Heat Calcs
Load Short Form Entire House Manual Jay Design Project Information For: Becky Lucero 1000 County Road 252, Rifle, CO 81650 Job: 1001 Grand Ale, Suite 201 Date: Feb 24, 2026 Design Information Htg Clg Infiltration Outside db (°F) -22 81 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TD (°F) 92 6 Fireplaces 0 Daily range - H Inside humidity (%) 50 50 Moisture d'rfference (grAb) 66 -26 HEATING EQUIPMENT Make Mitsubishi Electric Trade Mitsubishi Electric Model MXZ-3D30NLHZ AHRI ref 216505934 Efficiency Heating input Heating output Tern perature rise Actual air flow Air flow factor Static pressure Space thermostat Capacity balance point =14 °F 10 HSPF2 28600 Btuh @ 47°F 34 °F 947 cfrn 0.028 cfmBtuh 0 in H2O COOLING EQUIPMENT Make Mitsubishi Electric Trade Mitsubishi Electric Cond MXZ-3D30NLHZ Col MSZ-GX12NL, MSZ-GX18NL AHRI ref 216505934 Efficiency 11.5 EER2, 20 SEER2 Sensible cooling 19880 Btuh Latent cooling 8520 Btuh Total cooling 28400 Btuh Actual airflow 947 cfm Air flow factor 0.096 cfmBtuh Static pressure 0 in H2O Load sensible heat ratio 1.00 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) Mill) (cfm) 1st Floor 500 24154 8561 676 826 2nd Floor 276 9700 2631 271 254 Entire House 776 33854 9684 947 947 Other equip loads 5019 344 Equip. @ 0.86 RSM 8654 Latent cooling 0 947 TOTALS 776 38872 8654 947 Bdc riOic values have bem ma°uall owndden Calculations approved byACCAto meet all requirements of Manual J 8th Ed. * wrightsoft' 202&Feb-2510:0509 ^, ..._—, .., RigttSlit�Urives�202525000RSU29353 Page1 ACCK ...edgA1001 Grand Ave, Slite 201- Maid J8S rup Calc = MA Frart Doorbaces: N Load Short Form 1st Floor Manual Jay Design Project Information For: Becky Lucero 1000 County Road 252, Rifle, CO 81650 Job: 1001 Grand Ais,Suite201 Date: Feb 24, 2026 Design Information Htg Clg Infiltration Outside db (°F) -22 81 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TD (°F) 92 6 Fireplaces 0 Daily range - H Inside humidity (%) 50 50 Moisture difference (gr/Ib) 66 -26 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperaturerise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg bad Htg AVF Clg AVF (82) (Btuh) (Btuh) (cfm) (cfm) Bath 1 54 3465 819 97 79 Ktchen 202 9762 3760 273 363 Liming Rm 196 6309 2386 176 230 Stair 48 4618 1596 129 154 1stFloor 500 24154 8561 676 826 Other equip bads 0 0 Equip. @ 0.86 RSM 7388 Latent cooling 445 833 676 826 lL:Ai=V? 500 24154 7 edd iftvaluesnavenearmmudiyownddw Calculations approved byACCA to meet all requirements of Manual J 8th Ed. * w`rightsofC 202&Feb2510:0a09 ^A. ... ... RiftSlitebUriversal2025i25Q03RSU29353 Page2 ACCA ...edry11001 oad A e, SUte 201- Mauj J8S.np Calc = MA Fut Dcarfaxs: N Load Short Form 2nd Floor Manual Jay Design Project Informati on Becky Lucero 1000 County Road 252, Rifle, CO 81650 Jab: 1001 Grand Aie, Suite 201 Date: Feb 24, 2026 Design Information Htg Clg Infiltration Outside db (°F) -22 81 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TD (°F) 92 6 Fireplaces 0 Daily range - H Inside humidity (%) 50 50 Moisture difference (grAb) 66 -26 HEATING EQUIPMENT Make n/a Trade n/a Model n/a AHRI ref n/a Efficiency n/a Heating input Heating output 0 Btuh Temperaturerise 0 °F Actual air flow 0 cfm Air flow factor 0 cfrnBtuh Static pressure 0 in H2O Space thermostat n/a