HomeMy WebLinkAboutInsulation Certificate novainsul@gmail.com Date: 10/20/2025 Plans dated: Proposal to: J Caliber Construction Project: Contact: Jose Gonzalez Address: 670 Cattle Dr. Silt CO Email: jose@jcaliberconstruction.com Sales Contact: Martin Cornejo 970-361-7949 Phone: 970-314-0489 Email Martin cornejo05@icloud.com INSULATION CERTIFICATE: Inaccessible Attics R-49 Unfaced Batts (24"oc) Exterior Walls (Sheeted) R-28 Hybrid R-15 (2”) polyurethane spray foam and R-13 fg batts Sound Ceiling R-19 Unfaced (24''oc) Basement Ceiling 3" Rockwool Exterior Basement Walls (Furred) R-13 Unfaced (15"oc) Interior Walls R-11 Unfaced (15"oc) House To Garage Common Wall R-21 Unfaced (15"oc) Garage Ceiling Under R-30 Unfaced (24"oc) Garage Walls R-21 Unfaced (15"oc) Crawl Walls R-19 Unfaced Drape Crawl Floor Visqueen 6mil Attic Knee Walls R-21 Unfaced (15"oc) Seal Package Foam Doors, Windows & Penetrations Seal Package Foam Ceiling Penetrations Ventilation Package Baffles At Every Bay Exterior Rim Joist Ends R-22.5 (3.5”) polyurethane spray foam (15"oc) Sales Representative: Martin Cornejo__________ Date:______10 / 20 / 2025____________ 800-828-1394 | swdurethane.com PUBLISH DATE: 09/2024 QUIK-SHIELD YETI All Seasons HFO Spray Foam QUIK-SHIELD® YETI is a closed-cell spray foam insulation, using Honeywell’s Solstice® liquid blowing agent which has a GWP of 1, 99.9% lower than traditional blowing agents meeting GWP initiatives. It is a high-performance insulation and air barrier, ideal for residential and commercial construction. QUIK-SHIELD® YETI increases jobsite efficiency, decreases labor and overhead costs, and delivers a lower install cost. TYPICAL PHYSICAL PROPERTIES Properties achieved in a lab environment at 77°F. Field conditions may cause variation in properties. PROCEDURE VALUES Air Permeance at 1” (L/s.m²) E-2178 <0.02 Closed-Cell, content (%)E-2178 >90 Compressive Strength (psi)D-1621 >15 Core Density (nominal, lb/ft3)D-1622 2.0 Dimensional Stability (%)D-2126 <15 Tensile Strength lb/in2 (psi)D-1623 >15 Water Vapor Permeability (perm-inch)E-96 1.72 Fungi Resistance C-1338 No Growth THERMAL RESISTANCE (R-Value) (°F.ft2.h/Btu) R-Value at 1”7.5 R-Value/inch at ≥ 3.5”7.5 THERMAL/IGNITION BARRIERS For information regarding approved thermal and ignition barriers please refer to Intertek’s Code Compliance Research Report # 0478 (CCRR-0478) LIQUID PROPERTIES at 77°F (25°C) A-SIDE (ISO)B-SIDE (RESIN) Specific Gravity 1.23 1.21 Viscosity (cPs)250±50 550±100 RECOMMENDED STORAGE AND SHELF LIFE • Storage temperatures 50-80°F (10-27°C). See back for preconditioning of material. • 6 month shelf life from date of manufacture (unopened containers) • Keep container tightly sealed • Store out of direct sunlight, in a cool dry place, avoid freezing PRODUCT INFORMATION LEED QUIK-SHIELD® YETI has a minimum of 10.5% total renewable/recycle content, 5.5% pre-consumer recycled, 4.2% post-consumer recycled, 2.0% rapidly renewable, and IEQ Credit- Low Emitting. Product Packaging 275 Gallon Tote and 55 Gallon Drum APPROVALS / COMPLIANCE QUIK-SHIELD® YETI has been tested by a third party laboratory (Intertek Testings Services NA, Inc.) CCRR-0478 GREENGUARD Gold Certified Honeywell’s Solstice® liquid blowing agent GREENGUARD PRODUCT CERTIFIED FORLOW CHEMICAL EMISSIONSUL.COM GGUL 2818 GOLD PUBLISH DATE: 09/2024 The information herein is believed to be reliable; however, unknown risks may be present. SWD Urethane makes no warranty, expressed or implied, concerning this product’s merchantability or fitness for any particular use. The product will meet the written liquid component specifications as indicated on the technical data sheet published at the time of the purchase. The entirety of SWD Urethane’s responsibility is limited only to the cost of the SWD material. The foregoing constitutes SWD Urethane’s sole obligation with respect to damages, whether direct, incidental or consequential, resulting from the use or performance of the product. Safety is the responsibility of the owner, the owner’s appointed representative, the contractor, and/or inspector. Become familiar with local, state, and federal regulations regarding chemical health, safety, and handling. For more information consult the product SDS, contact the SPFA (www.sprayfoam.org) or the ACC (www.spraypolyurethane.org). SWD Urethane | 800-828-1394 | 540 South Drew