Loading...
HomeMy WebLinkAboutManual S Report 02.03.26Manual S Compliance Report Job: AR3276.4A(Co27) wrightsoW p p Date: Feb 03, 2026 Entire House By. FH Clayton Homes Plan: AR3276-4A(CO27) 5000 Clayton Road, Maryville, TN 37804 Phone: 865-380-3000 '. .. ... R ' L For: AR-3276-4A(CO27), CMH WEST AUG 102026 GARFIELD COUNTY COMMUNITY DEVELOPMENT Design Conditions Outdoor design DB: 92.8°F Sensible gain: 19606 Btuh Entering coil DB: 77.8°F Outdoor design WB: 62.4°F Latent gain: 0 Btuh Entering coil WB: 61.9°F Indoor design DB: 75.0°F Total gain: 19606 Btuh Indoor RH: 50% Estimated airflow: 780 cfm Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SpIitASHP Manufacturer: Smart Comfort Model: R4H5S24*K*AAA*+FEVA0024**+NAVA43601 CK Actual airflow: 780 cfm Sensible capacity: 20898 Btuh 107% of load Latent capacity: 1023 Btuh 0% of load Total capacity: 21920 Btuh 112% of load SHR: 95% Heiting Equipment Design Conditions Outdoor design DB: 3°F Heat loss: 34985 Btuh Entering coil DB: 59.1°F Indoor design DB: 70. °F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Smart Comfort Model: R4H5S24*K*AAA*+FEVA0024**+NAVA43601CK Actual airflow: 780 cfm Output capacity: 22800 Btuh 65% of load Capacity balance: 27 °F Supplemental heat required: 12185 Btuh Economic balance: -99 °F Backup equipment type: Elec furnace Manufacturer: Model Actual airflow: 780 cfm Output capacity: 34985 Btuh 100% of load Temp. rise: 50 °F Meets all requirements ofACCA Manual S. W r lg htSOtt* 2026-Feb-16 10:33:24 a ,.­..,.­, ­ RigFt-SuteSUriversal202424.0.02 RSU55722 Page 1 C'�..tsoft\BaseMod els\20251ARS\AR-3276-4A(CO27).rup Calc=MJ8 FrontDoorfaces E -- wrightsofto Building Analysis Entire House Clayton Homes 5000 Clayton Road, Maryville. TN 37804 Phone: 865-380-3000 For: AR-3276-4A(CO27), CMH WEST Job: AR-3276-4A(Co27) Date: Feb 03, 2026 By. FH Plan: AR3276-A(CO27) Location: Indoor: Heating Cooling CO 27 Indoor temperature (`F) 70 75 Elevation: 4697 ft Design TD (°F) 70 18 Latitude.- 40 °N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (grAb) 59.9 -25.3 Dry bulb (" F) 0 93 Infiltration: Daily range (°F) - 32 I H i Method Simplified Wet bulb (°F) - 62 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Component Btuh/ft2 Btuh % of load Walls 3.9 5951 17.0 Glazing 24.4 4995 14.3 Doors 22.3 937 2.7 Ceilings 2.0 4366 12.5 Floors 2.2 4834 13.8 Infiltration 3.5 6159 17.6 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 7742 22.1 Adjustments 0 Total 34985 100.0 Cooling Component Btuh/ft2 Btuh % of load Walls 1.0 1571 8.0 Glazing 38.0 7790 39.7 Doors 7.5 314 1.6 Ceilings 1.3 2938 15.0 Floors 0.2 479 2.4 Infiltration 0.4 786 4.0 Ducts 0 0 Ventilation 1977 10.1 Internal gains 3750 19.1 Blower 0 0 Adjustments 0 Total 19606 100.0 Latent Cooling Load = 0 Btuh Overall U-value = 0.048 BtuhV-°F, Window / FloorArea = 9.2 % Data entries checked. Glaz-ng_ Doors C1 Floors ation Inhltrahon WallsVentilation .Internal Gains Glazing-1 �.: Infiltration Floors Other Ceilings w righ tsoft" 2026-Feb-16 10:3324 •..... •••.. Right-SUIegUriversal202424.002RSU55722 Page '' tsoftOaseModels12025WRSWR-3276-4A(CO27).rup Calc=MJ8 Front Door faces: E Component Constructions om wrightsoft' p Job: AR-3276�A(CO27) Date: Feb 03, 2026 Entire douse By: FH Plan: AR3276-4A(CO27) Clayton Homes 5000 Clayton Road, Maryville, TN 37804 Phone: 865-380-3000 ih For. AR-3276-4A(CO27); CMH WEST Location: Indoor: Heating Cooling CO 27 Indoor temperature (°F) 70 75 Elevation: 4697 ft Design TD (°F) 70 18 Latitude: 40°N Relative humidity (%} 50 50 Outdoor: Heating Cooling Moisture difference (grAb) 59.9 -25.3 Dry bulb (°F) 0 93 Infiltration: Daily range (°F) - 32 ( H ) Method Simplified Wet bulb (°F) - 