COOLING EQUIPMENT Make n/a Trade n/a Cond n/a Coil n/a AHRI ref n/a Efficiency n/a Sensible cooling 0 Btuh Latent cooling 0 Btuh Total cooling 0 Btuh Actual airflow 0 cFm Air flow factor 0 cfmBtuh Static pressure 0 in H2O Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF CIgAVF (ft2) (Btuh) (Btuh) (cfm) (cFm) Bath 2 80 3307 354 93 34 Bedroom 1 172 5507 2228 154 215 Closet 24 886 49 25 5 2nd Floor 276 9700 2631 271 254 Other equip loads 0 0 Equip. @ 0.86 RSM 2271 Latent cooling 0 1 lJ IrtiO v. vv BddWoc values have been nmudlyowndden Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrightsoft" 2026-Feb-2510:05:09 Rift- i te@Urivesal 2725250.03RSLJM353 P8ge3 XCA ...ad01001 Grand /be, S1ite 201- Meual J&I rW Calc = MJ8 Frond Docrfaces: N Building Analysis Entire House Manual Jay Design Project For: Becky Lucero 1000 County Road 252, Rifle, CO 81650 Job: 1001 Grand Am, Suite201 Date: Feb24,2026 Design • • • Location: Indoor: Heating Cooling Rifle Garfield CountyAP, CO, US Indoor temperature (°F) 70 75 Elevation: 5522 ft Design TD ('F) 92 6 Latitude: 40°N Relative humidity (% 50 50 Outdoor Heatin Cooling Moisture dflference �grAb) 65.7 -26.5 Dry bulb (T -2T 81 Infiltration: Daily range°F) - 34 ( H ) Method Simplified Wet bulb (* )- 58 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Heating 1 Component Btuh/ft' Btuh % of load Walls 7.9 11520 29.6 Glazing 43.2 7091 18.2 Doors 0 0 0 Ceilings 1.7 828 2.1 Floors 16A 8189 21.1 Infiltration 3.8 6226 16.0 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 5019 12.9 Adjustments 0 Total 38872 100.0 Cooling Component Btuh/ft2 Btuh %of load Walls 0.3 495 4.9 Glazing 33.0 5405 53.9 Doors 0 0 0 Ceilings 0.6 310 3.1 Floors 0 0 0 Infiltration 0.1 224 2.2 Ducts 0 0 Ventilation 344 3.4 Internal gains 3250 32.4 Blower 0 0 Adjustments 0 Total 10027 100.0 Latent Cooling Load = 0 Btuh Overall U-value = 0.115 Btuh/t2--°F, Wndow /FloorArea = 21.1 % Data entries checked. Glazing BoldMic values havebeen manualyovemddei Ceilings Ventilation Infiltration Ceilings Gains wrightsoft" 2026-Feb-2510r.0509 Ric#t-%t&UriverA202'MOM RSU29353 Pagel /9ZZA: ...wk)A1001 acid xe, Sufe 291- MmA J8S nip Cale = MJS Rat Darfaees: N Building Analysis 1st Floor Manual Jay Design Project Information For: Becky Lucero 1000 County Road 252, Rifle, CO 81650 Job: 1001 Grand AR, Suite 201 Date: Feb24,2026 By Design • • • Location: Indoor: Heating Cooling Rifle Garfield CountyAP, CO, US Indoor temperature (7) 70 75 Elevation: 5522 ft Design TD CF) 92 6 Latitude: 40'N Relative hum&y {°In 50 50 Outdoor. Heatin Cooling Moisture dfiference (grAb) 65.7 -26.5 Dry bulb (T) '2 81 Infiltration: Daily range ('F) - 34 (H ) Method Simplified Wet bulb (°F) - 58 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Heating Component Btuh/ftZ Btuh % of load Walls 7.9 6947 28.8 Glazing 43.2 4843 20.1 Doors 0 0 0 Ceilings 1.7 371 1.5 Floors 16.4 8189 33.9 Infiltration 3.8 3805 15.8 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 24154 100.0 Cooling Component Btuh/ft2 Btuh % of load Walls 0.3 298 3.5 Glazing 44.4 4968 58.0 Doors 0 0 0 Ceilings 0.6 139 1.6 Floors 0 0 0 Infiltration 0.1 137 1.6 Ducts 0 0 Ventilation 0 0 Internal gains 3020 35.3 Blower 0 0 Adjustments 0 Total 8561 100.0 Latent Cooling Load =445 Btuh Overall U-value = 0.129 Btuh/ftz-°F, Window / FloorArea = 22.4 % Data entries checked. VvalIS Glazin Other Walls Internal Gains Glazing Other eotdridlc values have been manualyoverridden _ `rld- wrigF�tsoft� 2026-Feb2510:05.09 RiOSLA& Uriversal 202525 Q0o RSU293M Nge 2 ACCK ...edryAlool Craad Ave, Site 201- Manual JBS.rup C.alc = MJ8 Frat Doorfaces: N Building Analysis 2nd Floor Manual Jay Design Project Information For: Becky LUcero 1000 County Road 252, Rifle, CO 81650 Job: 1001 Grand Am, Suite 201 Date: Feb 24, 2026 By Design C• • • Location: Indoor: Heating Cooling Rifle Garfield CountyAP, CO, US Indoor temperature (°F) 70 75 Elevation: 5522 ft Design TD IF 92 6 Latitude: 40°N Relative humlldlty(% 50 50 Outdoor Heatin Cooling Moisture dfference grAb) 65.7 -26.5 Dry bulb (°F) -2 81 Infiltration: Daily range (`F) - 34 ( H ) Method Simplified Wet bulb (OF) - 58 Construction qual' t Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Heating Component Btuh/ftZ Btuh % of load Walls 7.9 4573 47.1 Glazing 43.2 2248 23.2 Doors 0 0 0 Ceilings 1.7 457 4.7 Floors 0 0 0 Infiltration 3.8 2421 25.0 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 9700 100.0 Cooling Component Btuh/ft' Btuh j % of load Walls 0.3 196 7.5 Glazing 37.4 1947 74.0 Doors 0 0 0 Ceilings 0.6 171 6.5 Floors 0 0 0 Infiltration 0.1 87 3.3 Ducts 0 0 Ventilation 0 0 Internal gains 230 8.7 Blower 0 0 Adjustments 0 Total 2631 100.0 Latent Coo Iirig Load = 0 Btuh Overall U-value = 0.087 Btuh/ft2--°F, Window / FloorArea =18.8 % Data entries checked. Walls.. Bddrdalic values hambeen manualyovwxkkn uracury Walls Internal Gains j Infiltration Ceilings Glazing wrightsoft� 2026Feb-2510:0509 RicjiSlite@Uriversal202525A03RSU293M Pay ...ed,)A1001 trail /4e, Site 201- MaxA A&rrp Cric = MJ8 Fraf Doariacm: N Project Summary Entire House Manual Jay Design Project Information For: Becky Lucero 1000 County Road 252, Rifle, CO 81650 Notes: Job: 1001 Grand Am, Suite 201 Date: Feb 24, 2026 1. Design Information ..I Weather: Rifle Garfield CountyAP, CO, US Winter Design Conditions Summer Design Conditions Outside db -22 °F Outside db 81 °F Inside db 70 °F Inside db 75 °F Design TD 92 -F Design TD 6 °F Daily range H Relative humidity 50 % Ventilation Method ASHRAE 62.2-2019 Moisture d'€fference -26 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 33854 Btuh Structure 9684 Btuh Ducts 0 Btuh Duds 0 Btuh Central vent (61 cfm) 5019 Btuh Central vent (61 cfm) 344 Btuh Outside air Outside air Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment bad 38872 Btuh Use manufacturer's data n Ratelswing multiplier 0.86 Infiltration Equipment sensible load 8654 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 419 Btuh Duds 0 Btuh Central vent (61 cfm) -893 Btuh Heating Cooling Outside air 0 Btuh Area (ff) 776 776 Equipment latent load I/alume (f) 7416 7416 Airchangeslhour 0.61 0.32 Equipment T❑tal Load (Serr+Lat) 8654 Btuh Equiv.AVF (cfm) 75 40 Req. total capacit}o at 0.70 SHR 1.0 ton Heating Equipment Summary Cooling Equipment Summary Make Mitsubishi Electric Make Mitsubishi Electric Trade Mitsubishi Electric Trade Mitsubishi Electric Model MXZ-3D30NLHZ Cond MXZ-3D30NLHZ AHRI ref 216505934 Coil MSZ-GX12NL, MSZ-GX18NL AHRI ref 216505934 Efficiency 10 HSPF2 Efficiency 11.5 EER2, 20 SEER2 Heating input Sensible cooling 19880 Btuh Heating output 28600 Btuh @ 47°F Latent cooling 8520 Btuh Temperaturerise 34 °F Total cooling 28400 Btuh Actual air fbw 947 cfm Actual air flow 947 cfm Air flow factor 0.028 cfm/Btuh Air flow factor 0.096 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 1.00 Capacity balance point =14 °F 9o1&?