Loading...
HomeMy WebLinkAboutDosing Design Calculations Revisd 07.21.2026DOSING DESIGN CALCULATIONS, for Mountain Springs Ranch Lot 29, Garfield County, CO 7/13/2026 Step 1: Flows 3 Bedrooms Table 6-1 0 Bedroom (future) 6 assumed people Septic Tank Size: 450 gallons per day 1000 gallons per Table9-1 0.5 average day in gallons per minute 4 doses per day 0.94 peak day in gallons per minute 113 gallons per dose 1.88 peak hour in gallons per minute Step 2: BOD5 6 persons 450 gpd used by residence BOD5 for domestic uses: 0.2 lb/person/day from CDPHE 1.2 lb BOD5/day Step 3: Dosing Basin Third Compartment of Septic Tank 60 inch length 40.5 inch width 16.88 square feet 126.2 gallons per foot of depth depth of dose volume = 0.89 feet of depth in manhole Invert at dosing tank 8132.20 Sump = bottom of third compartment 8128.12 Pump "Off" 1 8129.12 Pump On "Lead" Float 1.89 8130.01 Pump On "Lag" Float 2.39 8130.51 High Alarm (min) 2.89 8131.01 High Alarm (max) in -12" 1.00 8131.20 minutes of run time per dose = 3.2 35 gpm (5 minute rule of thumb) Step 4: Elevations, Orifices, and Head loss Septic Tank Rim Elevation = 8135.5 High Point Elevation = 8122.5 Invert at dosing tank= 8133.2 Sump = 8128.12 Elev Diff = -5.6 feet Length from pump to leach field of 2" = 90 feet Length of 1-1/2" in leach field = 300 feet 2" fittings in equivalent pipe length: 90 90 check 90 gate tee 45 2 - tee 5.2 5.2 17.2 5.2 1.4 10.3 11.2 20.6 76.3 feet Equivalent 2" Length from pump = 160.7 feet from Fig F, using 1.81 ft of friction head per 100' of 2" plastic pipe = 2.9 head loss @ 30 gpm from Fig F, using 0.5 ft of friction head per 100' of 1-1/2" plastic pipe = 1.5 head loss @ 7.5 gpm Dynamic Head (TDH) -1.2 system condition use TDH of 10 feet 1/8 " dia. orifice @ 5' of Head yields 0.45 gpm 4 Laterals 18 orifices per lateral 32.4 gpm Step 5: Velocity verification 35 gpm in 2 inch pipe 0.022 = area 0.078 = flow in cfs 3.575 = velocity in feet per second, must be greater than 2.0 feet per second but less than 10 feet per second 8.75 gpm in 1.5 inch pipe 0.012 = area 0.019 = flow in cfs 1.589 = velocity in feet per second Step 6: Pipe Volume & Drain Back no drain back