Loading...
HomeMy WebLinkAboutPlansX XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XO E XO E XO E XO E XO E XO E XO E XO E XO E XO E XO E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E << < < < < < WW W W W W W W W W W W W W W W W W W W W WWWWWWWW W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS XSS XS S XS S UE UE UE UE UE UE UE G G G G G G G G G G G G G UE UE UE UE UE UE UE UE UE UE UE UEGGGGGG G E S S 8829 8830 8832 88 3 4 88 3 0 8 8 3 4 8 8 2 5 88 2 0 8 8 1 5 88 1 0 88 0 5 8 8 0 0 8 7 9 5 88 0 0 88 0 5 88 1 0 881 5 8 8 1 5 88 2 0 8 8 2 5 8 8 2 0 882 5 88 2 7 8828 8828 882 5 881 0 Existing Primitive Access Road Widen And Improve For Vehicular Use Proposed Parking Lot Utility Easement (Typ) (4) Proposed RV Sites Proposed Soil Treatment Area Assumed Wetlands 35' Wetland Setback Existing Primitive Access Road Widen And Improve For Vehicular Use Existing Access Road (4) Proposed RV Sites Widen Existing Access Existing Access Road Existing Access RoadExisting Cabins Existing Soil Treatment Area For Cabins Existing Outbuildings Proposed Primitive Access RV Loop Proposed Onsite Wastewater Treatment System Septic Tanks Existing Lodge Water Treatment Shed Existing Main Entry Gate Fire Truck Pulloff Fire Suppression Tank With Dry Hydrant 882 0 88 1 5 Existing Pond Well Water Treatment Waste Tanks (1) Proposed ADA Compliant RV Site Proposed ADA Parking Space RV Access Parking Space Design Notes 1.The design is based on the best available information. This includes but is not limited to site conditions, features and structures, and topographical information. Crystal River Civil is assuming no responsibility for the accuracy of site information. 2.If any discrepancies or inaccurate information is found within Crystal River Civils' documents, the affected work should be temporarily put on hold. Contact CRC to verify a solution and hold all work until the necessary alterations to drawings have been made. 3.No field changes are to occur without written approval of the engineer. If changes are requested and approved, Crystal River Civil will review the change and respond accordingly. Construction Notes 1.All work completed on this project must meet standards set by the project's jurisdictions. This includes but is not limited to HOA standards, city/town standards, county standards, and/or state standards. 2.The contractor is required to have a copy of current and approved construction plans. Any standards and specifications necessary for the work must be on site for the duration of the project as well. 3.All work must be completed to horizontal and vertical information shown on the plans. If any changes have occurred, Crystal River Civil must verify the alterations prior to receiving approval of completion. 4.If there are known horizontal or vertical discrepancies discovered during construction from the survey data provided to Crystal River Civil, it must be brought to the attention of Crystal River Civil as soon as possible for redesign. All construction must stop before a resolution is made. The contractor is at risk during construction if survey data discrepancies are know. 5.Construction staking of horizontal and vertical layout is the responsibility of the Contractor. If additional documents, site visits for verification, or alterations are necessary, Crystal River Civil can be hired for construction administration for additional services. 6.Property lines, monuments, benchmarks, survey control, and additional historic survey information cannot be removed and cannot be removed for construction. Disturbed survey items are the responsibility of the contractor and must be restored by a state of Colorado licensed land surveyor. 7.Work and storage areas must be maintained only onsite. Project construction in Right-Of-Ways, public space, and private property must be approved in writing by the necessary jurisdiction or individual. 8.Limits of disturbance, tree protection, and slope protection defined within the plans must be met. Disturbances outside of these extents may require alterations to the design and has implications that are the responsibility of the contractor. If damage shall occur outside of these areas, the site conditions shall be restored to their original state. 9.If applicable and a tree removal plan has been developed for the project, it is the responsibility of the contractor to meet the proposed conditions by the approved document. The contractor must not damage, trim, or remove trees and or bushes that are not approved for modification by the tree removal plan. Approval for proceeding with additional tree removal must be approved by Crystal River Civil, the landscape architect, the owner, and/or any stakeholders. 10.The Contractor is responsible for removal of waste created onsite from construction. Waste material that does not meet the requirements for cannot be used for backfilling on the project and must be exported from the site. 11.All materials requiring compaction must meet CDOT and/or ASTM Standards. 12.If traffic control is needed for the project, it is the responsibility of the contractor to obtain and implement an approved traffic control plan. Street access must be provided to the public within the Right-Of-Way - Any obstruction to general traffic flow must be mitigated for. Pedestrian access must be always provided, and traffic entering and leaving the project site is to be observed by the contractor. 13.Dust mitigation must be provided by the contractor as necessary. Water shall be used as a dust palliative where and when required. Sweeping and cleaning streets and sidewalks during the construction will be directed by the affected jurisdictions and performed as necessary by the contractor. Utility Notes 1.Utilities shown on these plans have been located and documented by the surveyor. 2.Existing utilities must be verified on the site prior to construction. The contractor must protect and maintain these existing utilities throughout construction. If any damages occur to existing utility lines, it is the responsibility of the contractor to coordinate with the utility provider replace and repair the utilities as necessary. 