Loading...
HomeMy WebLinkAboutOWTS Permit Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable Project Address: 405 Mid Valley Drive, New Castle, CO 81647 Parcel No.: _218107302006 Owner Name: William H. DuBois Owner Phone: (970) 379-1864 Designed By: CBO, Inc. Designer Phone: (970) 309-5259 Number of Bedrooms: _3 Minimum Tank Capacity: 1000-gallon Minimum Absorption: 818.18 ft2 OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Number _SEPT-9584_______________________________ Permit Type X New X Repair X Remodel/addition X Tank only Issue Date _01/06/2026____________________ Expiration Date_01/06/2027_________________ Permit Conditions: This OWTS Permit is approved on the condition of compliance with the report and design as submitted by CBO, Inc. dated October 16, 2025. Changes to the design and permit must be approved by Garfield County Public Health and the designer prior to construction. The new OWTS will serve an existing three-bedroom residence. The system will consist of a new two-compartment 1,000- gallon septic tank with access at grade and an effluent filter installed in the outlet. A screened high-head pump will be housed in a 500-gallon single-compartment pump chamber downstream from the septic tank. Effluent will be pumped to an ADV set at the high point of the system that will distribute effluent to 819 ft2 of STA. The dose volume from the pump shall be 85 gallons pumped 5-6 times per day. The specified pump for the project has a 28.6 gallon-per-minute pump rate with a total dynamic head of 27.9 feet. The new STA will consist of one 13 ft by 60 ft unlined sand filter bed constructed of two feet of secondary sand media. The bed will consist of 4 rows of 1.5-inch Schedule 40 PVC distribution laterals placed in GeoMat distribution media, with 5/32-inch orifices every 3-feet on center and the laterals ending in 90-degree sweeping bends and flushing valves at the distal end. The orifices are to be facing downward and be equipped with splash plates. Inspection ports are to be installed in each corner of the bed at minimum. The residual head (squirt height) at the end of the system is to be 5-feet. Maintain all setbacks and elevations as designed. To assist in scheduling, please contact Garfield County Public Health (970-945-6614 ext. 8150) to notify the start of OWTS construction. Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final inspection of the installed system prior to backfill. NO OWTS COMPONENT SHALL BE BACKFILLED WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction, and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection, and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as-built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of the system will be issued. 01/06/2026 Issued By: Garfield County Environmental Health Department Date