Loading...
HomeMy WebLinkAboutOWTS Permit Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable Project Address: 7979 HWY 13, Rifle, CO 81650 Parcel No.: 212915200069 Owner Name: Dora Gomez & Sergio Mejia Owner Phone: (970) 445-0039 Designed By: BJJ Double J Designer Phone: (970) 210-2816 Number of Bedrooms: _4_ Minimum Tank Capacity: 1,250-gallon Minimum Absorption: 735 ft 2 OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Number _SEPT-9708_______________________________ Permit Type X New X Repair X Remodel/addition X Tank only Issue Date _3/20/2026____________________ Expiration Date 03/20/2027_______________ Permit Conditions: This OWTS Permit is approved on the condition of compliance with the report and design as submitted by BJJ Double J Engineering dated February 16, 2026 revised March 20, 2026. Changes to the design and permit must be approved by Garfield County Public Health and the designer prior to construction. The OWTS will serve a new four-bedroom residence. The OWTS components will consist of a new 1,250-gallon two compartment septic tank set level with access to grade and an effluent filter installed in the outlet tee of the tank. The tank must be on the CDPHE list of approved septic tanks. Effluent will gravity flow to a new distribution box set level with access to grade which will distribute effluent to 768 ft2 of STA. The new STA will consist of four gravelless chamber trenches consisting of 16 ‘Quick 4’ chambers per trench for a total of 64 chambers. Inspection ports will be installed at each end of each trench. Maintain all setbacks and elevations as designed. To assist in scheduling, please contact Garfield County Public Health (970-945-6614 ext. 8150) to notify the start of OWTS construction. Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final inspection of the installed system prior to backfill. NO OWTS COMPONENT SHALL BE BACKFILLED WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction, and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection, and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as-built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of the system will be issued. 3/20/2026 Issued By: Garfield County Environmental Health Department Date