&1cv&ueshawbemmanudyow ddw Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -PkwrightsoTt 2026Feb-25 T05:10 A=-. R gti-9 ite® Urivasd 202525.aO3 RSU293M Page 1 ACCA...ecW1001QadAte,Sute201-MaidJ8Snq Cric=MJ8 FiatDoorftm: N Project Summary 1st Floor Manual Jay Design Project Inforitnatian For: Becky Lucero 1000 County Road 252, Rifle, CO 81650 Notes: Design Information Weather: Rifle Garfield CountyAP, CO, US Job: 1001 Grand Am, Suite201 Date: Feb 24, 2026 Winter Design Conditions Summer Design Conditions Outside db -22 °F Outside db 81 °F Inside db 70 °F Inside db 75 °F Design TD 92 °F 0 bran D H °F Relative humidity 50 % Ventilation Method Moisture difference -26 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 24154 Btuh Structure 8561 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (39 cfm) 0 Btuh Central vent (39 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24154 Btuh Use manufacturer's data n Ratelswing multiplier 0.86 Infiltration Equipment sensible load 7388 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 445 Btuh 0 Btuh Central vent (39 cfm) 0 Btuh Heating Cooling 445 Btuh Area (fit) 500 500 Equipment latent load Volume (ft3) 4932 4932 Air changes/hour 0.56 0.29 Equipment Total Load (Sen+Lat) 7833 Btuh Equiv.AVF (cfm) 46 24 Req. total capacity at 0.70 SHR 0.9 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 of Total cooling 0 Btuh Actualairflow 0 Cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Spaoe thermostat n/a Load sensible heat ratio 0 ftWl lic values bambeen manualyoveniddm Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrIa tts.i t' 2025Feb25 T05:10 _ Rind-SitaUrivesai272a25.0.00RSU2M Paget ACCA ...edry\1001 Qad Pve, Sute 201- Maid AS np Calc = MJ8 Frort Doafaces: N Project Summary 2nd Floor Manual Jay Design Pro'ed , Information For: Becky Lucero 1000 County Road 252, Rifle, CO 81650 Notes: Design Information Weather: Rifle Garfield County AP, CO, US Job: 1001 Grand Am, Suite 201 Date: Feb24,2026 W. Winter Design Conditions Summer Design Conditions Outside db -22 °F Outside db 81 °F Inside db 70 °F Inside db 75 °F Design TD 92 °F Design TD 6 °F Daffy range H Relative humidity 50 % Ventilation Method Moisture difference -26 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 9700 Btuh Structure 2631 Btuh Ducts 0 Btuh Duds 0 Btuh Central vent (22 cfm) 0 Btuh Central vent (22 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment bad 9700 Btuh Use manufacturers data n Ratelswing multiplier 0.86 Infiltration Equipment sensible load 2271 Btuh Method Simprified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure -26 Btuh Duds 0 Btuh Central vent (22 cfm) 0 Btuh Heating Cooling 0 Btuh Area (ftx) 276 276 Equipment latent load Volume (fP) 2484 2484 AirchangeMiour 0.71 0.37 Equipment Total Load (Sen+Lat) 2271 Btuh Equiv.AVF (dm) 29 15 Req. total capac4 at 0.70 SHR 0.3 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible coaling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total coaling 0 Btuh Actual airflow 