3.The contractor must notify the utility providers a minimum of 3 days prior to any work completed. Coordination with the utility providers is the responsibility of the contractor. 4.All utility work completed by the contractor must be installed as per the utility providers' standards and requirements. Inspections must be performed by utility providers as deemed necessary by the corresponding standards. It is the responsibility of the contractor to organize these inspections. 5.If any shallow utilities, including communication and telephone services and lines, are exposed, and temporarily altered for construction, the reinstallation of these utilities must conform with the utility providers standards. 6.Uncovered gas lines must be temporarily contained with 18 inches backfill to minimize exposure. 7.Stormwater infrastructure must pe protected by the contractor as shown in the Erosion Control Plan. During construction, additional stormwater management may be necessary during specific construction procedures and is the responsibility of the contractor. XC XC C C C XFO XFO FO FO << FD FD XG XG G G G XSS XSS SS SS XUE XUE UE UE XOE XOE OE OE XT XT T T T XW XW W W W XWS XWS WS WS Abbreviations: ASTM American Society of Testing and Materials Avg Average Bldg Building BM Benchmark BMP Best Management Practices BOW Bottom of Wall Con Concrete Demo Demolition Dia or Ø Diameter Dim Dimension El or Elev Elevation Ex Existing FFE Finished Floor Elevation FL Flow Line Ft Foot or Feet Gal Gallons Horiz Horizontal Hp High Point Inv Invert LF Linear Feet LP Low Point Max Maximum Min Minimum NTS Not To Scale Off Offset PC Point of Horizontal Tangency PCC Point of Compound Curve Perf Perforated PI Point of Horizontal Tangency Prop Proposed PVC Polyvinyl Chloride Pipe Q Flow Rate RCP Reinforced Concrete Pipe ROW Right-Of-Way SF Square Feet Sta Station SY Square Yard TD Trench Drain Legend Existing Communications Line Proposed Easement Line Edge of Pavement Edge of Gravel Edge of Water Fiber Optic Line Flow Line Foundation Drain Gas Line Gutter Flow Line / Break Line Major Contour Line Minor Contour Line Property Line Sanitary Sewer Line Storm Drain Line Concrete / Sidewalk / Patio Underground Electric Line Overhead Electric Line Telephone Line Water Line Water Service Line TOW Top of Wall XRW XRW RW RWRaw Water Line TBC Top Back Of Curb Drawing Scale Units (Feet) 1" = 50' 0 50 100 N S W E C.01 Title And Notes Of 10 Pages 01 La n d U s e A p p l i c a t i o n 03 . 0 2 . 2 0 2 6 JK E # De s c r i p t i o n Da t e Dr a w n B y 7W R a n c h 34 1 2 C o u n t y R o a d 1 5 1 Gy p s u m , C o l o r a d o 8 1 6 3 7 1101 Village Road, Unit UL-3C Carbondale, CO 81623 (970) 510 - 5312 VJ T Re v i e w e d B y For Construction Job #: 26.09 02 Co m m e n t R e s p o n s e s 06 . 1 6 . 2 0 2 6 JK E VJ T 03 Pe r m i t S e t 08 . 0 6 . 2 0 2 6 JK E VJ T 04 Co m m e n t R e s p o n s e s 09 . 2 5 . 2 0 2 6 JK E VJ T 7W Ranch 3412 County Road Gypsum, Colorado 81637 SITE Vicinity Map Not To Scale Sheet List Table Sheet Number Sheet Title C.01 Title And Notes C.02 Civil Site Plan C.03 Domestic Water Plan C.04 OWTS Site Analysis C.05 OWTS Plan C.06 Electrical Plan C.07 Road Improvements Plan And Profile C.08 RV Loop Plan And Profile C.08 Construction Details C.10 OWTS Details XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XO E XO E XO E XO E XO E XO E XO E XO E XO E XO E XO E XO E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E < <<< < <<< < < < < < < < < < < << WW W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W WWWWWWWWWWWWWWWWWWW W W W W W W W W W W W SS SS SS SS SS SS SS SS SS W W W W SS SSSSSS S S SSSS S S SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G UE G UE G U E G UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE G G G G G G G G G G G G G G G G G G G UE G UE G UE G E UE SS SS SS SSSS 88 3 0 8 8 2 9 88 2 8 88 2 7 88 2 6 88 2 5 88 2 4 88 2 3 88 2 2 88 2 1 88 2 0 88 1 9 88 1 8 88 1 8 88 1 7 88 1 6 88 1 5 88 1 4 88 1 3 88 1 1 88 1 0 88 0 9 88 0 8 88 0 7 88 0 5 88 0 4 88 0 3 88 0 2 882 7 88 2 6 88 2 2 88 2 1 88 2 0 88 1 9 88 1 8 88 1 7 88 1 6 88 1 5 88 1 4 88 1 3 88 1 2 88 1 1 88 1 0 88 0 9 88 0 8 88 0 7 8807 8808 8809 8810 8811 8812 881 3 881 4 88 1 5 88 1 6 88 1 7 88 1 8 88 1 9 88 2 0 88 2 1 88 2 2 88 2 3 8 8 2 4 8 8 2 4 8 8 2 5 8825 8823 88 2 8 8 8 2 8 8 8 2 7 8 8 2 6 8 8 2 5 8 8 2 4 8 8 2 2 8 8 2 3 8 8 2 1 8 8 2 0 8 8 1 9 8 8 1 7 8 8 1 4 8829 8830 8832 88 2 0 8 8 1 5 88 1 0 88 0 5 8 8 0 0 8 7 9 5 88 0 0 88 0 5 88 1 0 881 5 8 8 1 5 88 2 0 8 8 2 5 8 8 2 0 882 5 88 2 7 8828 8828 882 5 881 0 10 3 . 2 0 Existing Access Road Widen And Improve For Vehicular Use Proposed Parking Lot Existing Well Utility Easement (Typ) (4) Proposed RV Sites Proposed Onsite Wastewater Treatment System (OWTS) Septic Tanks Proposed Soil Treatment Area Domestic Water Line Loop Existing Tack Barn Existing Shed 35' Wetland Setback Existing Access Road Widen And Improve For Vehicular Use Maintain Southern Edge Of Road To Minimize Impact To Wetlands Area Existing Access Road Riprap Below Proposed Culvert Proposed 12" ADS Culvert Proposed 12" ADS Culverts Proposed 12" ADS Culvert Proposed Flow Line (Typ) (4) Proposed RV Sites Sanitary Sewer Collection System Widen Existing Access 12.0 0 8X10' Water Treatment Shed 882 0 Fire Truck Pulloff 10'X50' Road Base Surface Not to Exceed 6% Slope Next To Existing Access 5,000 Gallon Fire Suppression System With Dry Hydrant 500 Gallon Concrete Residual Waste Evaporation Tank 1060 Gallon Poly Brine Waste Storage Tank ADA Compliant Parking Space ADA Compliant Walkway (1) Proposed ADA RV Site With ADA Ramp RV Access Parking Space Drawing Scale Units (Feet) 1" = 20' 0 20 40 N S W E C.02 Civil Site Plan Of 10 Pages 01 La n d U s e A p p l i c a t i o n 03 . 0 2 . 