HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT B LCO-02-26-9668 IRMW LLC NEW COMMERCIAL BUILDING 1058 COUNTY ROAD 100, CARBONDALE IRMW LLC PARCEL 1 Lot: 1AAS PER MINOR SUBDIVISION PLAT RECEPTION NUMBER 893462. This is a Type IIA building. Roof, floor, exterior walls and primary steel are to be protected with one -hour assemblies. 1) THE PROPOSED MONOKOTE FIRE PROTECTION REQUIRES SPECIAL INSPECTIONS. PLEASE PROVIDE THE SPECIAL INSPECTION REPORT AT INSULATION INSPECTION. 2) THE MONOKOTE SYSTEM SUBMITTED REQUIRES IT TO BE INSTALLED DIRECTLY TO THE ROOF DECKING WITH INSULATION ON THE EXTERIOR OF THE ROOF. THE LINER INSULATION SYSTEM IS NOT COMPATIBLE WITH THE FIRE -PROOFING PR(lrll I(-T CI IBK/IIITFF) ATTACHED IS A DRYWALL SYSTEM FROM THE METAL BUILDING MANUFACTURERS ASSOCIATION. THE ROOF ASSEMBLY MAY NEED TO CHANGE TO OBTAIN THE REQUIRED ONE -HOUR ASSEMBLY. 3) GEOTECHNICAL OBSERVATION IS REQUIRED WHEN THE EXCAVATION IS COMPLETE AND WRITTEN VERIFICATION BE SUPPLIED AT FOOTING INSPECTION, 1500 PSF. 4) HANDRAILS ARE REQUIRED ON BOTH SIDES OF THE STAIRS. 5) THE GEOTECH IS TO INSPECT THE ROCK FALL MITIGATION BERM AND SUPPLY A LETTER ACCEPTING THE CONSTRUCTION OF THE BERM. 6) A LOT IMPROVEMENT CERTIFICATE, SEALED BY A COLORADO LICENSED SURVEYOR, IS REQUIRED AT FOUNDATION INSPECTION TO VERIFY STRUCTURE - INCLUDING PROPOSED ROOF OVERHANGS DECKS AND OTHER PROJECTIONS - IS IN COMPLIANCE WITH MINIMUM SETBACKS AND/OP. BUILDING ENVELOPE REQUIREMENTS. 7) THE STAIRS ON THE SOUTH SIDE OF THE BUILDING ARE TO BE RELOCATED. PROVIDE REVISED DRAWINGS FOR REVIEW PRIOR TO CONSTRUCTING THOSE REQUIRED EGRESS STAIRS. 8) PLEASE PROVIDE SPECIAL INSPECTIONS REPORTS TO THE BUILDING DEPARTMENT WELDING BOLTING, AND FIREPROOFING IS MINIMUM. 9) CALL FOR EXTERIOR GYPSUM INSPECTION BEFORE COVERING. EXTERIOR GYPSUM DOES NOT NEED TO BE MUDDED. 10)THE APPROVED PLANS ARE TO BE ON -SITE FOR INSPECTIONS. 11) SANITARY FACILITIES ARE REQUIRED TO BE PROVIDED FOR WORKERS. 12)A LIST OF REQUIRED INSPECTIONS WILL BE ATTACHED TO THE PLANS. THE STATE IS TO PERMIT AND APPROVE THE ELECTRICAL WORK. HTTPS://WWW.COLORADO.GOV/PACIFIC/DORA/DPO ELECTRICAL PLUMBING PE RMITS 13) UNDERGROUND UTILITY LOCATES IS THE RESPONSIBILITY OF THE OWNER OR CONTRACTOR. 811 IS THE COLORADO UTILITY LOCATE HOT LINE. 14) DRAINAGE ACROSS PROPERTY LINES SHALL NOT EXCEED THAT WHICH EXISTED PRIOR TO GRADING. EXCESS OR CONCENTRATED DRAINAGE SHALL BE CONTAINED ON SITE OR DIRECTED TO AN APPROVED DRAINAGE FACILITY. EROSION OF THE GROUND IN THE AREA OF DISCHARGE SHALL BE PREVENTED BY INSTALLATION OF NON -EROSIVE DOWN DRAINS OR OTHER DEVICES. 