIONS: 60 ft W X 80 ft L X 16 ft H DS 3:12 FINAL DRAWINGS NEEDED >> Roofing Panels >> CUSTOMER:ROCKY MOUNTAIN STEEL STRUCTURES INC PROJECT NAME:Reeves ORDER NUMBER: DQ089220-1 BLD NAME: Main BLD DIMENSIONS: 60 ft W X 80 ft L X 16 ft H DS 3:12 FINAL DRAWINGS NEEDED >> SW #2 - 80ft. Long (Red Tag) >> 14'x14'@4 >> EW #2 - 60ft. Wide (Black Tag) >> >> SW #1 - 80ft. Long (Green Tag) >> 12'x12'@7 >> EW #1 - 60ft. Wide (Yellow Tag) >> Energy Saver Single Layer Sidewall to Energy Saver Roof © 2017 Silvercote, LLC SIL800-001 4/17 Eave strut Wall panel Roof panel Adhesive or tape Energy Saver fabric and banding Wall girt Thermal tape Double layer insulation Banding clip Metal angle (not provided) Roof system must be complete before wall connection can be made. Drawing not to scale WARNING Metal angle is not provided by Silvercote. Detail Area Adhesive or tape Energy Saver fabric and banding Adhesive or tape Full cavity insulation 4 2 1 3 5R25 Unfaced R25 Unfaced R13 Unfaced TM FOR NEW CONSTRUCTION silvercote.com SALES AND TECHNICAL SUPPORT - Customer Specific Support - Building Code Experts SERVICE - Centralized Operations - Energy Code Compliance RESEARCH AND DEVELOPMENT - Silvercote Envelope Solutions - New and Improved Systems and Accessories - Customer Training BEST IN CLASS MATERIALS - Certified Formaldehyde Free Ecose Technology QUOTING TOOL - 24/7 Online We strive to provide an exceptional customer experience on every order. If it’s important to you. It’s important to us! iQ WEB Please contact us for more information (844) 232-3701 or info@silvercote.com For more than 80 years Silvercote has partnered with customers in the metal building industry to provide innovative custom insulation solutions and systems. Silvercote is part of the Distribution International (DI) family of companies. Founded in 1986 Distribution International is a value-added distributor of insulation-related specialty fabricated products, HVAC products, and safety supplies in North America. Our Mission Silvercote designs custom insulation solutions that create value for our customers, employees and shareholders. We empower our employees to deliver what we promise to drive success. Avenel Houston Lubbock El Paso Albuquerque Spokane Montreal Scotia Denver Stockton Greenville Jackson Brampton Wright City Macedonia Marshfield Sioux Falls Dallas Brampton • Our premier system can meet or exceed IECC 2015 energy code requirements • Provides a clean and finished appearance of roofs and walls by hiding the purlins and girts • Improves acoustical performance compared to no insulation • When installed to Silvercote’s specifications provides a barrier to air leakage and contributes to a better airtight building • Silvercote’s fabric welding technology creates a continuous single custom sized fabric • Outer layer Insulation • Full Cavity insulation • Energy Saver fabric • Energy Saver banding Why Silvercote developed envelope solutions. Industry wide challenges in meeting increasingly stringent building codes are the driving force behind Silvercote Envelope Solutions for Energy Saver™. Energy Saver is designed to provide optimal overall energy performance for your building. We want to make complex building designs simple. We provide custom fabricated insulation and fabric, but also all necessary accessories and components to install your project correctly the first time. We strive to provide customized insulation to meet for your specific project needs. Energy Saver is the optimal Silvercote Envelope Solution! Silvercote Envelope Solutions createa continuous thermalbarrier. What is Energy Saver? Energy Saver can provide our highest R-value roof and wall envelope insulation system for new construction. It consists of a network of banding straps, a bright interior support fabric and unfaced ECOSE® glass mineral wool insulation creating a total building envelope. The Energy Saver system is designed primarily for use in metal buildings, but can also be used in the roof and wall for other types of building construction. Energy Saver FP provides OSHA-compliant leading edge fall protection. The roof system fabric is installed under the roof secondary structure and is supported by a banding grid system. ECOSE glass mineral wool insulation is installed in varying thickness between and across the purlins to obtain the desired insulating values. The Energy Saver wall system is offered in a single or double layer ECOSE glass mineral wool insulation system. Fabric is installed in the interior resulting in a bright finished wall appearance. 