2 0 2 6 JK E # De s c r i p t i o n Da t e Dr a w n B y 7W R a n c h 34 1 2 C o u n t y R o a d 1 5 1 Gy p s u m , C o l o r a d o 8 1 6 3 7 1101 Village Road, Unit UL-3C Carbondale, CO 81623 (970) 510 - 5312 VJ T Re v i e w e d B y For Construction Job #: 26.09 02 Co m m e n t R e s p o n s e s 06 . 1 6 . 2 0 2 6 JK E VJ T 03 Pe r m i t S e t 08 . 0 6 . 2 0 2 6 JK E VJ T 04 Co m m e n t R e s p o n s e s 09 . 2 5 . 2 0 2 6 JK E VJ T XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XO E XO E XO E XO E XO E XO E XO E XO E XO E XO E XO E XO E XO E XO E XO E XO E XO E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E < <<< < <<< < < < < < < < < < < << WW W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W WWWWWWWWWWWWWWWWWWW W W W W W W W W W W W SS SS SS SS SS SS SS SS SS W W W W S S SSSSSS SSSSSS S S SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS XSS XS S XS S XS S XSS XS S XS S XS S UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G UE G UE G U E G UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE G G G G G G G G G G G G G G G G G G G UE G UE G UE G E UE SS SS SS SSSS 88 3 0 8 8 2 9 88 2 8 88 2 7 88 2 6 88 2 5 88 2 4 88 2 3 88 2 2 88 2 1 88 2 0 88 1 9 88 1 8 88 1 8 88 1 7 88 1 6 88 1 5 88 1 4 88 1 3 88 1 1 88 1 0 88 0 9 88 0 8 88 0 7 88 0 5 88 0 4 88 0 3 88 0 2 882 7 88 2 6 88 2 2 88 2 1 88 2 0 88 1 9 88 1 8 88 1 7 88 1 6 88 1 5 88 1 4 88 1 3 88 1 2 88 1 1 88 1 0 88 0 9 88 0 8 88 0 7 8807 8808 8809 8810 8811 8812 881 3 881 4 88 1 5 88 1 6 88 1 7 88 1 8 88 1 9 88 2 0 88 2 1 88 2 2 88 2 3 8 8 2 4 8 8 2 4 8 8 2 5 8825 8823 88 2 8 8 8 2 8 8 8 2 7 8 8 2 6 8 8 2 5 8 8 2 4 8 8 2 2 8 8 2 3 8 8 2 1 8 8 2 0 8 8 1 9 8 8 1 7 8 8 1 4 8829 8830 8832 88 3 4 8 8 3 4 88 2 0 8 8 1 5 88 1 0 88 0 5 8 8 0 0 8 7 9 5 88 0 0 88 0 5 88 1 0 881 5 8 8 1 5 88 2 0 8 8 2 5 8 8 2 0 882 5 882 7 8828 8828 882 5 881 0 Existing Soil Treatment Area Install Permanent Fence Around Perimeter To Protect Existing Access Road Widen And Improve For Vehicular Use Proposed Parking Lot Utility Easement (Typ) (4) Proposed RV Sites Proposed Soil Treatment Area Existing Tack Barn Existing Shed Assumed Wetlands 35' Wetland Setback Existing Access Road Widen And Improve For Vehicular Use Existing Access Road (4) Proposed RV Sites Widen Existing Access Proposed Water Line Loop 814 Linear Feet Of 2" PEX Existing Well To Be Utilized Extend Water Service To Each RV Site (Typ) 3 4" Pex To Yard Hydrant For RV Connection 2" To 3 4" PEX Tee To Extend Water Service To Each RV Site Note: 10' Minimum Separation To Be Maintained Between Domestic Water And Sanitary Lines Extend Water Service To Each RV Site (Typ) 3 4" Pex To Yard Hydrant For RV Connection 2" To 3 4" PEX Tee (Typ) To Extend Water Service To Each RV Site 2" PEX Tee To Extend Water Service To Stub Out Proposed Water Line Extension For Future Use 66 Linear Feet Of 2" PEX Install Yard Hydrant At Stub Out For Future Use 8X10' Water Treatment Shed 882 0 500 Gallon Concrete Residual Waste Evaporation Tank 1060 Gallon Poly Brine Waste Storage Tank Water Treatment Waste Lines 2" SDR-26 Sloped @ Min. 2.0% Min. 4' Of Cover. Do Not Tie Waste Lines Into OWTS (1) Proposed ADA RV Site With ADA Ramp Drawing Scale Units (Feet) 1" = 20' 0 20 40 N S W E C.03 Domestic Water Plan Of 10 Pages 01 La n d U s e A p p l i c a t i o n 03 . 0 2 . 2 0 2 6 JK E # De s c r i p t i o n Da t e Dr a w n B y 7W R a n c h 34 1 2 C o u n t y R o a d 1 5 1 Gy p s u m , C o l o r a d o 8 1 6 3 7 1101 Village Road, Unit UL-3C Carbondale, CO 81623 (970) 510 - 5312 VJ T Re v i e w e d B y For Construction Job #: 26.09 02 Co m m e n t R e s p o n s e s 06 . 1 6 . 2 0 2 6 JK E VJ T 03 Pe r m i t S e t 08 . 0 6 . 2 0 2 6 JK E VJ T 04 Co m m e n t R e s p o n s e s 09 . 2 5 . 2 0 2 6 JK E VJ T XW XW XW XW XW XW XW XW XW XW XW XW XW XW XW X X X X << << < WW W W W W W W W W W W W W W W W W WWWWWW W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W SS SS SS SS SS SS SS SSSSSS SS SS SS XS S XSS XS S XS S XS S X S S XS S X S S X S S X S S X S S XSSXSS XSS SS OC OC SS 8829 8830 8832 88 3 4 88 3 0 8 8 3 4 8 8 2 5 88 2 0 8 8 1 5 88 1 0 88 0 5 8 8 0 0 8 7 9 5 88 0 0 88 0 5 88 1 0 881 5 8 8 1 5 88 2 0 8 8 2 5 8 8 2 0 882 5 88 2 7 8828 8828 882 5 881 0 Assumed Wetlands Area 35' Wetlands Setback Proposed RV Sites (Typ) Utility Easements(Typ) Well OWTS Permit # 9315 Soil Treatment Area Permitted In 2025 For 3-Bedroom House for 450 GPD With 44 Quick-4 Infiltrators (Services Ranch Manager's House) Permit # 9315 Soil Treatment Area 74' Horizontal Influence Area OWTS Permit # 1507 Soil Treatment Area Permitted In 1986 For 2, 1-Bedroom Cabins for 150 GPD (Services Guest Cabin #4 and #5) Permit # 1507 Soil Treatment Area 38' Horizontal Influence Area OWTS Permit # 2248 Soil Treatment Area Permitted In 1994 For 3, 1-Bedroom Cabins for 200 GPD (Services Guest Cabins #1, #2, and #3) Permit # 2248 Soil Treatment Area 34' Horizontal Influence Area OWTS Permit # 3828 Soil Treatment Area Permitted In 2005 For 1 2 Bath and Sink In Barn Estimated at 90 GPD Permit # 3828 Soil Treatment Area 31' Horizontal Influence Area OWTS Permit # 1534 Soil Treatment Areas Permitted In 1987 For 1928 GPD (Services Dining Lodge, Employee House, and Guest Cabin #6) Permit # 1534 Soil Treatment Area 251' Horizontal Influence Area Proposed OWTS Soil Treatment Area To Be Permitted For 2,000 GPD Proposed Soil Treatment Area 260' Horizontal Influence Area Mills Spring Water Source Case # 87CW240 Existing Pond Riland Creek Estimated Stream Location Barn Employee House Recreation Room Guest Cabin #6 Guest Cabin #1 Guest Cabin #2 Guest Cabin #3 Guest Cabin #4 Guest Cabin #5 Dining Lodge Proposed Parking Lot Ranch Manager's House Well 180' Setback 100' Well Setback Permit #166915 180' Setback 100' Setback 50' Wetlands Setback Riland Creek 50' Stream Setback Line Pond 50' Setback Line 882 0 881 5 8 8 8 5 8880 887 5 887 0 886 5 8860 8 8 5 5 88 5 5 88 6 0 88 6 5 8 8 7 0 8 8 7 5 8 8 8 0 Drawing Scale Units (Feet) 1" = 60' 0 60 120 N S W E C.04 OWTS Site Analysis Of 10 Pages 01 La n d U s e A p p l i c a t i o n 03 . 0 2 . 