SOIL PROFILE
PIT 01-05-25
INSTALL 540 GALLON INFILTRATOR IM SINGLE COMPARMENT
EFFLUENT DOSING TANK OR EQUAL W/ 30" DIA. BY 48" DEEP
RIBBED PVC RISER W/ LID AT THE SURFACE. INSTALL ORENCO
BIOTUBE DUPLEX EFFLUENT PUMP ASSEMBLY. (PVU57-1819-L)
W/P300511 PUMPS), W/ 2 SEPARATE 1.5" DISCHARGE ASSEMBLIES.
NO PRE ASSEMBLED DISCHARGE ASSEMBLIES WITH CHECK VALVES
OR ISOLATION BALL VALVES ARE REQURIED. USE INDIVIDUAL PARTS
INSTALL ELECTRICAL WIRES IN CONDUIT FROM HOUSE
ELECTRIC SERVICE TO REMOTE CONTROL PANEL
INSTALL 1.5" FLUSH BALL VALVE ON DISTAL END OF EACH
DISTRIBUTION LATERAL CENTERED BELOW EACH INSPECTION
PORT (TYP. END EA. ROW)EXTERNAL SPLICE BOX INSTALLED WITH
ELECTRICAL/CONTROL WIRES FROM CONTROL
PANEL (SEE ELECTICAL/CONTROL NOTES)
4" SCHD-40 PVC GRAVITY SEWER PIPE @ 2%,
INSTALL 4" RISER PIPE INSPECTION PORT PIPE FROM DISTAL END
CHAMBER IP FLANGE. EXTEND RISER W/ PUSH ON CAP 3" BELOW
FINISH GRADE & COVER WITH 6" DIA. VALVE BOX SET WITH LID 1"
ABOVE FINISH GRADE (TYP. EACH CHAMBER ROW END CAP)
INSTALL END CAPS AT END OF ALL CHAMBERS ROWS
1.5" PVC MANIFOLD WITH CONNECTION FITTINGS
TO EACH PERFORATED DISTRIBUTION LATERAL
INSTALL 2-COMPARTMENT 1500-GALLON PLASTIC SEPTIC TANK
(INFILTRATOR IM-1530 SEPTIC TANK) INSTALL WITH (2) 24" DIA. BY
24" DEEP RIBBED PVC RISERS W/ LIDS AT THE SURFACE.
DEPTH TO TOP OF TANK FROM PROPOSED GRADE IS APPROX. 2.0'.
1 1/2" PVC SCHD-40 CUSTOM PERFORATED DISTRIBUTION LATERALS.
DRILL 5/32-INCH DIA. ORIFICES EVERY 2.5-FEET ALONG PIPE.
ELECTRICAL AND CONTROL NOTES:
1. INSTALL AN ORENCO MODEL S1ETMCT, DUPLEX CONTROL PANEL, 110
VOLT ELECTRICAL SERVICE FOR PUMPS AND CONTROLS FROM HOUSE
CIRCUIT BREAKER OR OPTIONAL MOUNTED REMOTE SUB-PANEL TO BE
INSTALLED. INSTALL CONTROL PANEL ON EXTERIOR WALL MOUNT WITH
SOUND PROOF BOARD BETWEEN BACK OF PANEL AND WALL.
2. ELECTRIC SERVICE PANEL TO HAVE 2 DEDICATED 20 AMP CIRCUITS W/
12-GAUGE, 12-2 WIRE W/ GROUND FOR PUMPS POWER AND 1 DEDICATED
MIN. 10 AMP CIRCUIT W/ MIN. 14 GAUGE , 14-2 WIRE W/ GROUND
INSTALLED IN CONDUIT TO CONTROL PANEL
3. ELECTRICIAN TO SET PANEL AND CONNECT PUMP AND CONTROL
ELECTRICAL SUPPLY WIRES TO REDUNDANT CIRCUIT BREAKERS IN
CONTROL PANEL.