St. | Mesa, AZ 85210 | swdurethane.com PREPARATION OF SUBSTRATES Providing the proper substrate is the responsibility of the owner, the owner’s appointed representative, the contractor, and/or inspector. The following are manufacturer’s recommendations. However, other preparation techniques may be required given unique/specialized application circumstances. Contact SWD Technical Support at 888-380-2022 for additional questions. It is recommended to remove dust, dirt, oil, paint, and alternative polymers from all surfaces prior to applying SWD products. See SWD specifications or SPFA guidelines for further details on substrate prep. Wood • Ensure wood is relatively dry and protect surfaces from contamination. For moisture content exceeding 19%, contact SWD Technical Support. • Water or oil present may cause poor adhesion or excessive foaming. • Fill large voids with appropriate backer rods or appropriate fillers. • If additional information is required, contact SWD Technical Support. Steel & Other Metals • It is the responsibility of the contractor/end user to determine proper adhesion and suitability through field testing. Blasting and/or priming is not always required. If additional information is required, contact SWD Technical Support. Concrete • If applying foam to concrete, the concrete surface should be structurally sound, clean, and curing for 28 days. • Fill large voids with appropriate backer rods or appropriate fillers. • Blasting and/or priming is not always required. It is the responsibility of the contractor/end user to determine proper adhesion and suitability. If additional information is required, contact SWD Technical Support. Previously Applied Foam or Other Polymers • As practical, remove previously applied foam and other polymer products. Application of product over existing materials should be performed only after adhesion/compatibility is verified by the contractor and accepted by the building owner or owner’s appointed representative. Wiring and Plumbing • QUIK-SHIELD® YETI is fully compatible with CPVC piping systems (Paschal Engineering Study for the SPFA). • QUIK-SHIELD® YETI is compatible with typical electrical wiring coverings. (NEMA Bulletin 95) PROCESSING Preconditioning 1. If the drum temperature is 80°F (26.6°C) or higher, use caution when opening the drum! The contents will be under pressure. 2. It is recommended to precondition material to 60-80°F (16-27°C) prior to application. Material may thicken at lower temperatures which can cavitate pumps. Mixing 3. Mixing of B-Side (resin) is not required. 4. Mixing of A-Side (iso) is not required. Pressure Settings 5. Product should be sprayed with a high pressure plural-component proportioner capable of a minimum of 1100 psi dynamic pressure. 6. Static pressure is typically set between 1200-1600psi. Temperature Settings 7. Primary heaters and hose heaters are typically set between 105-145°F (41-63°C). Higher temperatures are utilized in winter months, lower temperatures are utilized in summer months. Proper application temperature setting is the responsibility of the end user. Equipment temperature varies and can be dependent on equipment, hose length, elevation, ambient temperature, substrate temperature, humidity, and other factors. If additional information is required, refer to QUIK-SHIELD YETI Processing Packet found on swdurethane.com and the SWD mobile app, or contact SWD Technical Support at 888-380-2022. APPLICATION 1. Do not spray foam when substrate surface temperatures are less than 5°F above the dew point. 2. Clean surfaces according to “Preparation of Substrates” section. 3. If priming, follow manufacturer recommendations. Ensure primer is adequately cured prior to application. 4. Substrate temperatures should be between 20-120°F (-6-49°C) Flashing is recommended at lower temperatures. Contact SWD Technical Support for more details. 5. Flush an adequate amount of material through the lines/gun prior to spraying desired surface when changing between systems. Flush amount will be dependent on prior system used. If additional information is required, contact SWD Technical Support for more details. 6. Do not recirculate. 7. QUIK-SHIELD® YETI shall not exceed 4” per lift, with a minimum 20-30 minute wait time between lifts. 8. Before application, test material to ensure that material sprays, cures, and hardens properly. 