HomeMy WebLinkAboutRevised OWTS Plan with Grates in Risers 07.02.2026W TP TP C/ O > > > > > C/ O C/ O C/ O 6' MIN. TYP. SOIL TREATMENT AREA (STA) 90 QUICK 4 INFILTRATOR (6 x 15) OR 72 ADS ARC36 UNITS (6 x 12) IN A TRENCH CONFIGURATION (SEE DETAIL AND SETBACK NOTES) NOTES: PROPERTY LINES MAY BE BEYOND THE MAPPED AREA. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. PR O P O S E D 3- B E D R O O M RES I D E N C E PR O P E R T Y L I N E BUI L D I N G S E T B A C K Co f f e e P o t R o a d Cof f e e P o t R o a d 94 3 0 94 2 0 94 1 0 94 0 0 9 3 9 0 9 3 8 2 9 3 7 0 9 3 6 0 93 5 0 9 3 4 0 93 3 0 9320 93 2 0 9310 93 3 0 933 0 18' ' Ø 4'' Ø 4'' Ø 4'' Ø 4'' Ø 4'' Ø 4''Ø 4''Ø 4''Ø 4''Ø 4''Ø 4''Ø 4''Ø 4''Ø 4''Ø 1 0 0 ' S B 100 ' S B 100'SB 100 ' S B 10 0 ' S B 1 0 0 ' S B 10 0 ' S B PR O P E R T Y L I N E 50 ' S E T B A C K 25' SETBACK> > > > > > > C/ O C/ O C/O TP INSTALL A TWO-WAY CLEANOUT OUTSIDE THE BUILDING (SEE DETAIL) INSTALL 1000-GALLON TWO-COMPARTMENT SEPTIC TANK WITH AN EFFLUENT FILTER IN THE OUTLET RISER (SEE DETAIL & SETBACK NOTES) INSPECTION PORT AT EACH END OF EACH TRENCH, TYP. WELL & WATERLINE 100' SETBACK FROM WELL APPROX. TEST PIT LOCATION, TYP. 4"Ø SCH.40 PVC SEWER, @ 2% MIN. SLOPE W/ 3.5' MIN. COVER AND PIPE INSULATION (SEE DETAIL) CONSTRUCT SWALE ABOVE AND AROUND THE STA FIELD (SEE DETAIL) INSTALL TWO-WAY CLEANOUTS EVERY 100 LF MIN. AND AT MAJOR BENDS, TYP. (SEE DETAIL) > > > > C/O 4'' Ø DISTRIBUTION BOX (SEE DETAIL) 94 3 0 9 4 2 0 9 4 1 0 94 1 8 941 6 94 1 4 94 1 2 9 4 1 0 94 3 0 9420 9 4 2 0 9 4 2 6 942 0 SCF SCF SC F SC F S C F S C F S C F SC F SCF 37110DERIC J O N WA L T E R COL O R A D O LICE N S E D P R O F E SSIONA L E N G INEER 6/17/26 00 50'100' Scale: 1" = 50' SURFACE 2' 8. 5 ' ± MAINTENANCE NOTES 1.TO ENCOURAGE THE HEALTH AND LONGEVITY OF THE OWTS SYSTEM, THE OWNER SHALL CONSIDER THE FOLLOWING: 1.A.MINIMIZE THE AMOUNT OF WATER THAT GOES DOWN THE DRAIN, THE BETTER YOUR SYSTEM WILL WORK. 1.B.MINIMIZE SOLIDS GOING DOWN THE DRAIN. 1.C.ELIMINATE GARBAGE DISPOSALS OR KEEP THE USE OF GARBAGE DISPOSALS TO A MINIMUM. 1.D.MINIMIZE GREASE AND OILS THAT GO DOWN THE DRAIN. 1.E.USE LINT FILTERS ON LAUNDRY MACHINE DRAINS. 1.F.KEEP SAND AND DIRT OUT OF THE BUILDING DRAIN. 1.G.AVOID FLUSHING SANITARY NAPKINS OR PAPER PRODUCTS OTHER THAN TOILET PAPER. 1.H.DO NOT USE LYE-BASED DRAIN UNCLOGGER CHEMICALS SUCH AS DRAINO, OVEN-OFF, OR OTHER STRONG CLEANING AGENTS. 1.I.DO NOT PUT ANY “ROOT DETERRENTS” DOWN THE DRAIN. 1.J.DO NOT POUR PAINT THINNER, PESTICIDES, PAINTS OR PHOTO LAB CHEMICALS DOWN THE DRAIN 1.K.MINIMIZE USE OF CHLORINE BLEACH AND TOILET ADDITIVES. 