4. ELECTRICIAN OR SERVICE PROVIDER TO INSTALL 12-2 WIRES W/ GROUND
FOR PUMP POWER AND 14-6, DIRECT BURY TRAY CABLE FOR FLOATS, IN
CONDUIT(S) FROM CONTROL PANEL TO EXTERNAL SPLICE BOX MOUNTED
ON DOSING TANK ACCESS RISER
5. QUALIFIED SERVICE PROVIDER TO CONNECT INSTALLED WIRES FROM
CONTROL PANEL TO THE RESPECTIVE PUMP AND FLOAT WIRES INSTALLED
IN THE EXTERNAL SPLICE BOX
SOIL TREATMENT AREA
INSTALL 48 ARC-36 CHAMBERS IN TWO BEDS WITH 3 ROWS OF 8
CHAMBERS PER ROW FOR A TOTAL ABSORPTION AREA OF 700 S.F.
THE BOTTOM OF EACH BED TO BE EXCAVATED TO AN AVERAGE
DEPTH OF 30 INCHES BELOW THE EXISTING SURFACE GRADES.
THE ABSORPTIVE SURFACE TO BE SCARIFIED AT LEVEL GRADE.
CHAMBERS TO BE COVERED WITH FILTER FABRIC AND BACKFILLED
TO A MINIMUM 3" ABOVE EXISTING PERIMETER GRADES
INSTALL 4" INSPECTION PORT EXTEND PIPE RISER FROM END
CHAMBER IP FLANGE TO FINISH GRADE W/ PUSH ON CAP & COVER
WITH 8" DIA. VALVE BOX SET WITH LID 4" ABOVE FINSH GRADE
(TYP. EACH PROXIMAL & DISTAL END CHAMBER EACH ROW )
E
T
C
E
T
C
E
T
C
1.
5
'
'
1.
5
'
'
1.
5
'
'
EX 4" PVC EFFLUENT PIPE O BE ABANDONED IN PLACE
EXISTING 2-COMPARTMENT 1250-GALLON CONCRETE SEPTIC TANK
PUMP, BREACH, CRUSH LID & BACKFILL TO ABANDON IN PLACE
EX 4" CI SEWER PIPE
RECOVER CUT & ABANDON
EXISTING SEEPAGE PIT TO BE ABANDONED IN PLACE
DUAL 1.5" SCHD-40 TRANSPORT PIPES W/ 1.5' MIN. DEPTH OF
BURY. INSTALL AT MIN. 2.5% FOR DRAINAGE BACK TO TANK
INSTALL (2) 4" SDR-35 RISER PIPE PIEZOMETER INSPECTION PORT WITH PUSH ON
CAP AT EACH CORNER OF EACH BED. EXTEND VERTICALLY FROM 3" BELOW
FINISH GRADE TO INFILTRATIVE SURFACECOVER WITH 6" DIA. VALVE BOX SET
WITH LID 1" ABOVE FINISH GRADE (TYP. EACH PROXIMAL CORNERS OF EA. BED)
INSTALL 4" 2-WAY CLEANOUT
10.0'
10.0'
50.0'
20.0'
6.0'
9.0'
40.5'
6.0'
INSTALL ORENCO S1 PUMP CONTROL PANEL
6X6 POST/STRUT OR WALL-MOUNTED W/ SOUND
BOARD INSTALLED ON BACK OF PANEL.
OPTIONAL ELECT SUB-PANELMAY BE CONSIDERED
DATE REVISION
TCP - CORRECTED
NUMBER OF CHAMBERS
IN EACH BED.
C-1.0
DRAWING NO.
TITLE
G:
\
2
0
2
6
\
3
6
0
0
0
3
1
5
W
E
S
T
B
A
N
K
\
C
I
V
I
L
\
C
I
V
I
L
D
W
G
S
\
D
E
\
3
6
0
0
0
-
D
E
-
O
W
T
S
P
L
A
N
-
T
C
P
R
E
V
.