2 0 2 6 JK E # De s c r i p t i o n Da t e Dr a w n B y 7W R a n c h 34 1 2 C o u n t y R o a d 1 5 1 Gy p s u m , C o l o r a d o 8 1 6 3 7 1101 Village Road, Unit UL-3C Carbondale, CO 81623 (970) 510 - 5312 VJ T Re v i e w e d B y For Construction Job #: 26.09 02 Co m m e n t R e s p o n s e s 06 . 1 6 . 2 0 2 6 JK E VJ T 03 Pe r m i t S e t 08 . 0 6 . 2 0 2 6 JK E VJ T 04 Co m m e n t R e s p o n s e s 09 . 2 5 . 2 0 2 6 JK E VJ T Note: Soil Treatment Area Horizontal Influence Area Determined Following The Procedures Described In CDPHE's Policy 6 XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XO E XO E XO E XO E XO E XO E XO E XO E XO E XO E XO E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E < <<< < <<< < < < < < < < < < < << WW W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W WWWWWWWWWWWWWWWWWWW W W W W W W W W W W W SS SS SS SS SS SS SS SS SS W W W W SS SSSSSS SSSS S S S S SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G UE G UE G U E G UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE G G G G G G G G G G G G G G G G G G G UE G UE G UE G E UE SS SS S S SSSS 88 3 0 8 8 2 9 88 2 8 88 2 7 88 2 6 88 2 5 88 2 4 88 2 3 88 2 2 88 2 1 88 2 0 88 1 9 88 1 8 88 1 8 88 1 7 88 1 6 88 1 5 88 1 4 88 1 3 88 1 1 88 1 0 88 0 9 88 0 8 88 0 7 88 0 5 88 0 4 88 0 3 88 0 2 882 7 88 2 6 88 2 2 88 2 1 88 2 0 88 1 9 88 1 8 88 1 7 88 1 6 88 1 5 88 1 4 88 1 3 88 1 2 88 1 1 88 1 0 88 0 9 88 0 8 88 0 7 8807 8808 8809 8810 8811 8812 881 3 881 4 88 1 5 88 1 6 88 1 7 88 1 8 88 1 9 88 2 0 88 2 1 88 2 2 88 2 3 8 8 2 4 8 8 2 4 8 8 2 5 8825 8823 88 2 8 8 8 2 8 8 8 2 7 8 8 2 6 8 8 2 5 8 8 2 4 8 8 2 2 8 8 2 3 8 8 2 1 8 8 2 0 8 8 1 9 8 8 1 7 8 8 1 4 8829 8830 88 2 0 8 8 1 5 88 1 0 88 0 5 8 8 0 0 8 7 9 5 88 0 0 88 0 5 88 1 0 881 5 8 8 1 5 88 2 0 8 8 2 5 8 8 2 0 882 5 882 7 8828 8828 882 5 881 0 Existing Access Road Widen And Improve For Vehicular Use Proposed Parking Lot Utility Easement (Typ) (4) Proposed RV Sites Proposed Soil Treatment Area Existing Tack Barn Existing Shed 35' Wetland Setback Existing Access Road Widen And Improve For Vehicular Use Existing Access Road (4) Proposed RV Sites Widen Existing Access Extend Sewer Service To Each RV Site (Typ) Utilize RV Sewer Connection For Each Unit Shared Sewer Line 6" SCH-40 @ Min. 2% Maintain 4.5' Min. Of Cover RV Site Sewer Service (Typ) 4" SCH-40 @ Min. 2% Maintain 4' Of Cover Install Cleanout At Every Pipe Bend Or Every 100' (2) 1,500 Gallon Single Compartment Septic Tanks Min. 1' and Max 4' Of Cover Over Tank Install Risers For Manhole Access To Be Flush With Finish Grade Distribution Box (D-Box), Install Bottom Of D-Box Level And Risers For Lid To Be Flush With Finish Grade. Inv. In: 8806.16 Inv. Out: 8806.00 4" SCH-40 Manifolds For Equal Distribution, Tie Effluent Pipe To As Near To The Middle Of The Distribution Header As Possible. Offset From Any Distribution Lateral So As To Not Provide A Direct Pathway Into A Single Lateral. Well 279' From Proposed Soil Treatment Area Note: Maintain 10 Separation Between Sanitary and Domestic Water Lines Consists of (7) 12'x100' Gravity Fed Beds Sized For 2,000 Gallons Per Day. Configuration Uses 700 Quick 4 Standard Chambers For Effluent Distribution over 8400 Square Feet. Distribution Piping Terminates At Chamber End Cap With Splash Plate To Prevent Erosion. System Was Sized Utilizing An LTAR Of 0.2 And Infiltrators For A Distribution Media Reduction. Maintain Max 4' Of Cover Over System. Refer To The OWTS Report For Additional Information. Existing OWTS Install 6" Sewer Stub Out For Future Use. Inv.: 8817.50 1 0 0 . 0 0 120.00 8X10' Water Treatment Shed 882 0 881 5 500 Gallon Concrete Residual Waste Evaporation Tank 1060 Gallon Poly Brine Waste Storage Tank Inv. In: 8806.75 Inv. Out: 8806.50 Inv. In: 8806.45 Inv. Out: 8806.20 6" 45° Pipe Bend With Cleanout Inv.: 8813.04 6" 45° Pipe Bend With Cleanout Inv.: 8809.77 6" 45° Pipe Bend With Cleanout Inv.: 8808.98 6" 45° Pipe Bend With Wye and Cleanout Inv.: 8808.98 Tie Into Shared Sewer Line Inv.: 8820.50 Inv. Out: 8805.85 Inv. Out: 8805.46 Inv. Out: 8805.10 Inv. Out: 8804.74 Inv. Out: 8804.38 Inv. Out: 8804.02 Inv. Out: 8803.63 Install Inspection Port At The Corners Of All Beds (28 total) (Typ) Do Not Connect Water Treatment Waste Management to Proposed OWTS (7) Transport Lines From Distribution Box To Manifolds 4" Sch-40 @ Min. 2.00% (1) Proposed ADA RV Site With ADA Ramp Drawing Scale Units (Feet) 1" = 20' 0 20 40 N S W E C.05 OWTS Plan Of 10 Pages 01 La n d U s e A p p l i c a t i o n 03 . 0 2 . 2 0 2 6 JK E # De s c r i p t i o n Da t e Dr a w n B y 7W R a n c h 34 1 2 C o u n t y R o a d 1 5 1 Gy p s u m , C o l o r a d o 8 1 6 3 7 1101 Village Road, Unit UL-3C Carbondale, CO 81623 (970) 510 - 5312 VJ T Re v i e w e d B y For Construction Job #: 26.09 02 Co m m e n t R e s p o n s e s 06 . 1 6 . 2 0 2 6 JK E VJ T 03 Pe r m i t S e t 08 . 0 6 . 2 0 2 6 JK E VJ T 04 Co m m e n t R e s p o n s e s 09 . 2 5 . 2 0 2 6 JK E VJ T XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XO E XO E XO E XO E XO E XO E XO E XO E XO E XO E XO E XO E XO E XO E XO E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E < <<< < <<< < < < < < < < < < < << WW W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W WWWWWWWWWWWWWWWWWWW W W W W W W W W W W W SS SS SS SS SS SS SS SS SS W W W W S S SSSSSS SSSSSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS XSS XS S XS S XS S UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G UE G UE G U E G UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE G G G G G G G G G G G G G G G G G G G UE G UE G UE G E UE SS SS SS SSSS 88 3 0 88 2 9 88 2 8 88 2 7 88 2 6 88 2 5 88 2 4 88 2 3 88 2 2 88 2 1 88 2 0 88 1 9 88 1 8 88 1 8 88 1 7 88 1 6 88 1 5 88 1 4 88 1 3 88 1 1 88 1 0 88 0 9 88 0 8 88 0 7 88 0 5 88 0 4 88 0 3 88 0 2 882 7 88 2 6 88 2 2 88 2 1 88 2 0 88 1 9 88 1 8 88 1 7 88 1 6 88 1 5 88 1 4 88 1 3 88 1 2 88 1 1 88 1 0 88 0 9 88 0 8 88 0 7 8807 8808 8809 8810 8811 8812 881 3 881 4 88 1 5 88 1 6 88 1 7 88 1 8 88 1 9 88 2 0 88 2 1 88 2 2 88 2 3 8 8 2 4 8 8 2 4 8 8 2 5 8825 8823 88 2 8 8 8 2 8 8 8 2 7 8 8 2 6 8 8 2 5 