0 cfm Actual airflow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ed&% is dues hambew mawalyowndden Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsnit 2026-Feb-251Q.0510 . R gtt- ite®UrivesA 2M5 25.0.03 RSU29363 Page 3 ACCA ...edry\1001 Gad Pie, Site 201- Maid A&rup Cdc = MJ8 Flom Doorfacm: N Right-M Worksheet Job: 1001 Grand Am, Suite201 Endrle House Date: Feb24,2026 Manual Jay Design 1 f Room name Entire House 1st Roor 2 3 Exposed wall Room height 160.0 ft 9.6 ft 90.0 ft 9.9 ft 4 Room dimensions 5 Room area 776.0 ft 500.0 ft' Ty Construction number tivalue (Btuhll8--°F) Or HTM (BluhRl2) Area OF) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (BWh) Heat Cool Gross W/S Heat Cool Gross NrP/S Heat Cool 6 11 yJ L—C 12D-Osw 4A3-2ov 12D-09w 4A3-2ov 4A3-2ov 12D-Osw 4A3-2ov 1613-56ad 22A-Rol 0.086 0.470 0.086 0.470 0.086 0.470 0.086 0.470 0.018 0.989 n n a e s s w w 7.91 43.24 7.91 43.24 7.91 4324 7.91 4324 1.66 90.99 0.34 10.91 0.34 41.68 0.34 19.57 0.34 41.68 0.62 0.00 360 12 450 56 360 48 450 48 500 500 348 0 394 0 312 0 402 0 500 90 2753 519 3117 2421 2469 2076 3181 2076 828 8189 118 131 134 2334 106 939 137 2001 310 0 234 0 225 40 234 24 297 48 224 500 234 0 185 0 210 0 249 0 224 90 1851 0 1464 1730 1662 1038 1970 2076 371 8189 79 0 63 1667 71 470 85 2001 139 0 V�1 L—G V"12D-Osw yJ —G C F 6 c)AEDe)cursion 0 830 Envelope lossIgain 27628 6210 20349 5405 12 a) Infiltration b) Room ventilation 6226 0 224 0 3805 0 137 0 13 Internal gains: Occupants @ 230 Appliancestother 5 1150 1 2100 4 920 1 2100 Subtotal (lines 6 to 13) 33854 9684 24154 8561 14 15 Less e)demal load Less transfer Redistribution Subtotal Ductloads 1 0% 0% 0 0 0 33854 0 0 0 0 9684 0 0% 0% 0 0 0 24154 0 0 0 0 8561 0 Total room load Air required (clm) I 1 33854 1947 9684 947 1 24154 676 8561 826 Calculations approved b ACCAto meet all requirements of Manual J 8th Ed. _ + wrigF�tsoft^ 2025F�2510:05:10 �� Righ[SlilBhJ Urives� 202.`i25000 RSU29063 Page 1 edry\1001 Gard Are, Siite 201- MarLd JBS.rup Cale = MJ8 Front Doorfaces: N Right-l® Worksheet Job: 1001 Grand A&-, Suite 201 Entire House Date: Feb24,2026 I� Manual Jay Design 1 Room name 2nd Floor 2 Exposed wall 70.0 ft 3 Room height 9.0 it 4 Room dimensions 5 Room area 276.0 R2 Ty Construction number U-value (Bhihtff--°F) Or HTM (BWhRtz) Area O) or perimeter (ft) Load (Btuh) I Area or perimeter Load Heat Cool Gross IWP/S Heat Cool Gross W/S Heat Cool 6 V�/ 12D-0sw 0.086 n 7.91 0.34 126 114 902 39 I� 4A3-2ov 12D-0sw 4A3-2ov 0.470 0.086 0.470 n a e 4324 7.91 43.24 10.91 0.34 41.68 12 225 16 0 209 0 519 1654 692 131 71 667 t—G V1/ �G 11 12D•0sw 4A3-2ov 12D-0sw 0.086 0.470 0.086 s s w 7.91 43.24 7.91 0.34 19.57 0.34 126 24 153 102 0 153 807 1038 1211 35 470 52 tV)/ 4A32ov 16B-56ad 0.470 0.018 w 43.24 1.66 41.68 0.62 0 276 0 276 0 457 0 171 —G c F 22A-1pl 0.989 90.99 0.00 0 0 0 0 6 c)AEDexursion 679 Envelope loss(gain 7279 2314 12 a) Infiltration b) Room venfilation 2421 0 87 0 13 Internal gains: Occupants @ 230 1 230 Applianceslother 0 Subtotal (lines 6 to 13) 9700 2631 Less external load 0 0 Less transfer 0 0 Redistibuton 0 0 14 15 Subtotal Dudloads 1 0% 0% 9700 0 2631 0 Total room load I 9700 1 2631 Air required (dm) I 271 254 Calculations approved b ACCAto meet all requirements of Manual J 8th Ed. _ -rFF wrigytsvfY^ 