2
0
2
6
-
0
1
-
1
5
.
D
W
G
-
J
a
n
1
5
,
2
0
2
6
-
3
:
1
5
p
m
NO
R
T
H
01/15/26
OWTS DESIGN
CONSTRUCTION
PLAN
1 inch = ft.
( IN FEET )
GRAPHIC SCALE
020 20 40
20
8010
MEMBER UTILITIES
FOR THE MARKING OF UNDERGROUND
BEFORE YOU DIG, GRADE, OR EXCAVATE
CALL 2-BUSINESS DAYS IN ADVANCE
Know what's below.
before you dig.Call
R
36000.01JOB NO.
DATE:01-08-25
DESIGNED BY
DRAWN BY
CHECKED BY
PER
PER
YTN
TH
O
M
P
S
O
N
,
F
A
M
I
L
Y
P
R
O
P
E
R
T
Y
31
5
W
E
S
T
B
A
N
K
R
D
,
G
L
E
N
W
O
O
D
S
P
R
I
N
G
S
,
GA
R
F
I
E
L
D
C
O
U
N
T
Y
,
C
O
OW
T
S
C
O
N
S
T
R
U
C
T
I
O
N
P
E
R
M
I
T
A
P
P
L
I
C
A
T
O
N
SO
P
R
I
S
E
N
G
I
N
E
E
R
I
N
G
L
L
C
50
2
M
A
I
N
S
T
R
E
E
T
S
U
I
T
E
A
3
C
A
R
B
O
N
D
A
L
E
C
O
8
1
6
2
3
(9
7
0
)
7
0
4
0
3
1
1
s
o
p
r
i
s
e
n
g
i
n
e
e
r
i
n
g
.
c
o
m
'
24"
9'.
12" - 18"
NOTE:
THE CHAMBER BED MUST BE LEVEL. INSTALL CHAMBERS WITH INLET AND END
CAPS OVER NATIVE SCARIFIED SOIL. INSTALL INDIVIDUAL DISTRIBUTION
LATERALS TO THE HEAD OF EACH CHAMBER ROW FROM A COMMON MANIFOLD
FOR EACH BED. CUSTOM PERFORATED PIPE TO BE LAID ON TOP OF THE
ABSORPTIVE SURFACE WITH ORIFICES ORIENTED UPWARD EXCEPT THE FIRST
AND LAST ORIFICES TO BE ORIENTED DOWNWARD. INSTALL A 4" VERTICAL
INSPECTION RISER FROM THE MOLDED CUT OUT ON THE LAST CHAMBER IN
EACH ROW. INSTALL A BALL VALVE AT THE END OF THE DISTRIBUTION LINE
ACCESSIBLE FROM THE INSPECTION PORT TO ALLOW FLUSHING OF THE LINE.
