Loading...
HomeMy WebLinkAboutHigh Strength Bolt Inspection ReportMonument Steel Inspection, LLC. Welding, Mechanical Fastening, and Industrial Adhesive Inspection. P.O.Box 23388 Glade Park, CO. 81523 Phone: 318-469-2279 Email — monumentsteelinspectionllc22 a-)gmail.com TO: Mr. Tyler Miles J. Martinez Battlement Mesa Clubhouse Addition 6-29-26 QUANTITY DESCRIPTION 2 hrs Inspection time 1 hr Report time INVOICE Invoice #: 1102 Date: 7-7-2026 UNIT PRICE TOTAL $90.00/hr $180.00 $90.00/hr $90.00 100 miles Mileage chg. $0.725/mi $72.50 TOTAL DUE ON RECEIPT OF INVOICE $342.50 Make all checks payable to Monument Steel Inspection, LLC. Or Send payment through Venmo @welderbrik, inBuild, or BILL. For ACH information, please call or email. If you have any questions concerning this invoice, contact Daniel Bricker, 318-469-2279. Late fees totaling 5% will be accrued after 30 days of non-payment. Additional fees may result after 60 days of non-payment. THANK YOU FOR YOUR BUSINESS! MONUMENT STEEL INSPEC-FION, LLC Mr. Tyler Miles 6-29-2026 Re: Battlement Mesa Clubhouse Addition Dear Mr. Miles, As requested, structural steel special inspection was conducted per the IBC 2018 Edition - Chapter 17: Structural Tests and Special Inspection and the Town of Parachute requirements. I arrived on -site at 8:00 AM. I met with you to review project requirements and material ready for inspection. I have reviewed the welders' certifications and the welding procedure and found them both to be acceptable. Visual welding inspection was conducted on the patio and cover addition and remodel on the rear of the clubhouse. I observed the column to stiffener plate fillet welds, the beam to end plate fillet welds, and the column to bucket fillet welds. Upon completion, I observed all fillet welds to be in compliance with project specifications and the inspection requirements as stated in Clause 8 of the AWS D1.1 Structural Welding Code — Steel:2020 Edition. High strength bolt inspection was conducted on the patio and cover addition and remodel on the rear of the clubhouse. I observed all bolts to be 3/4" ASTM A325 plain body bolts fitted with a hardened flat washer properly positioned under the turning surface of a heavy hex nut. Upon completion, I observed all bolts to be in compliance with project specifications and the inspection criteria of the American Institute of Steel Construction (RISC) and the Research Council in Structural Connections (RCSC). Monument Steel Inspection, LLC 318.469.2279 PO Box 23388 Glade Park, CO 81523 monumentsteelinspectionllc22@gmail.com Resp ctfully submitted, Dan Bricker, CWI AWS CWI #09052051 Monument Steel Inspection ® Da a I. icker Aw$ Do 1 2051 . 511 /2027 Monument Steel Inspection, LLC PO Box 23388 Glade Park, CO 81523 318.469.2279 monumentsteelinspectionllc22@gmaii.com