10 year limited warranty Improve productivity 71 percent of office workers list noise as a key impediment to productivity. In fact, noise pollution is a major environmental problem and exposure to excessive noise causes stress, poor concentration, productivity reduction, fatigue and loss of psychological well-being. ECOSE glass mineral wool insulation in walls, ceilings, floors and ducts significantly reduces the amount of noise inside buildings. Insulation products, specifically wall and ceiling insulations also reduce noise transfer from one room to another. Use Energy Saver Envelope in: • Manufacturing facilities • Aircraft hangers • Sports arenas • Retail locations Energy Saver Roof Energy Saver FP™ (OSHA-compliant leading edge fall protection) roof system fabric is installed under the roof secondary structure and is supported by a banding grid system. Unfaced glass mineral wool insulation is installed between and above the purlins in varying thickness combinations to obtain the desired insulating values.  Provides a continuous vapor retarder  Our Energy Saver fabric welding process produces seams that exceed the ASTMD-751 Standard of the fabric itself  Free online, Energy Saver Roof Fall Protection system training available PROVIDES Certified GlassMineral WoolAvailable CertifiedLaminated GlassMineral WoolAvailable Laminated Manufactured Meets or ExceedsASTM E-84 VaporRetarderBright CleanFinishedAppearance ExcellentAcousticProperties CustomSizedFabric &Insulation AirTightness Hot MeltTechnology Pinched Roof FormaldehydeFree Reflective No Visible Purlins No Visible Girts Visible Girts Visible Purlins Full Cavity Full Cavity Over Framing Full Cavity Over Framing Visible Purlins Full Cavity No Visible Purlins Full Cavity Exposed Purlins Visible Purlins Partial Cavity FullCoverage No Visible Girts Full Cavity Visible Bar Joist Full Cavity • Energy Saver fabric Optional • thermal block • Double layer insulation • Energy Saver banding OSHA-compliant leading edge fall protection for roofs Energy Saver FP protects the installation crew while the building is being insulated and roofed by providing OSHA-compliant leading edge fall protection when installed by a Silvercote certified contractor. Our certification is free and can be completed at silvercote.com To meet OSHA guidelines, an insulation support and fall protection system must restrain and support 400 pounds dropped from at least 42” above the highest walking or working surface. Energy Saver FP provides fall protection at the leading edge only and is just one component of a total fall protection plan for the job. Other means of fall protection are still required within six feet (6’) of any exterior roof edge, roof opening or common rafter where the system has not been completely installed in both bays. Tensile strength testing – We conduct daily testing on actual production samples of welded Energy Saver FP fabric to ensure your safety. Production samples must exhibit a seam strength of more than double the required failure strength to meet our standards and be considered acceptable for use in our roof Energy Saver FP system. TM Wall Girt EaveStrut RoofPurlin MetalAngle Energy Saver wall banding& fabric Energy Saver roof banding& fabric IT’S IN THE DETAILS There are many different connection needs based on manufacturer specifications for your building. A secure connection must be made around the entire perimeter and each penetration of the Energy Saver fabric to create a sealed envelope. Silvercote provides specifications for many standard connections. See the Energy Saver Install Instructions at Silvercote.com for specific details. Double Layer Wall System An unfaced glass mineral wool insulation layer is used to fill the girt cavity. A second layer of foil laminated glass mineral wool insulation layer creates the thermal barrier needed to meet todays energy codes.  