1.5" TEE CONNECTION
1.5" SCHD-40 PVC
DISTRIBUTION MANIFOLD
SEED AND MULCH FINISH SURFACE
MAINTAIN SUITABLE VEGETATIVE COVER
CROWN FIELD TRENCH TO
DIVERT SURFACE WATER
EXISTING GRADE
UNDISTURBED EARTH
SCREENED BACKFILL
NATIVE SOIL
CHAMBER UNIT ( SPRAY SHIELD)
QUICK-4 OR ARC-36 BIO DIFFUSER
PRESSURE DISTRIBUTION
CONNECTED THROUGH END CAP TO
CUSTOM PERFORATED LATERAL PIPE
SCARIFY/TILL BOTTOM SURFACE AND
EXCAVATION SIDE WALLS
NATIVE SILT LOAM
3'1.5'
CUSTOM PERFORATED PRESSURE PIPE WITH ORIFICES
AT 12 O'CLOCK. SECURE PIPE WITH PUSH IN STAPLES
TOPSOIL
SET 4" INSPECTION PORT RISER PIPE ON END CAP OR
END CHAMBER PRE FORMED PENETRATION, SECURE
WITH SHORT SCREWS THROUGH FLANGE INTO PIPE 6" VALVE BOX
4" PVC INSPECTION PORT RISER
4" PUSH ON CAP
QUICK-4 INFILTRATOR
OR EQUAL ARC-36 CHAMBER
SET 4" INSPECTION PORT RISER PIPE ON END CAP OR
END CHAMBER PRE FORMED PENETRATION SECURE
WITH SHORT SCREWS THROUGH FLANGE INTO PIPE
6" VALVE BOX
4" INSPECTION PORT RISER
4" PUSH ON CAP
4" INSPECTION PORT RISER
DISTRIBUTION SYSTEM NOTES:
1. FILTERED EFFLUENT WILL DISCHARGE VIA A DUPLEX HIGH HEAD PUMP BIOTUBE
DISCHARGE ASSEMBLY WITH INDIVIDUAL TRANSPORT PIPES TO A MANIFOLD PIPE AT
THE HEAD OF EACH CHAMBER BED. THE SYSTEM WILL BE OPERATE TO PROVIDE
ALTERNATE DOSING TO EACH BED. THE CONTROL PANEL WILL HAVE A LAG SWITCH.
2. THE DISTRIBUTION SYSTEM WILL BE INSTALLED TO ALLOW FOR EFFLUENT TO BE
ALTERNATELY AND EQUALLY DISTRIBUTED ACROSS THE ABSORPTION SURFACE IN EACH
CHAMBER BED VIA INDIVIDUAL CUSTOM PERFORATED DISTRIBUTION LATERALS
INSTALLED ON THE SURFACE ALONG THE ENTIRE LENGTH OF THE CHAMBER ROWS. A
BALL VALVE WILL BE INSTALLED ON THE TERMINAL END OF EACH DISTRIBUTION
LATERAL CENTERED BELOW A 4" INSPECTION PORT.
3. THE MINIMUM SLOPE OF THE TRANSPORT PIPE FROM THE TANK'S DOSING
COMPARTMENT TO THE BED MANIFOLD SHALL BE A MINIMUM 2.5% UPWARD SLOPE
TO ALLOW FOR DRAINBACK TO THE TANK.
OWTS SYSTEM NOTES:
1. ALL MATERIALS AND INSTALLATION SHALL CONFORM TO STATE AND COUNTY
ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) REGULATIONS.
2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT ALL UTILITY
COMPANIES FOR FIELD LOCATIONS OF UTILITIES PRIOR TO CONSTRUCTION AND
EXCAVATION.
3. ALL SEWER LINES TO BE SDR-35 OR SCHEDULE 40 P.V.C. PIPE UNLESS NOTED
OTHERWISE.
4. INSTALL A TWO-WAY CLEAN OUT ON THE SERVICE LINE FROM THE HOUSE AND AN
ADDITIONAL CLEANOUT WITHIN 100' SECTION OF EFFLUENT DISCHARGE PIPE .
5. THE SEPTIC TANK SHALL BE INSTALLED LEVEL ON COMPACTED EARTH. INSTALL
WATERTIGHT RISERS AS NECESSARY TO BRING ALL REQUIRED ACCESS POINTS TO
THE FINISHED SURFACE GRADE. BACKFILL WITH SUITABLE NATIVE SOIL FREE OF
BOULDER AND ROCK IN EXCESS OF 3" DIAMETER.
6. A SANITARY BAFFLE TEE IS REQUIRED ON THE SEPTIC TANK INLET AND OUTLET.
INSTALL THE INLET AND OUTLET TEES PLUMB AND IN A POSITION TO ALLOW EASY
INSPECTION AND MAINTENANCE OF TANK FROM THE TANK RISERS.
