HomeMy WebLinkAboutBlower Door TestTesting Company: Name:C5 Energy Inspections Address:209 River Ridge Dr Grand Junction , CO 81503 Phone: 9702503152 www.c5energyinspections.com Technician: Name:Brian Chesney Credentials:BPI Certified ID#5068969 Email:c5energygj@gmail.com Building Information: Project ID:19 Roan creek dr Address:19 Roan Creek Drive Parachute, Colorado 81635 Geo-Tag Data:Latitude: 39.457387 Longitude: -108.029016 Timestamp: 2026-01-12 10:35:09 Customer Information: Name: Address: Measured Leakage:2.38 ACH50 Leakage Target:3.00 ACH50 Compliance with Leakage Target:Pass Test ID:Blower door Purpose of Test:Envelope (IECC) Measured CFM50:965.9 Effective Leakage Area: 53.1 in² Building Volume:24,352.0 ft³Enclosure Surface Area: 0.0 ft² Coefficient (C):76.0 Exponent (n): 0.650 (assumed) Test Standard:RESNET 380 One-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 60 °F Altitude: 5,273.0 ft Outdoor Temp: 19 °F Time Average Period: 10 seconds Test Date and Time:2026-01-28 09:03:00 10% Adjustment Applied: No Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline -3.3 -50.0 -52.5 -49.3 -30.5 1,005.6 Ring A Test Equipment: Flow Device:Model 3 110V Fan Pressure Gauge:DG1000 Serial #: 13229 Calibration Date: 2024-08-27 Deviations from Standard: None Comments: None Envelope Leakage Test Page 2 of 2Report by TEC Auto Test 1.10.2 (3), © 2025 The Energy Conservatory, Inc.