8 8 2 4 8 8 2 2 8 8 2 3 8 8 2 1 8 8 2 0 8 8 1 9 8 8 1 7 8 8 1 4 8829 8830 8832 88 3 4 88 2 0 8 8 1 5 88 1 0 88 0 5 8 8 0 0 8 7 9 5 88 0 0 88 0 5 88 1 0 881 5 8 8 1 5 88 2 0 8 8 2 5 8 8 2 0 882 5 88 2 7 8828 8828 882 5 881 0 Existing Soil Treatment Area Install Permanent Fence Around Perimeter To Protect Existing Access Road Widen And Improve For Vehicular Use Proposed Parking Lot Utility Easement (Typ) (4) Proposed RV Sites Proposed Soil Treatment Area Existing Tack Barn Existing Shed Assumed Wetlands 35' Wetland Setback Existing Access Road Widen And Improve For Vehicular Use Existing Access Road (4) Proposed RV Sites Widen Existing Access Install Pad Mounted Transformer At Base Of Powerline Pole Extend Primary Power From Overhead Electric to Proposed Transformer Extend (5) Secondary Electric Service Conduit From Breaker Box To RV Pads Extend (4) Secondary Electric Service Conduit From Breaker Box TO RV Pads Extend Secondary Electric Service Conduit From Breaker Box To Future Use Tie-In Install Remote Meter, Shutoff, And Breaker Box Next To Transformer Extend Electric To Well For Well Pump And Water Treatment System 8X10' Water Treatment Shed 882 0 500 Gallon Concrete Residual Waste Evaporation Tank 1060 Gallon Poly Brine Waste Storage Tank Install (1) 1,500 Gallon Underground Propane Tank Extend Shared Propane Lines From Propane Tank TO RV Pads (1) Proposed ADA RV Site With ADA Ramp Drawing Scale Units (Feet) 1" = 20' 0 20 40 N S W E C.06 Electrical And Propane Plan Of 10 Pages 01 La n d U s e A p p l i c a t i o n 03 . 0 2 . 2 0 2 6 JK E # De s c r i p t i o n Da t e Dr a w n B y 7W R a n c h 34 1 2 C o u n t y R o a d 1 5 1 Gy p s u m , C o l o r a d o 8 1 6 3 7 1101 Village Road, Unit UL-3C Carbondale, CO 81623 (970) 510 - 5312 VJ T Re v i e w e d B y For Construction Job #: 26.09 02 Co m m e n t R e s p o n s e s 06 . 1 6 . 2 0 2 6 JK E VJ T 03 Pe r m i t S e t 08 . 0 6 . 2 0 2 6 JK E VJ T 04 Co m m e n t R e s p o n s e s 09 . 2 5 . 2 0 2 6 JK E VJ T XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XO E XO E XO E XO E XO E XO E XO E XO E XO E XO E XO E XO E XO E XO E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E < <<< < <<< < < < < < < < < < < << WW W W W W W W W W W W W W W W W W W W W W WWWWWWWWWWWWWWWWWWW W W W W W W W W W W W SS SS SS SS SS SS SS SS SS W S S S S S S SS S S SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W XSS UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G UE G UE G U E G UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE G G G G G G G G G G G G G G G G G G G UE G UE G UE G E UE SS SS SS SSSS 100 00 10 1 00 1 0 2 0 0 10 3 00 10 4 00 10 5 00 105 27 PC: 102+36.42 PC: 101+71.70 PC: 103+11.02 PC: 103+57.57 PC: 104+62.29PT: 102+66.90 PT: 102+06.39 PT: 103+40.10 PT: 104+37.78 PT: 104+78.17 Start Road Improvement Alignment STA:100+00.00 N:2687.75 E:1599.30 End Road Improvement Alignment STA:105+26.66 N:2719.22 E:2121.91 88 3 0 88 2 9 88 2 8 88 2 7 88 2 6 88 2 5 88 2 4 88 2 3 88 2 2 88 2 1 88 2 0 88 1 9 88 1 8 88 1 8 88 1 7 88 1 6 88 1 5 88 1 4 88 1 3 88 1 1 88 1 0 88 0 9 88 0 8 88 0 7 88 0 5 88 0 4 88 0 3 88 0 2 882 7 88 2 6 88 2 2 88 2 1 88 2 0 88 1 9 88 1 8 88 1 7 88 1 6 88 1 5 88 1 4 88 1 3 88 1 2 88 1 1 88 1 0 88 0 9 88 0 8 88 0 7 8807 8808 8809 8810 8811 8812 881 3 881 4 88 1 5 88 1 6 88 1 7 88 1 8 88 1 9 88 2 0 88 2 1 88 2 2 88 2 3 8 8 2 4 8 8 2 4 8 8 2 5 8825 8823 88 2 8 8 8 2 8 8 8 2 7 8829 8830 8832 88 2 0 8 8 1 5 88 1 0 88 0 5 8 8 0 0 8 7 9 5 88 0 0 88 0 5 88 1 0 881 5 8 8 1 5 88 2 0 8 8 2 5 8 8 2 0 882 5 88 2 7 8828 Existing Soil Treatment Area Install Permanent Fence Around Perimeter To Protect Existing Access Road Widen And Improve For Vehicular Use Proposed Parking Lot Utility Easement (Typ) Existing Tack Barn Existing Shed Assumed Wetlands 35' Wetland Setback Existing Access Road Widen And Improve For Vehicular Use Existing Access Road (4) Proposed RV Sites Widen Existing Access L1 L2 L3 L4 L5 L6C1 C2 C3 C4 C5 10 . 0 0 20.00 Typical Parking Space 19 Spaces Within Parking Lot Sta:101+23.71 Off:34.25'L Elev:8828.01 Sta:101+43.68 Off:33.20'L Elev:8827.45 Sta:101+48.41 Off:27.94'L Elev:8827.44 Sta:101+48.11 Off:22.21'L Elev:8827.48Sta:101+33.13 Off:8.00'L Elev:8828.18 Sta:101+26.86 Off:94.17'L Elev:8828.01 Sta:101+42.84 Off:93.33'L Elev:8827.69 Sta:101+53.35 Off:102.79'L Elev:8827.64 Sta:101+54.19 Off:118.77'L Elev:8827.88 Sta:102+40.50 Off:103.94'L Elev:8827.15 Sta:102+37.65 Off:84.93'L Elev:8826.75 Sta:102+33.73 Off:69.78'L Elev:8826.43 Sta:102+38.39 Off:57.05'L Elev:8825.93 Sta:102+47.56 Off:52.94'L Elev:8825.45 Sta:102+25.98 Off:30.09'L Elev:8825.45 Sta:102+42.91 Off:23.72'L Elev:8824.85 Sta:102+19.72 Off:27.37'L Elev:8825.51 Sta:102+19.42 Off:26.54'L Elev:8825.49 Sta:102+41.39 Off:9.68'L Elev:8822.71 Sta:101+69.64 Off:31.83'L Elev:8826.69 Sta:101+95.48 Off:29.00'L Elev:8826.06 Sta:100+07.20 Off:8.00'L Elev:8828.61 Sta:100+19.55 Off:6.04'L Elev:8828.96 Sta:100+49.12 Off:4.48'L Elev:8829.65 Sta:100+77.27 Off:4.87'L Elev:8830.06 10 1 . 3 8 1 3 . 1 4 15.00 26.00 26 . 0 0 26.00 Sta:102+65.30 Off:21.72'L Elev:8823.09 Sta:102+73.08 Off:6.00'L Elev:8821.22 Inv. Out Sta:102+69.64 Off:8.29'L Elev:8820.97 Inv. In Sta:102+41.26 Off:12.44'L Elev:8822.00 12" ADS Culverts 12" ADS Culverts 12" ADS Culverts R 1 0 . 0 0 R15 . 0 0 R15 . 0 0 R10.00 Sta:104+85.84 Off:6.00'L Elev:8802.78 Sta:104+67.99 Off:29.13'L Elev:8807.19 Sta:105+07.30 Off:26.19'L Elev:8802.00 Sta:105+04.21 Off:15.25'L Elev:8801.98 Sta:104+81.34 Off:18.75'L Elev:8804.95 Sta:104+95.78 Off:6.00'L Elev:8801.69 Sta:105+07.42 Off:3.65'L Elev:8800.01 Sta:105+04.57 Off:6.00'R Elev:8799.98 Inv. Out Sta:103+26.68 Off:8.03'L Elev:8817.65 Inv. In Sta:103+20.84 Off:8.00'L Elev:8818.08 Inv. Out Sta:104+07.45 Off:8.02'L Elev:8810.89 Inv. In Sta:103+97.67 Off:7.99'L Elev:8811.92 12 . 0 0 Sta:100+77.15 Off:8.00'R Elev:8830.21 R 4 4 . 0 0 R20. 0 0 8X10' Water Treatment Shed 500 Gallon Concrete Residual Waste Evaporation Tank 1060 Gallon Poly Brine Waste Storage Tank Maintain Existing Edge Of Road Along South Side Of Road Nearest To Wetlands Area Start Access Sta:100+77.22 Elev:8830.16 End Access Sta:105+06.34 Inv. In Sta:104+52.52 Off:22.32'L Elev:8806.00 2.0% 2 . 