Maximizes R-value with cavity filling system that provides excellent thermal properties with an additional external perforated faced layer of insulation  Reduced air-infiltration  Our Energy Saver fabric welding process produces seams that exceed the ASTMD-751 Standard of the fabric itself  Insul-Hold (hangers) retains the insulation in proper cavity location  Unique hot melt lamination technology virtually eliminates wrinkles PROVIDES • Double layer insulation with perforated foil facing • Energy Saver fabric • Insul-Hold • Energy Saver bandingCertified GlassMineral WoolAvailable CertifiedLaminated GlassMineral WoolAvailable Laminated Manufactured Meets or ExceedsASTM E-84 VaporRetarderBright CleanFinishedAppearance ExcellentAcousticProperties CustomSizedFabric &Insulation AirTightness Hot MeltTechnology Pinched Roof FormaldehydeFree Reflective No Visible Purlins No Visible Girts Visible Girts Visible Purlins Full Cavity Full Cavity Over Framing Full Cavity Over Framing Visible Purlins Full Cavity No Visible Purlins Full Cavity Exposed Purlins Visible Purlins Partial Cavity FullCoverage No Visible Girts Full Cavity Visible Bar Joist Full Cavity When installing the full cavity insulation horizontal installation provides: • Fewer seams reduces possibility of cold bridging • Reducing field cutting of insulation decreases labor costs • Custom widths available • Works with single or double layer Vertical installation provides: • Works with all girt spaces • Works with single or double layer Why we recommendhorizontal installation? Single Layer Wall System Unfaced glass mineral wool insulation is available in multiple thicknesses to fill the wall girt cavity.  Our Energy Saver fabric welding process produces seams that exceed the ASTMD-751 Standard of the fabric itself  Use of Insul-Hold retains the insulation in proper cavity location  Energy Saver Foam Tape provides a limited thermal bridge effect Certified GlassMineral WoolAvailable CertifiedLaminated GlassMineral WoolAvailable Laminated Manufactured Meets or ExceedsASTM E-84 VaporRetarderBright CleanFinishedAppearance ExcellentAcousticProperties CustomSizedFabric &Insulation AirTightness Hot MeltTechnology Pinched Roof FormaldehydeFree Reflective No Visible Purlins No Visible Girts Visible Girts Visible Purlins Full Cavity Full Cavity Over Framing Full Cavity Over Framing Visible Purlins Full Cavity No Visible Purlins Full Cavity Exposed Purlins Visible Purlins Partial Cavity FullCoverage No Visible Girts Full Cavity Visible Bar Joist Full Cavity PROVIDES • Unfaced Insulation Layer • Insul-Hold • Energy Saver fabric • Energy Saver Thermal Tape • Energy Saver banding Energy Saver Thermal Tape provides a thermal separation between the exterior metal panels and the building structural. This helps to prevent temperature transfer and condensation through the metal to the interior of the building. Supplied in 50’ long rolls it is adhesive backed for easy application. It is recommended that it be applied to all secondary steel or girts with direct contact to the exterior panels. Providing a thermal break R-Value* Nominal Thickness R-8 2 ⅝” R-10 3” R-11 3 ½” R-12 3 ½” R-13 4” R-19 6” R-20 6” R-21 6 ¾” R-25 8” R-28 8” R-30 9 ½” ECOSE glass mineral wool insulation Why we recommend a double layer system? When selecting a high R-value system it is imperative to use two layers. In roofs the top layer is perpendicular to and above the purlins minimizing the chance of sag which could potentially cause a void within the roof cavity and increase the potential for condensation. The bottom layer is used to fill the purlin cavity providing maximum energy efficiency. For the walls, as in roofs, the outer layer is perpendicular to the girts and minimizes the chance for condensation. The inner layer fills the wall girt space. Single layers systems, while acceptable, are not as efficient and require a thermal break. * Preinstalled values Silvercote Offers NAIMA Certified Glass Mineral Wool Insulation NAIMA 202.96® Certified Fiber Glass Metal Building Insulation is produced in a special manufacturing process to give it the structural integrity it needs to recover to full thickness after lamination, shipping and installation. This