7. INSTALL A 4" EFFLUENT FILTER ON THE 4" OUTLET TEE OF THE SEPTIC TANK. THE
FILTER SHOULD BE INSPECTED EVERY SIX MONTHS. THE EFFLUENT FILTER SHALL BE
MAINTAINED AND CLEANED WHEN THE TANK IS PERIODICALLY PUMPED OR AS
NECESSARY. INSTALL A SUITABLE EXTENSION ON THE FILTER WITH A HANDLE TO
BE WITHIN 6" BELOW THE ACCESS LID.
8. THE CONTRACTOR SHALL ENSURE THAT THE SEWER LINES, SEPTIC TANK AND
RISERS ARE WATERTIGHT. ALL PLUMBING FIXTURES AND OWTS COMPONENTS
SHALL BE INSTALLED AND MAINTAINED TO AVOID SURFACE OR GROUNDWATER
FROM ENTERING THE SYSTEM AND TO PREVENT LEAKAGE FROM THE SYSTEM.
IN-HOUSE PLUMBING FIXTURES SHALL BE MAINTAINED TO PREVENT EXCESS
WATER FROM ENTERING THE SEPTIC SYSTEM.
9. THE DIMENSIONS AND NOTES SHOWN ON THE PLAN INDICATE MINIMUM AREA,
LENGTH, WIDTHS AND SEPARATION DISTANCES FOR THE TRENCHES, BED OR
MOUNDED ABSORPTION FIELD.
10. THE ABSORPTION TRENCHES SHALL BE EXCAVATED TO LEVEL GRADE IN NATIVE
EARTH. THE TRENCH BOTTOM AND SIDEWALLS SHALL BE SCARIFIED AND/OR
RACKED IF SMEARING OCCURS. IF EXCESSIVE LARGE COBBLES OR BOULDERS ARE
ENCOUNTERED IN ANY PART OF THE EXCAVATION OVER 6" FROM THE PROPOSED
TRENCH BOTTOM SURFACE, OVER EXCAVATE AND BACKFILL WITH SAND.
11. THE LEACHING CHAMBERS SHALL BE INSTALLED LEVEL WITH A MINIMUM COVER
OF 10 INCHES NOT TO EXCEED 24 INCHES.
12. LEACHING CHAMBERS WILL BE PLACED IN THE EXCAVATION OVER THE NATIVE
SOIL OR SELECT SOIL REPLACEMENT. END CAPS SHALL BE INSTALLED ON THE END
CHAMBERS IN EACH TRENCH.
13. VERTICAL INSPECTION PORTS SHALL BE INSTALLED FROM THE PRE MARKED HOLE
ON THE TOP OF EACH END CHAMBER . (TYP. BOTH ENDS OF EACH ROW) .
14. THE CHAMBERS WILL BE BACKFILLED WITH EXCAVATED MATERIAL VOID OF
ROCKS, THE BACKFILL MATERIAL SHALL NOT EXCEED 2 1/2" DIAMETER AND SHALL
BE PLACED TO AT LEAST 6 INCHES ABOVE THE TOP OF THE CHAMBERS. THE TOP
OF THE PLACED BACKFILL SHALL BE COVERED WITH A LAYER OF FILTER FABRIC. A
MINIMUM 4" DEPTH OF TOPSOIL IS TO BE PLACED ABOVE THE BACKFILL TO THE
SURFACE & RE VEGETATED.
15. INSTALLATION OF LEACHING CHAMBERS SHALL BE IN CONFORMANCE WITH THE
MANUFACTURES INSTALLATION INSTRUCTIONS.
16. THE ABSORPTION TRENCHES/BED OR MOUND MUST BE GENERALLY MARKED AT
THE FOUR CORNERS WITH INSPECTION PORTS AND/OR BURIED REBAR. THE FIELDS
MUST BE PROTECTED FROM VEHICULAR AND LIVESTOCK TRAFFIC.
