nE (01I
OWING ,I OI:ING ITEMS HAVE EITHER BEEN OMITTED FR0,4 YOUR PLANS OR DID NOT r THE
c - ;OVISIONS OF THE UNIFORM BUILDING CODES. PLEASE CHECK ALL x ed ITEMS BEFORE BEGINNING
C.O NS1 RUCT I ON. All references are 1982 UBC unless otherwise noted.
1. Structural concrete for footing and foundations and load bearing slabs on grade is
is required to be 3000 PSI within 30 days. 2604(c)E and Standard 26 -1
"2. Reinforcement "steel for footings: 2"4 rebars continuous -
for foundations: 2r4 Rebard at top & bottom of wall
3, Frost protection for footings: 30" minimum to the TOP of the footing. 2907(a)
1 Foundations shall extend at least 6 inches above grade. 2907(a) ) . Provide for the drainage of surface /runoff water away from the building. 2905(f)
P
6.
Foundation plates on mud sills shall be redwood or pressure treated wood. 2516(C)3
---- Foundation plates shall be bolted to the foundation with anchor bolts
f 1/2" x 7" - 6 feet on center; 1/2" x 15" in unreirifo iced grouted masonry. 2907(e)
8. Solid blocking is required betweenmjoists w aall b a
g p t s
oin.is2518(d)3Table 25 -R -1
g , b; i th joists @ 24" on center: P Y td ar _0 C _ Table 25 -U --J -1
- 10. Joists are insufficient for the spans: Minimum X
- 11. Exam insufficient for loads /spans _ X M1NIM ize allowed. Tabl 25d
12. A glu-lam or a steel beam is require d at .minimum Tables
of .5 x d's or 2 x 6
- 13. All walls bearing two (2) floor loads are req red to e a
studs with a maximum spacing of 16" on center. 2518(g) 1,3
5
_ ' 14. Shear bracing required: both sides of each cor1er a n d cever y 2 5 c linea l fe Standard ) 51
15. Brick ties; 1" x 22 gauge, spaced a minimum of
�16. Ceiling /floor11headroom is required to be a minimum of 7'6" in all rooms except kitchen
halls, bathrooms and storage areas which may be a minimum of 7'0 ". 1207(a)
17. Minimum stairwell headroom measured from the nosing Oof UM 6'6". - 3305 withi
- 18. ALL STAIRS: MAXIMUM rise - 7 1/2"; MINIMUM run a flight of stairs is 3/8 ". 3305(c) RESIDENTIAL EXCEPTION - 8" Rise & 9" Tread).
lq. Minimum width of stairways in a single- family dwelling is 30".
33 shall be not
20. Handrails: minimum height - 30 "; maximum height - 34", han
less than 1 1/4" or more than 2 inches in 4f
Open area. 3305(j)
21. Residential guardrails: minimum height 3o 47
Open guardrails and stair railings shall have a pattern such that a sphere 6" in
diameter cannot pass through. 1711 (EXCEPTION - ISOLATED COMMERCIAL MAY BE 12 ")
22. Underfloor /crawl space ventilation is required. 2517(c)6
2
23. Access to underfloor areas shall bea minimum
h f of 1 8 " x 24". 2516ht 44" or area
24. Windows in unfinished basements: 4 ' x
used for storage only and plans marked "STORAGE AREA ONLY ". 1204 ( 26, below)
)(25. Windows located within 18" of the floor and 18" or wider-are required to be tempered
or protected. 5406(d)6 & 7
)(26. EVERY bedroom below the fourth (4th) floor without a door opening to the outside shall
have a least one window that meets the following requirements:
MAXIMUM sill height: 44 inches
x MINIMUM net clear opening width: 20 inches
yC - MINIMUM net clear opening height: 24 inches
MINIMUM net clear opening: 5.7 square feet 1204
27. Provide combustion air for furnace /water heater. UMC 607
- 28. Provide floor drain for water heater or pipe P & T relief valve to the outside of the
building. UPC 1007
29. Furnace and water heater must each be removable without moving the other. UMC 703
- 30. Each water closet shall have minimum clearances of 24" in front and 30" width (15' cen
line to nearest sidewall). Sec 511
_ 31. Bathrooms without windows shall be equipped With a fan vented to outside air. Sec 705
32. Attic access required; minimum opening: 22 x 30 inches./z, o'y
- 33.- Fireplace hearth: minimum depth in front of opening is inches."
34. Attic ventilation required; minimum 1 /150th of the vented space. 3205(c)
35. One hour firewall with a self closing 1 3/8" solid core door is required between the
house and the garage. 503(d) for
36. A " in" rlebedroom smoke
locate
detectors top of bedroom
the stairway. Any other
second story bed
` alarm trips other alarms. 1210(a) Sec 2517(8)5
X 37. Headers over doors & windows will be on edge.
38.
39.
40.
41.
42.
I AGREE TO COMPLY WIT HE ABOVE REQUIREMENTS.
DATE_ 2'' -43