2026-Fd}2510:05:10 -••• Right-RA&Univa--J2 52FM0�3PMZ3M Page2 a*)y iooi o d A e, Site 2M - Maud J8S nip Cdc = MJ8 Fart Docrfsces IV Mght-J@ Worksheet Job: 1001 Grand Ate, Suite201 1st Floor Date: Feb24,2026 Manual Jay Design 1 Room name 1 st Floor Bath 1 2 3 4 5 Eposed wall Room height Room dimensions Room area 90.0 ft 9.9 ft 500.0 ft2 15.0 ft 9.0 It heaVcool 6.0 x 9.0 ft 54.0 ft2 Ty on r Uvalue (Btuh/ --°F) Or HTM (BtuhRtz) Area (f) or perimeter (ft) Load (Btiah) Area (ft) or perimeter (ft) Load (Bfuh) Heat Cool Gross NP/S Heat Cool Gross N/P/S Heat I Cool 6 11 V"1260sw 4A3-2ov 12D-0sw 4A3-2ov 1260sw 4A3-2ov 12QOsw 4A3-2ov 1613-56ad 22A-tpl 0.086 0.470 0.086 0.470 0.086 0.470 0.086 0.470 0.018 0.989 n n a e s s w w - 7.91 0.00 7.91 43.24 7.91 4324 7.91 43.24 1.66 90.99 0.34 0.00 0.34 41.68 0.34 19.57 0.34 41.68 0.62 0.00 234 0 225 40 234 24 297 48 224 500 234 0 185 0 210 0 249 0 224 90 1851 0 1464 1730 1662 1038 1970 2076 371 8189 79 0 63 1667 71 470 85 2001 139 0 54 0 0 0 0 0 81 12 54 54 54 0 0 0 0 0 69 0 54 15 427 0 0 0 0 0 546 519 89 1365 18 0 0 0 0 0 23 500 33 0 yJ t—G V11 �G V)/ I—; C F 6 c)AEDexursion 8301 1225 Envelopelos/gain 1 20349 5405 2946 800 12 a) Infiltration b) Room ventilation 3805 0 137 0 519 0 19 0 13 Internal gains: Occupants@ 230 Appliancestother 4 920 2100 0 0 0 Subtotal (lines 6 to 13) 24154 8561 3465 819 14 15I� Less extemalload Lesstransfer Redistribution Subtotal Ductloads 0% 0%1 0 0 0 24154 0 0 0 0 8561 0 -0% 0% 0 0 0 3465 0 0 0 0 819 0 ` Total room load Air required (clm) 24154 676 8561 826 3465 97 819 79 Calculations approved b ACCA to meet all requirements of Manual J 8th Ed. -rl.t- wr7gF�Cso[-e- 2025Fd)-2510:0M Righ S itc@ unvasa 20 525.0.03 RSU29053 P8W 3 ..e*y11001 Gard Are, Site 201- Maud J8S r p Calc = MJ8 Fora Doorfaces: N Ftlght-J® Worksheet Job: 1001 Grand Nue,Suite 201 1sfF/oor date: Feb24,2026 Manual Jay Design 1 2 3 4 Room name Exposed wall Room height Room dimensions Kitchen 39.0 ft 9.0 ft heaV000l 1.0 x 202.0 ft Living Fan 28.0 ft 9.0 It heat/cool 14.0 x 14.0 ft 5 Room area 202.0 ft' 196.0 ft' Ty Conshvdion number tivalue (Btuh/ft'--'F) Or HTM (Btuh/ff) Area (ft) or perimeter (ft) Load (Btuh) Area (ft) or perimeter (ft) Load (Bhih) Heat Cool Gross NP/S Heat Cod Gross I NIPS Heat Cool 6 11 V+/ C 12D-0sw 4A3-2ov 12D-0sw 4A3-2ov 12D-0sw 4A3-2ov 1213-0sw 4A3-2ov 1613-56ad 22A-tol 0.086 0.470 0.086 0.470 0.086 0.470 0.086 0.470 0.018 0.989 n n a a s s w w 7.91 0.00 7-91 43.24 7.91 43.24 7.91 43.24 1.66 90.99 0.34 0.00 0.34 41.68 0.34 19.57 0.34 41.68 0.62 000 0 0 99 20 180 24 72 12 66 202 0 0 79 0 156 0 60 0 66 39 0 0 625 865 1234 1038 475 519 109 3549 0 0 27 834 53 470 20 500 41 0 126 0 126 20 0 0 0 0 56 196 126 0 106 0 0 0 0 0 56 28 997 0 839 865 0 0 0 0 93 2548 43 0 36 834 0 0 0 0 35 0 VI! L—1 VN L —G t—G C F 6 c)AEDe)cursion 107 44 Envelope loss/gain 1 8413 2052 5341 991 12 a) Infiltration b) Room ventilation 1349 1 0 48 0 968 0 35 0 13 Internal gains: Occupants@ 230 Appliancestother 2 460 1200 2 460 900 Subtotal (lines 6 to 13) 9762 3760 6309 2386 14 15 Less external load Lesstransrer Redistribution Subtotal Duct loads -0% 0% 0 0 0 9762 0 0 0 0 3760 0 -0% 0% 0 0 0 6309 0 0 0 0 2386 0 Total room load Air required (dm) 1 9762 1 273 3760 363 6309 176 2386 230 Calculations approved b ACCA to meet all requirements