17. THE ABSORPTION FIELD SURFACES MUST BE SLOPED OR SLIGHTLY MOUNDED TO
DIVERT SURFACE DRAINAGE AWAY FROM THE FIELD.
18. THE ENTIRE ABSORPTION FIELD SURFACE MUST BE RE VEGETATED.
19. THE ABSORPTION FIELD SHALL BE INSTALLED PER THE REQUIRED SETBACK
DISTANCES: 10 feet from any property line.
25 feet from any potable water supply line.
20 feet from any dwelling with basement or crawlspace.
100 feet from any well, spring or cistern.
50 feet from any stream or water course.
1. THE OWTS AS SHOWN ON THE PLAN AND THE DETAILS WERE DESIGNED BY SOPRIS ENGINEERING.
2. THE EXISTING LOT CONDITIONS SHOWN IS BASED ON GIS MAPPING AND LIDAR BY SOPRIS
ENGINEERING.
3. PRIMARY OWNER NAME AND ADDRESS: Thompson, Family Joint Rev Trust
0073 Native Lane
Glenwood Springs CO 81601
4. SITE ADDRESS: 315 Westbank Rd, Glenwood Springs, 81601
5. LEGAL SUMMARY: Section: 2 Township: 7 Range: 89 Subdivision: WESTBANK RANCH SUB. #3
Lot: 1 1.06 ACRES
6. Parcel Number: 39502103001
7. PREVIIOUS ISDS PERMIT # 358, NEW COUNTY OWTS PERMIT #: ____________, ISSUED _________
8. CONTRACTOR: Voskuil Operations
1. ADDITIONAL ASSESSMENTS AND RECOMMENDATIONS WILL BE MADE BY THE ENGINEER
DURING INITIAL STAGES OF CONSTRUCTION TO VERIFY ASSUMPTIONS MADE FOR THE
OWTS DESIGN INCLUDING VERIFICATION OF SOILS, STA LAYOUT, EXCAVATION DEPTHS,
THE LOCATION OF THE SEWER/DISTRIBUTION PIPING, COMPONENTS AND INSTALLATION
OF APPURTENANCES.
2. PRIOR TO CONSTRUCTION OF THE PERMITTED SYSTEM THE ENGINEER SHOULD BE
CONTACTED BY THE PROJECT MANAGER/CONTRACTOR WELL IN ADVANCE TO PROVIDE
ADEQUATE TIME TO DISCUSS THE SYSTEM COMPONENTS WITH THE CONTRACTOR,
ANSWER QUESTIONS, RESOLVE ANY CONFLICT ISSUES AND SCHEDULE INSPECTION SITE
VISITS BASED ON CONSTRUCTION PROGRESS. A PRE-OWTS CONSTRUCTION MEETING
WITH THE ENGINEER AND CONTRACTOR IS ESSENTIAL AND REQUIRED PRIOR TO
INSTALLATION OF THE OWTS COMPONENTS.
3. REGULATIONS REQUIRE THAT THE DESIGN ENGINEERS OF RECORD PERFORM SITE
INSPECTIONS OF THE PERMITTED SYSTEM DURING CONSTRUCTION AND PROVIDE
"AS-CONSTRUCTED" DOCUMENTATION OF THE INSTALLED SYSTEM TO THE THE COUNTY
LPHA AFTER CONSTRUCTION IS COMPLETE. THE ENGINEER SHOULD BE CONTACTED AND
NOTIFIED OF THE CONSTRUCTION SCHEDULE TO PERFORM TIMELY INSPECTIONS,
PROVIDE DIRECTION TO CONTRACTOR REGARDING THE INSTALLATION OF THE OWTS
COMPONENTS AND AT LEAST 48 HOURS PRIOR TO FINAL BACKFILL OF COMPONENTS.