9. Inspect applied material intermittently to ensure no problems exist. If problems are detected, discontinue application and inspect all substrates, equipment, gun, and liquid material for problem source(s). CLEANING AND MAINTENANCE 1. Spray equipment must be maintained in proper operating condition. Failure to adequately maintain spray equipment may result in poor product performance. Refer to your equipment manufacturer’s maintenance procedures for more details. 2. Contact SWD for long-term equipment storage recommendations. Technical Data Sheet QUIK-SHIELD YETI Code Compliance Research Report CCRR-0478 Issue Date: 12-13-2022 Revision Date: 10-30-2024 Renewal Date: 10-31-2025 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 intertek.com/building PCA-101 Version: 21 December 2017 SFT-CCRR-OP-40b DIVISION: 07 00 00 – THERMAL AND MOISTURE PROTECTION Section: 07 21 00 – Thermal Insulation Section: 07 21 19 – Foamed-In-Place Insulation Section: 07 25 00 – Weather Barriers REPORT HOLDER: SWD Urethane 540 South Drew Street Mesa, Arizona 85210 (480) 969-8413 www.swdurethane.com technical@swdurethane.com REPORT SUBJECT: SWD Quik-Shield® | YETI Spray-applied Polyurethane Foam Insulation 1.0 SCOPE OF EVALUATION 1.1 This Research Report addresses compliance with the following Codes: • 2024, 2021 and 2018 International Building Code® (IBC) • 2024, 2021 and 2018 International Residential Code® (IRC) • 2024, 2021 and 2018 International Energy Conservation Code® (IECC) NOTE: This report references the most recent Code editions noted. Sections for earlier editions may differ. 1.2 SWD Quik-Shield® | YETI insulation has been evaluated for the following properties (see Table 1): • Surface burning characteristics • Physical properties • Air permeability • Vapor permeance 1.3 SWD Quik-Shield® | YETI insulation has been evaluated for the following uses (see Table 1): • Use as nonstructural thermal insulation on or in interior and exterior walls, floors, the underside of roof decks • Alternatives to Code-prescribed ignition barriers • Alternatives to Code-prescribed thermal barriers • Alternative to water-resistive barriers • Use as air-impermeable insulation • Use as a Class II vapor retarder • Use in exterior walls of Types I, II, III, and IV construction • Use in Type V construction • Use as duct insulation 2.0 STATEMENT OF COMPLIANCE SWD Quik-Shield® | YETI insulation complies with the Codes listed in Section 1.1, for the properties stated in Section 1.2 and uses stated in Section 1.3, when installed as described in this report, including the Conditions of Use stated in Section 6. 3.0 DESCRIPTION 3.1 SWD Quik-Shield® | YETI: SWD Quik-Shield® | YETI is a two-component foam plastic insulation. The insulation is produced in the field by combining Component A and resin Component B, resulting in insulation with a nominal density of 2 pounds per cubic feet. The insulation components have a shelf life of six months when stored at temperatures between 50°F and 80°F before installation. 3.2 Intumescent Coatings: 3.2.1 DC315 Intumescent Coating: DC315 intumescent coating, manufactured by IFTI, Paint to Protect, is a water- based coating supplied in 5-gallon pails and 55-gallon drums. The coating material has a shelf life of 24 months when stored in factory-sealed containers at temperatures between 41°F and 95°F. DC315 complies with AC456 as recognized in ICC-ES ESR-3702. 3.2.2 Flame Control 60-60A Intumescent Coating: Flame Control 60-60A, manufactured by Flame Control Coatings, is a water-based coating supplied in 5-gallon pails and 55- gallon drums. The coating material has a shelf life of 12 months when stored in factory-sealed containers at Code Compliance Research Report CCRR-0478 Page 2 of 8 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 intertek.com/building PCA-101 Version: 21 December 2017 SFT-CCRR-OP-40b temperatures between 50°F and 80°F. Flame Control 60- 60A complies with AC456 as recognized IAPMO UES ER- 0596. 3.2.3 NO-BURN® Plus ThB Intumescent Coating: NO- BURN® Plus ThB, manufactured by NO-BURN®, Inc., is a white, water-based latex liquid. Supplied in 5-gallon pails and 55-gallon drums. The coating material has a shelf life of 3 years when stored in factory-sealed containers at temperatures between 40°F and 90°F. NO-BURN® Plus ThB complies with AC 456 as recognized in IAPMO UES ER-0305. 