Loading...
HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT B LRE-08-25-9446 JAM ES WATSON NEW SINGLE-FAMILY RESIDENCE W/ ATTACHED GARAGE 484 COUNTY ROAD 113, CARBONDALE Inspectors to Verify minimum life -safety items are in the garage office, the applicant want to reside in during construction. 1) THE APPROVED PLANS ARE TO BE ON -SITE FOR INSPECTIONS. 2) SANITARY FACILITIES ARE REQUIRED TO BE PROVIDED FOR WORKERS. 3) A LIST OF REQUIRED INSPECTIONS WILL BE ATTACHED TO THE PLANS. THE STATE IS TO PERMIT AND APPROVE THE ELECTRICAL WORK. HTTPS://WWW.COLORADO.GOV/PACIFIC/DORA/DPO ELECTRICAL PLUMBING PE RMITS 4) UNDERGROUND UTILITY LOCATES IS THE RESPONSIBILITY OF THE OWNER OR CONTRACTOR. 811 IS THE COLORADO UTILITY LOCATE HOT LINE. 5) DRAINAGE ACROSS PROPERTY LINES SHALL NOT EXCEED THAT WHICH EXISTED PRIOR TO GRADING. EXCESS OR CONCENTRATED DRAINAGE SHALL BE CONTAINED ON SITE OR DIRECTED TO AN APPROVED DRAINAGE FACILITY. EROSION OF THE GROUND IN THE AREA OF DISCHARGE SHALL BE PREVENTED BY INSTALLATION OF NON -EROSIVE DOWN DRAINS OR OTHER DEVICES. 6) ELECTRICAL CODE COMPLIANCE WILL BE DETERMINED BASED ON FIELD INSPECTIONS PERFORMED BY THE STATE ELECTRICAL INSPECTOR, (303) 869-3458. PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN DOCUMENTATION OF THE INSPECTIONS. 7) GEOTECHNICAL OBSERVATION IS REQUIRED WHEN THE EXCAVATION IS COMPLETE AND WRITTEN VERIFICATION BE SUPPLIED AT FOOTING INSPECTION, 1500 PSF. 8) ANY RETAINING WALL OVER 48" TALL REQUIRES TO BE DESIGNED BY A STRUCTURAL OR CIVIL ENGINEER DEPENDING ON THE TYPE OF MATERAIL USED. THE 48" HEIGHT IS MEASURED FROM THE BOTTOM OF THE FOOTING THAT IS BELOW GRADE, NOT THE FACE OF THE WALL. 9) ALL EXTERIOR LIGHTING IS TO BE DOWNCAST AND SHIELDED. 10) SAFETY GLAZING IS NOT DESIGNATED ON THE PLANS. SAFETY GLAZING WILL BE CHECKED DURING THE FRAMING AND FINAL INSPECTION. (IBC 2406.4)