2.THE OWNER SHALL CONTRACT WITH A SEPTIC TANK INSPECTOR TO INSPECT THE TANK ANNUALLY FOR GREASE AND SEDIMENT ACCUMULATION. THE INSPECTOR SHALL REMOVED AND PROPERLY DISPOSED OF ACCUMULATED GREASE AND SEDIMENT AS NEEDED TO ENSURE PROPER FUNCTION OF THE SYSTEM. TBD Coffee Pot Road County of Garfield, State of Colorado Parcel No: 1933-334-00-009 Vicinity Map DotseroSITE ATTACH REMOVABLE CAP OR THREADED CLEANOUT ASSEMBLY. INSTALL MARKER IF CAP IS TO BE BURIED. FINISH GRADE 4"Ø PVC RISER 4"Ø PVC TWO-WAY CLEANOUT TEE 4"Ø SEWER LINE 12" SQ. NYLOPLAST H-20 SOLID COVER ASSEMBLY REMOVABLE PVC CAP FLUSH WITH SURFACE 24"x24"x6" CONCRETE IN LANDSCAPE IN HARDSCAPE To Gypsum Scale: N.T.S. SITE & SOILS EVALUATION Scale: N.T.S. TWO-WAY CLEANOUT 6. 5 ' ' ± NOTES: THIS PLAN SET IS INTENDED TO BE PLOTTED IN COLOR. FAILURE TO DO SO MAY RESULT IN MISSING DATA & INFORMATION CRITICAL TO THE PROJECT. SITE EVALUATION 1.SITE AND SOIL EVALUATIONS WERE PERFORMED BY: DERIC J. WALTER, PE KEVIN DYE, PE BOUNDARIES UNLIMITED INC.GEO QUEST 923 COOPER AVE., STE. 201 PO BOX 1372 GLENWOOD SPRINGS, CO 81601 RIFLE, COLORADO 81650 970.945.5252 970.318.6784 2.EVALUATION DATE(S): 5/18/26. 3.SOIL WAS CLASSIFIED BY THE GEOTECHNICAL ENGINEER (GEO QUEST (PROJECT #26-142, May 18, 2026) AS USDA SANDY CLAY LOAM; TYPE 3A; WITH AN LTAR OF 0.30 GPD/SF. 4.SETBACK REQUIREMENTS FOR A TREATMENT LEVEL 1 STA TRENCH/BED, UNLINED SAND FILTER OR SEEPAGE PIT (PER TABLE 7-1) AND AN ADWF=450 GPD: 4.A.SPRING, WELL OR POTABLE CISTERN=100' 4.B.POTABLE WATER SUPPLY LINE=25' 4.C.STRUCTURE W/ BASEMENT/CRAWL SPACE=20' 4.D.STRUCTURE W/O BASEMENT/CRAWL SPACE=10' 4.E.PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH=10' 4.F.INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE=25' 4.G.LAKE, WATER COURSE, IRRIGATION DITCH, STREAM OR WETLAND=50' 4.H.DRY GULCH, CUT BANK OR FILL AREA=25' 4.I.SEPTIC TANK=5' 4.J.RESTRICTIVE LAYER OR GROUNDWATER (VERTICAL): 4' (TREATMENT LEVEL 1, GRAVITY FEED) 3.SETBACK REQUIREMENTS FOR THE SEPTIC TANK SHALL BE (PER TABLE 7-1): 3.A.SPRING, WELL OR POTABLE CISTERN=50' 3.B.POTABLE WATER SUPPLY LINE=10' 3.C.STRUCTURE W/ BASEMENT/CRAWL SPACE=5' 3.D.STRUCTURE W/O BASEMENT/CRAWL SPACE=5' 3.E.PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH=10' 3.F.INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE=10' 3.G.LAKE WATER COURSE, IRRIGATION DITCH, STREAM OR WETLAND=50' 3.H.DRY GULCH, CUT BANK OR FILL AREA=10' 3.I.STA TRENCH/BED, UNLINED SAND FILTER OR SEEPAGE PIT=5' FLOW GENERAL ABSORPTION AREA NOTES 1.INSTALL CHAMBER UNITS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 2.ABSORPTION TRENCHES SHALL BE 3' WIDE OR LESS AND PARALLEL THE GROUND SURFACE CONTOURS. PARALLELING TRENCHES SHALL BE SEPARATED BY A DISTANCE OF 6' MIN. 3.THE BOTTOM OF THE ABSORPTION TRENCHES SHALL BE LEVEL AND THE BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE ANY SOIL SMEARS INCURRED DURING THE EXCAVATION. FAILURE TO DO SO MAY REQUIRE THE CONTRACTOR TO REPLACE THE ABSORPTION FIELD AT HIS/HER OWN EXPENSE. 4.DRAINAGE SWALES ARE TO BE PROVIDED ABOVE AND AROUND THE FIELD, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA. 5.NO EXCAVATION OF THE ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER THE ABSORPTION AREA IS STRICTLY PROHIBITED. 