Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
OWTS Design Specs
Item # 1 M 1060-2CP 24" ACCESS OPEMM 1060 Gallon Two Compartment Infiltrator® Poly Tank IV" 1'2r Top /iew Section View • Compliant with CSA and IAPMO Standards • PVC risers available SEAM CLIP • Secondary safety screen available with PVC riser (TYPICAL) • Maximum burial depth is 48" • Minumum burial depth is 6" LIFTING STRAP • Tank is not rated for vehicular traffic loading (TYPICAL) Exterior of manhole cover includes the following warning: "DANGER DO NOT ENTER: POISON GASES" I' TANK TOP CONTINUOUS HALF GASKET TANK i1: INTERIOR SEAM CLIP ALIGNMENT DOWEL (34) TANK BOTTOM HALF Mid -Height Seam Section Tank indudes lids ni M F r Digging Specs I Invert Dimensions Net Weight - Capacity 12' Long x 7' Wide Inlet Outlet Length Width Height 47" 44" 127" 62.2" 54.7 1094 gDl 320 Ibs Water & Wastewater O VALLEY • Products O P T, Inc. • service (719) 395.6764 i .7 EXTERIOR HEIGHT I End View QMIN, FILTRAT0R' septic tanks MttJRA?M i1l=4 W_ MM Co. Rd 317 P.O BOK925 RnAm Vida. M 91211 Fax: (!7a) 3V0-i1zf Website: www.vaUeyFxecastoom Enudl: fronbdesk@va1Wyprecasto0m Residential Biotube' Effluent Filters Applications Our patented* 4-in. (100-mm) Biotube Effluent Filters, Biotube Jr., Biotube Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic tanks and have a lifetime warranty. They prevent large solids from leaving the tank, dramatically improving wastewater quality and extending the life of residential drainfields. 4-in. (100-mm) Biotube Effluent FiW71 4-in. (100-mm) Biotube Jr. (4-in. Biotube cartridge avail- able separately as Insert Filter) 8-in. (200-mm) Base Inlet Filter 4-in. (100-mm) Insert Filter r Orenco' superior effluent filters resist clogging better than all other brands. Our stan- dard, full-sized 4-in. (I00-ntnt) Biotube L•fjluent /ilter provides ntaxintttm long-tenn protection in a complete package, with housing. Our 4-in. (100-mm) Biotube fr., at half the size of our standard model, has more filtering capacity than the fitll-sized filters sold by other manufacturers. For tanks with existing outlet tees, rile Biotube Insert Filter is ideal. And for low profile tanks, there's the Base Inlet Filter. * Covered by patent numbers 5,492,635 and 4,439,323 To Order Call your nearest Orenco Systems®, Inc. distributor. For nearest distribu- tor, call Orenco at 800-348-9843 or go to www.orenco.com and click on Distributor Locator." APS-FT-1 Rev. 3A ©11/10 Orenco Systems®, Inc. Standard Features & Benefits • Has 5-10times more flow area than other brands, so lasts many times longer between clean- ings, increasing homeowner satisfaction • Installs in min- utes inside new or existing tanks; extendible tee handle for easy removal Optional Features & Benefits • Alarm available, to signal the need for cleaning • Flow modulating discharge orifices available to limit flow rate leaving tank, mitigat- ing surges and increasing retention time • Custom and commercial sizes available • Easy to clean by simply hosing off whenever the tank needs pumping • Removes about two-thirds of sus- pended solids, on average, extending drainfield life • Corrosion -proof construction, to ensure long life • Lifetime warranty Biotube Filtering Process Effluent from the relatively clear zone of the septic tank, between the scum and sludge layers, horizontally enters the Biotube Effluent Filter. Effluentthen enters the annular space between the housing and the Biotubes, utilizing the Biotubes' entire surface for filtering. Particles largerthan the Biotube"s mesh are prevented from leaving the tank. Orenco Systems" Incorporated Changing the Way the Wald Does Wasretvater'` www.orenco.com Nomenclatures 41n. Biotube Filter (standard) FT ❑ ❑ 04❑❑-❑❑❑1 I Options: Blank = no options M = flow modulation plate installed A = float bracket attached Cartridge height 28" and 36" are standard Housing height: 36" and 44" are standard Filter diameter (inches) W = fits Type 3034 outlet pipe S = fits Schedule 40 outlet pipe Blank = 1/8" filtration P = 1/16" filtration Biotube effluent filter series 8-In. Biotube Filter (base inlet model) Fr ❑ 08 22 -14 B 0 Options: A = float bracket FS = 2" outlet orifice FSO = 2" outlet orifice and overflow plate Base inlet model Cartridge height:14" standard Housing height: 22" standard Filter diameter (inches) 08 = 8" Blank = 1/8" filtration P = 1/16" filtration Biotube effluent filter series Also available with coupling and sleeve as a "kit": FT-OVERFLOWKIT 