standard is a valuable specification tool for manufacturers, designers and users of metal building insulation systems. NIA 404 Certification is a post-lamination certification for flexible fiberglass insulation used in metal buildings. This certification assures builders and building owners that the fiberglass insulation specifically engineered for metal buildings meets 100% of the stated R-value after the lamination process. Certified GlassMineral WoolAvailable CertifiedLaminated GlassMineral WoolAvailable Laminated Manufactured Meets or ExceedsASTM E-84 VaporRetarderBright CleanFinishedAppearance ExcellentAcousticProperties CustomSizedFabric &Insulation AirTightness Hot MeltTechnology Pinched Roof FormaldehydeFree Reflective No Visible Purlins No Visible Girts Visible Girts Visible Purlins Full Cavity Full Cavity Over Framing Full Cavity Over Framing Visible Purlins Full Cavity No Visible Purlins Full Cavity Exposed Purlins Visible Purlins Partial Cavity FullCoverage No Visible Girts Full Cavity Visible Bar Joist Full Cavity Certified GlassMineral WoolAvailable CertifiedLaminated GlassMineral WoolAvailable Laminated Manufactured Meets or ExceedsASTM E-84 VaporRetarderBright CleanFinishedAppearance ExcellentAcousticProperties CustomSizedFabric &Insulation AirTightness Hot MeltTechnology Pinched Roof FormaldehydeFree Reflective No Visible Purlins No Visible Girts Visible Girts Visible Purlins Full Cavity Full Cavity Over Framing Full Cavity Over Framing Visible Purlins Full Cavity No Visible Purlins Full Cavity Exposed Purlins Visible Purlins Partial Cavity FullCoverage No Visible Girts Full Cavity Visible Bar Joist Full Cavity Certified GlassMineral WoolAvailable CertifiedLaminated GlassMineral WoolAvailable Laminated Manufactured Meets or ExceedsASTM E-84 VaporRetarderBright CleanFinishedAppearance ExcellentAcousticProperties CustomSizedFabric &Insulation AirTightness Hot MeltTechnology Pinched Roof FormaldehydeFree Reflective No VisiblePurlins No Visible Girts Visible Girts VisiblePurlins Full Cavity Full CavityOver FramingFull Cavity Over Framing VisiblePurlinsFull CavityNo VisiblePurlinsFull Cavity ExposedPurlinsVisiblePurlinsPartial CavityFullCoverage No Visible Girts Full Cavity VisibleBar JoistFull Cavity * It is important to completely fill the purlin/girt cavity. Contact your Silvercote Sales Representative for the best combination for your individual project. Double Layer Roof Double Layer Wall Single Layer Wall 29 43 CompliantFall Protection Certified GlassMineral WoolAvaliable Certified GlassMineral WoolAvaliableLaminated Manufactured Meets or exceedsASTM E-84 Vapor Retarder Bright CleanFinished apperance Excellent AcousticProperties Custom Sized Fabric Air Tightness No visiblePurlins Visible Purlins Full Cavity Pinched MBI Roll Roof ExposedPurlins Full CavitySingle layer FormaldehydeFree Reflective * Our glass mineral wool insulation is available with ECOSE Technology binder. ECOSE Technology insulation products deliver the same exceptional quality, handling and durability you have come to expect and is Formaldehyde Free! It is certified to the toughest indoor air quality certification in the industry - GREENGUARD Gold - and is certified to meet CHPS Low-Emitting Materials criteria section 01350. CompliantFall Protection Certified GlassMineral WoolAvaliable Certified GlassMineral WoolAvaliableLaminated Manufactured Meets or exceedsASTM E-84 Vapor Retarder Bright CleanFinished apperance Excellent AcousticProperties Custom Sized Fabric Air Tightness No visiblePurlins Visible Purlins Full Cavity Pinched MBI Roll Roof ExposedPurlins Full CavitySingle layer FormaldehydeFree Reflective 19 40**13 30 CompliantFall Protection Certified GlassMineral WoolAvaliable Certified GlassMineral WoolAvaliableLaminated Manufactured Meets or exceedsASTM E-84 Vapor Retarder Bright CleanFinished apperance Excellent AcousticProperties Custom Sized Fabric Air Tightness No visiblePurlins Visible Purlins Full Cavity Pinched MBI Roll Roof ExposedPurlins Full CavitySingle layer FormaldehydeFree Reflective Outside layer wall maximum COMcheck™ Solutions Your Silvercote sales representative can provide help to meet your energy code compliance. “The COMcheck