3.2.4 Fireshell F10E Intumescent Coating: Fireshell F10E intumescent coating, manufactured by ICP Construction, is a water-based intumescent coating supplied in 5-gallon pails and 55-gallon drums. The coating has a shelf life of 1 year when stored unopened at temperatures between 45°F and 95°F. Fireshell F10E complies with AC456 as recognized in ICC-ES ESR-3997. 4.0 PERFORMANCE CHARACTERISTICS 4.1 Surface-burning Characteristics: SWD Quik-Shield® | YETI, at a maximum thickness of 4 inches and a nominal density of 2 pounds per cubic feet, has a flame spread index of 25 or less and a smoke-developed index of 450 or less when tested in accordance with ASTM E84. SWD Quik- Shield® | YETI can be installed at greater thicknesses as described in Sections 5.3 and 5.4.2. When the insulation is separated from the interior living space of the building with minimum 1/2-inch-thick gypsum board, the maximum insulation thickness is not limited. Under the IRC, a thermal barrier of minimum 23/32-inch-thick wood structural panel is also permitted, and the maximum insulation thickness is not limited. 4.2 Thermal Resistance (R-value): SWD Quik-Shield® | YETI has a thermal resistance (R-value) of 7.5 °F·ft²·h/Btu per inch of thickness, at a mean temperature of 75°F, as shown in Table 3. 4.3 Air Permeability: SWD Quik-Shield® | YETI, at a minimum thickness of 1 inch, is considered air- impermeable insulation in accordance with IBC Section 202 and IRC Section R202, based on testing in accordance with ASTM E2178. 4.4 Vapor Permeance: SWD Quik-Shield® | YETI, at a minimum thickness of 1.82 inches, is a Class II vapor retarder in accordance with IBC Section 202, IRC Section R202, based on testing in accordance with ASTM E96 (desiccant method). The insulation may be used where a Class II vapor retarder is required under IBC Section 1404.3 or IRC Section R702.7 when installed at a minimum of 1.82 inches. 5.0 INSTALLATION 5.1 General: SWD Quik-Shield® | YETI insulation must be installed in accordance with the manufacturer’s published installation instructions, the applicable Code, and this Research Report. The installation requirements in Sections 5.1 through 5.4 apply to all Types of construction. Section 5.6 applies to use of SWD Quik-Shield® | YETI in Types I, II, III, and IV construction. A copy of the manufacturer’s instructions must be available on the jobsite during installation. The insulation must be stored at temperatures between 50°F and 80°F and must not be used in areas that have a maximum service temperature greater than 250°F. The foam plastic insulation must not be used in electrical outlet or junction boxes, or in contact with rain or water. The substrate must be free of moisture, frost or ice, loose scales, rust, oil, and grease. The insulation must be protected from the weather during and after application, unless approved specifically by SWD Urethane. The manufacturer’s published installation instructions must be available on the jobsite at all times during installation. 5.2 Application: The insulation is spray-applied on the jobsite using spray equipment specified in SWD Urethane’s published installation instructions. Quik-Shield® | YETI can be installed in one or more passes in thicknesses up to 4 inches per pass to achieve the maximum thicknesses specified in this report. Each pass must be allowed to fully expand prior to application of additional passes. Where used as an air-impermeable insulation, such as in unvented attic spaces in accordance with IBC Section 1202.3 or IRC Section R806.5, the insulation must be installed at a minimum thickness of 1 inch. Code Compliance Research Report CCRR-0478 Page 3 of 8 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 intertek.com/building PCA-101 Version: 21 December 2017 SFT-CCRR-OP-40b 5.3 Thermal Barrier: 5.3.1 Application with a Prescriptive Thermal Barrier: The insulation must be separated from the interior of the building by an approved thermal barrier of 1/2-inch-thick gypsum wallboard or an equivalent thermal barrier complying with IBC Section 2603.4 or IRC Section R303.4, as applicable, except where installation is in an attic or crawl space as described in Section 5.4. When the insulation is separated from the interior living space of the building with minimum ½-inch-thick gypsum board, the maximum insulation thickness is not limited. Under the IRC, a thermal barrier of minimum 23/32-inch-thick wood structural panel is also permitted, and the maximum insulation thickness is not limited. 