5 % 3. 6 % 2.0% ADA Parking Space RV Access Parking Space Road Improvement Alignment Profile Horizontal Scale: 1"=20' Vertical Scale: 1"=20' 8795 8800 8810 8820 8830 8795 8800 8810 8820 8830 100+20 EG 8 8 2 9 . 3 F G 8 8 2 9 . 3 1 100+40 EG 8 8 2 9 . 6 F G 8 8 2 9 . 7 1 100+60 EG 8 8 3 0 . 0 F G 8 8 3 0 . 0 9 100+80 EG 8 8 3 0 . 1 F G 8 8 3 0 . 1 3 101+00 EG 8 8 2 9 . 7 F G 8 8 2 9 . 6 7 101+20 EG 8 8 2 8 . 8 F G 8 8 2 8 . 7 6 101+40 EG 8 8 2 7 . 9 F G 8 8 2 7 . 7 6 101+60 EG 8 8 2 6 . 7 F G 8 8 2 6 . 7 6 101+80 EG 8 8 2 5 . 3 F G 8 8 2 5 . 7 6 102+00 EG 8 8 2 4 . 3 F G 8 8 2 4 . 7 6 102+20 EG 8 8 2 3 . 9 F G 8 8 2 3 . 7 6 102+40 EG 8 8 2 3 . 3 F G 8 8 2 2 . 7 5 102+60 EG 8 8 2 2 . 4 F G 8 8 2 1 . 7 5 102+80 EG 8 8 2 1 . 1 F G 8 8 2 0 . 7 5 103+00 EG 8 8 1 9 . 7 F G 8 8 1 9 . 7 5 103+20 EG 8 8 1 8 . 7 F G 8 8 1 8 . 6 1 103+40 EG 8 8 1 7 . 4 F G 8 8 1 7 . 2 7 103+60 EG 8 8 1 5 . 6 F G 8 8 1 5 . 7 3 103+80 EG 8 8 1 3 . 7 F G 8 8 1 3 . 9 9 104+00 EG 8 8 1 1 . 9 F G 8 8 1 2 . 0 5 104+20 EG 8 8 0 9 . 7 F G 8 8 0 9 . 9 1 104+40 EG 8 8 0 7 . 7 F G 8 8 0 7 . 7 1 104+60 EG 8 8 0 5 . 5 F G 8 8 0 5 . 5 1 104+80 EG 8 8 0 3 . 0 F G 8 8 0 3 . 3 1 105+00 EG 8 8 0 0 . 9 F G 8 8 0 1 . 1 1 105+20 EG 8 7 9 8 . 9 F G 8 7 9 8 . 9 1 2.00% -5.00% -11.00% Start Access Improvements STA = 100+00.00 ELEV = 8828.907 End Access Improvements STA = 105+26.40 ELEV = 8798.202 PVI STA: 100+83.60 PVI ELEV: 8830.58 K: 8.00 LVC: 56.02 BV C S : 1 0 0 + 5 5 . 5 9 BV C E : 8 8 3 0 . 0 2 EV C S : 1 0 1 + 1 1 . 6 1 EV C E : 8 8 2 9 . 1 8 HIGH PT. STA: 100+71.59 HIGH PT ELEV: 8830.18 PVI STA: 103+55.98 PVI ELEV: 8816.95 K: 20.00 LVC: 120.00 BV C S : 1 0 2 + 9 5 . 9 8 BV C E : 8 8 1 9 . 9 5 EV C S : 1 0 4 + 1 5 . 9 9 EV C E : 8 8 1 0 . 3 5 Line Table Line L1 L2 L3 L4 L5 L6 Bearing N86°59'13"E N70°25'22"E S87°45'09"E S83°35'13"E N82°16'25"E N88°20'10"E Length 171.70' 30.03' 44.12' 17.48' 24.52' 48.49' Start Point (N,E) 2687.75,1599.30 2703.55,1804.66 2718.18,1862.90 2714.25,1935.98 2713.22,2033.34 2717.81,2073.44 End Point (N,E) 2696.78,1770.76 2713.61,1832.96 2716.45,1906.98 2712.30,1953.34 2716.51,2057.63 2719.22,2121.91 Curve Table Curve C1 C2 C3 C4 C5 Radius 80.00' 120.00' 400.00' 325.00' 150.00' Length 30.47' 34.69' 29.08' 80.20' 15.87' Tangent 15.42' 17.47' 14.55' 40.31' 7.94' Chord 30.29' 34.57' 29.07' 80.00' 15.86' Bearing N81°20'07"E N78°42'18"E S85°40'11"E N89°20'36"E N85°18'17"E Delta 21° 49' 29" 16° 33' 50" 4° 09' 56" 14° 08' 22" 6° 03' 45" Drawing Scale Units (Feet) 1" = 20' 0 20 40 N S W E C.07 Road Improvements Plan And Profile Of 10 Pages 01 La n d U s e A p p l i c a t i o n 03 . 0 2 . 2 0 2 6 JK E # De s c r i p t i o n Da t e Dr a w n B y 7W R a n c h 34 1 2 C o u n t y R o a d 1 5 1 Gy p s u m , C o l o r a d o 8 1 6 3 7 1101 Village Road, Unit UL-3C Carbondale, CO 81623 (970) 510 - 5312 VJ T Re v i e w e d B y For Construction Job #: 26.09 02 Co m m e n t R e s p o n s e s 06 . 1 6 . 2 0 2 6 JK E VJ T 03 Pe r m i t S e t 08 . 0 6 . 2 0 2 6 JK E VJ T 04 Co m m e n t R e s p o n s e s 09 . 2 5 . 2 0 2 6 JK E VJ T XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XOE XO E XO E XO E XO E XO E XO E XO E XO E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E X O E < <<< < <<< < < < < < < < < < < << WW W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W WWWWWWWWWWWWWWWWWWW W W W W W W W W W W W SS SS SS SS SS SS SS SS SS W W W W SS SSSSSS SSSSSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G UE G UE G U E G UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE G G G G G G G G G G G G G G G G G G G UE G UE G UE G E UE SS SS S S SSSS 20 00 2100 22 00 23 00 24 00 24 32 PC: 20+42.09 PC: 21+05.62 PC: 22+61.46 PT: 20+82.49 PT: 21+76.93 PT: 23+47.23 Start RV Loop Alignment STA:20+00.00 N:2712.79 E:1833.75 End RV Loop Alignment STA:24+32.26 N:2714.46 E:2051.03 88 3 0 88 2 9 88 2 8 88 2 7 88 2 6 88 2 5 88 2 4 88 2 3 88 2 2 88 2 1 88 2 0 88 1 9 88 1 8 88 1 8 88 1 7 88 1 6 88 1 5 88 1 4 88 1 3 88 1 1 88 1 0 88 0 9 88 0 8 88 0 7 88 0 5 88 0 4 88 0 3 88 0 2 882 7 88 2 6 88 2 2 88 2 1 88 2 0 88 1 9 88 1 8 88 1 7 88 1 6 88 1 5 88 1 4 88 1 3 88 1 2 88 1 1 88 1 0 88 0 9 88 0 8 88 0 7 8807 8808 8809 8810 8811 8812 881 3 881 4 88 1 5 88 1 6 88 1 7 88 1 8 88 1 9 88 2 0 88 2 1 88 2 2 88 2 3 8 8 2 4 8 8 2 4 8 8 2 5 8825 8823 88 2 8 8 8 2 8 8 8 2 7 8 8 2 6 8 8 2 5 8 8 2 4 8 8 2 2 8 8 2 3 8 8 2 1 8 8 2 0 8 8 1 9 8 8 1 7 8 8 1 4 8829 88 0 5 8 8 0 0 8 7 9 5 88 0 0 88 0 5 88 1 0 881 5 8 8 1 5 88 2 0 8 8 2 5 8 8 2 0 882 5 88 2 7 8828 8828 882 5 881 0 Existing Access Road Widen And Improve For Vehicular Use Proposed Parking Lot Utility Easement (Typ) (4) Proposed RV Sites Existing Access Road Widen And Improve For Vehicular Use Existing Access Road (4) Proposed RV Sites Widen Existing Access L7 L8 L9 L1 0 C6 C7 C 8 Sta:21+49.25 Off:59.09'L Elev:8826.83 Sta:21+68.00 Off:35.82'L Elev:8823.71 Sta:22+04.24 Off:30.63'L Elev:8820.65 Sta:22+45.83 Off:31.27'L Elev:8817.23 Sta:22+76.66 Off:40.46'L Elev:8814.39 Sta:20+58.69 Off:44.02'R Elev:8820.29 Sta:20+66.76 Off:79.68'R Elev:8818.13 Sta:24+09.75 Off:69.53'R Elev:8816.14 Sta:24+03.38 Off:34.64'R Elev:8813.29 Sta:24+31.80 Off:28.62'R Elev:8809.19 Sta:24+02.70 Off:6.00'R Elev:8807.27 Sta:23+99.73 Off:6.00'L Elev:8807.19 Sta:24+19.54 Off:28.72'L Elev:8802.78 Sta:20+38.51 Off:6.00'R Elev:8823.09 Sta:20+30.30 Off:21.70'R Elev:8821.22 Sta:20+10.05 Off:6.00'L Elev:8822.71 Flow Line Sta:21+37.12 Off:8.00'L Elev:8825.20 Flow Line Sta:22+35.00 Off:8.00'R Elev:8817.69 Inv. In Sta:24+10.22 Off:9.03'R Elev:8806.01 Inv. Out Sta:24+07.52 Off:22.52'L Elev:8804.95 Rip Rap Sta:23+96.63 Off:47.23'L Elev:8802.00 Rip Rap Sta:24+07.90 Off:45.47'L Elev:8802.00 Inv. In Sta:20+11.60 Off:8.30'L Elev:8822.00 Inv. Out Sta:20+30.22 Off:17.56'R Elev:8822.10 12.0 0 8X10' Water Treatment Shed 500 Gallon Concrete Residual Waste Evaporation Tank 1060 Gallon Poly Brine Waste Storage Tank 8'x20' ADA Parking Space With 5' Wide Walkway Maintain Max 2% Slopes Through Entire Surface Sta:21+49.24 Off:27.54'L Elev:8825.17 Sta:21+54.21 Off:24.96'L Elev:8825.01 (1) Proposed ADA RV Site With ADA Ramp Sta:21+11.16 Off:6.00'R Elev:8824.80 Sta:21+02.49 Off:14.00'R Elev:8824.43 Sta:20+75.07 Off:6.00'R Elev:8823.95 Sta:20+82.49 Off:14.00'R Elev:8823.96 8'x20' RV Access Parking Space RV Loop Alignment Profile Horizontal Scale: 1"=20' Vertical Scale: 1"=20' 8805 8810 8820 8830 8805 8810 8820 8830 20+20 EG 8 8 2 3 . 