62 Construction quality Average Wind speed (mph) 150 7.5 Fireplaces 0 Construction descriptions Or Area U-Value Insul R Htg HTM Loss Clg HTM Gain ft' Btuh'ft'--T ft=`F'Btuh Btuh'ft' Stuh Btuhtft' Btuh Walls THP-560 n 240 0.056 21.0 3.90 937 1.03 247 ne 37 0.056 21.0 3.90 144 1.03 38 e 542 0.056 21.0 3.90 2116 1.03 558 s 215 0.056 21.0 3.90 840 1.03 222 sw 43 0.056 21.0 3.90 166 1.03 44 w 448 0.056 21.0 3.90 1750 1.03 462 all 1525 0.056 21.0 3.90 5951 1.03 1571 Partitions (none) Windows Clayton - Thermopane Lovd-E: Clayton - Thennopane Low-E; 6.67 ft head a 66 0.350 0 24.4 1610 32.6 2153 ht w 139 0,350 0 24.4 3385 32.6 4526 all 205 0.350 0 24.4 4995 32.6 6679 Doors CMH - Standard Door: CMH - Standard Door- Solid no storm s 21 0.320 0 22.3 468 7.49 157 w 21 0.320 0 22.3 468 7.49 157 all 42 0.320 0 22.3 937 7.49 314 Ceilings THP-1024: Flat ceiling, tar and gravel roof mat, mtl deck 2237 0.028 38.0 1.95 4366 1.31 2938 Floors THP-3047 2237 0.031 22.0 2.16 4834 0.21 479 *wrightsoftn 2026-Feb-1610:33:24 .M,:--.... .,.,..- -11 Riglg-Stite0OUnversal202424.0.02RSU55722 Page �`�...tsofteaseModels\2025LARS\AR-3276-4A(CO27).rt{r Calc=MJ8 FrontDoortaces: E ill ensrights®St£ Project Summary Entire House Clayton Homes 5000 Clayton Road, Maryville, TN 37804 Phone: 865-380-3000 Job: AR3276-0A(CO27) Date: Feb 03, 2026 By. FH Plan: AR3276-4A(CO27) For: AR-3276-4A(CO27), CM WEST Notes: Duct Cooling Capacity = 51,100 BTU/HR Weather: CO 27 Winter Design Conditions Summer Design Conditions Outside db 0 'F Outside db 93 'F Inside db 70 °F Inside db 75 °F Design TD 70 °F Design TD 18 °F Daily range H Relative humidity 50 % Ventilation Method MJ8 Moisture difference -25 gdlb Heating Summary Structure 27243 Btuh Ducts 0 Btuh Central vent (120 cfm) 7742 Btuh Outside air Humidification 0 Btuh 0 Btuh Equipment load 34985 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 ng Area (fF) He 2237 Co 2237 Volume (fig) 17899 17899 Air changes/hour 0.32 0.16 Equiv.AVF (cfm) 95 48 Heating Equipment Summary Make Smart Comfort Trade 15 SEER2 R SERIES R410AHP Model R4H5S24*K"AAA'` AHRI ref 210537896 Efficiency 7.5 HSPF2 Heating input Heating output 22800 Btuh @ 47-F Temperature rise 32 °F Actual airflow 780 cfm Air flow factor 0.029 cfm/Btuh Static pressure 0.30 in H2O Space thermostat Capacity balance point = 27 'F Backup: Input =10 kW, Output = 34985 Btuh, 100 AFUE Sensible Cooling Equipment Load Sizing Structure 17629 Btuh Ducts 0 Btuh Central vent (120 cfm) 1977 Btuh Outside air Blower 0 Btuh Use manufacturer's data n Rate./sopna multiplier 0.98 Equipment sensible load 19175 Btuh Latent Cooling Equipment Load Sizing Structure 310 Btuh Ducts 0 Btuh Central vent (120 cfm) -1736 Btuh Outside air Equipment latent load 0 Btuh Equipment Total Load (Sen+Lat) 19175 Btuh Req. total capacity at 0.70 SHR 2.3 ton Cooling Equipment Summary Make Smart Comfort Trade 15 SEER2 R SERIES R410AHIP Cond R4H5S24*K*AAA* Coil FEVA0024**+NAVA43601 CK AHRI ref 210537896 Efficiency 12.0 EER2,15.2 SEER2 Sensible cooling 16380 Btuh Latent000ling 7020 Btuh Total cooling 23400 Btuh Actual airflow 780 cfm Airflowfactor 0.044 cfrnBtuh Static pressure 0.30 in H2O Load sensible heat ratio 1.00 Calculations approved byACCAto meet all requirements of Manual J 8th Ed _ wrigtltts10 - 2026-Feb-1610:33:24 •� -•�•-•������ Rigt*SutegUnversal202424.002RSU55722 Paget ...tsoftlBaseModels\2025kARSWR-3276-4A(CO27).np Calc=MJ8 FronlDoorfaces E Job #: AR-3276-4A(CO27) Performed by FH for: AR-327611A(CO27) Level 1 Clayton Homes 5000 Clayton Road Maryville, TN 37804 Phone: 865-380-3000 dm Scale: 1 :130 Page 1 RightSuiteO Universal 2024 24.0.02 RSU55722 2026-Feb-1610:34:08 ls\20251ARSWR 3276-4A(CO27).rup