Loading...
HomeMy WebLinkAboutElevation CertificateU.S. DEPARTMENT OF HOMELAND SECURITY OMB Control No. 1660-0006 Federal Emergency Management Agency Expiration Date: 0613012026 National Flood Insurance Program ELEVATION CERTIFICATE IMPORTANT: MUST FOLLOW THE INSTRUCTIONS ON INSTRUCTION PAGES 1-11 Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. SECTION A- PROPERTY INFORMATION, FOR INSURANCE COMPANY USE Al. Building Owner's Name: JMM IRREVOCABLE TRUST Policy Number: A2. Building SlreetAddress (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.: Company NAIC Number: 30 ST FINNBAR FARM RD, City: CARBONDALE State: CO ZIP Code: 81623 A3. Properly Description (e.g., Lot and Block Numbers or Legal Description) and/or Tax Parcel Number: ST, FINNBAR FARM SUB -DIVISION LOT 7. PARCEL NO. 239131318007 A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.): RESIDETIAL (MAIN RESIDENCE) A5. Latitude/Longitude: Let, 39°24'9.664"N Long.107°9'30.826"W Horiz. Datum: ❑ NAD 1927 ❑x NAD 1983 ❑ WGS 84 A6. Attach at least two and when possible four clear color photographs (one for each side) of the building (see Form pages 7 and 8). AT Building Diagram Number: 2A A8. For a building with a crawlspace or enclosure(s): a) Square footage of crawlspace or enclosure(s): 3480 sq. ft. b) Is there at least one permanent flood opening on two different sides of each enclosed area? ❑ Yes ❑x No ❑ NIA c) Enter number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade: Non -engineered flood openings: 0 Engineered flood openings: 0 d) Total net open area of non -engineered flood openings in A8.c: 0 sq. in. e) Total rated area of engineered flood openings in A8.c (attach documentation — see Instructions): _ 0 sq. ft. f) Sum of A8.d and A8.e rated area (if applicable — see Instructions): 0 sq. ft. A9. For a building with an attached garage: a) Square footage of attached garage: 924 sq. ft. b) Is there at least one permanent flood opening on two different sides of the attached garage? ❑ Yes x❑ No ❑ N/A c) Enter number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade: Non -engineered flood openings: 0 Engineered flood openings: 0 d) Total net open area of non -engineered flood openings in A9.c: 0 sq. in. e) Total rated area of engineered flood openings in A9.c (attach documentation — see Instructions): 0 sq, ft. f) Sum of A9.d and A9.e rated area (if applicable — see Instructions): 0 sq. ft. SECTION 8 - FLOOp INSURANCE RATE MiFIRIVI) INFO RMA f ION B1.a. NFIP Community Name: GARFIELD COUNTY, COLORADO B1.b. NFIP Community Identification Number: 080205 82, County Name:GARFIELD COUNTY B3. State: CO._ B4. Map/Panel No.: 0802051880 85, Suffix: B B6. FIRM Index Dale: 12/15/1977 B7. FIRM Panel Effective/Revised Date: 01/03/1986 B8. Flood Zone(s): B, C B9, Base Flood Elevation(s) (BFE) (Zone AD, use Base Flood Depth): 6254.0 810. Indicate the source of the BFE data or Base Flood Depth entered in Item 139: ❑ FIS 0 FIRM ❑ Community Determined ❑ Other: B11. Indicate elevation datum used for BFE in Item B9: 0 NGVD 1929 ❑ NAVD 1988 ❑ Other/Source: 812. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes 0 No Designation Date: ❑ CBRS ❑ OPA B13. Is the building located seaward of the Limit of Moderate Wave Action (LIMWA)? ❑ Yes X No FEMA Form FF-206-FY-22-152 (formerly 086-0-33) (8/23) Form Page 2 of 8 ELEVATION CERTIFICATE IMPORTANT: MUST FOLLOW THE INSTRUCTIONS ON INSTRUCTION PAGES 1.11 Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.: FOR INSURANCE COMPANY USE 30 ST FINNBAR FARM RD, Policy Number. - City: CARBONDALE State: CO ZIP Code: 81623 Company NAIC Number: SECTION C — BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) C1. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* ❑x Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations - Zones Al-A30, AE, AH, AO, A (with BFE), VE, V1-V30, V (with BFE), AR, AR/A, AR/AE, AR/A1-A30, AR/AH, AR/AD, A99, Complete Items C2.a-h below according to the Building Diagram specified in Item AT In Puerto Rico only, enter meters. Benchmark Utilized: GPS - MESA COUNTY RT VRN Vertical Datum: NAVD 88 Indicate elevation datum used for the elevations in items a) through h) below. X1 NGVD 1929 ❑ NAVD 1988 ❑ Other: Datum used for building elevations must be the same as that used for the BFE. Conversion factor used? x❑ Yes ❑ No If