3 F G 8 8 2 2 . 7 7 20+40 EG 8 8 2 3 . 3 F G 8 8 2 3 . 2 4 20+60 EG 8 8 2 3 . 6 F G 8 8 2 3 . 7 1 20+80 EG 8 8 2 4 . 3 F G 8 8 2 4 . 1 8 21+00 EG 8 8 2 4 . 9 F G 8 8 2 4 . 6 5 21+20 EG 8 8 2 5 . 2 F G 8 8 2 5 . 1 2 21+40 EG 8 8 2 5 . 0 F G 8 8 2 5 . 0 2 21+60 EG 8 8 2 3 . 7 F G 8 8 2 3 . 7 5 21+80 EG 8 8 2 2 . 1 F G 8 8 2 2 . 3 0 22+00 EG 8 8 2 0 . 5 F G 8 8 2 0 . 8 5 22+20 EG 8 8 1 9 . 2 F G 8 8 1 9 . 4 0 22+40 EG 8 8 1 7 . 9 F G 8 8 1 7 . 9 5 22+60 EG 8 8 1 6 . 6 F G 8 8 1 6 . 5 0 22+80 EG 8 8 1 5 . 2 F G 8 8 1 5 . 0 5 23+00 EG 8 8 1 3 . 5 F G 8 8 1 3 . 6 0 23+20 EG 8 8 1 1 . 9 F G 8 8 1 2 . 1 5 23+40 EG 8 8 1 0 . 9 F G 8 8 1 0 . 7 1 23+60 EG 8 8 1 0 . 1 F G 8 8 0 9 . 5 0 23+80 EG 8 8 0 9 . 5 F G 8 8 0 8 . 4 0 24+00 EG 8 8 0 8 . 5 F G 8 8 0 7 . 3 0 24+20 EG 8 8 0 7 . 0 F G 8 8 0 6 . 2 0 2.35% -7.25% -5.50% Start RV Loop STA = 20+11.64 ELEV = 8822.578 End RV Loop STA = 24+24.89 ELEV = 8805.931 PVI STA: 23+45.91 PVI ELEV: 8810.27 K: 10.00 LVC: 17.52 BV C S : 2 3 + 3 7 . 1 5 BV C E : 8 8 1 0 . 9 1 EV C S : 2 3 + 5 4 . 6 7 EV C E : 8 8 0 9 . 7 9 HIGH PT STA: 21+28.56 HIGH PT ELEV: 8825.24 PVI STA:21+35.91 PVI ELEV:8825.50 K:3.00 LVC:28.80 BV C S : 2 1 + 2 1 . 5 1 BV C E : 8 8 2 5 . 1 6 EV C S : 2 1 + 5 0 . 3 1 EV C E : 8 8 2 4 . 4 5 Line Table Line L7 L8 L9 L10 Bearing N37°00'00"E N6°08'25"E N87°51'15"E S6°08'25"W Length 42.09' 23.14' 84.53' 85.02' Start Point (N,E) 2712.79,1833.75 2783.52,1873.76 2851.14,1924.07 2798.99,2060.13 End Point (N,E) 2746.41,1859.09 2806.53,1876.23 2854.31,2008.54 2714.46,2051.03 Curve Table Curve C6 C7 C8 Radius 75.00' 50.00' 50.00' Length 40.40' 71.31' 85.77' Tangent 20.70' 43.25' 57.81' Chord 39.91' 65.42' 75.63' Bearing N21°34'13"E N46°59'50"E S43°00'10"E Delta 30° 51' 35" 81° 42' 50" 98° 17' 10" Drawing Scale Units (Feet) 1" = 20' 0 20 40 N S W E C.08 RV Loop Plan And Profile Of 10 Pages 01 La n d U s e A p p l i c a t i o n 03 . 0 2 . 2 0 2 6 JK E # De s c r i p t i o n Da t e Dr a w n B y 7W R a n c h 34 1 2 C o u n t y R o a d 1 5 1 Gy p s u m , C o l o r a d o 8 1 6 3 7 1101 Village Road, Unit UL-3C Carbondale, CO 81623 (970) 510 - 5312 VJ T Re v i e w e d B y For Construction Job #: 26.09 02 Co m m e n t R e s p o n s e s 06 . 1 6 . 2 0 2 6 JK E VJ T 03 Pe r m i t S e t 08 . 0 6 . 2 0 2 6 JK E VJ T 04 Co m m e n t R e s p o n s e s 09 . 2 5 . 2 0 2 6 JK E VJ T 43 ' 22' Typical Dimensions Of RV Site Water and Storm Sewer Trenching Detail 24" Wide Trench 6" Depth Bedding Material Below Utility Line 12" Depth Bedding Material Above Utility Line Service Line Sizing and Material As Per Plan Shown on Utility Sheet Wrap Bedding Material Within Geotextile Fabric Bedding Material 3 4" Screened Rock, Class 6 ABC, Or As Specified By Utility Provider Hardscape Softscape Class 6 ABC or Approved Alternate as per Geotech Native Material as Approved per Geotech Compact to 95% ASTM Standard Proctor Layback as Necessary to meet OSHA Requirements For Specific Soil Type Hardscaping With Sub Base Material See Detail Minimum 6" of Top Soil Revegetate Bury Depth Water: Minimum 7' Storm Sewer: As Per Plan Not to Scale Note: Water and Sanitary Sewer Service Lines Require a Minimum 10' of Separation Road Base Driveway Detail Not to Scale 8" Of Class 6 Aggregate Base Course Compact to 95% ASTM Standard Proctor Scarify and Recompact Bottom of Excavation to 95% ASTM Standard Proctor Minimum 6" of Top Soil Revegetate as Necessary DESIGN NOTES ·Design per performance test per ASTM C1227 ·Top surface area 56.25 ft² ·f'c @ 28 days; concrete = 6,000 PSI Min. Installation: ·Tank to be set on 5" min. sand bed or pea gravel ·Tank to be backfilled uniformly on all sides in lifts less than 24" and mechanically compacted ·Excavated material may be used for backfill, provided large stones are removed ·Excavation should be dewatered and tank filled with water prior to being put in service for installation with water table less than 2' below grade ·Meets C1644-06 for resilient connectors ·Inlet and Outlet identified above pipe ·Delivered complete with internal piping ·4' Maximum bury depth Top View Section View 4.83' 4.83' 20" Clear Access Tank ID 24" Min. Riser Height 5" Conc. Risers To Grade Flexible Boot 3" Conc. Butyl Rubber Sealant 5.67' 4.67' 4.33' 4.50' 1.58' Residual Pit Tank 500 Gallon, 1-Compartment Concrete Tank Not to Scale Grated Manhole Lid For Evaporation Brine Tank 500 Gallon, 1-Compartment Tank Not to Scale 24" Wide Trench 6" Depth Bedding Material Below Utility Line 12" Depth Bedding Material Above Utility Line Residential Service Line Gas: Size and Material to be Provided by Black Hills Energy Communications: 2" PVC Conduit Electric: 4" PVC Conduit Verify Size and Material with Utility Provider Prior to Installation. Install Tracer Wire Above Conduit. Bedding Material 3 4" Screened Rock, Class 6 ABC, Or As Specified By Utility Provider Hardscape Softscape Class 6 ABC or Approved Alternate as per Geotech Native Material as Approved per Geotech Compact to 95% ASTM Standard Proctor Layback as Necessary to meet OSHA Requirements For Specific Soil Type Hardscaping With Sub Base Material See Detail Minimum 6" of Top Soil Revegetate 30" Minimum 72" Maximum Bury Depth Residential Service Gas, Communications, and Secondary Electric Trenching Detail Not to Scale Note: Gas and Secondary Electric Service Lines Require a Minimum 3' of Separation. Communications and Secondary Electric Require a Minimum 2' of Separation. Wrap Bedding Material With Geotextile Fabric If Screened Rock Or Gravel Is Used C.08 Construction Details Of 10 Pages 01 La n d U s e A p p l i c a t i o n 03 . 