Loading...
HomeMy WebLinkAboutOWTS Permit Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable Project Address: 315 Westbank Road, GWS, 81601 Parcel No.: _239502103001 Owner Name: Thompson, Family Joint Rev. Trust Owner Phone: (970) 379-5883 or c/o Kelli Broughton, RE/MAX Country (970) 984-9600 Designed By: Sopris Engineering Designer Phone: (970) 704-0311 Number of Bedrooms: _5 Minimum Tank Capacity: 1500-gallon Minimum Absorption: 700 ft 2 OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Number _SEPT-9635_______________________________ Permit Type X New X Repair X Remodel/addition X Tank only Issue Date _1/16/2026____________________ Expiration Date_1/16/2027_________________ Permit Conditions: This OWTS Permit is approved on the condition of compliance with the report and design as submitted by Sopris Engineering dated January 15, 2026. Changes to the design and permit must be approved by Garfield County Public Health and the designer prior to construction. The new OWTS will serve a four-bedroom residence with capacity for a future fifth bedroom. The system will consist of a new two-compartment 1,500-gallon septic tank with access at grade and an effluent filter installed in the outlet. The existing tank must be abandoned by crushing. Two new screened high-head pumps will be housed in a 500-gallon single- compartment pump chamber downstream from the septic tank. Effluent will be pumped via two independent pressure transport lines to two level manifolds that will distribute effluent to 720 ft2 of STA. The dose volume from the pump shall be 41.2 gallons pumped ~15 times per day. The specified pump for the project has a 38 gallon-per-minute pump rate with a total dynamic head of 20.6 feet. The new STA will consist of two 9 ft by 40.5 ft chamber beds. Each bed will consist of 3 rows of 8 ‘ARC 36’ chambers (48 chambers total). Distribution laterals are to be 1 1/2 inch Schedule 40 PVC, with 5/32- inch orifices every 2.5 -feet on center and the laterals ending in 90-degree sweeping bends and flushing valves at the distal end. The orifices are to be facing upward, except for the last orifices (which shall face downward and be equipped with orifice shields). Inspection ports are to be installed in each corner of the bed at minimum. The residual head (squirt height) at the end of the system is to be 5-feet. Maintain all setbacks and elevations as designed. To assist in scheduling, please contact Garfield County Public Health (970-945-6614 ext. 8150) to notify the start of OWTS construction. Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final inspection of the installed system prior to backfill. NO OWTS COMPONENT SHALL BE BACKFILLED WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction, and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection, and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as-built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of the system will be issued. 1/16/2026 Issued By: Garfield County Environmental Health Department Date