Quality Assurance Report
Single Direction Multi Point Blower Door Test
PASS Your Result: 2.64 ACH50 (2155.35 CFM50 * 60 / 48954 ft3)
Target < 3 ACH50
Test Information
Test Name
Test Date
Export id
Company Name
Technician Name
Technician Email
Building Information
Address
City
State
Zip/postal Code
Country
Year Constructed
Elevation
Address Verified?
Building Latitude, Longitude
GPS validation
Estimated Distance From Address
Test Equipment
Fan Model
Fan Serial Number
Pressure Gauge Model
Gauge Serial Number
Environmental Conditions
Pre -test Indoor Temperature
Pre -test Outdoor Temperature
Wind Speed
Average Barometric Pressure
Test Dimensions
Conditioned Floor Area
Volume
241 Silver Mountain Final
2025-12-23 10:40 AM (MST)
OFQONUZ7
Dexter Diagnostics
Amanda Poindexter
dexterdiagnostics@gmail.com
241 Silver Mountain Drive
Glenwood Springs
co
81601
United States
Not available
6006 ft
No
Your location has not been validated.
Tester location not verified
Not available
Retrotec 5000
5FN105365
Retrotec DM32X
502769
70 OF
36 OF
3 MPH
103.2 kPa
3219 ft2
48954 ft3
Retrotec rCloud
I
Test Results Summary
Test Type
Flow Reference Pressure
Time Averaging
Corrected Flow
Air Changes Per Hour
Percent Uncertainty
Correlation, r
Intercept
Slope, n
Test Results
Test Data Set 1
Flow Direction
Gauge Location
Baseline, initial (Pa)
-0.62 -0.64 -0.66 -0.67
Baseline Duration
Average baseline
Single Direction Multi Point Blower Door Test
50 Pa
10 seconds
2155.35 CFM @ 50 Pa
2.642
1.4%
0.999
156.994
0.670
Depressurize
Inside
-0.69 -0.72 -0.75 -0.77 -0.8 -0.81
10 seconds
-0.71 Pa
Measured Pressure (Pa) -14.54 -22.5 -30.07 -37.51
Fan Pressure [5000 - 134] (Pa) 234.07
Fan Pressure [5000 - A] (Pa) 21.36 31.03 41.32
Flow (CFM) 978.67 1334.54 1609.62 1858.7
Measured Pressure (Pa) -44.49 -52.57 -60.44
Fan Pressure [5000 - B4] (Pa)
Fan Pressure [5000 - A] (Pa) 50.79 62.73 75
Flow (CFM) 2061.59 2291.92 2507.08
Baseline, final (Pa)
-0.51 -0.5 -0.49 -0.49 -0.48 -0.46 -0.46 -0.46 -0.47 -0.47
Baseline Duration 10 seconds
Average baseline -0.48 Pa
2
retro�
Test Notes
No notes entered.
Retrotec rCloud
Flow Equation Parameters - Retrotec Calibrated Flow Parameters
Certificate Number: 202408291152-5FN105365
Fan Last Calibrated: 2024-09-11
Fan Model Retrotec 5000
Fan Serial Number 5FN105365
Fan Last Calibrated: 2024-09-11
Units Used For Flow Parameters in Equation CFM
Fan pressure (FP) is the measured fan pressure when using a self -referenced fan or when the room pressure is
negative. If using a fan which is not self -referenced, and the room pressure is positive, fan pressure is calculated
by subtracting the measured room pressure from the absolute value of the fan pressure.
If PrA is greater than 0 or fan is self -referencing: FP = jPrBj - PrA
If PrA is less than 0 or fan is self -referencing: FP = PrB
Flow calculations are not valid if fan pressure is less than either MF or (K2 x IRPI)
FP = tan pressure, RP = room pressure
Range N
K K1
K2
K3
K4
MF
Open 0.4990
555.2054 0.0000
0.3000
0.0000
1
10
A 0.5030
290.8751 0.0000
0.4000
0.0000
1
20
B8 0.5270
121.5413 0.0000
0.7000
0.0000
1
35
flow = (FP - RP x K1)°
X (K + K3 x FP) X K4
Range
A
B
C
D
F
G
K2
MF
B4
0.0000176573
-0.01530302
6.2742
138.42
0.59
50
0.8000
40
B2
0.0000025309
-0.00466154
2.7545
25.71
0.92
50
1.0000
50
131
0.0000027369
-0.00313712
1.4891
10.71
0.45
50
1.0000
60
B74
0.0000007960
-0.00095010
0.5900
18.00
0.15
25
0.8000
35
B47
0.0000002690
-0.00035905
0.2435
12.05
0.09
25
1.0000
50
B29
0.0000001110
-0.00014900
0.0920
4.40
-0.02
25
0.6000
50
flow = (A
x FP3) + (B x FP2)
+ (C x FP) + D
+((G - RP) x F)
I