0 2 . 2 0 2 6 JK E # De s c r i p t i o n Da t e Dr a w n B y 7W R a n c h 34 1 2 C o u n t y R o a d 1 5 1 Gy p s u m , C o l o r a d o 8 1 6 3 7 1101 Village Road, Unit UL-3C Carbondale, CO 81623 (970) 510 - 5312 VJ T Re v i e w e d B y For Construction Job #: 26.09 02 Co m m e n t R e s p o n s e s 06 . 1 6 . 2 0 2 6 JK E VJ T 03 Pe r m i t S e t 08 . 0 6 . 2 0 2 6 JK E VJ T 04 Co m m e n t R e s p o n s e s 09 . 2 5 . 2 0 2 6 JK E VJ T Sanitary Sewer Trenching Detail 24" Wide Trench 6" Depth Bedding Material Below Utility Line 12" Depth Bedding Material Above Utility Line Residential Sanitary Sewer Line Wrap Bedding Material Within Geotextile Fabric Bedding Material 3 4" Screened Rock, Class 6 ABC, Or As Specified By Utility Provider Hardscape Softscape Class 6 ABC or Approved Alternate as per Geotech Native Material as Approved per Geotech Compact to 95% ASTM Standard Proctor Layback as Necessary to meet OSHA Requirements For Specific Soil Type Hardscaping With Sub Base Material See Detail Minimum 6" of Top Soil Revegetate Bury Depth Sanitary Sewer: Minimum 4.5' Not to Scale Note: Water and Sanitary Sewer Service Lines Require a Minimum 10' of Separation 2.33' 1.25'1.17' 2.33' 2.08' 0.58'0.42' 1.25' 1.00' 1.17' 2.33' 1.25' Top View Section View Top View Lid View Knock Down Baffle 2" Conc. 1.5" Conc. Side View End View 1.00' 2.33'1.25' 1.00' 1.00' Riser Section Access To Grade Required DESIGN NOTES ·6000 PSI Concrete ·7 Outlet Equal Flow ·Slide-In Baffle ·4" Pipe Penetration Ports ·Connectors Cast Into The Box ·12" Riser Available ·Roto-Flow 4" Or Ploylock Equalizer "V-Notch" Weir Required For Connection Weight: D-Box With Baffle - 200 lbs D-Box Lid - 75 lbs D-Box Riser - 140 lbs Concrete Distribution Box Detail Not to Scale Inspection Port Detail Not to Scale Slip On PVC Cap. Do Not Use Glue. Finish. Grade 4" Sch-40 PVC Inspection Pipe 1/4" Drilled Hole For Ventilation, Located Below Slip On Cap Quick 4 Standard Chamber, See Typical Section Detail 2" Leveling Sand Uncompacted Native Soil Irrigation Valve Box Cover Flush With Finished Grade 6" Topsoil Layer Minimum 6" of Top Soil Revegetate Typical Bed Detail Not to Scale 2" Leveling Sand Meeting Secondary Sand Requirements Of OWTS Regulations Undisturbed, Native Soil Quick 4 Standard Chamber (Typ.) Distribution Piping Releases Effluent Into Ends Of Infiltrators Native, Uncompacted Backfill 12.00' Maximum Width Per Bed Min. 1' Cover Over Bed 34" 2" 8" 12" Maintain Existing G r a d e S l o p e OWTS Installation Notes 1.The Contractor/Installer Shall Conform To Garfield County Public Health And Environment On-Site Wastewater Treatment System (OWTS) Regulations. 2.The OWTS Shall Be Installed As Per CRC Approved Plans And Manufacturer Recommendations. Substations Or Field Changes Shall Not Be Completed Without Approval From CRC. Shop Drawings Shall Be Provided For Approval By CRC Prior To Construction. 3.The Septic Field Shall Be Kept Protected By Fencing Or Other Measures To Ensure No Equipment, Staging, Storage, Or Any Other Materials That Will Compact The Septic Field Soils. Any Soils Compacted Shall Be Replaced With Garfield County OWTS Regulation Approved Sand. 4.Piping Shall Be Solvent Welded. All Piping Shall Be Bed As Per The Sanitary Sewer Pipe Bedding Detail Provided. 5.Re-Seeding And Revegetation Of All OWTS Components Is The Responsibility Of The Owner. Re-Seeding Shall Be Completed As Soon As Feasibly Possible. 6.Septic Tank And Other OWTS Components Shall Be Installed With Water Tight Assemblies To Prevent Additional Water Entering The OWTS. Overloading The OWTS With Groundwater Or Other Constant Flows Will Compromise The System. 7.Anti-Floatation Measures Must Be Taken For All OWTS Components, Especially Concrete Tanks, If Groundwater Is Present. Soil Treatment Area Notes 1.Soil Treatment Area Shall Be Constructed With Quick 4 Standard Chambers, As Described In The Drawings And Report. 2.Chambers Shall Be Installed As Level As Possible Within The Bed. A Total Of 700 Quick 4 Standard Chambers Shall be Installed In A 7-Bed Configuration. Each of the Seven Beds are 12' Wide x 100' Long. 3.Chambers Shall Have At Least 1' Of Cover Minimum And 4' Of Cover Maximum. 4.All Effluent Lines From The Tank To The Distribution Box Shall Be 4" Sch-40 PVC. All Effluent Lines From The Distribution Box To The Manifold Shall be 4" Sch-40 PVC. Use Adequate Pipe Bends And Fittings To Follow Natural Grade And To Meet Minimum Slope And Cover Requirements. All Manifold Lines Shall Be 4" Sch-40 PVC and Be Installed Level. A Quick 4 Splash Plate Shall Be Installed At Distribution Pipe End At The Quick 4 Infiltrator End Cap. 5.4" Inspection Ports Shall Be Installed At Each Corner Of Each Bed Of The Soil Treatment Area. Max. 4' Cover Over Bed Sanitary Sewer Sleeving Detail Not to Scale Schedule 40 PVC Encasement Pipe. Pipe Size To Be Large Enough To Sufficiently Slide Over Sanitary Sewer Pipe. Schedule 40 PVC Rigid End Section At The Start And End Of Encasement Pipe, Glued In A Water Tight Fashion. Sanitary Sewer Service Line. Size And Material Called Out On OWTS Layout Plans. Drill Hole In Rigid End Section Large Enough For Sanitary Sewer Pipe To Slide Through At The Lowest Point In The Encasement. A PVC, Water-Tight, Underground, Sealant Shall Be Used At Drill Hole Once Encasement Is Set. Sanitary Sewer Pipe Shall Rest On Bottom Of Encasement. Maintain Specified Slope. OWTS Tank 1,500 Gallon, 1-Compartment Tank Not to Scale C.10 OWTS Details Of 10 Pages 01 La n d U s e A p p l i c a t i o n 03 . 0 2 . 2 0 2 6 JK E # De s c r i p t i o n Da t e Dr a w n B y 7W R a n c h 34 1 2 C o u n t y R o a d 1 5 1 Gy p s u m , C o l o r a d o 8 1 6 3 7 1101 Village Road, Unit UL-3C Carbondale, CO 81623 (970) 510 - 5312 VJ T Re v i e w e d B y For Construction Job #: 26.09 02 Co m m e n t R e s p o n s e s 06 . 1 6 . 2 0 2 6 JK E VJ T 03 Pe r m i t S e t 08 . 0 6 . 2 0 2 6 JK E VJ T 04 Co m m e n t R e s p o n s e s 09 . 2 5 . 2 0 2 6 JK E VJ T