Loading...
HomeMy WebLinkAboutInspection & Alteration Description Updated TO: Garfield County, FROM: Jordan A. Kehoe, P.E. 0060659 DATE: March 26, 2026 RE: 318 Lions Ridge Road Septic Alteration MEMORANDUM Inspection & Alteration Description A field inspection was performed to ensure that the system was operating effectively. Based on conversations with the owners, evaluation of the system and previous application designs, and a review of an inspection performed recently the system is operating as expected with no signs of failing or inoperable portions of the system. The only recommendation was to pump out the tank, which was performed by the owners recently. The ‘Application – Permit Old’ document shows the system was designed and installed for 7 bedrooms. As can be seen in the property record card, there are only 5 bedrooms for the existing residence . A review of the existing residence shows that only 4 conforming bedrooms exist in the residence. The approved onsite wastewater treatment system (OWTS) has capacity for additional bedrooms. The proposed project is to construct a mother-in-law with one bedroom in staying compliant with the previously approved application and design. The installed system has the soil treatment area (STA) large enough for 7 bedrooms based on site and soil conditions. An additional inspection was performed to understand the vegetation growth at the lower end of the STA. During the inspection, the distribution box was checked for any noticeable issues. The distribution box appeared to be operating normally and after walking through the STA there was no noticeable odors or moisture indicating that the STA had broken or failing components. Suggestion to add a flow equalizer if any abnormal conditions for the STA occur in the future. Alteration to the system includes including an additional 1,000-gallon two compartment septic tank and tying into the existing OWTS system. The STA will stay unmodified as it was designed and installed for 7 bedrooms.