Loading...
HomeMy WebLinkAboutOWTS Pump Calcs Revised 07.21.2026Pump Selection for a Pressurized System - Single Family Residence Project Parameters Discharge Assembly Size Transport Length Transport Pipe Class Transport Line Size Distributing Valve Model Max Elevation Lift Manifold Length Manifold Pipe Class Manifold Pipe Size Number of Laterals per Cell Lateral Length Lateral Pipe Class Lateral Pipe Size Orifice Size Orifice Spacing Residual Head Flow Meter 'Add-on' Friction Losses 2.00 90 40 2.00 None 10 12 40 1.50 4 92 40 1.50 1/8 4 5 None 0 inches feet inches feet feet inches feet inches inches feet feet inches feet Calculations Minimum Flow Rate per Orifice Number of Orifices per Zone Total Flow Rate per Zone Number of Laterals per Zone % Flow Differential 1st/Last Orifice Transport Velocity 0.43 96 41.8 4 2.3 4.0 gpm gpm % fps Frictional Head Losses Loss through Discharge Loss in Transport Loss through Valve Loss in Manifold Loss in Laterals Loss through Flowmeter 'Add-on' Friction Losses 3.5 2.6 0.0 0.3 0.3 0.0 0.0 feet feet feet feet feet feet feet Pipe Volumes Vol of Transport Line Vol of Manifold Vol of Laterals per Zone Total Volume 15.7 1.3 38.9 55.9 gals gals gals gals Minimum Pump Requirements Design Flow Rate Total Dynamic Head 41.8 21.7 gpm feet 0 40 80 120 160 0 10 20 30 40 50 60 70 Net Discharge (gpm) PumpData PFSW50 Sewage Pump 1/2HP, 115/230V 1Ø Legend System Curve: Pump Curve: Pump Optimal Range: Operating Point: Design Point: