HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLRE-12-25-9608
BLUE MIND LLC
TENT STRUCTURE
2340 COUNTY ROAD 100, CARBONDALE
UNHEATED A3 OCCUPANCY - TYPE IIB
1) DO NOT BACKFILL THE CONCRETE BLOCKS UNTIL THE HOLD DOWN ANGLES ARE INSPECTED.
DETAIL 1/S5 ON THE PLANS.
RD OHE STRUCTURE.2) PLEASE PROVIDEA3r;O
3) THE COMPACTED ROAD BASE SHOWN FOR PARKING ACCESSIBLITY AND ACCESSIBLE ROUTE,
THESE ARE TO BE STABLE FIRS," AND SLIP RESISTANT.
4) THE APPROVED PLANS ARE TO BE ON -SITE FOR INSPECTIONS.
5) EXITS ARE SHOWN WITH NO DOORS IF DOORS ARE INSTALLED THEY ARE TO HAVE PANIC
HARDWARE AND SWING OUT.
6) A LOT IMPROVEMENT CERTIFICATE SEALED BY A COLORADO LICENSED SURVEYOR, IS
REQUIRED AT TO VERIFY COMPLIANCE WITH MINIMUM SETBACKS.
7) MAXIMUM OCCUPANT LOAD OF 300 IS TO BE POSTED AT EACH EXIT DOOR
8) MAINTAIN COMPLIANCE WITH ALL CONDITIONS FOR THE LAND USE CHANGE PERMIT
INCLUDING COMPLIANCE WITH CONDITION CONTAINED IN RESOLUTION 2025-45, 2025-53
9) COMPLIANCE WITH CONDITION #2 OF THE LAND USE CHANGE PERMIT "THAT THE UPDATED
PARKING CONFIGURATIONS AND THE STORMWATER DRAINAGE AREA SHALL BE INSTALLED
PRIOR TO THE INSTALLATION OF THE LONG SPAN STRUCTURE."
10)THAT THE USES WITHIN THE LONG SPAN STRUCTURE ARE LIMITED TO PHASE I USES AS
DOCUMENTED IN THE APPLICATION SUBMITTALS ASSOCIATED WITH THE EXISTING HOCKEY
PROGRAM.
11)THAT LIGHTING WITH THE STRUCTURE WILL MAINTAIN COMPLIANCE WITH THE SHUT DOWN OF
ALL LIGHTING PROVISIONS NO LATER THAN 9:00 P.M.
12) SANITARY FACILITIES ARE REQUIRED TO BE PROVIDED FOR WORKERS.
13)A LIST OF REQUIRED INSPECTIONS WILL BE ATTACHED TO THE PLANS. THE STATE IS TO PERMIT
AND APPROVE THE ELECTRICAL WORK.
HTTPS://WWW.COLORADO.GOV/PACIFIC/DORA/DPO ELECTRICAL PLUMBING PERMITS
14) UNDERGROUND UTILITY LOCATES IS THE RESPONSIBILITY OF THE OWNER OR CONTRACTOR.
811 IS THE COLORADO UTILITY LOCATE HOT LINE.
15) DRAINAGE ACROSS PROPERTY LINES SHALL NOT EXCEED THAT WHICH EXISTED PRIOR TO
GRADING. EXCESS OR CONCENTRATED DRAINAGE SHALL BE CONTAINED ON SITE OR
DIRECTED TO AN APPROVED DRAINAGE FACILITY. EROSION OF THE GROUND IN THE AREA OF
DISCHARGE SHALL BE PREVENTED BY INSTALLATION OF NON -EROSIVE DOWN DRAINS OR
OTHER DEVICES.
16) ELECTRICAL CODE COMPLIANCE WILL BE DETERMINED BASED ON FIELD INSPECTIONS
PERFORMED BY THE STATE ELECTRICAL INSPECTOR, (303) 869-3458. PLEASE HAVE THE
INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN DOCUMENTATION OF THE
INSPECTIONS.
17) INSTALL STORMWATER CONTROLS PRIOR TO ANY DIRT WORK.
18) CONTROL NOXIOUS WEEDS. TREAT EXISTING WEEDS PRIOR TO RELOCATING PLANTS AND
SEEDS.
19) PROVIDE DUST CONTROL AS REQUIRED DURING CONSTRUCTION.
20) SEPARATE SIGN PERMITS ARE REQUIRED FOR ANY EXTERNAL SIGNS. PLEASE CONTACT THE
COUNTY PLANNER FOR THE APPLICATION.
21) COMBUSTIBLE MATERIAL IS LIMITED IN TYPE I AND TYPE II CONSTRUCTION. SEE IBC 603 FOR
ALLOWED COMBUSTIBLE MATERIALS.