41n. Biotube Jr. (includes cartridge and housing) Fri ❑❑0418= I Opt1ons: Blank - no options M = flow modulation plate installed A = float bracket attached Cartridge height (inches) Fitter diameter (inches) W = fits Type 3034 outlet tee S = fits Schedule 40 outiet tee Blank = 1/8" filtration P = 1/16" filtration I Junior series Biotube effluent filter series 4-in. Biotube Filter Insert (cartridge only) FT i ❑04 18 -❑-❑ For customized options (e.g., NC indicates North Carolina regions) tw = fits Type 3034 outlet tee S = fits Schedule 40 outlet tee Cartridge height (inches) Filter diameter (inches) Blank = 1/8" filtration P = 1/16" filtration Insert Biotube effluent filter series Orin. Biotube Effluent Filter Extendible Stainless ste e g Top se — Air V Biotube° fi Solid Filter I Distributed By: 4-in. Biotube Jr. Double Walled PVC Riser & Lid Options Poly Lid (Static load tested to 5000 Ibs) • Skid resistance surface • Available in green Highest level of W Protection included • Includes a foam gasket for airtight and watertight applications Includes square drive screws to discourage unauthorized entry Insulation panels achieve R-10 insulation rating Double Walled PVC Riser 2" of Insulation Standard Orenco ® DuraFiber m Access Lids (FLD) Not recommended for vehicular traffic 24" and 30" Diameters • Solid, resin4nfused fiberglass construction • 20,0004b breaking strength • Standard green or brown colors • Available with or without urethane lid gasket • Available with carbon filtration • 4 stainless steel flathead socket cap screws & hex key wrench • Insulated lids available - 2" or 4" • Available in 24" and W Diameter • Cut to length • Sold in +/- 2" increments • Must be cut between ribs Water & Wastewater rL7PRECAST', VALLEY " teems • Products Inc. • Service 28005 Co. Rd 317 P.O. Box925 Fax: (719) 395-3727 & 9MjM 1 Websiba: www.valleyprec:astoom Email: frond com (719) 395-6764 POLYLOK DISTRIBUTION BOX, RISERS, AND LID - 2.4511 16" UD-BOX 6 & UD43OX 8 SIDE CUT OUT TO ACCEPT POLYLOK SEAL NO.3001 UD-BOX 6" RISER i UD-BOX 12" RISER 20" COVER FOR RISER & D-BOX Water & Wastewater Vo VALLEY : ��� PRECAST, Inc. • semos NOT TO SCALE ROTO-FLOW 4" NOT TO SCALE POLYLOCK EQUALIZER W-NOTCH' WFJR WEIR SHAPE IS (EK- o SELF LEVELNO RE -4FR FORA.L4 PIPE D —T+ T—M— NOT TO SCALE GASIETED SEAL ON LID & RISER (719) 3954764 28005OD` RCL 317 P.O. 130K925 Fax: (719) 3954M Buem Vokk CO81211 Webeft: www.valleyprecastoom Email: frontdesk@valleyp w3Stoom Lul 0 O J O� 2 H V � GHQ W U Lu LL CO Z Q O ?r O d O Z z H N Q W a' H J LL Z cli N O O O O jejS Ae:4eS 4j!M deusZ3\deusZ3\Sb3SIU - 56\s-LonGObd ISI--ZO\MaN sooinosou leoiuyoal\:t) J DIM ON0 Qu1ck4 Plus All -in -One Periscope Center Structural Columns Quick4 Plus All -in -One 12 Endcap The Quick4 Plus Standard Chamber offers maximum strength through its two center structural columns. This chamber can be installed in a 36-inch-wide trench. Like the original line of Quick4 chambers, it offers advanced contouring capability with its Contour Swivel Connection'"' which permits 10-degree turns, right and left. It is also available in four -foot lengths to provide optimal installation flexibility. The Quick4 Plus All -in -One 12 Endcap, and the Quick4 Periscope are available with this chamber, providing increased flexibility in system configurations. Quick4 Plus Standard Chamber • Two center structural columns offer increased stability and superior strength • Advanced contouring connections • Latching mechanism allows for quick installation • Four -foot chamber lengths are easy to handle and install • Supports wheel loads of 16,000 Ibs/axle with 12" of cover Quick4 Plus All -in -One 12 Endcap • May be used at the end of chamber row for an inlet/ outlet or can be installed mid -trench • Mid -trench connection feature allows construction of chamber rows with center feed, as an alternative to inletting at the ends of chamber rows • Center -feed connection allows for easy installation of serial distribution systems • Pipe connection options include sides, ends or top Quick4 Plus All -in -One Periscope • Allows for raised invert installations • 180' directional inletting • Twelve inch raised invert great for serial applications PLUS -":,#I f CNAtiIBER •11l[IN : AMNKI)CS443VA0I1 Quick4 Plus Standard Chamber Side and End Views Quick4 Plus All -in -One 12 Encap Front, Side and End Views k11 Quick4 Plus All -in -One Periscope gUICK4 PLUS ALL-I11-0NE PERISCOPE (36o'SWIVEL ) 12.7" INVERT rO�w�O� ���vi�,i I��.vllil� 1 I DUlCI14 PLUS 6 NE 12 ENDCAP NDCAP —+j I— Quick4 Plus Standard Chamber Specifications Size (W x L x H) ............. 