HomeMy WebLinkAboutFinal Blower Door TestResidential Air Infiltration Test Report
Test date:3/6/2026
Project name:34 Mariposa
Address:34 Mariposa
Garfield
Code:2018 IECC
Conditioned volume:35,979 Cubic Feet
Attic:Vented
Crawlspace:conditioned
Garage:excluded
Measured airflow:1,356 CFM50 Cubic Feet per Minute at 50 Pascal
Temperature; Inside:65
Temperature; Outside:41
Elevation:6,180
Corrected airflow:1,343 CFM50*Cubic Feet per Minute at 50 Pascal
2018 IECC maximum allowed leakage rate:3.0 ACH50 Air Changes Per Hour at 50 Pascal
Tested air leakage rate:2.2 ACH50 Air Changes Per Hour at 50 Pascal
Test code compliance:PASS
Test notes:
Tests were performed by Chris Taylor; Rated Field Inspector, RFIIN #CY5MPL
* Test results have been corrected for elevation and air density temperature differential.
final blower door