HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLRE-10-25-9537
REBECCA LUCERO
ADU
1000 COUNTY ROAD 252
1) THE APPROVED PLANS ARE TO BE ON -SITE FOR INSPECTIONS.
2) SANITARY FACILITIES ARE REQUIRED TO BE PROVIDED FOR WORKERS.
3) A LIST OF REQUIRED INSPECTIONS WILL BE ATTACHED TO THE PLANS. THE STATE
IS TO PERMIT AND APPROVE THE ELECTRICAL WORK.
HTTPS://VWVW.COLORADO.GOWPACIFIC/DORAIDPO ELECTRICAL PLUMBING PE
RMITS
4) UNDERGROUND UTILITY LOCATES IS THE RESPONSIBILITY OF THE OWNER OR
CONTRACTOR. 811 IS THE COLORADO UTILITY LOCATE HOT LINE.
5) DRAINAGE ACROSS PROPERTY LINES SHALL NOT EXCEED THAT WHICH EXISTED
PRIOR TO GRADING. EXCESS OR CONCENTRATED DRAINAGE SHALL BE
CONTAINED ON SITE OR DIRECTED TO AN APPROVED DRAINAGE FACILITY.
EROSION OF THE GROUND IN THE AREA OF DISCHARGE SHALL BE PREVENTED BY
INSTALLATION OF NON -EROSIVE DOWN DRAINS OR OTHER DEVICES.
6) ALL BACKFLOW PREVENTERS ARE REQUIRED TO BE TESTED AND CERTIFIED BY A
LICENSED BACKFLOW SPECIALIST AFTER INSTALLATION AND PRIOR TO ISSUANCE
OF THE CERTIFICATE OF OCCUPANCY.
7) ELECTRICAL CODE COMPLIANCE WILL BE DETERMINED BASED ON FIELD
INSPECTIONS PERFORMED BY THE STATE ELECTRICAL INSPECTOR, (303) 869-3458.
PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN
DOCUMENTATION OF THE INSPECTIONS.
8) GEOTECHNICAL OBSERVATION IS REQUIRED WHEN THE EXCAVATION IS
COMPLETE AND WRITTEN VERIFICATION BE SUPPLIED AT FOOTING INSPECTION,
1500 PSF.
9) ALL EXTERIOR LIGHTING IS TO BE DOWNCAST AND SHIELDED.
10) SAFETY GLAZING IS NOT DESIGNATED ON THE PLANS. SAFETY GLAZING WILL BE
CHECKED DURING THE FRAMING AND FINAL INSPECTION. (IBC 2406.4)
1 1)A PASSING BLOWER DOOR TEST IS REQUIRED TO BE SUBMITTED PRIOR TO
ISSUING THE CERTIFICATE OF OCCUPANCY.
12)A PROPANE DRAIN WILL BE REQUIRED IF ANY APPLIANCES ARE INSTALLED IN THE
CRAWLSPACE.
13) UFER GROUNDS ARE REQUIRED TO BE INSPECTED AT FOOTING INSPECTION
14)ANY EXPOSED FOAM IS TO BE COVERED WITH AN IGNITION BARRIER OR A
THERMAL BARRIER BASED ON LOCATION. (IRC R316)
15)THE HOME IS TO BE SUPPLIED WITH MECHANICAL VENTILATION OF OUTDOOR
AIR. THE MINIMUM VENTILATION RATE IS TO BE CFM = (0.01X TOTAL SQUARE
FOOTAGE OF THE HOUSE) + 7.5 X (NUMBER OF BEDROOMS +1) GENERAL NOTES
ON THE PLANS INDICATE WHOLE HOUSE VENTILATION.
16) MINIMULLY THE ICE SHIELD IS TO BE INSTALLED AT THE EAVES TO A MINIMUM 241,
UP FROM THE INSULATED WALLS.
17)ALL SHOWER DOORS ARE REQUIRED TO MAINTAIN 22" IN THE CLEAR AND ARE
REQUIRED TO SWING OUT.
18) INSTALL STORMWATER CONTROLS PRIOR TO ANY DIRT WORK.
19) LOCATE ALL UTILITIES PRIOR TO ANY WORK. 811 IS THE STATE UTILITY LOCATE
NUMBER
20) CONTROL NOXIOUS WEEDS. TREAT EXISTING WEEDS PRIOR TO RELOCATING
PLANTS AND SEEDS.
21) REVEGITATE ALL DISTURBED AREAS THAT ARE NOT PART OF A ROAD OR NON -
SEEDED AREA.
22) PROVIDE EROSION CONTROLS UNTIL SEEDED AREAS CAN BE ESTABLISHED.
23) PROVIDE DUST CONTROL AS REQUIRED DURING CONSTRUCTION.
24)THE LOWER BATHROOM MAY NOT ACCOMMODATE THE REQUIRED CLEARANCE
FOR A TOILET AND SHOWER NEXT TO EACH OTHER. VERIFY AT FRAMING
INSPECTION. SEE CUT SHEET ATACHED TO THE PLANS.
25)THE WINDING STAIRS ARE NOT DEPICTED ON THE PLANS CORRECTLY, PLEASE SEE
THE ATTACHED CUT SHEET ON WINDERS. CAUSION THAT THE HEADOUT IN THE
UPPER FLOOR SYSTEM MAY NOT ACCOMMODATE CODE COMPLIANT STAIRS.
VERIFY PRIOR TO FRAMING THE UPPER FLOOR.
26)THE MAIN EXIT DOOR IS TO ACCOMMODATE 32" IN THE CLEAR UTILIZING ONE
LEAF.
27)THE PLUMBING DRAWINGS INDICATE WATER LINES INSTALLED IN EXTERIOR
WALLS WHICH PRESENTS A FREEZE POTENTIAL, RELOACTION REQUIRED AT
PLUMBING ROUGH INSPECTIONS.
28)THE PLANS LACK DETAIL REGARDING INSULATION, THE 2X10 RAFTERS WILL NOT
ACCOMMODATE THE REQUIRED R-49 WITHOUT CLOSED CELL FOAM BEING
UTILIZED.
v
o
ir,
W
cz.
D
CD
iv
00
3"
(n
Q
n
<
(D
O
(D
N.
(D
�
-I
cn
�
Q
—
D
cQ
CD
(D
^
(D
Q
`.
`O
�'
S
co
3
3
�
U-
.�
:,
�
(D
(n
-.
_
O
S
(D
ED
-
(D
O
n
3
w
3
f D
o
(D
:
O
N
O_
D
D(D
o
o
c
m
CD
X
(n
n
CD
O
(D
o
CO
OC
(c
Z
—
N
V
-f
v
(D
v
X
N
r+
v
S
n
v
(DQ
�
-�
n
`�
-I
m
h
OD
03
(D
r+
W
v
(D
D
(D
�
m
(Q
v
�
�
�
°
r r
O
(D
�
(D
<
v_
Ln
Q
c
m
c
v
�
c
(D
v
U)
(D
O
O
S
O
r+
CQ
O D
Z n -!
=n(�n
O D Z
Is
cnO
D m
(n r m
m m 0
u' = O
m m M
X
n>N
m
p
O�c
Z 71 TJ
c m
o
Fri
o�
Z C
� W
mz�
m
a 0
m =
c)
� D �
�70O
A n
m zc
rn C)z
m n
�N=
m
in n
D m
n
mT
-0-i n
U:) D
r- m
m O
OFF/G E ��y