HomeMy WebLinkAboutOWTS Permit
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 7332 County Road 100, Carbondale Parcel No.: _239118101001
Owner Name: Thaddeus Eshelman Owner Phone: (970) 379-1506
Designer: CBO Inc. Designer Phone: (970) 309-5259
Number of Bedrooms: 2 Minimum Tank Capacity: 1-gallons Minimum Absorption: 224 ft 2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT-9814_______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _7/13/2026____________________ Expiration Date_7/13/2027_________________
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with scope of work and site plan as
submitted by Sopris Engineering dated March 27, 2026. Changes to the design and permit must be
approved by Garfield County Public Health prior to construction.
The new OWTS will serve a 3-bedroom main residence and future 2-bedroom ADU. A new 4-inch
SDR 35 sewer line with a cleanout will be encased in Schedule 40 PVC within 50 feet of the well to
the East of the proposed ADU. Effluent will gravity flow to the new 1500-gallon septic tank and 720
ft2 of STA installed April 2026 and documented by permit SEPT-9519. The pump wiring and
installation; visual and high water alarms; and control panel down stream of the new 1500 gallon
septic tank must be inspected and approved. A residual head (squirt test) as a part of the
finalization of SEPT-9519 must be completed prior to final approval. Maintain all setbacks and
elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill. NO OWTS COMPONENT SHALL BE BACKFILLED
WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as-built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
7/13/2026
Issued By: Garfield County Environmental Health
Department
Date