6.UNSUITABLE MATERIAL EXISTING WITHIN THE FIELD SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST OF IMPORTED LOAMY SAND OR SANDY GRAVEL. THE ENGINEER SHALL BE CONTACTED IF BEDROCK OR GROUNDWATER IS ENCOUNTERED IN THE OVER-EXCAVATION. 7.TOPSOIL COVER MAY BE VARIED (1-FOOT MINIMUM, 2-FOOT MAXIMUM) TO ALLOW FOR LANDSCAPING. 36" MAX. UNDISTURBED NATIVE SOILS 6' (MIN.) BOTTOM TO BE LEVEL AND FLAT OVER ENTIRE AREA TO WITHIN 0.05'±. (TYP.) REMOVE ANY ENCOUNTERED BOULDERS AND BACKFILL WITH LOAMY SAND OR SANDY GRAVELS. DO NOT USE COMPACTED MATERIALS. DO NOT WALK ON OR COMPACT BOTTOM OF TRENCH. FINISHED GROUND - MAINTAIN POSITIVE SLOPE AWAY FROM TOP SURFACE OF THE CHAMBER TRENCHES. PVC COUPLING FOR SUPPORT STANDARD INSPECTION PORT, TYP. (4"Ø PVC SOLID PIPE CUT TO FIT. LOCATE PER PLAN VIEW. ATTACH REMOVABLE CAP OR THREADED CLEANOUT ASSEMBLY. INFLOW PIPE SHALL ENTER THE UPPER KNOCKOUTS GRAVELLESS CHAMBER SYSTEM: INFILTRATOR QUICK 4, ADVANCED DRAINAGE SYSTEMS BIODIFFUSER (STANDARD), OR ENGINEER APPROVED EQUAL. EX. GRA D E 5 % ± 1% MIN 3:1 M A X G R A D E FILL CIRCULAR IRRIGATION-STYLE VALVE BOX & COVER - LID COLOR PURPLE OR GREEN - LABEL "SEWER" 3:1 M A X G R A D E 1' MIN 2' MAX 1% MIN FILL 4"Ø PERFORATED PVC PIPE. EXTEND PIPE TO REST ON BOTTOM OF THE BED Scale: N.T.S. GRAVELLESS CHAMBER ABSORPTION TRENCH To Glenwood Springs SYSTEM DESIGN & CONSTRUCTION NOTES: 1.ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CDPHE REGULATION 43 ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) REGULATION, MOST CURRENT EDITION AND LOCAL AGENCY REQUIREMENTS WHICH MAY OR MAY NOT SPECIFICALLY BE NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR KNOWING AND CONFORMING TO SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. THIS DRAWING DOES NOT CONSTITUTE AN OWTS PERMIT. A PERMIT MUST BE OBTAINED FROM APPROPRIATE LOCAL AGENCY. THE CONTRACTOR MUST CONTACT THE LOCAL AGENCY HEALTH DEPARTMENT AND THE PROJECT ENGINEER FOR INSPECTIONS OF THE CONSTRUCTED SYSTEM BEFORE BACKFILL. A REQUEST FOR INSPECTION BY THE PROJECT ENGINEER AND THE COUNTY ENVIRONMENTAL HEALTH OFFICER MUST BE MADE AT LEAST 72-HOURS PRIOR TO THE DESIRED TIME OF BACKFILLING. 2.DEMAND CALCULATIONS (SEC.43.6.A.2.h) 2.A.THREE (3) BEDROOM PRIMARY RESIDENCE USING TREATMENT LEVEL 1 (TL1). 2.B.AVERAGE DAILY WASTEWATER FLOW (ADWF) AND ORGANIC LOAD RATE (BOD5): 2.B.1.SINGLE FAMILY DWELLING: 75 gpdc & 0.20 BOD5 lbs/day 2.B.2.ADWF: 2.B.2.1.PRIMARY RESIDENCE (3 BEDROOM) = 450 gpd (MINIMUM PER TABLE 6-1) 2.B.2.2.ADWF = 450 gpd 2.B.3.BOD5 = 0.20 lbs/day * 6 PERSONS = 1.20 lbs/day BOD5 mg/L = BOD5*1,000,000 = 1.20 lbs/day*1,000,000 = 320 mg/L ADWF*8.34 450 gpd*8.34 2.B.4.CBOD5 = BOD5 * 0.85 = 272 mg/L 3.SEPTIC TANK (SEC.43.9.B.2.a): 3.A.INSTALL A 1,000 GALLON TWO-COMPARTMENT SEPTIC TANK WITH EFFLUENT FILTER IN THE OUTLET RISER. (TABLE 9-1) 3.B.THE TANK IS NOT SUBJECT TO BUOYANCY. 4.SOIL TREATMENT AREA (STA) CALCULATIONS: 4.A.THE STA AREA SLOPES GENTLE TO MODERATE. 4.B.LONG TERM ACCEPTANCE RATE (LTAR) FOR TREATMENT LEVEL 1 (TL1) OF 0.30 gpd/SF (SEE SITE & SOILS EVALUATION NOTES/DETAIL). 