5.3.2 Application without a Prescriptive Thermal Barrier: 5.3.2.1 SWD Quik-Shield® | YETI may be installed without the 15-minute thermal barrier prescribed in IBC Section 2603.4 and IRC Section R303.4, when installed conforming to one of the assemblies described in Table 2. The intumescent coatings indicated in Table 2 must be applied over the insulation in accordance with the coating manufacturer’s instructions and this report. Surfaces to be coated must be dry, clean, and free of dirt, loose debris, and other substances that could interfere with adhesion of the coating. The coating is applied with low-pressure airless spray equipment. 5.4 Attics and Crawl Spaces: 5.4.1 Application with a Prescriptive Ignition Barrier: Where SWD Quik-Shield® | YETI insulation is installed within attics or crawl spaces, and where entry is made only for service of utilities, an ignition barrier must be installed in accordance with IBC Section 2603.4.1.6 or IRC Sections R303.5.3 and R303.5.4, as applicable. The ignition barrier must be consistent with the requirements for the type of construction required by the applicable Code and must be installed in a manner so that the foam plastic insulation is not exposed. The insulation, as specified in this section, may be installed in unvented attics and unvented enclosed rafter assemblies in accordance with IBC Section 1202.3 or IRC Section R806.5. 5.4.2 Application without a Prescriptive Ignition Barrier: SWD Quik-Shield® | YETI insulation may be installed in attics and crawl spaces without the ignition barrier prescribed in IBC Section 2603.4.1.6, and IRC Sections R303.5.3 and R303.5.4, as described in Sections 5.4.2.1, and 5.4.2.2 subject to the following conditions: a. Entry to the attic or crawlspace is only to service utilities and no storage is permitted. b. There are no interconnected attic or crawl space areas. c. Air in the attic is not circulated to other parts of the building. d. Attic ventilation is provided when required by IBC Section 1203.2 or IRC Section R806.1, as applicable, except when insulation is permitted in unvented attics in accordance with IBC Section 1202.3, or IRC Section R806.5. e. Under-floor (crawl space) ventilation is provided in accordance with IBC Section 1202.4 or IRC Section R408.1, as applicable. f. Combustion air is provided in accordance with IMC (International Mechanical Code®) Section 701. The insulation may be installed in unvented attics as described in this section in accordance with IBC Section 1202.3 or IRC Section R806.5, when applied at a minimum thickness of 1 inch. 5.4.2.1 Assembly No. 1: SWD Quik-Shield® | YETI insulation may be applied to the underside of roof sheathing, to roof rafters and to walls; and in crawl spaces; the insulation may be spray-applied to the underside of wood floors and to walls, as described in this section. The thickness of the foam plastic applied to vertical surfaces must not exceed 5-1/2 inches, and the thickness applied to the underside of the wood floor or roof sheathing must not exceed 9-1/2 inches. The foam plastic is not required to be coated. The ignition barrier required by IBC Section 2603.4.1.6 and IBC Sections R303.5.3 and R303.5.4 may be omitted. 5.4.2.2 Use on Attic Floors: SWD Quik-Shield® | YETI insulation may be installed at a maximum thickness of 11- 1/2 inches between joists in attic floors without a coating and without an ignition barrier on the attic side of the insulation. The insulation must be separated from the interior of the building by an approved thermal barrier. Code Compliance Research Report CCRR-0478 Page 4 of 8 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 intertek.com/building PCA-101 Version: 21 December 2017 SFT-CCRR-OP-40b 5.5 Water-Resistive Barrier: SWD Quik-Shield® | YETI insulation may be used as an alternative to the water-resistive barrier prescribed in IBC Section 1403.2 and IRC Section R703.2, when installed on exterior walls as a continuous layer of 1.3-inch minimum thickness. 