34" x 53" x 12" (86 cm x 135 cm x 31 cm) EffectiveLength........................................................ 48" (122 cm) Invert Height ................. 0,6", 5.3", 8.011, 12,7" (1.5 cm, 8.4 cm, 18.5 cm, 22.6 cm) INFILTRATOR SYSTEMS, INC. STANDARD LIMITED WARRANTY to; 7ne structural mtegnly of each chamber, end plate, wedge and other accessory rrwnulactured by Infiltrator ( "Units'). when installed and oporated in a leacnhetd of an onsiIe septic system in accordance with Infiltrator s instructions, is warranted to the original purchaser (-Holder ) against defectwe materials and worxmanship fat one year from the date that the septic pmm.l is Issued for the septic system containing the Units. prov,ded, howeverthat it a septic permit ,s not required by applicable law, the warranty period will begin upon the data that installation of the septic system commences. To exercise its warranty righit. Holder mu-m notily Infiltrator in wailing at its Cwporale Headquarters in Old Saybrook. Connecticut within fifteen (15) days of the alleged defect. Infiltrator will supply replacement Unis for Un.ls determined by Infiltrator to be wvurud by this Limited Warranty. Infiltrator's liability specifically excludes the cost of removal and/or nswllaten of the Units. (b)THE LIMITED WARRANTY AND REMEDIES IN SUBPARAGRAPH (a) ARE EXCLUSIVE. THERE ARE NO OTHER WARRANTIES WITH RESPECT TO THE UNITS, INCLUDING NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE (c) This Limited Warranty shall be void if any part of the chamber system Is manufactured by anyone other than Infiltrator. The Limped Warranty does not extend to incidental, consequential, special or indirect damages. Infdtiator shall not be fable fcr penalties or liquidated damages. including loss of production and profits, labor and materials, overhead costs, or other losses nr expenses incurred by the Holder or any third party. Specifically excluded from Limited Warranty coverage are damage to tho Units due to ordinary wear and tear, allaralion, accident. m sise, abuse or neglect of the Units; the Units being subjected to vehicle traffic or other conditions which are not permitted by the installation instructions; failure to maintain the minimum ground covers set forth in the installation instructions; the placement of improper materials into the system containing the tine•. failure of the Unrls or the septic system due to improper song or improper siring, excessive water usage, improper grease disposal, or improper operation. or any other event not caused by Infiltrator This Limited Warranty shall be void if the Holder fats to comply with all of the forms set Icrlh -n irus L"naed Warranty. Further. n no event shall Infiltrator be responsible for any loss or damage to the Holder, the Units or any In"d early resulfni from urstallainn or shicmcnl, or hen any product Lability cluims of Mulder or any Ifurd party. For this Limited Warra•dy to apply. the Units must be installed n accordance with all site conditions required by swlo and local codes; all other applicable laws; and Infiltrator's installation instructions. (d) No representative of Infiltrator has the authority to change or extend this Limited Warranty. No warranty applies to any party other than the original Holder. The above represents the Standard Limited Warranty offered by Infiltrator.• A limited number of states and counties have different warranty requirements. Any purchaser of Units should contact Infiltrator's Corporate Headquarters in Old Saybrook, Connecticut, prior to such purchase, to obtain a copy of the applicable warranty, and should carefully read that warranty prior to the purchase of Units. INFILTRATOR® systems inc. 6 Business Park Road • P.O. Box 768 Old Saybrook, CT 06475 860.577.7000 • FAX 860.577.7001 800.221.4436 www.infiltratorsystems.com U.S. Patents 4,759,661; 5,017,041; 5.156,488; 5,336.017; 5,401.116; 5.401,459; 5,511.903; 5.716.163; 5,588,778; 5,839,644 Canadian Patents: 1,329,959; 2,004,564 Other patents pending. Infiltrator, Equalizer, Quick4 and Quick4 Plus are registered trademarks of Infiltrator Systems Inc. Infiltrator is a registered trademark in France. Infiltrator Systems Inc. is a registered trademark in Mexico. Contour Swivel Connection is a trademark of Infiltrator Systems Inc. © 2009 Infiltrator Systems Inc. Printed in U.S.A. PLUS0510101SI-2