Loading...
HomeMy WebLinkAboutDeferred InspectionsCOLORADO tDepartment of Local Affairs Division of Housing Building Department Representitive Printed Nam Building Department Representitive JULY 2023 Date 3-4 - 4 i�r � i5L ttr 6`1 - 25 - q'5'6� Accept Defer Inspection Contact email: -fraA4KD t 4M-*U'7YCa, ` Gov If applicable: Fire Safety Official Printed Fire Safety Official Signature Date Contact email: Is a fire protection system required? (check one) Required Not Required If required, the inspection is to be performed by (check one): Fire Department: (MAME) OR Colorado Division of Fire Prevention Et Control Manufacturer's Authorized Quality Assurance Representative Printed Name Amanda Johanneck Manufacturer's Authorized Quality Assurance Representative Signaturc,.'R� Date 8/12/2025 Contact email: amanda.9ohanneck@northstarsb.com If the inspection has been deferred and the manufacturer elects to utilize an Approved Third Party Agency to inspect the "OC" items on behalf of DOH, please sign and date below. Approved Third Party Agent Printed Name Approved Third Party Agent Signature Contact Governor Jared 5. Polis I Rick M_ Garcia, Executive Director I Alison George, Division Director 1313 Sherman St., Room 320, Denver, CO 80203 P 303.864.7810 F 303.864.7857 TDD/TTY 303.864.7758 www.dola.coiorado.gov a•r Strengthening Colorado Communities QQLA COLORADO Department of Local Affairs Division of Housing Verify Inspection(s) Completed JULY 2023 Once you have completed all of your assigned inspections identified in this form and they have passed for compliance, please sign and date below. Building Department Representitive Printed Name. Building Department Representitive Signature. Date Contact email Or Approved Third Party Agent Printed Name Approved Third Party Agent Signature Contact email: Fire Protection Systems (if applicable) Fire Safety Official Printed Name Fire Safety Official Signature Date Contact email: Please direct questions to manufactured. lansQ?state.co_us Governor Jared 5. Polis i Rick M. Garcia, Executive Director i Alison George, Division Director «;U 1313 Sherman St., Room 320, Denver, CO 80203 P 303.864.7810 F 303.864.7857 TDD/TTY 303.864.7758 www.dota.cotorado.gov Strengthening Colorado Communities k. Qar.a COLORADO Department of Local Affairs Division of Housing JULY 2023 The following is based on information provided to the Division of Housing (DOH) and may be modified based on the actual findings of the field inspection. DATE:8/12/2025 MANUFACTURER: Northstar Systembuilt CONTACT: Amanda Johanneck ID NO.: 179 PHONE NO.: 507-644-6600 MODEL NO.: NS5794 Pattison DOH P/A NO.: INSPECTION REQUIREMENTS: Check on site: "OC" Inspection Items 1. Completion of the RE301 Electric Ready Space. Spaces have been reserved in panels for future electric ready water heater and range as this house is currently designed for gas on these appliances. There will be a box and conduit for future installation of electric at these appliances and a conduit at the panel if they so choose to switch in the future. 2. Completion of the RS402 Solar Ready Space. Conduit has been installed from floor joists to attic. Customer/Dealer will need to run wire in conduit to panel at reserved space and refer to the suggested location on the Solar Ready Layout plan to install solar panels if desired. 3. Cormpletion of the RV502.1 EV Rea dy Space. There is space in the panel and a conduit stubbed into the floor from panel for a future insta I if the customer/dealer desires to have it installed in the future. The customer does not want us to show a location in the garage, so i# they want an EV charger it will be installed OSBO. 4. Comp€etion of the garage per code 0580. 5. Completion of siding at gablelends. Site contractor will need to install siding after mods are set and stitched together. 6. Vents will need to be completed after roof peaks are raised up and stitched, through the roof per code. 7. Mini Split line sets ran up into attic and will need to be completed/connected to exterior unit at location shown/noted on prints. Site contractor will have to connect across mods to central location in attic to location of exterior unit. 8. Electrical completion and connections. Site contractor will have to connect electrical from mod to mod in crawlspace to site connections. 9. Plumbing completion and connections. Site contractor will have to connect DWV & supply plumbing drops in floor joists from mod to mod per code and connect to onsite connections in crawlspace. They will also need to complete vents up through roof per code. 10. Truss peaks 11. Lumber to complete roof framing (sub -fascia and outlookers, etc) 12. Ridge Vent and shingles 13. Completion of thermal envelope: Installation of insulation at floors, ceilings, and end walls at marriage lines to minimize air infiltration. 14. Blower door test to be done OSBO. 15. Ramp and or stairs and general access to the building OSBO. 16. Foundation support and tie down or anchoring. 17. Contractor will need to install R-8 insulation on all piping installed in un-conditioned space if applies. 18. Contractor will need to install attic ventilation. 19. Contractor will need to install crawlspace light and switch. 20. Contractor will need to install crawlspace min. R-19 insulation as noted on ResCheck. 21. Contractor will need to complete the roof covering after roof trusses are raised and stitched together. 22. Contractor will need to seal bottom after house is set for rim insulation as noted on cross section. 23. Contractor will need to install gas lines from gas appliances, water heater and range down into crawlspace and connect to site connections. NSSB does not install gas lines. Governor Jared S. Polis I Rick M. Garcia, Executive Director I Alison George, Division Director A �ww1 1313 Sherman St., Room 320, Denver, CO 80203 P 303.864.7810 F 303.864.7857 TDD/TrY 303,864.7758 www.dola.colorado.gov ;; 9p Strengthening Colorado Communities J