product group makes it easy for architects, builders, designers, and contractors to determine whether new commercial or high-rise residential buildings, additions, and alterations meet the requirements of the IECC and ASHRAE Standard 90.1, as well as several state-specific codes. COMcheck also simplifies compliance for building officials, plan checkers, and inspectors by allowing them to quickly determine if a building project meets the code.” U.S. Department of Energy Hot Box Testing ASTM C1363-11 – Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by means of a Hot Box Apparatus. To accomplish this test, a box is outfitted with sensors that accurately measure the rate at which heat flows through a building assembly (roof or wall). The corresponding data is presented in the form of a “U-factor.” DOUBLE LAYER ROOF* R-25 + R-8 ....................................0.035 8” Z purlin 1” EPS spacer block standing seam roof R-30 + R-8 ..................................0.0299 10” Z purlin 1” EPS spacer block standing seam roof DOUBLE LAYER WALL** Rated insulation U-factor for base R-value wall assembly R-25 + R-10 ........................................0.047 R-25 + R-16 ........................................0.042 R-25 + R-10A ......................................0.039 R-30 + R-16 ........................................0.039 SINGLE LAYER WALL** Rated insulation U-factor for base R-value wall assembly R-25 ...................................................0.059 R-30 ...................................................0.052 U-factors * NAHB research center in Richmond, VA. ** ASHRAE. A Minimum R-3 thermal spacer block is required. LEED Eligible Glass Mineral Wool Insulation • Optimized energy performance • Reduced demand for virgin materials • 80% recycled content • Use of regional materials • Incorporating rapidly renewable materials • Improved air quality • A comfortable thermal environment • High performance acoustic properties Save more than energy Did you know that insulation saves commercial building owners more than $9.6 billion in energy costs annually? Insulation also reduces annual energy use in U.S. buildings by 12 quadrillion BTUs, roughly 15 percent of total U.S. annual energy usage. It also diminishes power plant emissions, cutting carbon dioxide by 780 million tons annually. (The figures include both commercial and residential buildings and are taken from the study “Green and Competitive: The Energy, Environmental and Economic Benefits of Fiber Glass and Mineral Wool Insulation Products.”) According to the U.S. Department of Energy, one third of the energy used in commercial buildings is devoted to heating and cooling. That’s why it makes good business sense to maximize the glass mineral wool insulation in your building(s) to achieve greater energy savings and reduce heating and cooling loads. Of course this is just the tip of the iceberg. There are layers of benefits to adding glass mineral wool insulation in commercial buildings - from increased energy savings, temperature and condensation control to noise reduction and environmental sustainability. Architects We know how important aesthetics, acoustical properties and thermal performance are for your clients. Energy Saver systems provide a clean, bright finished ceiling for maximum lighting efficiency and meets or exceeds the IECC 2015 energy codes with unlimited R-value capability. Metal Building Manufacturers and Owners You can have confidence in Energy Saver’s longevity and durability. Energy Saver systems are engineered to last – just like your metal buildings. Energy Saver’s full cavity envelope creates a continuous thermal shield to make sure you get the maximum return on your investment. Contractors and Installers We know how important safety is on the jobsite. Energy Saver FP meets OSHA-compliant leading edge fall protection standards. We make it easy for you and your crew to install by using our simplified instructions. Free online, Energy Saver Fall Protection system training available. Energy Saver Envelope Components and Accessories Insulation – Our metal building insulation is available with formaldehyde free ECOSE Technology binder, which is GREENGUARD Gold certified. Our