Shop inspection for 12 Weeping Willow Dr. 11-20-2025
- - --
QUANTITY DESCRIPTION UNIT PRICE TOTAL
4 hrs Inspection time $90.00/hr $360.00
I
1 hr Report time
$90.00/hr1,—$90.00
$0.70/mi
TOTAL DUE ON RECEIPT OF INVOICE
$70.00
$520.00
Make all checks payable to Monument Steel Inspection, LLC. Or send electronic payment through Venmo - @welderbrik,
inBuild, or BILL.
If you have any questions concerning this invoice, contact Daniel Bricker, 318-469-2279.
Late fees totaling 5% will be accrued after 30 days of non-payment. Additional fees may result after 60 days of non-payment.
THAN( YOU FOR YOUR BUSINESS!
MUNUMENT
STEEL
INSPE ON, LLC
Mr. Bobby Almazan 11-20-2025
Ram Development, Inc.
Re: 12 Weeping Willow
Dear Mr. Almazan,
As requested, structural steel special inspection was conducted per the
IBC 2021 Edition - Chapter 17: Structural Tests and Special Inspection and the
Town of Carbondale requirements. I arrived at the fabricator's facility at 9:00
AM. I met with Mr. Jorge Gomez with Alpine Steel to review project requirements
and material ready for inspection.
Continuous visual welding inspection was conducted on the Complete
Joint Penetration (CJP) groove welds for one bent beam (part # B31) for the
above project. Mr. Jorge Gomez was the certified welder of record. All fit -up and
preheat were checked prior to any welding. The following parameters were
observed to be compliant with the requirements of the governing WPS:
• Base metal composition
• Filler metal composition
• Joint configuration and base metal preparation
• Shielding gas and flow rate
• Joint fit -up
• Root opening
• Preheat temperature
• Interpass temperature
• Welding current characteristics
• Amperage employed
Monument Steel Inspection, LLC 318.469.2279
PO Box 23388
Glade Park, CO 81523
monumentsteelinspectionllc22@gmail.com
Voltage employed
Upon completion, I observed all CJP groove welds to be in compliance with
project specifications and the inspection requirements as stated in Clause 8
of the AWS D1.1 Structural Welding Code — Steei:2020 Edition.
Respectfully submitted,
Dan Bricker, CWI
AWS CWI #09052051
Monument Steel Inspection
® Dani I. k�r
qNJ$ C 0�
Q /1 i2027
Monument Steel Inspection, LLC