HomeMy WebLinkAboutInstallation Observation ReportCBO Inc.
129 Cains Lane
Carbondale, CO 81623
970.309.5259
carla.ostberg@gmail.com
December 1, 2025 Project No. C1966
Ross and Lindey Brooks
lindseynunnbrooks@gmail.com
Onsite Wastewater Treatment System (OWTS) Installation Observations
507 Westbank Road
Garfield County, Colorado
Permit SEPT -9569
Ross and Lindsey,
CBO Inc. observed the installation of the onsite wastewater treatment system (OWTS) on November 28,
2025 for the subject property. Alpine Excavation and Land Clearing installed the system.
The OWTS design is based on 4-bedrooms. An average daily wastewater flow of 525 GPD was used.
A PVC liner was placed in the ditch within 50-feet of any OWTS component.
The new, 4-inch diameter Schedule sewer line was placed as close to the foundation as possible. A
section of cast iron sewer line remains under the garage apron extending into the house. The new sewer
line has a double-sweep clean out and a 2% grade to the septic tank.
The system installation included a 1500-gallon, two-compartment Infiltrator® poly septic tank with an
Orenco® Biotube effluent filter on the outlet tee. This filter must be cleaned annually, or as needed.
Risers bring the manhole lids to grade for access.
A new, 4-inch diameter SDR-35 sewer line was installed between the septic tank and new distribution
box down the steep hillside. The sewer line was encased in 6-inch diameter Schedule 40 pipe 10-feet on
each side of the ditch crossing. A double-sweep clean out was placed on the 4-inch SDR-35 sewer line
after the ditch.
Effluent gravity flows to a distribution box, and then to two gravelless chamber beds. The distribution box
was accessible from grade with flow equalizers installed on each outlet pipe in the distribution box to
assure equal flow to each bed.
A 4-inch diameter SDR-35 level manifold was installed to connect each row of the chamber beds. The
chamber beds consist of 3 rows of 11 ‘Quick 4’ Low Profile Plus Standard Infiltrator® chambers for a total
of 66 chambers and 792 square feet of infiltrative area. There was 6-feet of undisturbed soil between the
beds. Inspection ports were installed at each corner of the beds. Ports may be cut to grade and placed
in sprinkler boxes for access.
Irrigation directly over the soil treatment area (STA) should be minimized.
.
The OWTS was generally installed according to specifications. This observation is not a guarantee of
workmanship and/or parts and materials. CBO Inc. should be notified if changes are made to the OWTS
in the future. Any additional OWTS construction must be according to the county regulations.
LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must
have documented and demonstrated knowledge of the requirements and regulations of the county in
which they are working. The quality of the installation is dependent on the expertise of the installer, soil
type, and weather conditions.
Please call with questions.
Sincerely,
CBO Inc.
Carla Ostberg, MPH, REHS
View of STA
Distribution box connecting beds
Distribution box Tracer wire used on all piping / pipes well bedded
Septic tank View of sewer line looking towards house
Sewer line down steep hillside Ditch crossing / Ditch lined Clean out before setpic tank
Effluent filter Inlet tee
Sewer line from garage to side of tank / New sewer line adapted to cast iron / cast iron remains under apron
Ditch liner re-installed Final grading
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 507 Westbank Road, GWS, CO 81601 Parcel No.: 2395021007
Owner Name: Lindsey Brooks Owner Phone: (719) 649-2137
Designed By: CBO Inc. Designer Phone: (970) 309-5259
Number of Bedrooms: _4_ Minimum Tank Capacity: 1,250-gallon Minimum Absorption: 735 ft 2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT-9569_______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _11/17/2025____________________ Expiration Date_11/17/2026_________________
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by CBO Inc. dated October 17, 2025. Changes to the design and permit must be approved
by Garfield County Public Health and the designer prior to construction.
The new OWTS will serve a proposed four-bedroom residence. An additional profile pit and soil
evaluation must be completed prior to installation of any OWTS components. The new OWTS
components will consist of a new 1,500-gallon two compartment septic tank on the CDPHE approved
list, set level with access to grade and an effluent filter installed in the outlet tee of the tank. The
effluent line must be encased for the duration of the lined ditch crossing and for 10 feet on either
side of the ditch. Effluent will gravity flow to a new distribution box set level with access to grade
which will distribute effluent to 792 ft2 of STA via two level manifolds. The new STA will consist of
two gravelless chamber beds consisting of 3 rows of 11 ‘Quick 4’ chambers per bed for a total of 66
chambers. Inspection ports will be installed at each corner of each bed. Maintain all setbacks and
elevations as designed. The existing septic tank must be abandoned by crushing or removal.
To assist in scheduling, please contact Garfield County Public Health (970-945-6614 ext. 8150) to
notify the start of OWTS construction. Contact the designer and Garfield County Public Health at
least 48 hours prior to requesting final inspection of the installed system prior to backfill. NO OWTS
COMPONENT SHALL BE BACKFILLED WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC
HEALTH AND THE DESIGNER.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as-built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
11/17/2025
Issued By: Garfield County Environmental Health
Department
Date
832‐R‐13‐002