Loading...
HomeMy WebLinkAboutBlower Door TestINSULATION Residential Air Infiltration Test Report Test date: Project name: Address: Code: Conditioned volume: Attic: Crawlspace: Garage: Measured airflow: Temperature; Inside: Temperature; Outside: Elevation: Corrected airflow: 2018 IECC maximum allowed leakage rate: Tested air leakage rate: Test code compliance: Test notes: 8/12/2026 Powers Work Shop New Heated Storage Garfield 2018 IECC 10,658 non -vented NA excluded 485 75 79 6,514 508 3.0 2.9 PASS Cubic Feet CFM50 Cubic Feet per Minute at 50 Pascal CFM50* Cubic Feet per Minute at 50 Pascal ACH50 Air Changes Per Hour at 50 Pascal ACH50 Air Changes Per Hour at 50 Pascal Final blower door test. Passes the 2018 IECC infiltration requirments. * Test results have been corrected for elevation and air density temperature differential. INSULATION Residential Air Infiltration Test Report Test date: 8/12/2026 Project name: Powers Work Shop Address: New & Existing Heated Storage Garfield Code: 2018 IECC Conditioned volume: Attic: Crawlspace: Garage: Measured airflow: Temperature; Inside: Temperature; Outside: Elevation: Corrected airflow: 2018 IECC maximum allowed leakage rate: Tested air leakage rate: Test code compliance: Test notes: 17,983 Cubic Feet New non -vented, Existing vented NA Existing 2,701 CFM50 75 79 6,514 2,831 CFM50* 3.0 ACH50 9.4 ACH50 FAIL Cubic Feet per Minute at 50 Pascal Cubic Feet per Minute at 50 Pascal Air Changes Per Hour at 50 Pascal Air Changes Per Hour at 50 Pascal Final blower door test with the existing garage space included. Existing space garage door and vented attic space are the sources for the higher infiltration rate. * Test results have been corrected for elevation and air density temperature differential.