HomeMy WebLinkAboutDuct Test ReportTesting Company: Name:C5 Energy Inspections Address:209 River Ridge Dr Grand Junction , CO 81503 Phone: 9702503152 www.c5energyinspections.com Technician: Name:Brian Chesney Credentials:BPI Certified ID#5068969 Email:c5energygj@gmail.com Building Information: Project ID:19 Roan creek dr Address:19 Roan Creek Drive Parachute, Colorado 81635 Geo-Tag Data:Latitude: 39.457387 Longitude: -108.029016 Timestamp: 2026-01-12 10:35:09 Customer Information: Name: Address: Measured Leakage:2.56 CFM25/100 ft² Leakage Target:3.00 CFM25/100 ft² Compliance with Leakage Target:Pass Test ID:Duct test Purpose of Test:Duct Total (IECC) Measured CFM25:53.7 Conditioned Floor Area:2,095.0 ft²AH Flow: 0.0 cfm Coefficient (C):7.8 Exponent (n): 0.600 (assumed) Test Standard:RESNET 380 Total Duct Leakage Test Mode: Pressurize Test Characteristics:Time Average Period: 10 seconds Test Date and Time:2026-01-12 10:52:55 Duct Leakage Test Test Readings: Target (Pa)Duct (Pa)Fan (Pa)Flow (cfm)Config 25.0 25.6 -77.1 54.5 Ring 3 Test Equipment: Flow Device:Duct Blaster B Fan Pressure Gauge:DG1000 Serial #: 13229 Calibration Date: 2024-08-27 Deviations from Standard: None Comments: None Duct Leakage Test Page 2 of 2Report by TEC Auto Test 1.10.2 (3), © 2025 The Energy Conservatory, Inc.