5.6 Use on Exterior Walls in Types I, II, III, and IV Construction: When used in exterior walls of Types I, II, III, or IV construction, the assembly must be installed as described in Table 4. The potential heat of the foam plastic in any portion of the wall must not exceed 7367 Btu/ft². 5.7 Duct Insulation: SWD Quik-Shield® | YETI insulation may be applied to residential ducts in compliance with IRC Section M1601.3 to a maximum thickness of 4 inches. The material must be protected in accordance with the ignition barrier requirements of either Section 5.4.1 or 5.4.2. 6.0 CONDITIONS OF USE The SWD Quik-Shield® | YETI spray-applied insulation described in this Research Report complies with, or is a suitable alternative to, what is specified in those codes listed in Section 1.0 of this report, subject to the following conditions: 6.1 Installation must comply with this Research Report, the manufacturer’s published installation instructions, and the applicable Code. In the event of a conflict, this report governs. 6.2 The insulation must be separated from the interior occupied spaces of the building by an approved thermal barrier, as described in Sections 5.3 and 5.4. 6.3 The insulation thickness must not exceed that noted in sections 4.1.1, 5.3, 5.4, and 5.6. 6.4 The insulation must be protected from the weather during and after application as specified in the manufacturer’s instructions. 6.5 A vapor barrier must be installed when required by the applicable Code. 6.6 The insulation must be applied by contractors approved by SWD Urethane. 6.7 SWD Quik-Shield® | YETI may be used in exterior walls of buildings of Type I, II, III, or IV construction, when the construction is as described in Section 5.6. 6.8 Use of the insulation in areas where the probability of thermite infestation is “very heavy” must be in accordance with IBC Section 2603.8 or IRC Section R305.4, as applicable. 6.9 Use of the insulation in fire-resistance-rated construction is outside the scope of this report. 6.10 Jobsite certification and labeling of the insulation must comply with IRC Section N1101.10, N1101.14 and IECC Section C303.1 or R303.1 and R401.3, as applicable. 6.11 The product is manufactured under a quality control program with inspections by Intertek Testing Services NA, Inc. 7.0 SUPPORTING EVIDENCE 7.1 Reports of tests in accordance with ASTM C411, ASTM C518, ASTM E84, ASTM E283, ASTM E96, ASTM E970, ASTM E2178, NFPA 286, NFPA 285, UL 1715, and NFPA 259. 7.2 Data in accordance with the ICC-ES Acceptance Criteria for Spray-applied Foam Plastic Insulation (AC377), dated April 2020, including reports of tests in accordance with Appendix X. 7.3 Data in accordance with ICC 1100 (2019). 7.4 Research Reports for evaluation of data in accordance with ICC-ES Acceptance Criteria for Fire-protective Coatings Applied to Spray-applied Foam Plastic Insulation Installed without a Code-prescribed Thermal Barrier (AC456), dated October 2015. 7.5 Intertek Listing Report "SWD Quik-Shield | YETI", on the Intertek Directory of Building Products. Code Compliance Research Report CCRR-0478 Page 5 of 8 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 intertek.com/building PCA-101 Version: 21 December 2017 SFT-CCRR-OP-40b 8.0 IDENTIFICATION The A and B components of the insulation are identified with the manufacturer’s name (SWD Urethane), address and telephone number, the product name (SWD Quik-Shield® | YETI), the component type (A or B component), the mixing instructions, the density, the flame-spread and smoke- developed indexes, the shelf-life and date of manufacture, the Intertek Mark as shown below, and the Code Compliance Research Report number (CCRR-0478). 9.0 OTHER CODES This section is not applicable. 10.0 CODE COMPLIANCE RESEARCH REPORT USE 10.1 Approval of building products and/or materials can only be granted by a building official having legal authority in the specific jurisdiction where approval is sought. 10.2 Code Compliance Research Reports shall not be used in any manner that implies an endorsement of the product by Intertek. 10.3 Reference to the https://bpdirectory.intertek.com is recommended to ascertain the current version and status of this report. This Code Compliance Research Report (“Report”) is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Report. Only the Client is authorized to permit copying or distribution of this Report and then only in its entirety, and the Client shall not use the Report in a misleading manner. Client further agrees and understands that reliance upon the Report is limited to the representations made therein. The Report is not an endorsement or recommendation for use of the subject and/or product described herein. This Report is not the Intertek Listing Report covering the subject product and utilized for Intertek Certification and this Report does not represent authorization for the use of any Intertek certification marks. