HomeMy WebLinkAbout1325 I ,
.4,11 1325
Phone No. GARFIELD COUNTY Address
945 -8241 BUILDING DEPARTMENT 2014 Blake Ave
Job Address Green Subdivision - Grand ¥alley Type Oco CY
Nature of Work Building Permit
Use of Building Residence
Owner Robert J. & Mary J. Rowlands, Jr.
Contractor Owner
Amount of Permit $ 177.00 Date October 22. 1979
�� 4 Toni L r erwnnd
cl
k
fir Cot 40 /2 e RECEIVED OCT 1 2 1979
9; 1'
Building Permit Application
Ne 2127
Garfield County, Colo. , 1919
Owner: &E TsT w ,N14
Contractor or Builder: l�crJ Jy e / /
s Location: �2RJ/__
_e- eSek J _ 9JfjtJ [y n[c y / � vT/ - C3RAtecd ()4//e.�! d0
}' Purpose for which building is to_be used: -• . • ,/
r
Size of Lot: - lam // es F e.
Distance of building from property line at:
Front Rear 19,
Left side - .3 _ Right side /7
Distance from nearest building: 7o / Number of stories: _
Source of water supply: city Number of rooms: _ 7
Type of sewage disposal: s'ep72 C., Type of foundation: f'e w P.Re Tc f 6/o ek
Width of Building: __— '' 1r ' Material in outside walls: «) n/r d
Length of Building: .39 G / Exterior Finish: .4 nii rt.,
Height of walls: /0 / / Type of roof: .4 S A c f M4 /
/
Floor space in sq. ft.:--/A? S O C / r' /
W
Estimated Cost: $ cal 4000 '
Date construction win start: / - g • Date of completion: _
Permit Charge: $ 7 .� _ per 1st $1,000 Valuation.
Q ttit•- \StAiL.$_S "t.�____ per each additional $1,000 Valuation,
TOTAL $ _��� •
And 1 /We hereby agree to build strictly to the terms of the above description, and also to clear the
grounds adjacent street or streets of all rubbish and debris caused by the construction of said building.
i p. ♦ l/u/14-i e:
Respectfully, Ate4
Er
i
The County Commissioners hereby grant the above permit as per terms therein stated. This / CP
day of CO - - 1 ' _ , 19
rr
Building Inspector
Clerk
i GARF IELD COUNTY /)
STATE OF Colorado / /
s !l//
Office of Building Official
1 REQUEST FOR INSPECTION 3 0 S
• Date S -21 r Permit No.
I ime Gi : 3 v
. ecelved � - P.M. Dist� No 1
1 �to C1V .Qgi.3Q1 - .v. . —W DMA- Q,
Job Add M 1 Locality
Names t. Le A a.bin�I5 Contractor
Nsme
:UILDIN PLASTERING ELECTRICAL PLUMBING HEATING
Fou • - on Wire ❑ Rough Wiring .0 Rough... ........ .... ❑ Rough ❑
Chimney 0 Lath ❑ Finish Wiring..❑ Final ❑ Final ❑
' Framing ❑ Scratch ❑ Fixtures ❑ Sewers ❑❑ Water Heater.. ❑
Final ❑ Brown ❑ Motors. ❑ Gas
Finish ❑ Cesspool ❑
Wallboard ❑
READY Fee NSPECTION 00 • 4117. Mon. Tue . Wed. Thurs. Fri. ` �' '.' .
Inspector Inspection Made S7/ ? Y /Vd J� / /' d O
. . Up CALCULATION FOR ROOF /CEILING
,
LINE TABLE R -1 ROOF /CEILING AREAS SO, FT.
1. GROSS ROOF AREA / 3 VC
2. SKYLIGHT AREA
3. ROOF VFNT ARFA
4. OTHER (SPECIFY) ,
5. NET (OPAQUE) ROOF AREA , TABLE R -4 FRAMING AND CAVITY RATIO
/
LINE 1 - SUM 2 THRU 4 PO FRAME . FRAMING CAVITY
6. FRAMING AREA (Afr) ,SPACING RATIO RATI'0
IINF 5 X TABIF R -4 Y 3 1?" 0.13 0.87
7. CAVITY AREA (Ac) 16" 0,10 0.90
IINF 5Y TABJF R -4 ) 2 ? / ,24" 0.06 0.94 ,
TABLE R -2 OPAQUE ROOF /CFIIING CALCULATIONS
SOURCE OF ROOF /CEILING HEATING
THERMAL MATERIALS WINTFR R; VAI LIES
RESISTANCE FRAMING CAVITY
8. OUTSIDE AIR FILM .,/ 7 • /2
9. EXTERIOR FINISH , 3 3 , 3.3
10. OUTSIDE SHEATHING • (pa
,..,a1,,,,_
12 CA3JJY I►_.. i 00
�
13, CAVITY AIR SPACE
15. )NSIDE AIR FILM • hl ,1,/
16. OTHER (SPECIFY)
17. OTHERJSPECIFY
18. TOTAL RESISTANCE (Rt) -r . /7 99 �
SUM OF LINES 8 THRU 17
19. Ufr (FRAMING) 076
1 /Rt (FRAMING fSJ IJMN)
20. Up (CAVITY) O
1 • , I Y 1_ w a..
_Mill R -3 SUMMATION OF TRANSIMJSSION VAIIIES OR ROOF!"FJI ING
_ 1 ' - A -- flu ■ 1 t ± flu L . .
