Loading...
HomeMy WebLinkAboutFinal Blower Door TestResidential Air Infiltration Test Report Test date:3/6/2026 Project name:34 Mariposa Address:34 Mariposa Garfield Code:2018 IECC Conditioned volume:35,979 Cubic Feet Attic:Vented Crawlspace:conditioned Garage:excluded Measured airflow:1,356 CFM50 Cubic Feet per Minute at 50 Pascal Temperature; Inside:65 Temperature; Outside:41 Elevation:6,180 Corrected airflow:1,343 CFM50*Cubic Feet per Minute at 50 Pascal 2018 IECC maximum allowed leakage rate:3.0 ACH50 Air Changes Per Hour at 50 Pascal Tested air leakage rate:2.2 ACH50 Air Changes Per Hour at 50 Pascal Test code compliance:PASS Test notes: Tests were performed by Chris Taylor; Rated Field Inspector, RFIIN #CY5MPL * Test results have been corrected for elevation and air density temperature differential. final blower door