4. THE COUNTY ENVIRONMENTAL HEALTH DEPARTMENT SHOULD BE CONTACTED AT LEAST
48 HOURS PRIOR TO FINAL BACKFILL OF COMPONENTS TO PROVIDE ADVANCED NOTICE
OF CONSTRUCTION SCHEDULE IN ORDER TO PERFORM A FINAL INSPECTION OF THE IN
PLACE COMPONENTS. THE GARFIELD COUNTY ENVIRONMENTAL HEALTH DEPARTMENT
CONTACT NUMBER IS 970-945-6614 X 8106 (MAIN OFFICE).
5. OUR DESIGN AND RECOMMENDATIONS ARE BASED UPON OUR EVALUATION OF THE
EXISTING AND PROPOSED SITE CONDITIONS, THE DEVELOPMENT PLANS AND
INFORMATION SUPPLIED TO US BY OTHERS. IF DEVELOPMENT PLANS OR SITE
CONDITIONS ARE FOUND TO BE DIFFERENT FROM CONDITIONS ASSUMED OR INDICATED,
WE SHOULD BE NOTIFIED TO EVALUATE ANY EFFECT ON THE PROPOSED OWTS.
8. CONTRACTOR SHOULD REVIEW ANY CONDITIONS ON THE ISSUED PERMIT AND
COORDINATE WITH THE ENGINEER REGARDING CONSTRUCTION AND INSPECTIONS OF
THE SYSTEM. IF YOU HAVE ANY QUESTION OR NEED ANY ADDITIONAL INFORMATION AND
TO SCHEDULE INSPECTIONS, PLEASE CALL PAUL RUTLEDGE OR CARTER PAGE, SOPRIS
ENGINEERING, 970 704 0311.
NATIVE, YARD OR LANDSCAPED
SURFACE
COMPACTED SUBGRADE
SUITABLE BACKFILL OR
CLASS 6 ROAD BASE
6" MIN.
4" MIN.
6" MIN.
4"4"
EXCAVATED MATERIAL COMPACTED
TO 90% STANDARD PROCTOR
01-08-25
01-08-25
01-08-25
Design Calculations OWTS
The treatment capacity for the replacement system is designed for a minimum
5-bedroom residence adequate for the existing 4-bedroom single family home that will
provide capacity for additional future usage as needed. It is assumed that in the future
the residence could undergo a major remodel that may include the addition of another
bedroom.
From the Regulation 43 usage table :
Minimum population based on 2 person per bedroom for the first 3 bedrooms = 6
persons and 1 person per bedroom for each additional 2 bedrooms = 2 persons for a
total of 8 persons.
Gallons per day per person =75 gal/person/day, No peaking factor
Max. Design flow (Qd)gallons/day = (# of people) x (avg. flow)gal/person/day.
Design flow Qd = 8*75=600 gpd
Septic Tank Design:
The septic tank capacity for a minimum 48 hour retention time is calculated as follows:
V = 600 gal/day * 2 = 1,200 gallons. Use a 1,500 gallon, 2-compartment reinforced
plastic septic tank with an inlet sanitary tee and effluent filter outlet sanitary tee in the
second chamber in series with a 500 gallon, single-compartment dosing tank with a
bio-tube duplex high head pump dosing assembly. The tank will be installed with a
sealed 30" diameter PVC or plastic access risers and lid set at the finish grade surface.
The existing 1,000 gallon septic tank will be pumped, breached with crushed lid and
backfilled to abandon in place.
Sub Surface Conditions and Testing
A subsurface soil investigation and site assessment was performed by Sopris
Engineering on January 5, 2026. The soils were sampled and characterized by
application of the USDA visual/tactile soil texture method analysis. The soils below 12
inches of topsoil consist of medium dense silt loam soil with less than 1% scattered
gravel or rock content to 7-8 feet below the surface grades. The soils appear to be
consistent across the site from observations in the excavated profile pit and existing
tank/effluent pipe exploratory excavation.