15)ANY RETAINING WALL OVER 48" TALL REQUIRES TO BE DESIGNED BY A STRUCTURAL OR CIVIL ENGINEER DEPENDING ON THE TYPE OF MATERAIL USED. THE 48" HEIGHT IS MEASURED FROM THE BOTTOM OF THE FOOTING THAT IS BELOW GRADE, NOT THE FACE OF THE WALL. 16)ALL BACKFLOW PREVENTERS ARE REQUIRED TO BE TESTED AND CERTIFIED BY A LICENSED BACKFLOW SPECIALIST AFTER INSTALLATION AND PRIOR TO ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. 17) SEPARATE SIGN PERMITS ARE REQUIRED FOR ANY EXTERNAL SIGNS. PLEASE CONTACT THE COUNTY PLANNER FOR THE APPLICATION. 18) ELECTRICAL CODE COMPLIANCE WILL BE DETERMINED BASED ON FIELD INSPECTIONS PERFORMED BY THE STATE ELECTRICAL INSPECTOR, (303) 869-3458. PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN DOCUMENTATION OF THE INSPECTIONS. 19) COMBUSTIBLE MATERIAL IS LIMITED IN TYPE I AND TYPE II CONSTRUCTION. SEE IBC 603 FOR ALLOWED COMBUSTIBLE MATERIALS. 20)ALL EXTERIOR LIGHTING IS TO BE DOWNCAST AND SHIELDED. 21)SAFETY GLAZING IS NOT DESIGNATED ON THE PLANS. SAFETY GLAZING WILL BE CHECKED DURING THE FRAMING AND FINAL INSPECTION. (IBC 2406.4) 22) ANY MEMBRANE AND THROUGH PENETRATIONS OF THE FIRE RESISTIVE CONSTRUCTION WILL BE REQUIRED TO BE FIRE -STOPPED WITH LISTED FIRE STOPPING ASSEMBLIES. THE CONTRACTOR IS TO PROVIDE A CUT SHEET FOR THE ASSEMBLIES AT THE FRAMING INSPECTION. (IBC 713) 23)A KNOX BOX IS REQUIRED TO BE MOUNTED ADJACENT TO THE FRONT DOOR. PLEASE CONTACT THE LOCAL FIRE DISTRICT FOR EXACT LOCATION. 24)THE WALLS SURROUNDING THE TOILETS ARE TO BE NON -ABSORBENT FOR A HEIGHT OF 48" AND 2' PAST ON EACH SIDE OF THE TOILETS. 25) ALL ACCESSIBLE DOOR HARDWARE SHALL HAVE A SHAPE THAT IS EASY TO GRIP, INCLUDING POCKET AND SLIDING DOORS. (ANSI A117.1 - 404.2.6) 26) GRAB BAR BACKING IS TO BE IN PLACE FOR ALL TOILETS, BATHTUBS AND SHOWERS. 27) UFER GROUNDS ARE REQUIRED TO BE INSPECTED AT FOOTING INSPECTION 28)ANY EXPOSED FOAM IS TO BE COVERED WITH AN IGNITION BARRIER OR A THERMAL BARRIER BASED ON LOCATION. 29) INSTALL STORMWATER CONTROLS PRIOR TO ANY DIRT WORK. 30) LOCATE ALL UTILITIES PRIOR TO ANY WORK. 811 IS THE STATE UTILITY LOCATE NUMBER 31) CONTROL NOXIOUS WEEDS. TREAT EXISTING WEEDS PRIOR TO RELOCATING PLANTS AND SEEDS. 32) PROVIDE EROSION CONTROLS UNTIL SEEDED AREAS CAN BE ESTABLISHED. 33) PROVIDE DUST CONTROL AS REQUIRED DURING CONSTRUCTION. 34) FOLLOW ENGINEERED PLANS. VERIFY ANY CHANGES WITH THE ENGINEER.