of Manual J 8th Ed. _ wrlcylmrsvft- 2025-Feb-251005:10 R ght-s iteo universal 20252sam RSu2.m Page ACCK -.edgA1o01GadAre,Stite201-MwWJBsS.np Calc=MJB FrondDoorfaces: N Right-J® Worksheet Job: 1001 Grand Am, Sub201 1st Floor Date: Feb24,2026 Manual Jay Design 1 Room name Stair 2 Exposed wall 8.0 ft 3 Room height 180 ft heaftol 4 Room dimensions 6.0 x 8 0 ft 5 Room area 48.0 ft2 Ty Construction number U-value (Btuhflt--°F) Or HTM (BtuhM) Area (ft) or perimeter (ft) Load (Btuh) Area or perimeter Load Heat Cool Gross NP/S Heat Cool Gross N/P/S Heat Cool 6 Vr12D-Osw 0.086 n 7.91 0.34 54 54 427 18 4A3-2ov 12D-Osw 4A3-2ov 0.470 0.086 0.470 n a e 0.00 7.91 43.24 0.00 0.34 41.68 0 0 0 0 0 0 0 0 0 0 0 0 —� y/ —G VL—G 11 1213-0sw 4A3-2ov 12D-Osw 0.086 0.470 0.086 s s w 7.91 43.24 7.91 0.34 19.57 0.34 54 0 144 54 0 120 427 0 949 18 0 41 L—� 4A3-2ov 1613-56ad 0.470 0.018 w 43.24 1.66 41.68 0.62 24 48 0 48 1038 79 1000 30 C F 22A-tpl 0.989 90.99 0.00 48 8 728 0 6 c)AEDexursion 454 Envelope loss/gain 3649 1561 12 a) Infiltration b) Room ventilation 968 0 35 0 13 Internal gains: Occupants @ 230 0 0 Applianoes/other 0 Subtotal (lines 6 to 13) 4618 1596 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 4618 1596 15 Ductloads -0% 0% 0 0 Total room load 4618 1596 Air required (clm) 1129 154 Calculations approved b ACCA to meet all requirements of Manual J 8th Ed. _ f wriglr.Lsaft' 2025Fetr251005:10 Right—EW.V Urivesd 2m5 25am RSU29353 Paga 5 ACCK ..edoA1001 Grad Ate, Site 201- Masud J83.np Cdc = MJ8 Front Docrfwm: N Right-M Worksheet Job: 1001 Grand Aue,Suite 201 2nd Floor Date: Feb24,2026 Manual Jay Design 1 Room name 2nd Floor Bath 2 2 3 4 Exposed wall Room height Room dimensions 70.0 ft 9.0 it 26.0 ft 9.0 ft heatlaool 10.0 x 8.0 ft 5 Room area 276.0 ft 80.0 W Ty Construction number LWalue (BtuhHF--°F) Or HTM (BtuhAF) Area OF) or perimeter (ft) Load (Bhih) Area (T) or perimeter (ft) Load (Btuh) Heat Cool I Gross WP/S Heat Cool Gross WPIS Heat Cool 6 11 V)/ �C 12D-Osw 4A3-2ov 4A3-2ov 12D•Osw 4A3-2ov 12D-Osnr 4A3-2ov 16B-56ad 22A-tpl 0.086 0.470 0.086 0.470 0.086 0.470 0.086 0.470 0.018 0.989 n n a a s s w w 7.91 4324 7.91 43.24 7.91 43.24 7.91 0.00 1.66 0.00 0.34 10.91 0.34 41.68 0.34 19.57 0.34 0.00 0.62 0.00 126 12 225 16 126 24 153 0 276 0 114 0 209 0 102 0 153 0 276 0 902 519 1654 692 807 1038 1211 0 457 0 39 131 71 667 35 470 52 0 171 0 90 12 72 0 0 0 72 0 80 0 78 0 72 0 0 0 72 0 80 0 617 519 570 0 0 0 570 0 132 0 26 131 24 0 0 0 24 0 50 0 VI/ L-G --12D-Osw VV L—G V)/ C F 6 c)AEDe:cursion 679 66 Envelope lossigain 7279 2314 2408 322 12 a) Infiltration b) Room ventilation 2421 0 87 0 899 0 32 0 13 Internal gains: Occupants @ 230 Appliancedother 1 230 0 0 0 0 Subtotal (lines 6 to 13) 9700 2631 3307 354 Less extemalload Lesstransfer Redistribution 0 0 0 0 0 0 0 0 0 0 0 0 14 15 Subtotal Dudloads 0% 0% 9700 0 2631 0 -0% 0% 3307 0 354 0 Total room load Air required (dm) 9700 271 2631 254 3307 93 354 34 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. _ +* wrigF,tsoft 202EF�2519.0510 AC RightSlite Udvesd 3TL5i 250.03 RSU2 iFi3 Page 6 _ecky�1001Gr"AreWte201-MarWAS. Csic=MJ8 Front Deafaxs:N Right-M Worksheet Job: 1001 Grand Am, Suite201 2nd Floor Date: Feb 24, 2026 Manual Jay Design 1 Room name Bedroom 1 aoset 2 3 4 Exposed wall Room height Room dimensions 36.0 ft 9.0 It heaVocd 1.0 x 172.0 ft 8.0 ft 9.0 It heat/eool 3.0 x 8.0 ft 5 Room area 172.0 fF 24.0 ft' Ty Construction number Uvalue (Btuh/It--°F) Or HTM (BWh/W) Area (16) or perimeter (ft) Load (Bhih) Area (T) or perimeter (ft) Load (Btuh) Heat Cool Gross NP/S Heat Cool Gross NP/S Heat Cool 6 11 VJJ L—G 1260su 4A32ov 12QOsw 4A3-2ov 12D-Osw 4A3-2ov 12a0sw 4A3-2ov 16&56ad 0.086 0.470 0.086 0.470 0.086 0.470 0.086 0.470 0.018 n n a e s s w w 7.91 4324 7.91 43.24 7.91 4324 791 0.00 1.66 0.34 10.91 0.34 41.68 0.34 19.57 0.34 0.00 0.62 36 0 81 16 126 24 81 0 172 36 0 65 0 102 0 81 0 172 285 0 514 692 807 1038 641 0 285 12 0 22 667 35 470 28 0 107 0 0 72 0 0 0 0 0 24 0 0 72 0 0 0 0 0 24 0 0 570 0 0 0 0 0 40 0 0 24 0 0 0 0 0 15 VI/ —G y/ L—G V�/ —G C F 22A-tpl 0.989 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AEDe)cursion 614 1. 0 Envelope losstgain 4261 1954 609 39 12 a) Infiltration b) Room ventilation 1245 ❑ 45 0 277 0 10 0 13 Internal gains: Occupants @ 230 Applianoestother 1 230 ❑ 0 0 0 Subtotal (lines 6to13) 5507 2228 886 49 Less external load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 15 Subtotal Duct loads I 0% 0% 5507 0 2228 0 -0% 0% 886 0 49 0 Total room load 5507 2228 886 49 Air required (dm) 154 215 25 5 CaWlatfons approved b ACCAto meet all requirements of Manual J 8th Ed. -'{f wrightsaft' 2026Feb2510:05:10 RigtdSlite@ Urivasal 2m525.ao3 RSU29353 page 7 ACCK edgAlOD1 Gad Ate, SUte 201- Ma real JBS ny Cslc = MJ8 Fiat Docrfacm: N Bath 1 Stair Job #: 1001 Grand Ave, Suite 201 Performed for: Becky Lucero 1000 County Road 252 Rifle, CO 61650 First Floor Living Rm Kitchen Manual Jay Design Scale: 1 : 38 Page 1 Right -Suite® Universal 2025 25.0.03 RSU29353 2026-Feb-25 10:06:01 Ave, Suite 201 - Manual J&S.rup Job #: 1001 Grand Ave, Suite 201 Performed for: Becky Lucero 1000 County Road 252 Rifle, CO 81650 Second Floor Manual Jay Design Scale: 1 : 38 Page 2 Right -Suite® Universal 2025 25.0.03 RSU29353 2026-Feb-25 10:06:01 ... Ave, Suite 201 - Manual J&S.rup Manual S Compliance Report Job: 1001 Grand Ate, Suite201 p p Date: Feb 24, 2026 Entire House By. Manual Jay Design Project Information For: Becky Lucero 1000 County Road 252, Rifle, CO 81650 Cooling Equipment Design Conditions Outdoor design DB: 81.3°F Sensible gain: 10027 Btuh Entering coil DB: 75.4°F Outdoor design WB: 58.4°F Latent gain: 0 Btuh Entering coil WB: 61.4°F Indoor design DB: 75.0°F Total gain: 10027 Btuh Indoor RH: 50% Estimated airflow: 947 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Mitsubishi Electric Model: MXZ-3D30NLHZ+MSZ-GX12NL, MSZ-GX18NL Actual airflow: 947 cfm Sensible capacity: 19880 Btuh 198% of load Latent capacity: 8520 Btuh 0% of bad Total capacity. 28400 Btuh 283%ofload SHR: 70% Heating Equipment Design Conditions Outdoor design DB: -22' F Heat loss: 38872 Btuh Indoor design DB: 70.0'F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Mitsubishi Electric Actual airflow: 947 cfm Output capacity: 28600 Btuh Supplemental heat required: 10272 Meets all requirements ofACCA Manual S. Entering coil DB: 64.0°F Model: MXZ-3D30NLHZ+MSZ-GX12NL, MSZ-GX18NL 74% of bad Btuh Capacity balance: 14 °F Economic balance: -99 °F 2026-F�251Q05:10 wrigiitsaft' RiftSlit&Urivesd272i2riaWRSLJ29353 Page ACCA...,*1001Gard/ve,Site201-MamdJSSrW Calc=MJ8 FutDoorfaces: N