Loading...
HomeMy WebLinkAboutOWTS Permit Card Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable Project Address: 611 Scutter Lane, Rifle, CO 81650 Parcel No.: 212728400387 Owner Name: Dale and Mollie Bauer Owner Phone: (970) 618-7435 Designed By: Huddleston Berry Engineering & Testing Designer Phone: (970) 255-8005 Number of Bedrooms: _3_ Minimum Tank Capacity: 1,000-gallon Minimum Absorption: 756 ft2 OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Number _SEPT-9581_______________________________ Permit Type X New X Repair X Remodel/addition X Tank only Issue Date _12/31/2025____________________ Expiration Date_12/31/2026_________________ Permit Conditions: This OWTS Permit is approved on the condition of compliance with the report and design as submitted by Huddleston Berry Engineering & Testing dated October 30, 2025. Changes to the design and permit must be approved by Garfield County Public Health and the designer prior to construction. The new OWTS will serve a proposed three-bedroom residence. The new OWTS components will consist of a new 1,000-gallon two compartment septic tank on the CDPHE approved list, set level with access to grade and an effluent filter installed in the outlet tee of the tank. Effluent will gravity flow to a new distribution box set level with access to grade which will distribute effluent to 768 ft2 of STA. The new STA will consist of one four-row gravelless chamber bed consisting of 16 ‘Quick 4’ chambers per row for a total of 64 chambers. Inspection ports will be installed at each corner of the bed. Maintain all setbacks and elevations as designed. To assist in scheduling, please contact Garfield County Public Health (970-945-6614 ext. 8150) to notify the start of OWTS construction. Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final inspection of the installed system prior to backfill. NO OWTS COMPONENT SHALL BE BACKFILLED WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction, and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection, and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as-built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of the system will be issued. 12/31/2025 Issued By: Garfield County Environmental Health Department Date