Loading...
HomeMy WebLinkAboutEngineer's Framing DetailStructural Geotechnical Materials Testing Forensic Job No.198757 March 17,2026 177 Mountain Meadows LLC Attn:Nick Weaver PO Box 1878 Basalt,CO 81621 Re:Structural Modification –Primary Bath Window 177 Mountain Meadows Rd Carbondale,Colorado Dear Mr.Weaver: As requested,personnel of RMG Engineers completed a limited review of the framing at the address referenced above.The purpose of the review was to provide framing recommendations for a window. Reference the framing plan by RMG,Job No.198757,last dated October 9,2025,and the architectural plans by LGA Studios dated August 13,2025. At the 3’-0”wide window in the primary bathroom shower,it is our opinion that a (2)2x8 header with (1)2x6 trimmer stud and (1)2x6 king stud at each end of the header should be provided. Note,no framing other than that described above has been reviewed.I hope this provides the information you requested.Should you have any questions,please do not hesitate to call. Cordially, RMG Engineers 3/17/26 Matthew A.Lundberg,P.E. Structural Project Manager Southern Office: Colorado Springs,CO 80919 719.548.0600 Central Office: Englewood,CO 80112 303.688.9475 Northern Office: Windsor,CO 80550 970.330.1071 rmg-engineers.com