Septic Tank Excavation Pits:
The soils encountered in the existing tank excavation below approximately 12 inches of
topsoil consist of slightly sandy silt loam to the excavation depths of about 7-feet below
the surface grades. No limiting soil or hydrological conditions were encountered. The
slightly dense silt loam texture soil has blocky to granular structure with moderate
grade with no scattered gravel or rock content.. No change of texture was encountered
at depth. No free water was encountered in the pit excavations. No evidence of
seasonal high ground water or redox conditions was observed in the excavation.
PROFILE PIT-PP-1
The soils below approximately 12 inches of topsoil consists of brown silt loam texture
soil with blocky to granular structure of moderate structural grade to a depth of 5 feet
containing no scattered gravel or rock content. The underlying soils to a depth of 8'
consist of friable slightly sandy silt loam with slightly blocky to fine granular structure
of moderate structural grade with no scattered gravel or rock content to the 8' depth
explored. No free water or evidence of seasonal high groundwater was encountered in
the pit excavation.
The native soils sampled from 2'-4' below the surface are characterized as a type 2 with
silt loam texture of moderate grade with blocky granular structure. The tactile soil test
ribbons were ¾ to 1-inch long. The soil type-2 has an effective loading rate (LTAR)of
0.60 gal/s.f./day for a level 1 conventional treatment system. Based on the testing
results, existing topography, vegetation, and observation of site features, the soils are
generally consistent in the 2 soil profile pits. The soils are suitable for the installation of
an STA consisting of multiple pressure dosed gravelless chamber beds.
Additional observations will be performed by Sopris Engineering in the area of the
proposed treatment/absorption field and tank during initial stages of construction prior
to placement of the distribution materials. Sopris Engineering will verify the soil
conditions, OWTS components and provide installation guidance to the contractor. All
findings, conditions and installation documentation will be included in the
As-Constructed plan and report.
Soil Treatment Area/Absorption System Design
The soil treatment area (STA) is designed based on utilizing the effective Long Term
Acceptance Rate (LTAR) for the in-situ soils at the absorptive surface in a chamber bed
system. The STA will utilize pressure dosed distribution laterals to equally pressure
dose each chamber row in each chamber bed.
Long Term Acceptance Rate (LTAR):
Considering the application of the state regulation 43:
Receiving Wastewater Treatment Level 1; Soil type 2 loading rate for a silt loam is (0.6
gal./S.F./day).; Loading factors; (Table 10-2, Gravity application trenches = 1.0 ) and
(Table 10-3, gravelless chambers = 0.7)
A(sf) = Qd x L.F.1 x L.F.2 .: A = Area;
LTAR LTAR = 0.6 Gal/S.F./day for silt loam
Qd = flow (gal/day) = 450 gpd
L.F.1=1.0 Gravity Distribution
L.F.2=0.7 Chambers
A(sf) = 600 gpd x 1.0 x 0.7 = 700 S.F.
0.6 Gal/S.F./day
Number of 5'x3' Bio-Diffuser chambers:
700 S.F = 47 chambers; Use 48 chambers
15 S.F./Chamber
Construct two fully pressure dosed 40.5' by 9' chamber beds. Install 48 ARC-36
chambers in two beds with 3 rows of 8 chambers per row for a total absorption area of
729 S.F. The bottom of each bed to be excavated to an average depth of 30 inches
below the existing surface grades. The absorptive surface to be scarified at level grade.
Chambers to be covered with filter fabric and backfilled to a minimum 3" above
existing perimeter grades.
1.5" SCHD-40 PVC TRANSPORT PIPE
TO DISTRIBUTION MANIFOLD AT HP
VERTICAL 1.5" TEE CONNECTION
G:\2026\36000 315 Westbank\CIVIL\Civil DWGs\DE\36000-DE-OWTS Plan - TCP Rev. 2026-01-15.dwg, 1/15/2026 3:15:25 PM, DWG To PDF.pc3