HomeMy WebLinkAboutBlower Door TestA%, U" Aiji C Retrotec rCloud Quality Assurance Report Single Direction Multi Point Blower Door Test PASS Your Result: 2.64 ACH50 (2155.35 CFM50 * 60 / 48954 ft3) Target < 3 ACH50 Test Information Test Name Test Date Export id Company Name Technician Name Technician Email Building Information Address City State Zip/postal Code Country Year Constructed Elevation Address Verified? Building Latitude, Longitude GPS validation Estimated Distance From Address Test Equipment Fan Model Fan Serial Number Pressure Gauge Model Gauge Serial Number Environmental Conditions Pre -test Indoor Temperature Pre -test Outdoor Temperature Wind Speed Average Barometric Pressure Test Dimensions Conditioned Floor Area Volume 241 Silver Mountain Final 2025-12-23 10:40 AM (MST) OFQONUZ7 Dexter Diagnostics Amanda Poindexter dexterdiagnostics@gmail.com 241 Silver Mountain Drive Glenwood Springs co 81601 United States Not available 6006 ft No Your location has not been validated. Tester location not verified Not available Retrotec 5000 5FN105365 Retrotec DM32X 502769 70 OF 36 OF 3 MPH 103.2 kPa 3219 ft2 48954 ft3 Retrotec rCloud I Test Results Summary Test Type Flow Reference Pressure Time Averaging Corrected Flow Air Changes Per Hour Percent Uncertainty Correlation, r Intercept Slope, n Test Results Test Data Set 1 Flow Direction Gauge Location Baseline, initial (Pa) -0.62 -0.64 -0.66 -0.67 Baseline Duration Average baseline Single Direction Multi Point Blower Door Test 50 Pa 10 seconds 2155.35 CFM @ 50 Pa 2.642 1.4% 0.999 156.994 0.670 Depressurize Inside -0.69 -0.72 -0.75 -0.77 -0.8 -0.81 10 seconds -0.71 Pa Measured Pressure (Pa) -14.54 -22.5 -30.07 -37.51 Fan Pressure [5000 - 134] (Pa) 234.07 Fan Pressure [5000 - A] (Pa) 21.36 31.03 41.32 Flow (CFM) 978.67 1334.54 1609.62 1858.7 Measured Pressure (Pa) -44.49 -52.57 -60.44 Fan Pressure [5000 - B4] (Pa) Fan Pressure [5000 - A] (Pa) 50.79 62.73 75 Flow (CFM) 2061.59 2291.92 2507.08 Baseline, final (Pa) -0.51 -0.5 -0.49 -0.49 -0.48 -0.46 -0.46 -0.46 -0.47 -0.47 Baseline Duration 10 seconds Average baseline -0.48 Pa 2 retro� Test Notes No notes entered. Retrotec rCloud Flow Equation Parameters - Retrotec Calibrated Flow Parameters Certificate Number: 202408291152-5FN105365 Fan Last Calibrated: 2024-09-11 Fan Model Retrotec 5000 Fan Serial Number 5FN105365 Fan Last Calibrated: 2024-09-11 Units Used For Flow Parameters in Equation CFM Fan pressure (FP) is the measured fan pressure when using a self -referenced fan or when the room pressure is negative. If using a fan which is not self -referenced, and the room pressure is positive, fan pressure is calculated by subtracting the measured room pressure from the absolute value of the fan pressure. If PrA is greater than 0 or fan is self -referencing: FP = jPrBj - PrA If PrA is less than 0 or fan is self -referencing: FP = PrB Flow calculations are not valid if fan pressure is less than either MF or (K2 x IRPI) FP = tan pressure, RP = room pressure Range N K K1 K2 K3 K4 MF Open 0.4990 555.2054 0.0000 0.3000 0.0000 1 10 A 0.5030 290.8751 0.0000 0.4000 0.0000 1 20 B8 0.5270 121.5413 0.0000 0.7000 0.0000 1 35 flow = (FP - RP x K1)° X (K + K3 x FP) X K4 Range A B C D F G K2 MF B4 0.0000176573 -0.01530302 6.2742 138.42 0.59 50 0.8000 40 B2 0.0000025309 -0.00466154 2.7545 25.71 0.92 50 1.0000 50 131 0.0000027369 -0.00313712 1.4891 10.71 0.45 50 1.0000 60 B74 0.0000007960 -0.00095010 0.5900 18.00 0.15 25 0.8000 35 B47 0.0000002690 -0.00035905 0.2435 12.05 0.09 25 1.0000 50 B29 0.0000001110 -0.00014900 0.0920 4.40 -0.02 25 0.6000 50 flow = (A x FP3) + (B x FP2) + (C x FP) + D +((G - RP) x F) I