Yes, describe the source of the conversion factor in the Section D Comments area. Check the measurement used: a) Top of bottom floor (including basement, crawlspace, or enclosure floor): 6251.4 x❑ feet ❑ meters b) Top of the next higher floor (see Instructions): 6256.8 x❑ feet ❑ meters c) Bottom of the lowest horizontal structural member (see Instructions): N/A ❑ feet ❑ meters d) Attached garage (top of slab): 6256.7 ❑x feet ❑ meters e) Lowest elevation of Machinery and Equipment (M&E) servicing the building (describe type of M&E and location in Section D Comments area): 6256.7 x❑ feet ❑ meters 0 Lowest Adjacent Grade (LAG) next to building: ❑ Natural ❑X Finished 6256.1 x❑ feet ❑ meters g) Highest Adjacent Grade (HAG) next to building: ❑ Natural x❑ Finished 6256.6 ❑x feet ❑ meters h) Finished LAG at lowest elevation of attached deck or stairs, including structural support: N/A ❑ feet ❑ meters SECTION P ''SURVEX�R, ENC,INEER, OR ARCIiITECT GERIIF1CAfilON" This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by state law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. Were latitude and longitude in Section A provided by a licensed land surveyor? ❑x Yes ❑ No ❑ Check here if attachments and describe in the Comments area. Certifier's Name: MARK S. BECKLER. PLS License Number:28643 Title: SURVEY PRINCIPAL REGysT �PpO Company Name SOPRIS ENGINEERING LLC o�,s' BFC''.�P 502 MAIN ST, SUITE A-3 Address: ro 28643 rr City: CARBONDALE State: CO_ ZIP Code: 81623 T • S" Telephone (970) 704-0311 Exit.: Email: mbeckler@sopriseng.com �pS ........... ' JQ ��NAL LANDS Place a Here -_--2 Date:._�P Signature: JLeva�UL`tificate Copy all pages of thiand ali attachments for (1) community official, (2) insurance agent/company, and (3) building owner. Comments (including source of conversion factor in C2; type of equipment and location per C2.e; and description of any attachments): THE BFE AT THE UPSTREAM BUILDING CORNER = 6254'. THE STRUCTURE'S LOWEST LIVING AREA FF = 6256.8'. THE STRUCTURE IS SITUATED EVENLY IN DESIGNATED ZONE B (57%) & ZONE C (43%) ENTIRELY OUTSIDE THE DESIGNATED FLOODPLAIN. ALL ELEVATIONS SHOWN HERE ARE NGVD29 TO MATCH FIRM 0802051880B. NAVD 88 - NGVD 29 VERTICAL DATUM TRANSFORMATION AT SITE = - 4.482' PER VERTCON. LOWEST SERVICE EQUIPMENT IS AN AC UNIT MOUNTED ON A CONCRETE SLAB ADJACENT TO SUBJECT BUILDING (SEE PHOTO 4) FEMA Form FF-206-FY-22-152 (formerly 086-0-33) (8/23) Form Page 3 of 8 ELEVATION CERTIFICATE IMPORTANT: MUST FOLLOW THE INSTRUCTIONS ON INSTRUCTION PAGES 1-11 BUILDING PHOTOGRAPHS See Instructions for Item A6. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.: FOR INSURANCE COMPANY USE 30 ST FINNBAR FARM RD, __. _------- Policy Number. City: CARBONDALE State: CO ZIP Code: 81623 Company NAIC Number: Instructions: Insert below at least two and when possible four photographs showing each side of the building (for example, may only be able to take front and back pictures of town houses/rowhouses). Identify all photographs with the date taken and "Front View," "Rear View," "Right Side View," or "Left Side View." Photographs must show the foundation. When flood openings are present, include at least one close-up photograph of representative flood openings or vents, as indicated in Sections A8 and A9. Photo One Photo One Caption: EAST FRONT VIEW LOOKING WEST. 01/12/2026 Photo Two Photo Two Caption: SOUTH SIDE VIEW LOOKING NORTH. 01/12/2026 FEMA Form FF-206-FY-22-152 (formerly 086-0-33) (8123) Form Page 7 of 8 ELEVATION CERTIFICATE IMPORTANT: MUST FOLLOW THE INSTRUCTIONS ON INSTRUCTION PAGES 1.11 BUILDING PHOTOGRAPHS M111111111MMIJI Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.: FOR INSURANCE COMPANY USE 30 ST FINNBAR FARM RD, Policy Number. City: CARBONDALE State: CO ZIP Code: 81623 Company NAIC Number: Insert the third and fourth photographs below. Identify all photographs with the date taken and "front View," "Rear View," "Right Side View," or "Left Side View." When flood openings are present, include at least one close-up photograph of representative flood openings or vents, as indicated in Sections AS and A9. Photo Three Photo Three Caption: WEST REAR VIEW LOOKING NORTHEAST. 01/12/2026 Photo Four Photo Four Caption: NORTH SIDE VIEW LOOKING SOUTHEAST. 01/12/2026 FEMA Form FF-206-FY-22-152 (formerly 086-0-33) (8/23) Form Page 8 of 8