4.C.MINIMUM SOIL TREATMENT AREA, A (PHASE 1): A = ADWF = 450 = 1500 S.F. LTAR 0.30 gpd/S.F. 4.D.SIZE ADJUSTMENT FACTORS: GRAVITY TRENCH = 1.0; CHAMBERS = 0.7 (TABLE 10-1A). 4.E.A,adj = 1500 SF * 1.0* 0.7 = 1050 SF 4.F.GRAVELLESS CHAMBER TRENCH SYSTEM: 4.F.1.INFILTRATOR QUICK4: 1050 SF / 12 SF/UNIT = 88 UNITS. INSTALL 90 UNITS IN SIX (6) TRENCHES CONTAINING FIFTEEN (15) UNITS EACH. 4.F.2.ADS ARC 36: 1050 SF / 15 SF/UNIT = 70 UNITS. INSTALL 72 UNITS IN SIX (X) TRENCHES CONTAINING TWELVE (12) UNITS EACH. 5.THIS SYSTEM IS SIZED FOR TYPICAL HOUSEHOLD WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS AND/OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. BACKWASH AND FLUSHING FLOWS SHALL BE DISPOSED OF WITHIN A SEPARATE INFILTRATIVE SYSTEM. 6.CLEAN OUTS ARE REQUIRED AT THE HOUSE AND AT ALL BENDS GREATER THAN 45° AND AT LEAST EVERY 100-FEET BETWEEN THE HOUSE AND THE SEPTIC TANK. 7.THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS THROUGHOUT THE SYSTEM TO PREVENT INFILTRATION. 8.INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS PORTS TO FINAL GRADE. PORTS SHALL BE MARKED IF CAPS ARE TO BE BURIED. 9.INSTALL 3-INCHES OF BLUEBOARD INSULATION, 3-FEET WIDE, OVER SEWER AND EFFLUENT PIPE WHEREVER DEPTH IS LESS THAN 3-FEET. UNDER NO CIRCUMSTANCES SHALL COVER BE LESS THAN 2-FEET. 10.SITE PLAN INFORMATION FROM OTHERS. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. NORTH 923 Cooper Avenue, Ste. 201 Glenwood Springs, CO 81601 tele: 970.945.5252 www.bu-inc.com Engineer or Surveyor Seal Sheet Client Information: Project No.: Filename: Designer: Drafter: Date: N: \ P R O J E C T S \ 2 0 2 5 \ 2 5 0 3 2 - M a n c i n i - C o f f e e P o t \ d w g \ 2 5 0 3 2 - V - T o p o - R e v i s e d . d w g 6/ 1 8 / 2 0 2 6 1 2 : 4 6 P M Subsurface Utility Engineering (SUE) Required Project: If "Yes", SUE Certification by: Firm: Job #: Date: Agency Approval Agency: Dept: By: Date: Comments: RevisionDate 6/17/26 djw djw 25032-v-topo-revised.dwg 25032 586.739.5210 Sterling Heights, MI 48314 41500 Mound Road Steven Mancini GA R F I E L D C O U N T Y , C O L O R A D O On s i t e W a s t e w a t e r T r e a t m e n t S y s t e m ( O W T S ) Ma n c i n i R e s i d e n c e - C o f f e e P o t R o a d C.2 No N/A N/A N/A I-70 4" PVC TEE/RISER WITH EFFLUENT FILTER ON THE TANK OUTLET 4" PVC TEE/RISER TOPSOIL SANDY CLAY LOAM SAND, CLAY, GRAVEL, BROWN, MOIST, FEW COBBLES Scale: N.T.S. PIPE INSULATION 1'-0" 1' - 0 " 4" DUPONT STYROFOAM BRAND HIGHLOAD 60 XPS INSULATION PIPE 1/2" MINUS ONSITE SELECT MATERIAL X 1 18 " M I N . ADJACENT GRADE SIDE SLOPES @ 3:1 MIN. LINE ALL SWALES WITH FLOWLINE GRADES EXCEEDING 5% WITH 9"Ø NOMINAL ANGULAR ROCK RIPRAP OR A PERMANENT EROSION CONTROL FABRIC (NORTH AMERICAN GREEN VMAX S200 OR EQUAL) INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. Scale: N.T.S. DRAINAGE SWALE RISER WITH INTERIOR SAFETY GRATE (ORENCO RLA 24-2, RTS-FLD-24G-B, OR MANUFACTURER SUPPLIED EQUAL)