glass mineral wool insulation features an FHC 25/50 flame spread and smoke developed rating per ASTM E84 Standards. This superior glass mineral wool insulation can be cut to width for your building specifications. Fabric – Energy Saver fabric is a woven reinforced high- density polyethylene yarn, then coated on both sides with a continuous white or colored polyethylene coating. Our fabric provides a bright and durable interior finish. It is folded to allow for rapid pullout onto the banding grid and features an FHC 25/50 rating per ASTM E84 Standards. Color ...........................................................White/grey Weight ........................................................4.4 oz/yd2 (149g/m2) +/- 5 % Thickness ..................................................Nominal 9 mil (0.22 mm) ASTM D1777 Grab Tensile ..............................................Warp 130 lb 577 N / Weft 155 lb 510 N, ASTM D-5034 Strip Tensile (N/5cm) ................................Warp 95 lb/in (843)/Weft 90 lb/in (799), ASTM D-5035 Tongue Tear ...............................................Warp 50 lb 222 N / Weft 45 lb 200 N, ASTM D-2261 Mullen Burst ..............................................235 psi 1619 kPa, ASTM D-3786 Moisture Vapor Transmission ..................0.02 perms, ASTM E-96 Surface Burning Characteristics .............Flame Spread: 0, Smoke Developed: 30 ....................................................................(white side exposed) UL723 (ASTM E84) UV Weathering ..........................................UV stabilizer added for Extra UV resistance Note: These are manufacturer supplied property values and are intended as guides only. The figures listed do not represent specification minimums or limits. Energy Saver Adhesive – Our specially designed high shear and high tack adhesive bonds the fabric to the steel framing. Energy Saver Patch Tape – Designed to mimic the appearance of the Energy Saver fabric our patch tape is used to seal cuts around protrusions. Energy Saver Foam tape – Applied to the outer secondary steel to help reduce heat transfer. Energy Saver Banding – The banding provides abundant support for the Energy Saver components while contributing properly designed strength characteristics necessary to pass the rigorous 400 pound drop test (as per OSHA 1926.502) for Energy Saver FP. Energy Saver Banding Clips – United States Patent 8,015,769. The banding clips provide a clean, finished appearance, while minimizing the number of fasteners required. Insul-Hold – Used to support our glass mineral wool insulation in the wall girt cavity. Unlike other products, they can be cut to length to fit the metal frame. OSHA-compliant leading edge fall protection – The Energy Saver FP system provides OSHA-compliant leading edge fall protection when installed according to manufacturer’s instructions by a Silvercote certified installing contractor. Energy Saver FP is fall protection at the leading edge only and is only one component of a total fall protection plan for the job. Other means of fall protection are still required within six feet (6’) of any exterior roof edge, roof opening or common rafter where the system has not been completely installed in both bays. Contact your Silvercote sales representative or see the Energy Saver FP Contractor Agreement and installation instructions for more details. Certification is available online at silvercote.com. Note: As per Energy Saver certification OSHA-compliant leading edge fall protection with this system, install only Energy Saver components and accessories that are sent with your order. “We really enjoy installing the Energy Saver system because purlin braces are no longer a problem. Owners like it because of the clean bright building interior. Our installation crews like installing it due to the leading edge fall protection.” Dan Forget | Sieve Contractors Inc. (Energy Saver)“... it’s a product that is easily installed, gives a good double layer insulating value, and looks great when complete.” Dwayne Jess | Prairieland Construction NOTES © 2019 Silvercote, LLCSIL083-010 8/19 Please contact your Silvercote Sales Representativefor more information at (844) 232-3701 or info@silvercote.com