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Code Compliance Research Report CCRR-0478 Page 6 of 8 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 intertek.com/building PCA-101 Version: 21 December 2017 SFT-CCRR-OP-40b TABLE 1 - PROPERTIES EVALUATED PROPERTY 2024 IBC SECTION1 2024 IRC SECTION1 2024 IECC SECTION1 Physical properties 2603.1.1 Not required Not required Surface-burning characteristics 2603.3 R303.3 Not applicable Alternatives to thermal barrier/ ignition barrier 2603.4 R303.4 Not applicable Air permeability 1202.3 R806.5 C402.6.2.3.1 Vapor retarder 202 1404.3 R202 R702.7 Not applicable Thermal resistance 1301 N1101.10 N1102 C303.1 R303.1 Water-resistive Barrier 1403.2 R703.2 Not applicable Exterior walls of Types I – IV construction 2603.5 Not applicable Not applicable 1 Section numbers may be different for earlier versions of the International codes. TABLE 2 – COATING AND FOAM ASSEMBLIES FOR USE WITHOUT A CODE-PRESCRIBED THERMAL BARRIER Foam Insulation Product Intumescent Coating Product Assembly Details Test Method Insulation Details Intumescent Coating Details Maximum Average Thickness, inches Minimum Average Thickness, mils Theoretical Application Rate Vertical (e.g. wall) Overhead (e.g. ceiling) Wet Film (WFT) Dry Film (DFT) gal/100 ft2 QS-YETI DC315 11-1/4 11-1/4 20 13 1.3 NFPA 286 QS-YETI 60-60A 9-1/2 9-1/2 20 13 1.3 NFPA 286 QS-YETI Fireshell F10E 6 8 17 11 1.05 NFPA 286 QS-YETI DC315 5-1/2 9-1/2 14 9 0.9 NFPA 286 QS-YETI NO-BURN® Plus ThB 5 8 14 9 0.85 UL1715 Code Compliance Research Report CCRR-0478 Page 7 of 8 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 intertek.com/building PCA-101 Version: 21 December 2017 SFT-CCRR-OP-40b Table 3 – SWD Quik-Shield® | YETI THERMAL RESISTANCE (R-Values)1,2,3 THICKNESS (inches) R-VALUE (°F·ft²·h/Btu) 1 7.5 1.5 11 2 15 2.5 19 3 23 3.5 26 4 30 5 38 5.5 41 6 45 7.5 56 8 60 9.5 71 10 75 11.25 84 1 R-values are calculated based on tested K-values at 1 inch thickness and 3.5 inch thickness. 2 R-values less than 10 are rounded to the nearest 1/10th; greater than 10 are rounded to the nearest whole number. 3 To determine R-values for thicknesses not listed, R = 7.5/inch Code Compliance Research Report CCRR-0478 Page 8 of 8 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 intertek.com/building PCA-101 Version: 21 December 2017 SFT-CCRR-OP-40b TABLE 4 – NFPA 285 COMPLYING WALLS WITH SWD Quik-Shield® | YETI Base Wall One layer 5/8 inch thick Type X gypsum wallboard complying with ASTM C36 or C1396 on interior, installed over 35/8 to 6 inch deep, No. 18 gage, C- shaped, steel studs spaced a maximum of 24 inches on center. Openings must be framed with No. 18 gage steel. Gypsum wallboard must be attached with No. 6, 11/4 inch long self-tapping screws located 8 inches on center along the perimeter and 12 inches on center in the field of the wallboard. Gypsum wallboard joints must be taped and treated with joint compound in accordance with ASTM C840 or GA-216 Fire-Stopping in Stud Cavity at Floorlines 4 pounds per cubic feet mineral wool (e.g., Thermafiber) in each stud cavity at each floor line. The insulation is friction fit between studs. Cavity Insulation Minimum 1 inch thick Quik-Shield YETI applied to backside of exterior sheathing. Air gap may not exceed 21/2 inches. Exterior Sheathing Minimum 5/8 inch thick listed or certified exterior-type gypsum sheathing Exterior Insulation- Use Either 1 or 2 1. None 2. Any noncombustible insulation which meets ASTM E136. Insulation must be attached per manufacturer instructions and must incorporate a noncombustible water-resistive barrier or air/vapor barrier when specified. Exterior Cladding Any noncombustible exterior wall covering material. Details of the exterior wall covering must be provided by the report holder, designer or specifier to the code official, with a fire engineering analysis demonstrating that the addition of the wall covering will not negatively affect conformance of the assembly with the requirements of IBC Section 2603.5.