FRAMINL,_ .n7F, LINE 19. 73 IINF fi. x .30
CAVITY ,ou(f LINE 20. /A97 LINE 7. 52-
SKYLIGHT _ 1/R LINE 2.
ROOF VENT 1/R i LINE 3.
1 1 R t LINE 4.
W OTHER 1 R I LINE 5.
1 ' `, -�e.." An = ( ,3 Po SUM U X A = G 3.36
Up ROOF /CEILING = SUM OF (U- VALUES X CORRESPONDING AREAS) _ .0
,, GROSS ROOF /CEILING AREA (An)
(.
- 21.
Y.
1.
• Uo CALCOLAT10td FOR ALL
•
LINE TLa.0 E W -1 WALL AREAS SQ. FT.
1. GROSS WALL AREA (AQ) / 3 7 7
2. WINDOW AREA A) 2 y
4. OTHER (SPECIFY) TABLE W -4
5. OTHER (SPECIFY)_____ ____ FRAMING AND CAVITY RAT19
6. OPAQUE WALL AREA (Aop)
LINE 1.- SUM 2 THRU 5 /0 9.5- STUD FRAMING CAVITY
7. FRAMING AREA (Af SPACING RATIO RATIO
I INE__LL ABIF W -4 I 17" ,17 .83
8. CAVITY AREA (Ac) 16" .15 .85
LINE 6 X TABLE W -4 73( 24" .10 .90
TABLE W -2 OPAQUE WALL CALCULATIONS (FRAMING AND CAVITY)
SOURCE OF WALL HEATING
THERMAL MATERIALS WINTER R- VALUES
RESISTANCE FRAMING CAVITY ,
9, QjIISjQ_LAIR FILM ./ 4/7
__.1.I._. JLRW&JINI . •G/
11. QU1LID/ SH,ATF INC t - 3 • 93
12. FRAMING 4 Y 7 �
13. CAVITY I�JSULATION �.-- "� -..•-., /9.
14. CAVITY AIR SPACE
15. INTERIOR FINISH • YS ,`/‘
)6, . USIDE AIR FILM ,Ing , /og
17. OTHER (SPECIFY)
18,_ 02ER (SPECIFY) .
19. TOTAL RESISTANCE (Rt • 7. zl *Cy
.___...- i1U- F.IJJIFS -9 T11RU 19a . a. ...Mr 20. Ufr (FRAMING)
1 /Rf (FRAMING COLUPN Q/a
21. 1/ (CAVITY) �� o Y
1 / R t _(� ZIY_S.Q111�1�
TABLE W -3 SUMMATION OF TRANSMISSION VALUES FOR WALL
SOURCE U -VALUE FROM LINE AREA FROM LINE U -VALUE X A
FRAMING , o/ LINE 20. I . • V
CAVITY •O c/ LINE 21. _ 93/ LINE 8. 87•2c ,
_WINDOWS 1 R . '/9 IINF 7. // 7•//
_ _ MORS_ C _ 1/R 1 .2.7 LINE 3. /y 37 ,
__ OTHER _woof 1/R LINE 4.
OTHER 1JR LINE 5.
_IOTAL g An SUM U X A 1 7cL'3/
Uo WALL = SUM OF U- VALUES X CORRESPONDING AREAS ._ , /2_ z_
RI WALL ARE' Ao
_ 20.
•
up CALCULATION FOR FLOOR
LINE TABLE F -1 FLOOR AREAS SQ. FT.
1. GROSS FLOOR AREA id PO _ TABLE F -4 1
2. FRAMING AREA (Af - FRAMING AND CAVITY RATIO
LINE 1 X TABLE F -4 _ /3 er JOIST FRAMING CAVITY
3. CAVITY AREA /2—Y2- SPACING RATIO RATIO
LINE 1 X TABLE F -4 12" 0.13 0.87
4. OTHER (SPECIFY) 16" 0.10 0.90
5. OTHER (SPECIFY) 24" 0.06 0.94
,
TABLE F -2 FLOOR CALCULATIONS
SOURCE OF FLOOR HEATING
THERMAL MATERIALS WINTER R- VALUES
RESISTANCE FRAMING ' CAVITY
6. OUTSIDE AIR FILM ./ 7 .17
7. EXTERIOR FINISH
8. FRAMING • it/
9, CAVITY INSU1ATION zZ_ 7/ 00
10. CAVITY AIR SPACE
11. DECKING• . 93 e 9,!;
12. FLOOR FINISH _(,S! ,(.f,
13. INSIDE AIR FILM ,f/2 .92-
14. OTHER (SPECIFY'
15. OTHER (SPECIFY
16. TOTAL RESISTANCE (Rr
SJJJL4I .L . H' /7 ( H. 70
17. Ufr (FRAMING) co
- `�
18. U CAVITY) o
1 /Rt (CAVITY COLUMN) ,
TABLE F -3 SUMMATION OF TRANSMISSION VALUES FOR FLOOR
SOURCE U -VALUE FROM LINE AREA FROM LINE U -VALUE X A
FFB liULQ . 0 6 LINE 17 / 3
U S fA V1TV LINE 18 / 2-' Z- �j
MIL 1 /R I INF 4
OTHER 1/R LINE 5
TOTAL , Ao = /3• 8'D SUM U X A = 19.7 b
SUM OF (U- VALUES X CORRESPONDING AREAS) _
Up FLOOR = .-- Ao , 64
C
22.